ASO SPAE SAE SHED MODEL 15151S

2y ago
12 Views
2 Downloads
743.71 KB
20 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Sasha Niles
Transcription

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHAU: 1800 029 701N Z: 0800 466 444admin@absco.com.auwww.abscosheds.com.auAbsco IndustriesPremier Shed Model: 23151GKFRONT: 2.26mSIDE:1.52mHEIGHT: 60mWHEN LAYING YOUR CONCRETEFor construction in non-cyclonicareasSLAB, ENSURETHERE IS AEDGE 25mm DEEPWind rating: N2 as per REBATEDAS4055-2012AROUND THE PERIMETERREBATED EDGEEETCRNCO100mmWhen laying concreteslab,HELPensureTHIS WILLWATER thereEGRESSFROM THEBASEOF THE SHEDis a rebated edge 25mmdeeparoundtheperimeter. This will help water egress fromthe base of the shed.BOTTOM CHANNEL75mm WIDE REBATECONCRETE SLABWe thank you for choosing an Australian madeshed. For further assistance please visit our detailedinstructional video library atMANU FA CT URED Http://www.abscosheds.com.au/watch-videosDownload the AbscoSheds Assembly AppAt ABSCO Industries we are always looking to benumber ONE, so please let us know what you thinkfor instructional videosof our instructions. Feedback makes us better.IN A US TR ALIAfeedback@absco.com.auSNAPTiTEAssemb lyABSCO INDUSTRIESAbsco IndustriesASSEMBLY INSTRUCTION MANUALAssembly Instruction ManualSHED MODEL: 23151GKModel: 15151SK14/08/1821-11-2017PAGE 011.21

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHGENERAL INSTRUCTIONS Before commencing any assembly, read through these instructions in detail to gain a thoroughunderstanding of assembly methods and associated details. Unpack the carton and carefully identify and check off all the parts against the parts describedand illustrated on "COMPONENTS PACKING LIST" pages.SITE PREPARATION The site for the shed must be level. An uneven surface may result in misalignment of parts. The shed shall be erected on top of a reinforced concrete slab and anchored down appropriatelyillustrated on “FINAL CONSTRUCTION” page.10mm drill bitmetal/masonry3mm drill bitTOOLS REQUIREDSAFETY NOTES Some parts may have sharp edges. It is advisable to wear gloves when handling these items andsafety glasses if drilling holes. Sensible shoes are highly recommended. Do not erect your shed in windy conditions. Ensure that the shed is securely anchored to a solid foundation immediately after construction iscompleted. It is highly recommended to erect the shed with two or more people.RECOMMENDEDAbsco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.22

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHCOMPONENT PACKING LISTCheck off all components.QTYCOMPONENTDESCRIPTIONSTEEL SHEET2045 X 773mm2PARTCHECK QTYNo.26211STEEL SHEET1915mm X 773mm260L11STEEL SHEET1915mm X 773mm260C1261L1261R411STEEL SHEET2045mm X 773mmSTEEL SHEET2045mm X 773mm2STEEL SHEET1610mm X 773mm43S11STEEL SHEET1785mm X 711mm34A21STEEL SHEET1725mm X 773mmB1Absco IndustriesAssembly Instruction ManualCOMPONENTDESCRIPTIONCHANNELL 1513mm53BB535353CCCHANNELL 1513mmF81FE81ECHANNELL 1513mm81CHANNELL 1513mm8180AA80CHANNELL 1785mmD61CHANNELL 1530mmCHANNELL 783mmModel: 15151SK79CHECK53AA53CHANNELL 1513mmPARTNo.C14/08/1861D79C1.23

