Isokern PumicePrice ListSystem Chimneys, Liners,Garden Fireplaces and Stove Systemswww.schiedel.com/ukUpdated March 2021

Pumice – naturally betterPumice is a natural insulator. This is the uniqueproperty that separates pumice from all otherchimney materials.The insulating properties of Pumice allow theflue gases in the chimney to quickly reach theiroptimum temperature enabling the heatingappliance to reach its optimum performanceshortly after lighting.It also keeps the chimney warmer longer as theheat output of the appliance decreases – onceagain aiding performance and reducing thelikelihood of condensation and soot build-up.Pumice: is an excellent insulator, keeping flue gases warm while not transmitting heat tothe outside.The natural propertiesof pumiceResistant to temperature changePumice has very little expansion and contractionwith temperature change. This reduces thepossibility of cracking and structural damage thatcan occur with other products.High Insulation PropertiesPumice is a natural insulator, able to maintain thetemperature of flue gases when other productshave allowed the temperature to fall below the dewpoint.Pumice is a natural material sourced from theHekla Volcano in Iceland.LightweightPumice is strong yet lightweight allowing one personto lift and build the chimney units.Pumice is strong, yet lightweight and comes ineasy building blocks.2

Product DescriptionSchiedel Isokern products can be used for newchimneys and for the refurbishment of existingchimneys. The Isokern chimney systems providea lightweight, easily installed and versatile chimneywhich can be used internally or externally.The systems are suitable for use with burningappliances in new and refurbished projects. Theyare ideal for Masonry, Timber Frame and SteelFrame construction. Isokern chimneys have beeninstalled in Europe for over 60 years.DM (DOUBLE MODULE)Schiedel Isokern DM block system is a high quality System Chimney. Thedouble wall system maintains flue gas temperatures while preventingheat transference to the outer casing. The separation of the inner andouter components also allows for thermal movement, reducing the riskof cracking and subsequent leaking or staining. It is simple and quickto build. The DM is available in 3 outer casing sizes - DM36, DM44 &DM54.FLUE LINERSThe Schiedel Isokern flue liner range consists of over 15 differentsizes. They can be used for newbuild, extensions and relining existingchimneys.FIRECHESTSThe Schiedel Isokern range of firechests are supplied as flat packs.They can be easily and quickly constructed to produce a neat and preformed fire opening ready for finishing. The Magnum Firechest providesthe opportunity to create fire openings up to 1.2m wide.ISOKOAT FLUE SEALING SYSTEMThe Schiedel Isokoat system is an efficient and cost effective methodof re-sealing a defective chimney shaft. The Isokoat material is appliedto the chimney under pressure and forced into the cracks sealing them,re-pointing the joints and strengthening the walls. For further detailssee the separate Isokoat leaflet.For more details on these ranges, please see pages 19 onwards.3

DM 36 – for smaller outputinserts, stoves and cookers4SAP CodeDescriptionWeight(kg)Price130714360mm square casing 250mm high15 26.62130712360mm square access casing 250mm high (150mmi/d access hole)13 45.65130713360mm square casing & soot door 250mm high18 171.18130709DM36 45º flue entry kit (four parts) 500mm high42 156.14126363150mm i/d 255 x 255 starter flue block 125mm high 4 22.91126369150mm i/d 255x255 flue block 250mm high8 22.91126368150mm i/d 255x255 access flue block 500mm high(177mm i/d access hole)16 58.90130715570mm square corbel for brickwork 75mm high32 72.82130710130711490mm square capping - render690mm square capping - brickwork1331 53.73 79.08126378150mm i/d 360 x 435 offset block (86mm, 30 offset)150mm high (allow 38mm distance to combustibles onoffset chimneys)25 60.56130716150mm i/d 360 square support block 100mm high15 46.47126373150mm i/d (205mm o/d) stainless steel adaptor 58.70126357125-150mm i/d (205mm o/d) stainless steeldecreaser adaptor 65.73130732Raincap (with fixing rods for top ring) 82.89135070Top Ring (for ventilation) 70.72All dimensions are external unless otherwise stated

