Cross Reference RA Part Number: 700-FSM3UU23 B

2y ago
21 Views
3 Downloads
1.12 MB
5 Pages
Last View : 9d ago
Last Download : 3m ago
Upload by : Maxton Kershaw
Transcription

(With SPDT 1 C/O contacts)Operating ModeContact OutputTiming Range0.05 s 1 sOne Shot / Watch Dog(Pulse Controlled)(SPDT) 1 C/OInput Voltage0.5 s 10 sCat. No.700-FSK3AU23-EX24 48V DC24 240V AC50/60 Hz700-FSK3CU23-EX4Multi-Function(This device allows the flexibility of selecting one of 8 single timing functions.)Operating ModeMulti-function timing relays8 Single-functions:A, B, C, D, E, F, I, and LON and OFF function additional(for installation and maintenance)note: See connection diagrams for furtherdescription.Contact OutputTiming RangeInput VoltageCat. No.(SPDT) 1 C/O12V DC700-FSM3UZ12(SPDT) 1 C/O24 48V DC24 240V AC50/60 Hz700-FSM3UU2312V DC700-FSM4UZ1224 48V DC24 240V AC50/60 Hz700-FSM4UU230.05 s 60 hr(DPDT) 2 C/O(DPDT) 2 C/O356Note: Information for hazardous location versions of this product (-EX) is available on the Industrial Controls Catalog website: www.ab.com/catalogs.7Multi-Function With Hazardous Location Certification (This device allows the flexibility of selecting one of 8 single timing functions.)Operating ModeM Multi-function timing relays8 Single-functions:A, B, C, D, E, F, I, and LON and OFF function additional(for installation and maintenance)Note: See connection diagrams for furtherdescription.Contact OutputTiming Range8Input VoltageCat. No.700-FSM3UU23-EX(SPDT) 1 C/O24 48V DC24 240V AC50/60 Hz0.05 s 60 h1(DPDT) 2 C/O700-FSM4UU23-EX910 Temp. CodeT4A 2A32VDCMAX.II 3 G, EEx nL IIC T4 DEMKO 04 ATEX 0404974X2A 32VDC MAX. Ta 70 C11Ind. Cont. Eq. for Hazardous Location Listed 87SLClass 1, Div. 2, Groups A,B,C,D Class 1, Zn 2, Group IICMounting: Product shall be installed in an enclosure constructed in accordance with the requirements of EN50021.1213www.ab.com/catalogsPreferred availability cat. nos. are bold.Publication A117-CA001A-EN-P9-67

Bulletin 700-FSDIN Rail Mounted Timing RelaysProduct Overview/Product Selection01Bulletin 700-FS — High Performance Timing RelayTable of Contents Adjustable function and timing range timing relays DIN Rail mounted without cost of socket 22.5 mm wide multi-function or single functions Available as SPDT or DPDT contact output, 8 A Timing Ranges From 0.05 s 60 hr Coil surge protection Hazardeous location version availableProduct Selection . 9-67Accessories. 9-68ConnectionDiagrams. 9-69Specifications. 9-72Standards Compliance andCertificationsSee Specification table in thissection, 9-72.2Catalog Number Explanation3700 – FSBulletin NumberType eInputVoltageSingle-Function (With SPDT 1 C/O ng ModeContact OutputTiming RangeInput VoltageCodeDescriptionAll functions:CodeDescriptionCodeAOn-delay1A0.05 1 sZ1212V DCBOff-delay13 Onechangeovercontact (SPDT)B0.15 3 sU2324 48V DC24 240V AC 50/60 Hz1 C/OCOn- and off-delay1C0.5 10 sDOne shot1D1.5 30 sEFleeting off-delay1E0.05 1 minFFlasher (repeat cycle startswith pulse)1F0.15 3 minGFlasher (repeat cycle startswith pause)1IG0.5 10 minH1.5 30 minOn-delay pulse generator1I0.05 1 hrJOn-delay (pulsecontrolled)1J0.15 3 hrK0.5 10 hrKOne shot/watch dog (pulsecontrolled)1L3.0 60 hrU0.05 s 60 hr LPulse converter1MMulti-Function Multi-Range1 Preferred availability item. Valid for functions "A" and "B" only.1213www.ab.com/catalogs9-66Preferred availability cat. nos. are bold.Publication A117-CA001A-EN-PDescription