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHCOMPONENT PACKING LISTQTY1121COMPONENTDESCRIPTIONA58CHANNEL WITH HINGESL 1725mmCHECK QTY58A58BB5584HCHANNELL 1725mm58CCH5584CHANNELL 773mmPart No. HerePARTNo.89AH54JAMB L 1785mm1122COMPONENTDESCRIPTIONPARTNo.CHECK89BPart No. HereJAMB L 1785mm90CPart No. HereJAMB L 783mm91APart No. HereJAMB L 1120mm8888JJLIP TRIM L 1610mmINSTRUCTIONS & FITTINGS PACKET1ASSEMBLYINSTRUCTIONS6SELF TAPPING SCREWSL 20mm1SELF TAPPING SCREWSPACKET CONTAINING 100PSTKSGLSINGLE DOORFITTINGS PACK1DOORSTRAPL: 165mm112APSTKSGL - SINGLE DOOR FITTINGS PACK111DOORPADBOLT3mm DRILL BITFAST0061DRILL1SELF TAPPING SCREWSPACKET CONTAINING 220DOORPADBOLTHASPFAST007PHILLIPS DRIVER BIT1FAST038PACK 6PSCREW PACK 6PACK 6P - SCREW PACK 66Absco Industries3/16 COUNTERSUNKSCREWS & NUTSAssembly Instruction Manual6Model: 15151SK3.2 x 8mmBLIND POP RIVETS14/08/181.24

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHSNAPTiTE ASSEMBLY GUIDEThe Snaptite Assembly System locks end channels to all roof and wall sheets without the need fortools and fasteners.To assemble each panel, the perimeter channels are secured to the top and bottom of each panel.Gently tap the channel over the SNAPTiTE lugs on the sheet, working along the sheet.Each perimeter channel must finish flush with the edges of the sheets. Simply tap the channel alongthe sheets until each end is neatly flush. If you need to remove channels from the panels, slide it offfrom the side.Channel locks the shed panel intoposition without the need for screws!FASTENING SYMBOLSSNAPT iTESecure channel to sheeting by SNAPTiTEfastening method.Join components together with onescrew at this location only, as somechannels have extra holes that are notrequired for this model of shed.Do not join components together atthis location yet, as the screws mayobstruct further assembly of the othercomponents.Absco IndustriesAssembly Instruction ManualDJoin components together by pre-drilling the holes first. Use one component astemplate to mark where the holes are anddrill with a 3mm drill bit.3mm pop rivet4mm nut and bolt set.Model: 15151SK14/08/181.25

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHAbsco Industries88J43S81EOVERVIEW OF ROOF COMPONENTS43S88J81EOVERVIEW OF ROOF COMPONENTSAssembly Instruction ManualModel: 15151SK14/08/181.26

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mH79C53B89B260C261R26280A262Absco IndustriesAssembly Instruction Manual81E81F61D53COVERVIEW OF WALL W OF WALL COMPONENTSModel: 15151SK14/08/181.27

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHREAR PANEL ASSEMBLY1x required26226253CSNEAPT iT81FSNAbsco IndustriesAssembly Instruction ManualModel: 15151SKEAPT iT14/08/181.28

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHSIDE PANEL ASSEMBLYWith door mullion (80A) attached.80A260C261R61DAP TESN T i81ETEAPT iSNAbsco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.29

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHSIDE PANEL ASSEMBLYWithout door mullion.261L260L61DTEAP T iSN81ESNAbsco IndustriesAssembly Instruction ManualModel: 15151SKEAPT iT14/08/181.210

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHROOF PANEL ASSEMBLY43S43S88J81EEAPT iTSN88JAbsco IndustriesAssembly Instruction ManualEAPT iTSNModel: 15151SK14/08/1881E1.211

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHFRONT PANEL ASSEMBLYSNEAPT iT53A34A89A89AEAPT 90C79B5389BC79B5389BC79B5389BAbsco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.212

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHDOOR PANEL ASSEMBLYSINGLE DOOR58CSNAPT iTED58ADDB58BD12ASNAPT iTE58CVertical door channels areinstalled in the oppositeorientation compared to thehorizontal door channels.BLongflange ofchannelAbsco IndustriesShort flangeof channelAssembly Instruction ManualModel: 15151SK14/08/181.213