DM 44 – for inserts, stovesand small open firesSAP Code DescriptionWeight Price(kg)130727440mm square casing 300mm high30 35.38130725440mm square access casing 300mm high (220mm i/d access29hole) 60.42130726440mm square casing & soot door 300mm high36 171.03130719130722440mm 180mm i/d 45 flue pipe entry kit (4 parts) 600mm high440mm 200mm i/d 45 flue pipe entry kit (4 parts) 600mm high8684 174.90 174.90130720127684180mm i/d 310 x 310 starter flue block 150mm high200mm i/d 310 x 310 starter flue block 150mm high87 25.87 26.34127068127683180mm i/d 310 x 310 flue block 300mm high200mm i/d 310 x 310 flue block 300mm high1514 29.67 30.41130717127682180mm i/d flue 310 x 310 access block 600mm high200mm i/d flue 310 x 310 access block 600mm high2826 76.22 77.74130728130235650mm square corbel for brickwork 75mm high650 x 560mm offset corbel for brickwork 75mm high4034 79.03 79.03130818740mm T corbel for external brickwork 75mm high47 128.47130723130724570mm square capping for render820mm square capping for brickwork1844 53.73 79.03135082130718127686127687180mm i/d 440 x 500 offset block (56mm, 30 offset) 100mm high180mm i/d 440 x 500 offset block (86mm, 30 offset) 150mm high200mm i/d 440 x 500 offset block (56mm, 30 offset) 100mm high200mm i/d 440 x 500 offset block (86mm, 30 offset) 150mm high(Allow 38mm distance to combustibles on offset chimneys)22322030 59.66 67.80 59.66 67.80130721130730180mm i/d 440mm square support block 100mm high200mm i/d 440mm square support block 100mm high2220 59.37 60.48127691200mm i/d (255mm o/d) stainless steel adaptor 64.68127671127672150-200mm i/d (255mm o/d) stainless steel decreaser adaptor175-200mm i/d (255mm o/d) stainless steel decreaser adaptor 74.69 74.69130732Raincap (with fixing rods for top ring) 82.89130675Top Ring (for ventilation) 70.72All dimensions are external unless otherwise stated5

DM 54 – for larger openfires and appliancesSAPCodeDescriptionWeight Price(kg)130708545mm square casing 300mm high40 62.55129031129093300mm i/d 420 x 420 starter flue block 150mm high345mm i/d 420 x 420 starter flue block 150mm high1111 36.69 36.69129033129094300mm i/d 420 x 420 flue block 300mm high345mm i/d 420 x 420 flue block 300mm high2222 39.78 39.78130735800mm square corbel for brickwork 75mm high57 92.97130733130734670mm square capping for render950mm square capping for brickwork2046 71.86 85.03129038129092300mm i/d 545 x 635 offset block (86mm, 30 offset) 150mm high345mm i/d 545 x 635 offset block (86mm, 30 offset) 150mm high(allow 38mm distance to combustibles on offset chimneys)4440 82.00 82.00129043300mm i/d 545mm square support block 100mm high30 73.93129039300mm i/d (365mm o/d) stainless steel adaptor 175.18130732Raincap (with fixing rods for top ring) 80.04135093Top Ring (for ventilation) 82.89DM 21500 x 215 x 70mm support lintel Max load (per pair) 1650kg51 51.76130689Stainless steel casing wall tie130771Lip glue (5kg)5 14.141026291m reinforcement rod 12mm diameter1 10.82All dimensions are external unless otherwise stated 7.20

Liners and 4161927506070100 36.56 43.79 45.58 59.51 67.24 86.76 97.38 238.38 275.98 339.29 475.14Round 9567129738129927130142150mm i/d 600mm high rebated liner (200mm o/d)175mm i/d 600mm high rebated liner (235mm o/d)200mm i/d 600mm high rebated liner (250mm o/d)225mm i/d 600mm high rebated liner (285mm o/d)250mm i/d 600mm high rebated liner (310mm o/d)300mm i/d 600mm high rebated liner (360mm o/d)350mm i/d 600mm high rebated liner (416mm o/d)400mm i/d 1000mm high rebated liner (470mm o/d)450mm i/d 1000mm high rebated liner (530mm o/d)500mm i/d 1000mm high rebated liner (590mm o/d)600mm i/d 1000mm high rebated liner (706mm 356 5.59 7.03 7.25 8.76 10.07 12.09 14.14150mm steel collar175mm steel collar200mm steel collar225mm steel collar250mm steel collar300mm steel collar350mm steel collarSupport Lintel1464311500 x 140 x 140mm support lintels Max load (per pair)3250kg71 100.22169330600 x 100 x 65mm support lintels9 8.3533 42.90 49.79Support Plates (for supporting liners and support blocks)127694128549210mm i/d 360mm square 4mm thick (fits 150mmsupport blocks)255mm i/d 360mm square 4mm thick (fits 175mm and200mm support blocks)7