Bulletin 700-FSDIN Rail Mounted Timing RelaysSpecificationsSpecifications01234567Time Characteristics (according to VDE 0435, Part 2021)Setting Accuracy 5% of full scaleRepeatability 0.2% of the setting valuesToleranceVoltage: 0.001%/%ΔUTemperature: 0.025%/ CGeneral DataInsulation Characteristics2 kVAC/50 Hz test voltage accordingto VDE 0435 and 6 kV 1.2/50 μs surgevoltage according to IEC 947-1between all inputs and outputsEMC/Interference ImmunityPerformance of following requirements:Surge capacity of the supply voltageaccording to IEC 1000-4-5: 4 kV1.2/50 μsBurst according to IEC 1000-4-4: 6 kV6/50 nsESD discharge according to IEC 10004-2: Contact 8 kV, air 8 kVElectromagnetic HF field according toIEC 801-3 and conductedelectromagnetic HF signal according toIEC 801-6: Level 3EMC/EmissionElectromagnetic fields according to EN55 022: class BSafe IsolationAccording to VDE 106, part 101Climatic Withstand56 Cycles (24 hr) at 25 40 C and95% relative humidity according to IEC68-2-30 and IEC 68-2-34 g in three axes at 10 500 Hz, testFC according to IEC 68-2-6SupplySupply Voltages24 48V DC and 24 240V AC,50/60 Hz (multi voltage)Voltage Tolerance–20 20% (DC), –15 10% (AC)Power Consumption0.5 W at 24V DC, 5 VA at 240V ACTime Energized100%Reset Time50 msVoltage Interruption 20 ms without reset (supply voltage)Input ImpedanceRelay ON: 3K-13K ohmsRelay OFF: 0.7K-4K ohmsCable Length (Supply VoltageControl)Max. 250 m (800 ft)Pulse Control (B1)Pulse Duration 50 ms (AC), 30 ms (DC)Vibration ResistanceInput VoltageSupply voltage rangeShock Resistance50 g according to IEC 68-2-27Input Current1 mAMax. Leakage Current400 micro AmpsProtection ClassEnclosure:IP 40IP 30 (Single-function)Terminal:IP 20 according to IEC 947-1Max. 250 m (800 ft) without parallelload between B1 and A2Max. 50 m (160 ft) with load ( 3 kΩ)between B1 and A2Weight100 gCable LengthOutputsContact TypeRelay as changeover switchDielectric Coil to ContactWithstand Voltage5000 VVoltage: 440V ACCurrent Ith (AC-1): 8 A (5 A for 700FSQ)ApprovalUL, C-ULAmbient TemperatureOpen: –25 60 CEnclosed: –25 45 CStorage: –40 85 CTerminalsScrew terminal M3.5 for Number 2Posidrive, Philips, and slotted screws.Suitable for power screwdriver. Ratedtightening torque 8.8 lb.-in. (0.8 N m,max. 1.2 N m).Dual-chamber system for terminalcross-sections of 1 x 0.5 mm2 2 x 2.5mm2 (solid) or stranded 2 x 2.5 mm2(flexible with sleeve), #20 14 AWG.Finger protection according to VDE0106.MountingFront mounting; For snap-on mountingon 35 mm DIN Rail or screw fixing byadapter and 2 screws (M4 type)DisposalSynthetic material without dioxinaccording to EC/EFTA notificationNumber 93/0141/D electrical contactswith cadmiumCertificationscULus Listed (File No. E14840, GuideNKCR/NKCR7), CE MarkedStandardsEN/IEC 60947-1, EN/IEC 60947-5-1,UL 508, CSA 22.2 No. 14Power: 2000 VA8According to IEC 947-5-1:Switching Capacity3 A/440V AC (inductive load, AC 14)3 A/250V AC (inductive load, AC 15)1 A/24V DC (inductive load, DC 13)According to UL 508:91.5 A/250V AC (B300)3 A/120V AC (B300)Short-Circuit Resistance10 A gLMechanical: 30 million operations10Electrical operations:4 Mil. at 1 A/250V AC, cos φ 10.2 Mil. at 6 A/250V AC, cos φ 11.5 Mil. at 1 A/250V AC, cos φ 0.311Life1 Performance Data — See this catalog, Important- 3.0.3 Mil. at 3 A/250V AC, cos φ 0.3Temp. Code T4A2A 32VDC MAX.0.5 Mil. at 6 A/24V DC, resistive2 Mil. at 4 A/24V DC, resistive2 Mil. at 0.2 A/230V DC, resistive1 Mil. at 0.4 A/24V DC, L/R 20 ms12Mounting: Product shall be installed in an enclosure constructed inaccordance with the requirements of EN50021.1 Mil. at 0.2 A/110V DC, L/R 20 ms1 Mil. at 0.1 A/230V DC, L/R 20 msState Indicator1 LED, combination signal13www.ab.com/catalogs9-72Preferred availability cat. nos. are bold.Publication A117-CA001A-EN-P

