Switches & Pilot Lights Signaling Lights Relays & Sockets .

2y ago
19 Views
2 Downloads
2.71 MB
22 Pages
Last View : 16d ago
Last Download : 3m ago
Upload by : Mariam Herr
Transcription

Switching & ControlsSwitches & Pilot LightsSelection Guides. 900General Purpose Terminal Blocks. 901BN/BNH Modular Terminal & Fuse Blocks. 901BN High Current Power Blocks. 905Signaling LightsBA One Piece Terminal/Fuse Blocks & SmallCurrent Power Blocks. 907BX Break-Out Modules. 917Relays & SocketsBlocksTimersTerminalContactorsTerminal BlocksTable of ContentsLED Machine Lighting - Pg. 1Automation & Sensing - Pg. 25Circuit Breakerswww.IDEC.com/terminalblocksSafety - Pg. 255Switching & Controls - Pg. 449Index - Pg. 933

Terminal BlocksSelection GuideDescriptionAppearancePageCurrentModular DIN RailTerminal Blocks90110A to 150AModular DIN RailFuse Holders90310A maximumOne-Piece Power Blocks(DIN rail and surface mount)905200A to 350AOne-Piece DIN RailTerminal Blocks90715A to 40AOne-Piece DIN RailFuse Holders90810A maximumDIN RailBreak-Out Modules9171A maximumKey features of IDEC terminal blocks include: SpecificationsCircuit BreakersTerminal BlocksContactorsTimersRelays & SocketsSignaling LightsSwitches & Pilot LightsSelection GuideMolded from UL94-V0 material with excellent flame- and shock-resistanceMounts on a standard 35mm DIN railMarking strips and dust covers are availableControl circuit, power circuits, and fuse blocks, are availableSectional or one-piece constructionInsulation Voltage600VDielectric Strength2,500V AC, 1 minuteInsulation Resistance100MΩ minimumOperating Temperature–25 to 55ºCOperating Humidity45 to 85% RH900www.IDEC.com

Terminal BlocksBNH/BNKey features: Signaling LightsUL RecognizedFile No. E78117Touch-down terminals with spring-loaded captive screwsJumpers available up to 50A modelFuse block with or without blown-fuse indicator in neon or LEDMounts on 35mm standard DIN railFile No. R9551701J9551516 (power blocks)R9650688 (dual-deck blocks)CSA CertifiedFile No. LR64803Relays & SocketsSpecificationsModelBNH10WSwitches & Pilot LightsBNH/BN SeriesBNH15MWBNH15LWBNH30WAppearance0.275” (7mm)0.315” (8mm)0.413” (10.5mm)0.472” (12mm)ApprovalsUL, CSA, TUVUL, CSA, TUVUL, CSA, TUVUL, CSA, TUVNo. of Poles1111Wire Sizes22 to 16 AWG22 to 14 AWG22 to 14 AWG18 to 10 AWG600V / 10A600V / 10A600V / 15A600V / h-downTouch-downTouch-down35mm DIN rail35mm DIN rail35mm DIN rail35mm DIN rail0.6 - 1.00.6 - 1.01.0 - 1.31.4 - 2.05.3 - 8.95.3 - 8.98.9 - 11.512.4 - (N-m)(in-lbs.)End PlateDIN Rail VCBNM7BNM7BNM7BNM7FiberglassBNM9BNM9BNM9BNM9End clipBNM3BNM3BNM3BNM3Ring Terminal JumpersBNJ16BNJ26WBNJ46BNJ56Fork Terminal JumpersBNJ16FBNJ26FWBNJ46FBNJ56FTerminal BlocksBNL-5BNC230Dust CoverContactorsTerminalsTimersWidth800-262-IDEC (4332) USA & CanadaCircuit Breakers1. BNDN1000 aluminum DIN rails are available in 1 meter lengths.2. Marking strips are sold in 1 meter lengths.3. Most jumpers are provided with 6 poles (except for BNH50W jumper that is 2-poles only).4. Remove the “H” in the terminal block part number for standard screw type (ex. BNH10W becomes BN10W).901