Liners and AccessoriesSAPCodeDescriptionWeightPrice(kg)Liner Support Blocks (for connection to single wall connecting flue pipe)126366126483127340130731128548129043150mm i/d 310mm square 75mm high175mm i/d 350mm square 75mm high200mm i/d 350mm square 75mm high225mm i/d 440mm square 100mm high250mm i/d 440mm square 100mm high300mm i/d 545mm square 100mm high788202030 34.42 40.48 46.56 62.96 68.34 73.93150mm i/d 45 rebated T liner 600mm high175mm i/d 45 rebated T liner 600mm high200mm i/d 45 rebated T liner 600mm high150mm i/d 90 rebated T liner 600mm high15202215 132.00 137.52 143.10 132.0050 litre (0.05m3)approx.19 18.36Lip glue (5kg)5 14.14T Liners126376126500127695126375Light expanded clay aggregate130769Lip Glue1307718All dimensions are external unless otherwise stated

Liners and AccessoriesSAP Code DescriptionWeight(kg)PriceLiner Bends126364126365126367150mm i/d 15 rebated bend150mm i/d 30 rebated bend150mm i/d 45 rebated bend456 49.44 49.44 49.44126495126496126497175mm i/d 15 rebated bend175mm i/d 30 rebated bend175mm i/d 45 rebated bend568 64.14 64.14 64.14127679127680127681200mm i/d 15 rebated bend200mm i/d 30 rebated bend200mm i/d 45 rebated bend568 66.61 66.61 66.61127706127707127708225mm i/d 15 rebated bend225mm i/d 30 rebated bend225mm i/d 45 rebated bend789 78.90 78.90 78.90128542128531128532250mm i/d 15 rebated bend250mm i/d 30 rebated bend250mm i/d 45 rebated bend8910 96.49 96.49 96.49129015129016131819300mm i/d 15 rebated bend300mm i/d 30 rebated bend300mm i/d 45 rebated bend101112 120.94 120.94 120.94129354129355131820350mm i/d 15 rebated bend350mm i/d 30 rebated bend350mm i/d 45 rebated bend131416 136.76 136.76 136.76Larger diameter bends available on request.Stainless Steel Adaptors with Sealing Rope (for connection to support block)126373126499127691127719128547129039150mm i/d (205mm o/d)175mm i/d (235mm o/d)200mm i/d (255mm o/d)225mm i/d (290mm o/d)250mm i/d (315mm o/d)300mm i/d (365mm o/d) 58.70 61.70 64.68 72.62 111.38 175.18Stainless Steel Increaser Adaptors with Sealing Rope (for connection to support block)126357126493127671127672127704125-150mm i/d (205mm o/d)150-175mm i/d (235mm o/d)150-200mm i/d (255mm o/d)175-200mm i/d (255mm o/d)200-225mm i/d (290mm o/d) 65.73 74.69 74.69 74.69 78.90Stainless Steel Adaptors with Sealing Rope (for connection to T liners)125453126358146412146413125-150mm i/d (210mm o/d)150mm i/d (210mm o/d)150-175mm i/d (240mm o/d)175mm i/d (240mm o/d) 65.73 58.70 74.69 61.709

Liners and AccessoriesWeight(kg)Price150mm i/d 215mm square 205mm high rebated access block200mm i/d (also for 175mm) 280mm square 280mm high rebatedaccess block512 20.22 38.43Double soot door 265 x 395mm2 92.974 18.8214161218192632 54.58 57.07 43.77 57.07 68.46 111.96 166.7114161218192632 54.58 57.07 43.77 57.07 68.46 111.96 166.71222 81.85 133.03 142.55222 81.85 133.03 142.55SAP Code DescriptionAccess Blocks126362127678Soot Door142837Insulated Plug142599Insulated plug (glue to access blocks)Chimney PotsTerracotta150mm i/d roll top terracotta 450mm high200mm i/d roll top terracotta 450mm high225mm i/d roll top terracotta 300mm high225mm i/d roll top terracotta 450mm high250mm i/d roll top terracotta 450mm high300mm i/d roll top terracotta 450mm high350mm i/d roll top terracotta 450mm 150mm i/d roll top buff 450mm high200mm i/d roll top buff 450mm high225mm i/d roll top buff 300mm high225mm i/d roll top buff 450mm high250mm i/d roll top buff 450mm high300mm i/d roll top buff 450mm high350mm i/d roll top buff 450mm uardsTerracottaTopguard terracotta 150-250mm i/dTopguard terracotta 300mm i/dTopguard terracotta 350mm d buff 150-250mm i/dTopguard buff 300mm i/dTopguard buff 350mm i/dNotice Plate130696Chimney notice plate 6.48Smoke Pellets13081710Smoke pellets (6 per tube)All dimensions are external unless otherwise stated 11.80