Bulletin No. 700-FE 700-FS 700-HR52, -HRP,-HRS, -HRT, -HRV 700-HRM/-HRC 700-HRF Type DIN Rail Timer DIN Rail Timer Multifunction Timer On-Delay Timer Twin Timer Features Only 17.5 mm wide

Related Documents:

Cross Reference Hoffman to Hammond Cross Reference This Cross Reference is a guide only. Products may not be exactly the same and it is user’s responsibility to verify details for acceptable subsitution. Hammond is not responsibile for cross reference errors.File Size: 200KBPage Count: 22

Cross Reference This Cross Reference is a guide only. Products may not be Wiegmann to Hammond Cross Reference exactly the same and it is user’s responsibility to verify details for acceptable substitution. Hammond is not responsible for cross reference errors.

Cross Reference This Cross Reference is a guide only. Products may not be exactly Hoffman to Hammond Cross Reference the same and it is user’s responsibility to verify details for acceptable subsitution. Hammond is not responsibile for cross reference errors.File Size: 382KBPage Count: 17

a. Type in 99500 in the strong Case /strong Cross Reference Number box. b. Click on strong Case /strong Cross Reference Type drop down menu and select Cook County Attorney Code. c. Click Add strong Case /strong Cross Reference Number. d. Click Save Changes. If you are trying to file a motion, type the word Motion in the strong Case /strong Cross Reference Number box and select Motion in the drop down .

Types of cross stitch Cross stitches are created on a matrix of squares or ‘pixels’. Any part of the square can be stitched, from the edges to the diagonals. The full range of cross stitches is listed below. Cross stitch fills When using cross stitch as a fill you can select from any of the cross stitch fill types. Full cross stitch

Cross-Reference Guide To determine a replacement part number for your belt tensioner, simply locate your original part number in the cross-reference and look at the column marked “PolyForce #” for your new part number For authorized PolyForce distributors wishing to build a modular

The source of a cross-reference is the information that identifies what is being referenced. For example, if a cross-reference reads See Chapter 9, "Ain't Life Grand," on page 77 the Chapter 9 heading is the source for that cross-reference. If a cross-reference reads Figure 9.3 on page 7

Part No : MS-HTB-4 Part No : MS-HTB-6M Part No : MS-HTB-6T Part No : MS-HTB-8 Part No : MS-TBE-2-7-E-FKIT Part No : MS-TC-308 Part No : PGI-63B-PG5000-LAO2 Part No : RTM4-F4-1 Part No : SS 316 Part No : SS 316L Part No : SS- 43 ZF2 Part No : SS-10M0-1-8 Part No : SS-10M0-6 Part No : SS-12?0-2-8 Part No : SS-12?0-7-8 Part No : SS-1210-3 Part No .