Non-Metallic Surface RacewayPan-Way Non-Metallic Surface Raceway provides maximum flexibility for routing, protecting,and terminating high performance cabling systems. With today’s fast-track projects and design/buildjobs, selecting the best wiring method to support extensive data communications and power cablingis a real concern. As part of the Panduit Enterprise Solution, Pan-Way Surface Raceway offers a safe,convenient and attractive method for secure routing by modifying or extending existing installations. Itprovides connections to existing work areas without the expense of in-wall cabling.Panduit Surface Raceway is designed with attention to application and aesthetics to blend with anydécor. All Panduit raceway systems offer a full complement of transition and bend radius fittings thatfacilitate integration between systems. It is compatible with standard NEMA screw-on faceplates orsuperior Pan-Way Snap-On Faceplates, and a full line of junction boxes.Non-metallic Surface Raceway (Small Capacity)Low Voltage Single Channel Raceway (LD) LD is a one-piece raceway available in three sizes with adhesive backing Routes coaxial, fiber optic, and other low-voltage cables Full range of low voltage fittingsPower Rated Single Channel Raceway (LDPH and LDS; UL and CSA rated to 600V) LDPH is a tamper resistant two-piece raceway available in three sizes with pre-punched mountingholes and adhesive backing LDS is a tamper resistant solid piece design raceway available in two sizes with adhesive backing Full range of power rated fittingsPower Rated Multi Channel Raceway (LD2P10; UL and CSA rated to 600V) LD2P is a dual channel raceway with a flexible hinged cover and adhesive backing Suitable for routing data and power cables simultaneously Full range of power rated fittingsNon-metallic Surface Raceway (Large Capacity)T-45 Surface Raceway (UL and CSA rated to 600V) T-45 is a medium sized raceway with pre-punched mounting holes; multi-directional hinged coverallows access from both sides Optional divider wall available for running power and data simultaneouslyT-70 Surface Raceway (UL and CSA rated to 600V) T-70 is a large sized raceway with pre-punched mounting holes Optional snap-in divider wall for running power and data simultaneously Compatible with NEMA standard screw-on faceplates or Panduit snap-on faceplatesFor additional raceway solutions, please go to www.panduit.com.2

Non-Metallic Surface Raceway Selection GuideTable of ContentsLD Profile Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4LD Raceway Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4LD/LDPH/LDS/LD2P10 Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Standard LD Fittings for Low Voltage Applications . . . . . . . . . . . . . . . . . . 6Standard LD Fittings for Power Rated Applications . . . . . . . . . . . . . . . . . 7T-45 Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8T-45 Surface Raceway Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8T-45 Surface Raceway Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9T-70 Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10T-70 Surface Raceway Roadmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10T-70 Surface Raceway Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11T-70 Surface Raceway Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Faceplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Snap-On Faceplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Screw-On Faceplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Junction Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Fast-Snap Junction Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Power-Rated Junction Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15www.panduit.com3

Raceway Selection GuidePan-Way LD Profile RacewayLD/LDPH/LDS/LD2PDrop CeilingFittingTee FittingOutside CornerFittingInside CornerFitting4

Raceway Selection GuidePan-Way LD Profile RacewayPart NumberDescriptionLD3IW6-ALD Raceway is a single channel, one-piece hinged design ideal for lowvoltage applications.LD5IW6-ALDLD10IW6-APart NumberDescriptionLDS3IW10-ALDS Raceway is a single channel, solid design raceway ideal for data and power rated applications and requires the use of mounting straps.LDS5IW10-ALDS.75"LDPH3Internal .17 Sq. 41"1.52"1.02"LDPH5Internal Area .33 Sq. In.DescriptionLDPH10Internal Area .89 Sq. In.LDPH Raceway is a single channel, two-piece hinged design raceway ideal fordata or power rated applications. It is UL and CSA rated up to 600V.LDPH10IW6-APart NumberLD2P10IW8-ADescriptionLD2PH Raceway is a tamper resistant multi-channel one-piece hinged designraceway ideal for data and power applications. It is UL and CSA rated upto 600V.LD2P10All raceway listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).LD and LDPH Raceway available in 6, 8 and 10ft. lengths. LDS Raceway available in 10 foot lengths only. LD2P10 Raceway is available in 8 and 10 foot lengths.www.panduit.com5