FirechestsSAP HeightDepth(mm)(mm)(mm)(mm)(mm)(kg)PriceMagnum Firechests1307735005105406851540440390 920.6112937195099096010901761710715 962.331295681100113096012301761710790 1,291.251297671200124696013461761710845 1,619.20850660450100 322.60Magnum 500 Inside Flue diameter 200mmMagnum 950 - 1200 Inside Flue diameter 350mmStandard Firechests130820SAPCode690Model660InsideFlue 8 387.31 387.31 606.34 606.34225200690690850850600600450450100100 205.79 0550550110130138 88.10 111.24 114.60Manor Gathers133463135267135280135279900 Centre Hole900 Offset Hole1150 Centre Hole1150 Offset HolePumice Gathers130822130729LinerDM44Concrete Gathers130699131200131201SAP CodeC16C17C18DescriptionWeight (kg)Price1.62.82042.5 2.84 5.25 47.79 79.66Firebricks and Firebacks112562115281130753129735Firebrick 230 x 114 x 25mm buffFirebrick 230 x 114 x 50mm buffFirebrick mortar450mm milner scored clay fireback11

Garden FireplaceSAPCodeProduct NameINC-VATRRP169566500 Model 927.72 1,113.26169567950 Model 1,354.32 1,625.181695681200 Model 1,740.96 2,089.15157838Log Storage for 500 140.40 168.48157837Log Storage for 950 194.40 233.28168902Log Storage for 1200 210.60 252.72130727130708Additional Block for 500Additional Blocks for 950 and 1200 35.38 62.55 42.46 75.06130723Capping for 500 model 53.73 64.48130675135093Top Ring for 500 modelTop Ring for 950 and 1200 70.72 80.04 84.86 96.05130732Rain Cap for all models 82.89 99.47130771Lip Glue 5kg 14.14 16.96135329Render Plaster 25kg bag 48.60 58.32155843Grillset for 950 and 1200 106.92 128.30Pallet ChargeEX-VATINC-VATGARDEN 5001 pallet 65 78GARDEN 9502 pallets 130 156GARDEN 12002 pallets 130 15612EX-VATKit includes: Modules for fireplace Log Retainer ChimneyBlocks Lip glue for assembly of fireplace and chimney Firebricks and firebrick mortar Render for finishRendered or unrendered Fireplace can be painted. Additionalchimney blocks can be purchased for extra height. Log storescan be positioned below or to the side.

Ignis-ProtectSAP 5565565565565565181296442222Ignis-Protect 90 Version101841101842101843101844101845101846 231.79 289.36 349.37 386.52 431.78 482.21Ignis-Protect 45 44032144033144034 160.59 235.76 316.57 512.61 614.53 716.84 810.58 1,044.57 1,084.65 1,250.76TYPICAL INSTALLATION OF45 VERSIONInsulationDamp proof barrierVapour barriermembranePlasterboardSchiedel IsokernDouble Module SystemPermanently elasticsealing stripIgnis-Protect - 45 External versionPrima Smoothconnecting flue pipesee p.23 and 24 fordetailsTimber framework for IgnisProtectPlasterboardHearth13

Starting ComponentsAppliance ConnectorInt Ømm40141SAP Code Painted 0.6mm0.6mm PS0131mm 939119937Price 30.67 31.41 31.29 32.81 38.99 42.85SAP Code Painted 1mm125360125364126254126258119931119929Price 30.67 32.58 31.29 34.21 38.99 28.27SAP Code Unpainted 0.6mm125361125365126255126259119940119938Price 26.70 26.84 27.30 27.49 35.01 37.55SAP Code Unpainted 1mm125366125366126256126260119932119930Price 26.70 26.70 27.30 27.49 35.01 37.55Swaged Starter Pipes40AInt Ømm Prima SmoothSAP Code Painted A 1000 1mm125150180200133984133987133993133996Price 76.69 82.52 98.25 106.76SAP Code Unpainted A 1000 1mm133956133959133965133968Price 61.54 65.58 80.34 99.40SAP Code Painted A 500 1mm133985133988133994133997Price 43.75 61.16 65.21 72.37SAP Code Unpainted A 500 1mm133957133960133966133969Price 36.90 39.93 56.70 62.94SAP Code Painted A 250 1mm133986133989133995133998Price 28.04 28.88 38.87 41.91SAP Code Unpainted A 250 1mm133958133961133967133970Price 23.73 25.95 33.80 36.29Connecting Flue Pipe –Prima SmoothPipesStandard Pipe Effective Length 950mmInt Ømm50EffectiveLengthSAP Code Painted 0.6mm140.6mm PS001 1mm PS101125150180200122583114554119860119858Price 46.66 50.89 63.45 77.55SAP Code Painted 1mm122584119954119957119955Price 65.73 67.86 75.70 96.49SAP Code Unpainted 0.6mm113272114550119861119859Price 33.92 38.17 47.70 58.31SAP Code Unpainted 1mm115948116338119958119956Price 53.02 55.12 72.36 91.12