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHDOOR PANEL ASSEMBLYSINGLE DOOR PANEL91A91ABNOTE: Nuts and bolts are alsosupplied and may be used instead ofrivets. Use a 4mm drill bit to enlargethese holes in the jambNOTE: The holes to fasten the padbolt hasp are notpre-punched to allow for proper alignment. Positionthe hasp centrally over the padbolt shaft and drill 3mmholes and secure with screws.Absco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.214

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHPANEL CONSTRUCTIONNOTE: Take care to ensure that all wall panels are not upside down. The top channels of each panelare pre-punched for attaching roof sheeting. The base channels are not pre-punched.DDDDDDD260C80AD89BDReplace padbolt hasp 10mm screwswith 20mm screwsConnect door mullion sections with six20mm screwsSide wall channels fit into thenotched rear wall channels.Absco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.215

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHFINAL CONSTRUCTIOND250510510250D250250ANCHORING OF SHEDLocation of 9concrete anchorsDD250480250250DDDDDDBolt and Nut*M10 4.6/SSteel Angle*35 x 35 x 3Each anchor consists of one nut, bolt, M10dynabolt and steel angle.Drill a 10mm hole into the wall sheet.Drill a 10mm hole into the concrete.M10 Dynabolt*Wall SheetSlab* Denotes hot dip galvanised finishAbsco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.216

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHAbsco Skillion Roof Shed NotesGeneral 1.G This instruction manual shall be read in conjunction with other consultants drawings, specifications andwritten instructions provided by Absco and/or their representatives. 2.G The drawings provided herein are for installation and structural engineering purposes only. If discrepanciesare discovered within the documentation provided, these shall be brought to the attention of Absco andwritten approvals obtained prior to commencing the affected section of work. 3.G If in doubt ask. 4.G Until approvals from the local authorities are obtained, commencement of construction from thesedrawings shall not commence. 5.G Unless varied by the project specification, all materials and workmanship shall be undertaken inaccordance with the relevant Australian standards and the by-laws and ordinances of the relevant buildingauthorities. 6.G All dimensions indicated in these drawings shall be verified on site by the installation contractor. Scalingof drawings shall not be undertaken. 7.G Prior to commencing works on site, the contractor shall verify the position of all services in the area toensure that the construction does not interfere with any of those services. 8.G During installation on site the shed structures shall be maintained in a stable condition with no partbecoming overstressed or permanently deformed. 9.G In circumstances where the shed has been installed in a manner which is inconsistent with the installationmanual, structural certification shall be void. 10.G The structural components detailed within this installation manual have been designed for the followingloads in accordance with AS/NZS1170 based on a Class 10a, Type 2 structure: Roof Live Load: 0.25 kPa uniformly distributed or 1.1 kN concentrated as per AS/NZS1170.1 Wind Load: Classification N2, Non-Cyclonic to AS4055 where Vu 40 m/s, Vs 26 m/sWindward wall Cpe 0.7Leeward Wall Cp,e -0.3 to -0.5 as applicable based on shed geometrySide Wall Cp,e -0.5 to -0.65 as applicable based on shed geometryRoof Cp,e -0.5 to -1.3 depending on wind direction6-12 Activity St, Acacia Ridge QLD 4110PO Box 119, Acacia Ridge QLD 4110Absco IndustriesAssembly Instruction ManualAU: 1800 029 701N Z: 0800 466 444Model: 8/181.217