Raceway Selection GuideStandard LD Fittings for Low Voltage ApplicationsCouplerCF3IW-ECF5IW-ECF10IW-XRight AngleRAF3IW-ERAF5IW-ERAF10IW-XInside CornerICF3IW-EICF5IW-EICF10IW-XOutside 10IW-XEnd CapECF3IW-EECF5IW-EECF10IW-X4-Way CrossCRFC5IW-XDrop Ceiling/Entrance EndDCF3IW-EDCF5IW-EDCF10IW-XFire Box AdapterFBA5IW-XFBA10IW-XReducerRF5X3IW-E From size 5 to 3RF10X3IW-X From size 10 to 3RF10X5IW-X From size 10 to 5One Inch Bend Radius Fittings for TIA ComplianceInside CornerICF3IW-XICF5IW-XICF10IW-XOutside CornerOCFX3IW-XOCFX5IW-XOCFX10IW-XRight -ETFC10IW-XAll LD Profile Raceway fittings are listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).All items highlighted in bold blue comply with TIA bend radius requirements.6

Raceway Selection GuideStandard LD Fittings for Power Rated ApplicationsCouplerCFX3IW-XCFX5IW-XCFX10IW-XRight AngleRAFX3IW-XRAFX5IW-XRAFX10IW-XInside CornerICFX3IW-XICFXIW-XICFXIW-XOutside W-XTFX10IW-XTee for LD2P10TFXD10IW-XEnd 103IW-XRFX105IW-XDrop Ceiling/Entrance EndDCEFXIW-XEntrance EndEEFXIW4-Way CrossCRFX5IW-XConduit Entrance EndCEFXIW-XRight Angle/Entrance EndRAEFXIW-XAdapter for LD3 andLD5 Size RacewayCA3IW-XCA5IW-XLD RacewayCutting ToolSRTAll LD Profile Raceway fittings are listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).All items highlighted in bold blue comply with TIA bend radius requirements.www.panduit.com7

Raceway Selection GuidePan-Way T-45 Surface RacewayT-45 Raceway RoadmapReducerFittingSnap-On HingedData Bracket8Offset Boxfor Snap-OnFaceplates

Raceway Selection GuidePan-Way T-45 Surface Raceway0.06[1.5]1.00[25.4]T-45Internal Area 2.12 Sq. In.Part NumberBaseT-45CoverDivider WallT-45 Raceway 00.26[6.6]DescriptionT-45 Raceway is a non-metallic multi-channel, two-piece, hingedcover design raceway ideal for routing data, voice, video, fiberoptic and power cabling. It is UL and CSA rated up to 600V.T-45 Raceway is available in 8 foot and 10 foot lengths.Cover CouplerT45CCIW-XRight AngleT45RAIWInside CornerT45ICIWOutside CornerT45OCIWReducer FittingT45RLDIWEnd CapT45ECIWTee FittingT45TIWTee Fitting InsertT45TDEntrance EndT45EEIWT-45 Raceway AccessoriesWire RetainerT45WR-XSnap-On HingedData BracketT45HDBIWTransition InsertT45TRIElectrical Bracket and Box Electrical Bracket and Boxfor Rectangular Outletsfor 106 Duplex OutletsT45HEGBIWT45HEBIWWorkstation Outlet Center Workstation Outlet Centerfor Screw-On Faceplates for Snap-On FaceplatesT45WCIWT45WC2IWT-45 Raceway is available with adhesive backing. Add “-A” at end of part number. Example: T45BIW8-A.T-45 Raceway and fittings are listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).www.panduit.com9

Raceway Selection GuidePan-Way T-70 Surface RacewayT-70 Raceway RoadmapRight AngleFittingTee FittingBackfeed Fitting10