Connecting Flue Pipe –Prima SmoothPipesInspection Pipe Effective Length 950mmInt Ømm50EffectiveLengthSAP Code Painted 0.6mm0.6mm PS011 1mm PS111125150180200114177114707119864119862 114.57Price 57.25 61.50 96.94SAP Code Painted 1mm115979116477119961119959Price 91.17 97.53 132.52 143.73119863SAP Code Unpainted 0.6mm114179114709119865Price 44.52 48.75 72.89 86.14SAP Code Unpainted 1mm113482114708119962119960Price 78.46 84.81 120.60 127.83Standard Pipe Effective Length 450mmInt Ømm50 EffectiveLengthSAP Code Painted 0.6mm0.6mm PS002 1mm PS102125150180200122585111973119868119866Price 29.69 33.92 42.31 49.36SAP Code Painted 1mm125375120601119965119963Price 44.52 48.76 58.31 68.26SAP Code Unpainted 0.6mm111487111972119869119867Price 23.32 25.44 31.81 37.11SAP Code Unpainted 1mm112994113393119966119964Price 38.17 40.29 50.36 60.31Inspection Pipe Effective Length 450mm50EffectiveLengthInt ØmmSAP Code Painted 0.6mm0.6mm PS012 1mm PS112125150180200112081112155119970119870Price 42.41 48.76 70.50 77.55SAP Code Painted 1mm114182114252119969119967Price 61.50 67.86 83.75 88.87SAP Code Unpainted 0.6mm112083112150119873119871Price 36.05 40.29 53.02 58.31SAP Code Unpainted 1mm111608112115119970119968Price 55.12 59.37 75.95 79.59Standard Pipe Effective Length 200mmInt Ømm50 Eff.LengthSAP Code Painted 0.6mm0.6mm PS003 1mm PS103125150180200122586110716119880119878Price 22.26 24.40 31.73 35.25SAP Code Painted 1mm125374120602119977119975Price 24.40 24.40 34.45 39.75SAP Code Unpainted 0.6mm110485110723119881119879Price 19.08 21.20 23.85 26.50SAP Code Unpainted 1mm111302111543119978119976Price 21.20 21.20 31.34 33.80Standard Pipe Effective Length 250mmInt Ømm50Eff.LengthSAP Code Painted 0.6mm0.6mm PS0041mm PS104125150180200122587111169119876119874Price 30.75 34.99 51.11 56.41SAP Code Painted 1mm122588119985119973119971 49.83 54.06 54.06 57.78110885111165119877119875PriceSAP Code Unpainted 0.6mmPrice 27.57 31.81 38.43 42.41SAP Code Unpainted 1mm110850110850119974119972Price 46.66 50.89 42.41 45.0715

Connecting Flue Pipe –Prima SmoothBends45 45 Bend0.6mm PS015 1mm PS115BInt ØmmASAP Code Painted 0.6mm125150180200121422110717119911119909Price 31.81 33.92 38.43 43.04SAP Code Painted 1mm122589120013120007120005Price 33.92 36.05 47.44 59.64SAP Code Unpainted 0.6mm110468110720119912119910Price 27.57 29.69 33.12 37.11SAP Code Unpainted 1mm110515110707120008120006Price 29.69 31.81 43.42 55.4812515018020012259411133511991511991345 Inspection BendCAB45 0.6mm PS044 1mm PS144Int ØmmSAP Code Painted 0.6mmPrice 44.52 46.66 61.50 67.64SAP Code Painted 1mm121423120004120011120009Price 57.25 59.37 78.72 82.16SAP Code Unpainted 0.6mm110875111332119916119914Price 40.29 42.43 53.02 57.34SAP Code Unpainted 1mm110948111324120012120010Price 53.02 55.12 74.21 76.86Offsets (made by assembling 2 bends)A45o OffsetInt Ømm125150180200A mm333333333333B mm138138138138200BInt Ømm125150180A mm415415415415B mm138138138138C mm94949494CA45o Offset (using Inspection Bend)B45 Offset with standard Pipe lengthsInt ØmmfPEfAipeEffective Pipe 950Effective Pipe 450Effective Pipe 200B125150180200A mm1005100510051005B mm810810810810A mm651651651651B mm456456456456A mm474474474474B mm27927927927945 Offset with standard Pipe lengths (using Inspection Bend)PipeInt ØmmAEffEffective Pipe 950Effective Pipe 450B16Effective Pipe 200A mm1251501802001087108710871087B mm810810810810A mm733733733733456B mm456456456A mm556556556556B mm279279279279

