HorticultureLED SolutionsGreenPower LEDtoplightingQuick installation guideUSA/CanadaWARNINGTurn off and disconnect power before installation. Must be installedby a qualified electrician in accordance with all national and localelectrical and construction codes and regulations.IMPORTANT!IP66Damp & wet locationsVerify and follow local electric codes for the installation site: Make sure that power cords are routed in a manner that would prevent incidental damagemin0 C32 Fmax40 C104 F Make use of junction boxes that are suitable for the power cords used in the applicationCUS Make use of strain-relief or power cord grip in case neededDimensions in mm/inchProductDimensions (mm/inch)GreenPower LED toplighting moduleLengthWidthHeight1264.2 / 49.7755.2 / 2.1780.2 / 3.16Note: build length is 1250 mm (49.213 inch).80.2 / 3.1655.2 / 2.17101248 / 49.131264.2 / 49.77Note:Male connectorend is line (mains)October 2015PHIL 153166 QIG toplighting ULCSA A03.indd 130-10-15 14:54

Continuous line installationThis is an installation in which modules are connected to one another ina continuous line.What do you need?WARNING DO NOT connect to live poweruntil installation is completeLED toplighting moduleMounting bracket DO NOT attempt to install or useuntil you read and understand theinstallation instruction and safetylabels DO NOT modify or alter theproduct; doing so will void thewarrantyEnd capMains power cableWhat steps to take:1Mount 40 x 40 mm 1.5 mm (1.57 x 1.57 inch 0.06 inch) C-profileframing system onto your greenhouse structure at thedesired height. Do not place any hooks on the exterior of theframing system that exceeds the 12 mm (0.472 inch) clearance.12 mm /0.472 inchClearanceC-profileToplight module2Attach two mounting brackets onto the framing system at apitch distance of 1250 mm (49.21 inch). Be sure mountingbrackets face same direction with prongs pointing away fromthe power source.MAINS input130 mm /5.12 inch1250 mm / 49.21 inch3With the male end of LED module directed towards power source,position the LED module parallel and close to framing system.Slide the module towards the mounting bracket so that the bracketprongs pass through the module’s mounting holes and until themodule snaps into the bracket’s back locking point.AB2Back locking pointPre-positioning pointQuick installation guide - GreenPower LED toplighting USA/CanadaPHIL 153166 QIG toplighting ULCSA A03.indd 2AABOctober 201530-10-15 14:55

4On the opposite end of the module, take the second mountingbracket and slide it towards the end of the module so that theprongs pass through the module’s mounting holes. Snap thebracket into the bracket’s pre-positioning point.AB5Female or end of modulePre-positioning pointBBTake a second toplighting module and position it with the frontend (male connector) towards the back end (female connector)of the first module.AB6AAFemaleMalePlug the two modules together. Be sure the mounting bracket issecure by snapping both modules into the back locking point ofthe bracket. This will securely support the modules and ensurethat the modules remain stable.AABCModule 1Module 2Back locking pointBBBClickC7Repeat steps 2-6 until the maximum number of modules is reached. See page 6 for maximum number ofmodules for power grid and system configuration.8For the last module in the line, insert an end cap into the femaleconnector until the end cap clicks into place. This must be doneto ensure safe system operation and also protect the modulefrom moisture and debris. Proper installation of the end capensures the module is IP66 and "damp & wet location" rated.9Return to the first module in the line and securely plug the femaleconnector with cable and then connect the cable to the mainspower source.ABFemaleMaleABWARNING* Refer to the table on page 6 to determine the maximum number of modules that can be interconnected.DO NOT use more than a 15 amp C type circuit breaker in combination with the type of power grid available(208 V - 240 V - 277 V - 347 V).DO NOT connect to live power until installation is complete.October 2015PHIL 153166 QIG toplighting ULCSA A03.indd 3Quick installation guide - GreenPower LED toplighting USA/Canada330-10-15 14:55

Non-continuous line installationThis is an installation in which modules are placed at distances specifiedby the light plan and modules are connected with jumper cables.What do you need?WARNING DO NOT connect to live poweruntil installation is completeLED toplighting moduleMounting bracket DO NOT attempt to install or useuntil you read and understand theinstallation instruction and safetylabels DO NOT modify or alter theproduct; doing so will void thewarrantyJumper cable**Jumper cableIn case of distances greater than2000 mm (6.6 ft) use two jumpercables.End capMains power cableWhat steps to take:1Mount 40 x 40 mm 1.5 mm (1.57 x 1.57 inch 0.06 inch) C-profileframing system onto your greenhouse structure at thedesired height. Do not place any hooks on the exterior of theframing system that exceeds the 12 mm (0.472 inch) clearance.C-profile12 mm /0.472 inchClearanceToplight module2Attach two mounting brackets onto the framing system at a pitchdistance of 1250 mm (49.21 inch). Be sure mounting brackets arepositioned with prongs pointing inward and towards each other.130 mm /5.12 inch1250 mm / 49.21 inch4Quick installation guide - GreenPower LED toplighting USA/CanadaPHIL 153166 QIG toplighting ULCSA A03.indd 4October 201530-10-15 14:55