Raceway Selection GuideT-70 Surface Raceway0.06[1.5]1.40[35.5]T-70Internal Area 5.15 Sq. In.Part NumberBaseT-70CoverDivider WallT-70 Raceway FittingsBase CouplerT70BCIW-XEnd CapT70ECIWCover CouplerT70CCIW-XEntrance EndT70EEIWT-70 Raceway CIW8T70CIW10T70DW8T70DW10T-70 Raceway is a non-metallic large capacity, tamper resistantand multi-channel two-piece raceway. It is UL and CSA rated upto 600V and is ideal for routing data, voice, video, fiber optic andpower cabling. T-70 Raceway transitions to T-45 and LD profileraceway for specific applications. T-70 Raceway is available in8 foot and 10 foot lengths.Outside ide CornerT70ICIWTee DividerT70TDDevice BracketScrew-On and Snap-OnT70DB-XStandard FaceplateBracket (Screw-On)T70SDB-X3-Sided Hanging Boxfor GFCIT70HB3GFCI-XOffset Box(Screw-On Faceplates)T70WCIW3-Sided Hanging Box(Screw-On and Snap-On)T70HB3-XHanging BoxT70HB-XWire RetainersT70WR-XTransition FittingInsertT70TRIRight AngleT70RAIWBackfeed FittingT70BFIWOffset Box(Snap-On Faceplates)T70WC2IWT-70 Raceway and fittings are listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).www.panduit.com 11

Raceway Selection GuideSnap-On FaceplatesLow Voltage – Classic Style without Labeling Can be used with T-70 Raceway and Fast-Snap Outlet Boxes Available in horizontal and vertical orientation with two and four portsT70FV2IWT70FH2IWUIT70FV2IWUIT70FH2IWUltimate ID Classic Style Faceplates Can be used with T-70 Raceway and Fast-Snap Outlet Boxes Supplied with clear station and port label covers Available in horizontal and vertical orientation with two and four portsClassic Faceplate Frame Faceplates (Compatible with CHS2**-X and CHS2S**-X) Can be used with T-70 Raceway and Fast-Snap Outlet Boxes Single gang vertical or horizontal faceplates accept MIni-Com Inserts Available in horizontal and vertical orientation with two and four w Voltage Faceplates – Standard NEMA Style Can be used with T-70 Raceway and Fast-Snap Outlet Boxes Available in 106 duplex or rectangular forcommunication applicationsT70PSIWPower Rated Faceplates – Standard NEMA Style Can be used with T-70 Raceway and Fast-Snap Outlet Boxes Available in 106 duplex or rectangular forelectrical/communication applicationsFaceplates are listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).12 Please visit www.panduit.com for additional faceplate styles.

Raceway Selection GuideScrew-On FaceplatesLow Voltage – Classic Style with Labeling Accepts Mini-Com Modules Includes label/label covers for easy port ssic Faceplate Frame System (Compatible with 1/2 or 1/3 Inserts) Accepts inserts (CHS2**-x) which snap in and out Available in single gang and double gang CHS2IW-X and CHS2SIW-X (sloped) are compatiblewith CBIW, CBIW-2G, FP2DCIW and FP2RCIWCBIWPower Rated – Duplex Style Screw-on single gang ordouble gang accepts 106duplex outlet for electricalapplications Available in stainless steel FP2DC** accepts Mini-Com Inserts for IW-XCPGIWCPNIW-XFP2RCIWERU20IW-XPower Rated – Rectangular Style Screw-on single gang ordouble gang acceptsrectangular outlet forelectrical applications FP2RC** accepts Mini-Com inserts for communicationapplicationsFaceplates are listed in IW (Off White). Other colors include: WH (White) and EI (Electric Ivory).Please visit www.panduit.com for additional faceplate styles.www.panduit.com 13

Raceway Selection GuideJunction BoxesFast-Snap Junction Boxes Assembles without the use of screws Compatible with snap-on faceplates Available in low voltage and power ratedJB1FSIW-A(D 1.62")JB1FSDIW(D 2.75")JBP1FSIW(D 1.62")Low Voltage Junction Boxes Compatible with standard NEMA screw-on faceplatesJBX3510IW-A(D 1.62")JB1IW-A(D 1.75")-A indicates product includes adhesive backing.Boxes are listed in IW (Off White). Other colors include: WH (White).14JB1DIW-A(D 2.75")JBP2FSIW(D 1.62")