Terminal BlocksSignaling LightsSwitches & Pilot LightsBNH/BNSpecifications, continuedModelWidthApprovalsRelays & SocketsBN150WBNDH15W0.610” (15.5mm)0.787” (20mm)1.024” (26mm)0.315” (8mm)UL, CSA, TUVUL, CSA, TUVUL, CSA, TUVUL, CSA, TUVNo. of Poles1112Wire Sizes16 to 6 AWG16 to 4 AWG16 to 0 AWG22 to 14 AWG600V / 10ATerminals600V / 50A600V / 75A600V / 150ASizeM5M6M8M3TypeTouch-downHex boltHex boltTouch-down35mm DIN rail35mm DIN rail35mm DIN rail35mm DIN rail, surface2.6 - 3.73.9 - 5.410 - 13.50.6 - 1.023.1 - 32.834.6 - 47.988.8 - 119.85.3 - ountingTerminalTorque(N-m)(in-lbs.)End PlateDIN Rail StopBNC320BNC420BNC520BNC230 (top level)BNC240 (bottom 9End clipBNM3BNM3BNM3BNM3Dust ripConnecting Rods———BNR1 10.34” (265mm)BNR2 19.69” (500mm)Connecting Nuts———BNN1 (2 pieces)BNDL2Base Mount Brackets———Ring Terminal JumpersBNJ62 (2 pole)——BNJ26Fork Terminal Jumpers———BNJ26FW1. BNDN1000 aluminum DIN rails are available in 1 meter lengths.2. Marking strips are available in 1 meter lengths.3. Most jumpers are six poles (except for BNJ62 which is 2 poles only).4. Remove the “H” in the terminal block part number for standard screw type (ex. BNH50W becomes BN50W).Circuit BreakersTerminal BlocksContactorsBNH50W902www.IDEC.com

Terminal BlocksBNF Fuse BlocksModelBNF10SWBNF10NWBNF10DW0.591” (15mm)0.591” (15mm)0.591” (15mm)NoneNeon (100–300VAC)LED (24V DC)UL, CSAUL, CSAUL, CSASwitches & Pilot LightsSpecifications, continuedAppearanceBlown Fuse IndicatorApprovalsNo. of Poles111Wire Sizes18 to 10 AWG18 to 10 AWG18 to 10 AWGVoltage/Current600V/10A maximum600V/10A maximumM4M4M4TypeStandard screwStandard screwStandard screw35mm DIN rail35mm DIN rail35mm DIN railMounting(N-m)1.4 - 2.01.4 - 2.01.4 - 2.0(in-lbs.)12.4 - 17.812.4 - 17.812.4 - 17.8End PlateBNE20BNE20BNE20DIN Rail StopBNL-5BNL-5BNL-5———TerminalTorqueDust CoverMarking StripBNM7BNM71/4” x 1-1/4”(6.35 x 31.8mm)1/4” x 1-1/4”(6.35 x 31.8mm)TimersApplicable Fuse SizeBNM71/4” x 1-1/4”(6.35 x 31.8mm)Relays & SocketsTerminals600V/10A maximumSizeSignaling LightsWidth1. BNDN1000 aluminum DIN rails are available in 1 meter lengths.2. Fuses not included.ContactorsTerminal BlocksCircuit BreakersCanada: 888-317-4332 USA: 800-262-4332903