3Position the LED module parallel and close to framing system.Slide the module towards the mounting bracket so that the bracketprongs pass through the module’s mounting holes and until themodule snaps into the bracket’s back locking point.BBack locking pointB4On the opposite end of the module, slide the second mountingbracket towards the end of the module so that the prongs passthrough the module’s mounting holes. Snap the bracket into thebracket’s back locking point.BBack locking pointB5Continue to attach modules to the C-profile framing system by repeating steps 2-4 until maximum number ofmodules is reached. See page 6 for maximum number of modules for power grid and system configuration.6Connect the modules with jumper cables.A) For installations with modules placed at distances less than2000 mm (6.6 ft), use a Philips jumper cable to connect eachmodule.B) If the modules are at distances greater than 2000 mm (6.6 ft)connect two jumper cables together.7Continue connectingthe modules withjumper cables.ABFemaleMaleAB8For the last module in the line, insert an end cap into thefemale connector until the end cap clicks into place. This mustbe done to ensure safe system operation and also protect themodule from moisture and debris. It also secures the IP66 or"damp & wet locations" rating.9Return to the first module in the line and securely plug the femaleconnector with cable and then connect the cable to the mainspower source.October 2015PHIL 153166 QIG toplighting ULCSA A03.indd 5ABQuick installation guide - GreenPower LED toplighting USA/Canada530-10-15 14:55

WARNINGTo determine the maximum number of modules that can be interconnected refer to the table below.Do not use more than a 15 amp C type circuit breaker in combination with the type of power grid available(208 V - 240 V - 277 V - 347 V).DO NOT connect to live power until installation is complete.Maximum number of LED modules connected to power grid related to system configurationMains VoltageSystem configuration[Vac]Circuit Breaker C-typeCircuit BreakerMax # of modules[Amp]configuration typeper phase 2P14277P-N154P17347P-N154P21N NeutralP Phase3P 3 phase breaker type2P 2 Phase breaker type4P 3Phase Neutral breaker typeFor detailed system configurations see Application Guide6Quick installation guide - GreenPower LED toplighting USA/CanadaPHIL 153166 QIG toplighting ULCSA A03.indd 6October 201530-10-15 14:55

Specifications Philips GreenPower LED toplightingPhilips GreenPower LED toplightingVoltagePhotonPowerfluxconsumptionUseful s / L90hours / L70cos ϕDeep Red/Blue - Low Blue200-40055021525,000TBD› 0.95 @ 400 VIP66Deep Red/Blue - Low Blue - Wide beam200-40052021525,000TBD› 0.95 @ 400 VIP66Deep Red/Blue - Medium Blue200-40055021525,000TBD› 0.95 @ 400 VIP66Deep Red/Blue - High Blue200-40052020025,000TBD› 0.95 @ 400 VIP66Deep Red/White - Low Blue200-40052020025,000TBD› 0.95 @ 400 VIP66Deep Red/White - Medium Blue200-40052020025,000TBD› 0.95 @ 400 VIP66Deep Red/White - Medium Blue VISN200-40043019025,000TBD› 0.95 @ 400 VIP66200-40041017525,000TBD› 0.95 @ 400 VIP66rating**Deep Red/Blue typesDeep Red/White typesDeep Red/White/Far Red typeDeep Red/White/Far Red - Medium Blue* Lifetime and maintenance values are given at an ambient temperature of 25 C / 77 F.** For damp & wet locations.Ordering data Philips GreenPower LED toplightingPhilips GreenPower LED toplightingProduct IDOrder code6NC12NCDeep Red/Blue typesDeep Red/Blue - Low Blue 1GPL toplighting DR/B LB 200-400V3038189290 009 79906Deep Red/Blue - Low Blue - Wide beam 1GPL toplighting DR/B LB 200-400V WB3038349290 009 80006Deep Red/Blue - Medium Blue 1GPL toplighting DR/B MB 200-400V3038429290 009 80106Deep Red/Blue - High Blue 1GPL toplighting DR/B HB 200-400V3038599290 009 80206Deep Red/White - Low BlueGPL toplighting DR/W LB 200-400V3038679290 009 80306Deep Red/White - Medium BlueGPL toplighting DR/W MB 200-400V3038839290 009 80406Deep Red/White - Medium Blue VISNGPL toplighting DR/W MB VISN 200-400V3038919290 009 80506GPL toplighting DR/W/FR 2 MB 200-400V3039099290 009 80606Deep Red/White typesDeep Red/White/Far Red typeDeep Red/White/Far Red - Medium Blue1 Eye safety risk group 2IEC62471 : Photobiological safety of lamps and lampsystems. LED does not pose a hazard due to the aversion response or thermal discomfort.Accessories Philips GreenPower LED toplightingPhilips GreenPower LED toplightingRemarksOrder code6NC12NCGPL bracket toplighting NAMStainless steel wire of 2 mm (0.08 inch) in diameter3039259290 015 08106GPL toplighting jumper NAM 6.6ft3 x 2.0 mm2 (AWG14) wire conductors3039339290 015 08206GPL toplighting main power cable TB3 x 2.0 mm2 (AWG14) wire conductors 2 meter (6.6 ft)TBD9290 015 162063039669290 009 15606GPL toplighting end capOctober 2015PHIL 153166 QIG toplighting ULCSA A03.indd 7Quick installation guide - GreenPower LED toplighting USA/Canada730-10-15 14:55