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHAbsco Skillion Roof Shed NotesSteelwork 1.S All structural steelwork shall have a corrosion protection system applied consistent with AS/NZS 23122002. 2.S All structural steelwork detailed within this installation manual shall be minimum Grade 550 for roll formedsections (including roof and wall sheeting) and Grade 250 for angle sections. 3.S All roof, and wall sheeting shall be minimum base metal thickness of 0.3mm 4.S All snaptite channels and jambs shall be minimum base metal thickness of 0.42mm 5.S All top hats shall be minimum base metal thickness of 1.0mm 6.S All screw fasteners shall be Phil Pan Head Zinc Plated #8 x 3/4” (STP0820) 7.S All bolt fasteners for anchoring shall be M10 minimum grade 4.6/S 8.S Installation of screw fasteners shall generally be undertaken in accordance with the relevant provisionsof AS1562.Supporting Slab and Foundations 1.F The supporting slab foundation for the garden shed shall be of a minimum size indicated on the installationmanual. The top surface of the formed slab shall be level and free of any irregularities which would inhibitthe installation of the shed. 2.F The structural engineering design for the supporting slab foundation shall be undertaken by a suitablyqualified structural engineer. The design shall consider all relevent provision of AS3600 and AS2870. 3.F Between adjacent footings or excavations, the contractor installing the slab foundation shall not exceeda rise of 1 in a run of 2 in line of slope. 4.F Unless approved in writing by the slab foundation engineer, the limits of excavations near existingfootings shall be in accordance with that indicated below.The contactor shall undertake ngs to ascertain their depth prior toexcavating adjacent to them. It is noted thatexcavating to a depth below that indicatedabove shall not be undertaken withoutthe written approval from the engineer.Absco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.218

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHAbsco Sheds Storage Guidelines Absco Sheds are designed to be weatherproof for normal weather conditions. In the event of extremeweather conditions such as heavy rain, combined with high wind gusts, the ridge capping, sheeting joins,screw fixings etc., may exhibit minor deformations which may allow some water entry. These areas should bechecked regularly to ensure that maximum strength and protection is maintained. Other weather conditions such as extreme heat and extreme cold, moist or dry air can influence the effectsof concrete floor moisture and/or condensation on the underside of the roof sheets. Absco Sheds and storage units are primarily used for storage of garden equipment such as lawnmowers,wheelbarrows, garden tools etc. Storage items that might be adversely affected by any of the above conditionsmay require additional protection such as being sealed or covered by plastic sheets and/or stacked abovethe concrete floor on timber slats. Waterproof sealants may be used to offer further protection where required around joins and screw fixings,as can rubber door seals and other products which are available from most hardware outlets. Placement of waterproof sealants (silicone) between the base of the shed and concrete slab is notrecommended, as this process can have a reverse effect, preventing excess water from escaping, resultingwith water accumulating and being trapped inside the shed. Absco accepts no responsibility for water entry, floor moisture, condensation or the condition of the Contentsinside your Absco steel building arising from any of the pre-mentioned weather conditions.6-12 Activity St, Acacia Ridge QLD 4110PO Box 119, Acacia Ridge QLD 4110Absco IndustriesAssembly Instruction ManualAU: 1800 029 701N Z: 0800 466 444Model: 8/181.219

ABSCO SPACE SAVER SHEDMODEL: 15151SK1.52mW x 1.52mD x 1.80mH, 2.08mHAustralia Product Warranty Against Defects Absco Sheds, including garden sheds, garden beds, aviaries, storage units, garages, awnings and carportsare made using high quality Australian made steel. We are pleased to advise we warrant that the steel coating will not rust, crack, flake peel or blister for 30years from date of purchase, when installed within Australia. This warranty does not apply to surface deterioration of panels caused by ‘Swarf” (Tiny particles ofsteel debris left from cutting, grinding or drilling operations) that has not been removed after buildingconstruction, or as a result of contact with damp soil, chemicals, fertilisers or other corrosive substances. This warranty covers any Absco product used for normal domestic use and installed in accordance with theinstallation instructions. The warranty does NOT cover Damage caused by storms, wind, rain snow or poor foundations. This warranty does NOT cover ABSCO products installed in severe coastal, industrial or other highlycorrosive environments. The warranty does not cover fasteners (screws, nuts, bolts, rivets, hasps or slidingpadbolts). The warranty is limited to replacement and delivery of components and does not include any labour orinstallation costs. The benefits given by the warranty are in addition to your other rights and remediesunder a law in relation to the goods or services to which the warranty relates. The warranty applies to the exclusion of all other representations, guarantees or warranties express orimplied, our goods come with guarantees that cannot be excluded under the Australian consumer law andis not transferable. You are entitled to a replacement or refund for a major failure and for compensationfor any other foreseeable loss or damage. You are also entitled to have the goods repaired or replaced ifthe goods fail to be of an acceptable quality and the failure does not amount to a major failure. For furtherinformation go to http://www.consumerlaw.gov.au Please retain a proof of purchase (sales docket or invoice) or register your warranty within 30 days ofpurchase here: www.absco.com.au/register warranty.php In the unlikely event a warranty claim is made, it must be supported by photographic evidence and detailsof the defect, including component part numbers, together with proof of purchase documentation (oron-line registration of purchase) and forwarded to the address below. Upon receipt of the warranty claim,the Customer Service Manager will contact you within three business days to advise you of the assessmentoutcome of the claim, which may include your expenses incurred in making the claim.THE CUSTOMER SERVICE MANAGER, ABSCO INDUSTRIES, PO BOX 119 ACACIA RIDGE QLD AUSTRALIA 4110PHONE: 1800 029 701 FAX: 07 3344 1191 EMAIL: warranty@absco.com.auIssued 01 January 2018Absco IndustriesAssembly Instruction ManualModel: 15151SK14/08/181.220