Connecting Flue Pipe –Prima SmoothAdditional Components1 Piece Trim Collar 90 BA0.6mm 9580PInt ØmmSAP Code Painted1501802000.6mm126337127039127643 24.03 34.10 34.610.6mm164279127038127642 24.03 28.56 29.051501802000.6mm147394126613127187 38.47 39.95 35.590.6mm125887126612127186 31.11 34.83 35.59PriceSAP Code UnpaintedPriceCA1 Piece Trim Collar 45 0.6mm 9589PInt ØmmSAP Code PaintedBDPriceSAP Code UnpaintedPriceTest Point0.6mm PS003 1mm PS103Int Ømm260450SAP Code Painted 0.6mmPriceSAP Code Painted 1mmPriceSAP Code Unpainted 0.6mm125150180200146361146365146369146373 41.15 42.16 46.08 47.90146363146375146371146367 47.57 59.01 56.18 49.81146360146364146368146372Price 25.00 25.61 29.11 30.53SAP Code Unpainted 1mm146362146366146370146374Price 31.43 33.25 39.21 41.64Wall Sleeve 45 (for masonry wall only)A MasonryA94620200230250288306SAP Codes Masonry125894126641127205128102128587Price 30.02 32.37 33.53 36.55 38.76Supplied as a 1m long mitred tube to be cut to length on site. For timber framed houses, see Ignis Protect on p.23Wall Sleeve 90 (for masonry wall)A MasonryA94980200230250SAP Codes Masonry147392126642127206Price 34.54 34.73 34.73For timber framed houses, see Ignis Protect on p.2317

Celsius Stove PackageSAP code168058ProductCelsius blocks complete, 440x440x1500DescriptionOnly pumice blocks for 1500 mm frameQty1List Price 529.29171262Celsius Acc. incl 4.5m Isoair, RenderChimney, capping, top ring, tape, glasscord, liner, glue, plastic wedges, mortarbags1 750.98172766Octagonal Adapt 150/100/1,0/316/MA/PS10Steel to Pumice adaptor1 65.00168059Celsius Mini InsertInsert and fresh air supply1 1,545.00168796Convection grid Celsius 90x250, WhiteSingle Unit2 153.21TOTAL for Celsius Package 3,043.48SAP codeProductDescriptionQtyList Price126369Isokern Air Liner250mm height4 84.84135142Isokern Air Case205mm height5 163.80 1 17.73Pack of 6 Spacers / Lip GlueTOTAL per 1m extra run 266.37SAP codeProductDescriptionQtyList Price135192Pack of 6 SpacersPack of 6 Spacers1 4.64130771Lip Glue5 Kg Bag1 13.09102629Reinforcement Rods1m Rod1 10.02135329Render PlasterBag of 25 Kg1 45.0018

DM Double ModuleChimney SystemWhen the ease of construction and maximum insulation matter then the DoubleModule System comes into its own. The system is designed to be quick and easy toinstall.The lightweight blocks are easy to handle. The outer and inner blocks are laid atthe same time but with staggered joints for safety and stability. The double layer ofpumice blocks separated by an air gap maximises the chimney insulation.The Pumice Systems are suitable for wood burning, solid fuel, oil and gas (notcondensing appliances including Biomass & Pellets).There are 3 systems covering a range of different internal diameters to meet therequirements of different appliances and uses:DM 36150mm internal diameter for smaller output inserts,stoves and solid fuel/oil cookersDM 44180mm and 200mm internal diameters for inserts,stoves and open firesDM 54300mm and 345mm internal diameters for Magnumfirechests and larger appliances, inserts and openfires1919