2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes inspecifications and/or to discontinue any product at any time without notice or obligation andwill not be liable for any consequences resulting from the use of this publication.For more information aboutPhilips Horticulture LED Solutions visit:www.philips.com/hortiDocument order number: 3222 635 70068 - UL/CSA - V110/2015Data subject to changeWrite us an e-mail:horti.info@philips.comOr tweet us:@PhilipsHortiPHIL 153166 QIG toplighting ULCSA A03.indd 830-10-15 14:55

Deep Red/Blue - Low Blue 1 GPL toplighting DR/B LB 200-400V 303818 9290 009 79906 Deep Red/Blue - Low Blue - Wide beam 1 GPL toplighting DR/B LB 200-400V WB 303834 9290 009 80006 Deep Red/Blue - Medium Blue 1 GPL toplighting DR/B MB 200-400V 303842 9290 009 80106 Deep Red/Blue - High Blue 1 GPL toplightin

Related Documents:

Aug 21, 2019 · philips lytecaster 344dstx-302mrex-42017-4 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 . recessed white 4" recessed downlight led, 1160 delivered lumens, 3000k, 90 cri cree lighting eaton mcgraw-edison ist-af-350-

Course Title - Principles of Horticulture and production technology of fruit crops Credit hours - 3 (2 1) Lec.No. Topic / Lecture Page No. 1 Definitions of Horticulture-literal meaning, olden day‘s horticulture and modern horticulture. Divisions of horticulture-Pomology, olericulture ,floriculture (commercial

AGY 303 LECTURE NOTE FUNDAMENTALS OF HORTICULTURE Introduction Horticulture is derived from two Latin words: Hortus and Colere. Horticulture is a science that deals with the production and utilization of garden crops. Horticulture is divided into four branches. Floriculture: the science of production and utilization of ornamental plants

A. Drive Bays M. Memory Fault LED B. UID Button N. UID Button C. Optical Disk Drive O. Module Power LED D. System Power LED P. SAFE TO PULL LED E. System Status LED Q. PRIMARY LED F. System FT LED R. IO Module Fault LED G. UID LED S. Fan Fault LED H. USB Connector T. PSU Fault LED I. Pull-out Tab U. DC Power Fault LED J. Power Button V .

Horticulture I 6841, is designed to be taught after students have completed Introductk .t to Agriculture and Natural Resources. The course contains five broad units of insttuction, specifying 39 competencies. The focus of the course is on basic knowledge and skills for Horticulture, upon whic

1.2 Importance of horticulture in terms of economy, production, employment. generation, environmental protection and human resource development . 1.3 Scope for horticulture in India. Nutritive value of horticultural crops . 1.4 Divisions of horticulture with suitable examples and their importance.

This course also focuses on horticulture structures. Course Description: Horticulture Plant Processes focuses on plant propagation, principles of pest management greenhouse crops, and olericulture production. Course Description: Horticulture Nursery is a comprehensive course that reviews leadership, careers,

horticulture may be an existing use or a temporary use on small lots adjacent to residential uses. Table 1 outlines recommended levels of assessment for intensive horticulture in these zones or precinct. 2 A local Government could establish an intensive production precinct in its planning scheme to support intensive horticulture in the rural zone.