Terminal BlocksDimensionsBNH SeriesPart No.BNH30Wø4.2 min.6 max.4.5 min.1815.513When using C Rail: 50ø5.2 min.42.512.8 max.34.328.36.5 max.4.5 min.BN SeriesPart No.DiagramsBN75W5326BN150W22.52017ø8.5 min.90411 max.10 min.296 min.22.8 max.3531.725.78.5 238181286.7ø3.2 min.5 min.www.IDEC.com59.56.6 max.5 max.55.549.55.2 max.When using35-mm DIN Rai: 61Whem usingC Rail: 67ø4.2 min.11.3 max.3327When using C Rail: 59.552When using DIN Rail: 53.56343Circuit BreakersBNDH15W29.82623When using DIN Rail: 52When using C Rail: 5050.542.5When using C Rail: 5016.8 max.Part No.BNF10SWBNF10NWBNW10DW746333ø6.2 min.When using DIN Rail: 44ContactorsBN75WBN150WTerminal Blocks3.3 min.9.5 max.31.425.44 min.5 max.15.8129.6When using C Rail: 4436.529.523.55 max.3819.4When using DIN Rail: 38ø3.6 min.8.5 max.6.6 max.29.523.53.3 min.14.310.58.54824.411.38ø3.2 min.When usingC Rail: 4133.529.523.55 max.When using35-mmD IN Rail: 3533.55.8 max.381838186.733.5When using DIN Rail: 35Relays & SocketsBNH50WBNH50W5.9BNH15MW10.37ø3.2 min.When using C Rail: 41BNH15LWBNH15LWBNH30W3818When using C Rail: 41When using DIN Rail: 35Signaling LightsBNH10WBNH15MWTimersDiagramsBNH10WWhen using DIN Rail: 44Switches & Pilot LightsBNH/BN83.3 min.

Terminal BlocksBN Power BlocksSwitches & Pilot LightsBN Power Block SeriesKey features: Up to 350A are available for DIN rail or direct mounting onpanel surfaces 2, 3, 4 pole models availableCSA CertifiedFile No. LR64803Signaling LightsUL RecognizedFile No. E78117File No. J9551516SpecificationsBN200NW#(replace # with thenumber of poles)BN400NW#(replace # with thenumber of poles)BN200NW#K(replace # with thenumber of poles)BN400NW#K(replace # with thenumber of poles)See dimension table on page 906See dimension table on page 906See dimension table on page 906See dimension table on page 906UL, CSA, TUVUL, CSA, TUVUL, CSA, TUVUL, CSA, TUVRelays & SocketsModelAppearanceNo. of Poles2, 3, 42, 3, 42, 3, 42, 3, 4Wire Sizes0000 AWG400 mcm0000 AWG400 mcm600V / 200A600V / 350A600V / 200A600V / 350AM10 studM12 studM10 studM12 studVoltage/CurrentTerminalsSizeType19mm hex17mm hex19mm hex35mm DIN railSurfaceSurface(N-m)21 - 2838 - 4921 - 28TerminalTorque38 - 49DIN Rail Stop(in-lbs.)186 - 249337 - 435186 - 249337 - 435BNL-8BNL-8——Dust CoverIncludedIncludedIncludedIncludedMarking m hex35mm DIN railMountingTimersWidthApprovalsTerminal Blocks1. BNDN1000 aluminum DIN rails are available in 1 meter lengths.Circuit BreakersCanada: 888-317-4332 USA: 800-262-4332905

Terminal BlocksDimensionsPart No.DiagramI (betweenterminal screws: 46)1.5Switches & Pilot LightsBN Power BlocksBN200NWBN400NWADust CoverBECDG HRelays & SocketsSignaling LightsFPart No.BN200NWBN400NWNo. of polesDim ADim BDim CDim DDim EDim FDim GDim HDim 6”(4mm)Terminalstud mm)0.156”(4mm)Terminalstud mm)0.156”(4mm)Terminalstud mm)0.195”(5mm)Terminalstud 2mm)0.195”(5mm)Terminalstud 2mm)0.195”(5mm)Terminalstud �(120mm)Part No.DiagramMounting Hole Dimension90 (betweenterminal screws: 46)ABN200NW#KBN400NW#KHI4-M6 ScrewJ30TimersDust CoverEFK LDGBCBN200NW#KBN400NW#KNo. of polesDim ADim BDim CDim (272mm)9.98”(256mm)Dim EDim FDim GDim HDim IDim JDim KDim LTerminalstud M10Ø0.312”(8mm)3 ��(4mm)2.59”(66.5mm)2.54”(65mm)Terminalstud M10Ø0.312”(8mm)3 ��(5mm)3.21”(81.5mm)3.12”(80mm)Circuit BreakersTerminal BlocksContactorsPart No.906www.IDEC.com