Unique features of the IsokernDM Chimney SystemZero distance to combustibles on straightrendered chimneysQuick and easy to assembleLightweight materials, easy to handleHighly insulating pumice for better draw andminimum heat lossStaggered joints for maximum safety andstabilityAir gaps between outer casing and flueprevents surface stainingGood resistance to temperature variationsgives the maximum performance for yourapplianceApprovalsIsokern Pumice Double Module DM is CE Certified to EN1858 TÜV Cert no. 0036 CPR 90219 001Isokern Pumice Chimney Liner is CE certified to EN1857 TÜV Cert no. 0036 CPR 90219 002Isokern Magnum Firechest has been tested at the Fraunhofer Institut, Stuttgart, Cert no. P8-094/2006CE DesignationDouble Module DMPumice Chimney LinerSystem Chimney*T600 N2 D 3 GT450 N1 D 3 G(00)* Zero distance to combustibles on straight chimney systems with ventilated terminal.38mm distance to combustibles on offset systems. and non ventilated systems.2020

DM 36 – for smalleroutput inserts, stovesand cookersAvailable in Ø150mm internal diameter only.FREE STANDING STOVE IN A RECESSSystem includes a Stainless Steel adaptor for ease ofconnection between the stove and the DM Chimney.FREE STANDING STOVE WITH EXTERNALCHIMNEY AND PREFORMED FLUE ENTRYKITChimney potSand/cementflaunchingRaincapTop RingCapping for brickchimney stackWeep holesabove trayLead tray andflashingCapping for renderedchimney stackCasing renderedabove roofLead flashingCorbel forbrick stackFlue blocks installedwith socket uppermostStaggered jointsbetween casingand flue blockOuter casings drylined or plasteredSupport blockand adaptorfor connectionto stove pipePrima Smoothconnecting flue pipesee p.23 and 24for details2 x casingties at maximumintervals of1.5 metresFlue pipe fitted intoaccess casing at 45 Prima Smoothconnecting flue pipesee p.23 and 24for detailsDOWNLOADABLE DRAWINGS AVAILABLE FROM OUR WEB SITEWWW.SCHIEDEL.COM/UK21

DM 44 – for inserts,stoves and smallopen firesAvailable in internal diameters Ø180mm and Ø200mm.Both inner liners fit into the same external block size.INSET FIREOPEN FIRE USINGSTANDARD FIRECHESTRaincapRaincapTop RingTop RingCapping for renderedchimney stackCapping for brickchimney stackCasings renderedabove roofLip glue to seal jointsLead flashingAll joints sealedwith lip glueDM casings can befinished with plasterSupport blockand adaptor forconnection toflue pipePrima Smoothconnecting flue pipesee p.23 and 24for details130818 corbel tocomplete brick stackInner flue blocks withsocket uppermostStaggered jointsbetween casingand flue blockDM44 casings builtinto inner leaf ofcavity wallDM44 gatherStandard firechest(finished fireplaceopening size 590 x 550mm)Glass frontedinset fireSuitable foundationDOWNLOADABLE DRAWINGS AVAILABLE FROM OUR WEB SITEWWW.SCHIEDEL.COM/UK22

DM 54 – for largeropen fires andappliancesAvailable in internal diameters Ø300mm and Ø345mm.Both inner liners fit into the same external block size.LARGE FIRE OPENING CREATEDWITH MAGNUM FIRECHESTChimney potCapping for renderedchimney stackCasings renderedabove roofLead flashingDM casings can befinished with plasterJoints sealed withlip glueStaggered jointsbetween casingand flue blockMagnum firechestcomplete withdamperFiirebrick lininginside firechestDOWNLOADABLE DRAWINGS AVAILABLE FROM OUR WEB SITEWWW.SCHIEDEL.COM/UK23