ASO SPAE SAE SHED MODEL 15151S 1.52mW x 1.52mD x 1.80mH, 2.08mH Model: 15151SK 14/08/18 1.2 1 . The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately . slide it off from the side. Channel locks the shed panel into position without the need for

Related Documents:

ASO SPAE SAE SHED MODEL 30152SEO 3.00mW x 1.52mD x 1.80mH, 2.08mH Model: 30152SECOK 18/11/18 1.4 1 . The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately . slide it off from the side. Channel locks the shed panel into position without the

ASO SPAE SAE SHED MODEL 23151S 2.26mW x 1.52mD x 1.80mH, 2.08mH Model: 23151SK 14/08/18 1.2 1 . The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately . slide it off from the side. Channel locks the shed panel into position without the need for

Rotella T5 SAE 10W- 30 Rotella T5 SAE 15W- 40 Rotella T4 SAE 15W- 40 / SAE 10W- 30 Rotella T3 / T2 SAE 15W- 40 Mobil Delvac Extreme SAE 10W- 30 Mobil Delvac Extreme SAE 15W- 40 Mobil Delvac 1300 Super SAE 15W- 40 / SAE 10W- 30 Mobil Fleet SAE 15W- 40 Premium Blue 8600 ES SAE 10W-

Supervised Agricultural Experience (SAE) Grant Review Rubric Overview of Scoring Category Corresponding Section Total Points Possible Points Received 1. SAE Plan SAE Description 15 2. SAE Plan Goals for SAE 15 3. SAE Plan Timeline 15 4. SAE Budget SAE Budget 15 5. Budget Narratives Resource and Collaboration Assessment 15 6. Budget Narratives

Plans from CheapSheds.com Single slope lean to style shed plans with porch in 45 sizes Deluxe gable roof shed plans with loft in 31 sizes Tall barn style shed plans with loft in 31 sizes Gable roof shed plans in 21 sizes Compact vertical bike shed plan How To Build a 1-2-3 Car Garage, Garage Plans How To Start A Business e-Book All

SAE W for emergency, maintenance and service vehicles; (e) SAE Standard J845 applies to 360-degree emergency warning lamps marked SAE W3; (f) SAE Standard J1318 applies to 360-degree gaseous discharge lamps marked SAE W5; (g) SAE Standard J581 applies to driving lamps marked SAE Y. (2) A lamp on a vehicle, wherever it is located,

specified in SAE J514, SAE J518, SAE J1453, SAE J1926/ISO 11926 and related standards. The working pressure ratings listed below are based on a 4:1 design factor for minimum burst. As specified . in SAE J514, these are dynamic pressure ratings and the fittings are capable of passing a cyclic endurance (im-

the transactions are difficult to discern. This makes it difficult to determine the overall size of activity and to know what the fair price is for a particular technology. And, of course, in highly inefficient markets a good deal of potentially valuable trade in innovation does not occur. The costs are so high and the potential value so difficult to perceive that innovation often sits “on .