Raceway Selection GuidePower Rated Junction Boxes Screw together junction boxes accept standard NEMA screw-on faceplates Accept standard NEMA screw-on faceplatesSingle Gang BoxesJBP1IW(D 1.75")JBP1DIW(D 2.75")JBP1EIW(D 1.00")Double Gang BoxesJBP2IW(D 1.62")JBP1IIW(D 2.27")Round Outlet BoxJBP2DIW(D 2.75")JBP2SIW(D 1.62")JBD1IWSingle gang pass-throughJBD2IWDouble gang pass-throughPSJBXIW(D 1.31")JBP1MR20IW(D 1.20")JBP1MD20IW(D 1.22")JBA-XRJBX3510IW(Diameter 5.48")(Depth 1.14")Accessories-A indicates product includes adhesive backing.Boxes are listed in IW (Off White). Other colors include: WH (White).www.panduit.com 15

Panduit Corp.World HeadquartersTinley Park, IL 60487800.777.3300www.panduit.com 2015 Panduit Corp.ALL RIGHTS RESERVED.SRSG02--WW-ENG12/2015

Non-metallic Surface Raceway (Large Capacity) T-45 Surface Raceway (UL and CSA rated to 600V) T-45 is a medium sized raceway with pre-punched mounting holes; multi-directional hinged cover allows access from both sides Optional divider wall available for running power and data simultaneously T-70

Related Documents:

OFR89-4000 4000 Series Raceway Transition Fitting 4000 4000 Series Raceway KEY Four-channel base of OFR Series Overfloor Raceway provides channels for multiple combinations of services. OFR Series Raceway features the lowest profile available in overfloor raceway systems. Tamper-resistant feature prevents unwanted access to raceway-provided .

OFR89-4000 4000 Series Raceway Transition Fitting 4000 4000 Series Raceway KEY Four-channel base of OFR Series Overfloor Raceway provides channels for multiple combinations of services. OFR Series Raceway features the lowest profile available in overfloor raceway systems. Tamper-resistant feature prevents unwanted access to raceway-provided .

-45 Light Gold Metallic/ Bronze Metallic-58 Silver Metallic/ Charcoal Metallic-91 Quartz Diamond Metallic/ Burgundy II-219 Silver Blue Metallic/ Ember Blue Metallic-609 Light Aqua Mist Metallic/ Dark Ivy-753 Mocha Frost Metallic/ Medium Brown Metallic 5126 Shown Full Scale. TOP: Shades

optimization and aesthetic installation, while supporting Pan-Way Snap-On Faceplates. This unique raceway also supports any NEMA standard screw-on faceplate with use of device bracket and can reduce to smaller profile raceway (T-45 or LD raceway). Modular Divider Wall (T-70, Twin-70, TG-70, and T-45)

and allows for interconnection between raceway systems. n Removable cover. Allows easy access to wiring for changes and additions. n One- and two-gang device boxes. Now you can wire devices into the raceway system, making 2400 Series Raceway an excellent choice for communication wiring. n Over the raceway boxes. Provides tremendous labor savings.

Surface Raceway System PAN-WAY Twin-70 Surface Raceway is an aesthetically pleasing multi-channel raceway that provides separate covers for communications and power cabling channels. Fittings have been designed to maintain the TIA/EIA required 1" minimum bend radius of Category 5 and Fiber Optic cabling. The raceway is tamper resistant to

Panduit Copper Cabling Systems Panduit offers a range of copper cabling solutions to fit the needs of all types of applications. From trading floors to operating rooms, classrooms to store fronts, Panduit's copper systems provide the infrastructure needed to support networks of all shapes and sizes.

The Audit and Accounting Thresholds . AAT is a registered charity. No. 1050724. 3. Accounting Threshold The . regulations apply in respect of financial years beginning on or after 1 January 2016 whereby the audit threshold and the accounting threshold have become the same for private limited companies. The requirements for a private limited company that is also a charity are different. Please .