Typical DM Installation DetailFOUNDATIONSConstruction begins by providing a suitable foundationand constructional hearth in accordance with BuildingRegulations and site requirements.OPEN FIRE OPTIONBed the base plate of the firechest onto a suitablefoundation/constructional hearth in accordance withBuilding Regulations and at the level required on siteusing Isokern lip glue.Install the firechest using lip glue making sure allelements are level. 100mm of brick/blockwork mustbe built around the sides and back of the firechest tocomply with Building Regulations. The inside of thefirechest must be finished with a suitable fireback orfirebrick slips.Install the gather using lip glue making sure all theelements are level. The front face of the gather can befinished with plasterboard, rendered or clad in masonry.Lintels may be required above the gather to help carrythe brick or blockwork. The maximum loading capacityof the ISOKERN firechest and gather is 2500kg.STOVE IN RECESS OPTIONPre-stressed lintels or a suitable cast-in-situ concreteslab must be provided above the stove recess, pleasemake sure they are strong enough to carry the load (seeappropriate Isokern DM drawing for aperture size). It isrecommended to have a minimum of 600mm of stoveflue pipe before connecting to the support block.The support block is bedded onto the lintels using aweak mix mortar. A stainless steeladaptor is used to create a positiveconnection from the support block tothe stove flue pipe (fibre rope shouldbe used to create a seal).LintelsSupportblockStainless steeladaptorPrima Smoothconnecting fluepipe see p.23and 24for detailsOPEN FIRE OPTIONGather elementsMagnumfirechestFirebrickslipsFREE STANDING STOVE OPTIONA soot door casing and access flue block must be usedbelow the flue pipe entry. The DM 45 access kit is thenused for the connecting flue pipe. A suitable wall sleevemust be used to seal the cavity wall. Any combustibleinsulation within the wall must then be kept away fromthe single wall connecting flue pipe by at least 1.5 x itsdiameter. Fibre rope is used to seal between the fluepipe and wall sleeve, a suitable trim collar can be usedto finish the inner wall surface.Suitable foundationFlue entry kitWall sleeve andfibre rope sealPrima Smooth connecting fluepipe see p.23 and 24 for detailsSoot door casing24

Typical DM Installation DetailCHIMNEY CONSTRUCTIONBed the first outer casing using lip glue making sure therebate (raised lip) is uppermost. The starter flue blockis then put inside the casing bedded with lip glue. Thesocket on the starter flue block must be uppermostand the air gap between the starter flue and the casingshould be kept clear. The finished lip glue joints shouldbe 2-3mm thick, a special bag is provided for ease ofapplication and the lip glue should be applied in 12-15mm beads.On a rendered stack with a top ring fitted (see p.12 forexample), where a straight chimney passes through afloor or roof, zero mm distance to

Schiedel Isokern DM block system is a high quality System Chimney. The . The Magnum Firechest provides the opportunity to create fire openings up to 1.2m wide. . 130709 DM36 45º flue entry kit (four parts) 500mm high 42 156.14 126363 150mm i/d 255 x 255 starter flue block 125mm high 4 22.91

Related Documents:

Isokern Pumice Double Module DM is CE Certified to EN1858 TÜV Cert no. 0036 CPR 90219 001 Isokern Pumice Chimney Liner is CE certified to EN1857 TÜV Cert no. 0036 CPR 90219 002 Isokern Magnum Firechest has been tested at the Fraunhofer Institut, Stuttgart, Cert no. P8-094/2006

Isokern Pumice Double Module DM is CE Certified to EN1858 TÜV Cert no. 0036 CPD 90219 001 Isokern Pumice Chimney Liner is CE certified to EN1857 TÜV Cert no. 0036 CPD 90219 002 Isokern Magnum Firechest has been tested at the Fraunhofer Institut, Stuttgart, Cert no. P8-094/2006

THE ISOKERN MAGNUM SERIES (ALL FUEL) Fan the flames of innovation and take your fireplace to new heights. The Isokern Magnum Series Fireplace System product line offers the largest openings available in the market, with finished width openings of 36”, 42”, 48”, 60” & 72”.

The Schiedel Isokern range of firechests are supplied as flat packs. They can be easily and quickly constructed to produce a neat and pre-formed fire opening ready for finishing. The Magnum Firechest provides the opportunity to create fire openings up to 1.2m wide. The Schiedel Isokoat system is an efficient and cost effective method of re-sealing

View price list items in Xactimate There are many different ways to view price list items in Xactimate. This is only one possible method. 1. Open Xactimate. 2. Click the Price List tab. 3. Double click a price list. For the most recent price list, click Request Price List(s) and follow the steps in the dialog box. 4. Select All Items List.

EBC 30 controller XTP Sensor Clothes Dryers This is a unique fi replace and exhaust system for common venting of multiple ISOKERN gas-fi red fi replaces in residential, multistory buildings. The system is composed of multiple ISOKERN B-Vent fi replaces and one or more EXHAUSTO RSV fans,

Isokern Standard Series: 36 54’-0” 42 40’-0” 46 41’-0” Magnum Series: 28 50’-0” 36 54’-0” 42 40’-0” 48 41’-0” For heights above those listed above, consult a structural engineer for additional structural support for the DM chimney system. These heights do not reflect information regarding metal flue.

ASTM C 1702 – Heat of hydration using isothermal calorimetry Heat of Hydration. is the single largest use of isothermal calorimetry in the North American Cement industry Other major applications include . Sulfate optimization . and . admixture compatibility Several Round Robins in North America and Europe on Heat of Hydration .