Terminal BlocksBA SeriesSwitches & Pilot LightsBA SeriesKey features: Self-contained: end plates are not requiredRugged heavy-duty constructionCurrent capacities up to 40A3-pole units available as 1 piece (no endplates are needed)Fuse blocks with blown fuse indicatorsSignaling LightsUL RecognizedFile No. E78117CSA CertifiedFile No. LR64803SpecificationsRelays & SocketsPower BlocksModelBA111TBA211TBA311TBA411S0.984” (25mm)1.201” (30.5mm)1.358” (34.5mm)0.630” (16mm)UL, CSAUL, CSAUL, CSAUL, CSA333116 to 6 AWGAppearanceApprovalsNo. of PolesWire SizesVoltage/Current22 to 12 AWG18 to 10 AWG300V / 15A300V / 20A150V / 30A600V / 40AJIS600V / 16A600V / 21A600V / 40A600V / 70ASizeM3M3.5M4M5TypeStandard screwStandard screwStandard screwStandard screwMountingTerminalTorque35mm DIN rail35mm DIN rail35mm DIN rail35mm DIN rail(N-m)0.6 - 1.01.0 - 1.31.4 - 2.02.6 - 3.7(in-lbs.)5.3 - 8.98.9 - 11.512.4 - 17.823.1 - 32.8BNL-5BNL-5BNL-5BNL-5BNC320DIN Rail StopDust 9BNM9BNM9End clipBNM3BNM3BNM3BNM3Terminal BlocksMarkingStripBNC220PVCContactorsTerminals22 to 14 AWGUL/CSATimersWidth1. BNDN1000 aluminum DIN rails are available in 1 meter lengths.2. Marking strips are available in 1 meter lengths.Circuit BreakersCanada: 888-317-4332 USA: 800-262-4332907

Terminal BlocksSwitches & Pilot LightsBA SeriesSpecifications, continuedFuse BlocksModelBAF111SUBAF111SNUBAF111SDU0.630” (16mm)0.630” (16mm)0.630” (16mm)NoneNeon (100 to 300V AC)LED (24V DC)UL, CSAUL, CSAUL, CSA111Signaling LightsAppearanceWidthBlown Fuse IndicatorApprovalsRelays & SocketsNo. of PolesWire Sizes18 to 10 AWG18 to 10 AWG18 to 10 AWGCurrent10A maximum10A maximum10A maximumSizeM4M4M4TypeStandard screwStandard screwStandard screw35mm DIN rail35mm DIN rail35mm DIN railTerminalsMountingTerminalTorque(N-m)1.4 - 2.01.4 - 2.01.4 - 2.0(in-lbs.)12.4 - 17.812.4 - 17.812.4 - 17.8BNL-5BNL-5BNL-5———DIN Rail StopDust CoverApplicable Fuse SizeBNM7BNM7BNM71/4” x 1-1/4”(6.35 x 31.8mm)1/4” x 1-1/4”(6.35 x 31.8mm)1/4” x 1-1/4”(6.35 x 31.8mm)Circuit BreakersTerminal BlocksContactorsTimersMarking Strip908www.IDEC.com

Terminal BlocksBA SeriesPart No.Diagrams7.9 7.96.7Dust Cover238.520.0Dust Coverø3.6 min.8.4 max.20.04 min.50Dust CoverRelays & Sockets135 max.216ø4.2 min.When usingBAA/BAP: 37.52-M5 Screw3.3 min.38.58.529.8When usingBAA/BAP: 326-M3.5 Screw30.59.85 max.Signaling LightsBA211Tø3.2 min.6.6 max.When usingBAA/BAP: 326-M3 Screw25BA111TSwitches & Pilot LightsDimensions22.8BA311T9.4 max.6 max.4.5 min.4821350Dust Coverø5.2 min.22.8BA411STimersWhen usingBAA/BAP: 37.52-M5 Screw1612.8 max.6.5 max.4.5 min.486336ø4.2 min.When usingBAA/BAP: 4922.51610ContactorsBAF111Diagrams2-M4 ScrewPart No.10 max.5.2 max.4.5 min.Terminal BlocksCircuit BreakersCanada: 888-317-4332 USA: 800-262-4332909

Terminal BlocksSwitches & Pilot LightsAccessoriesAccessoriesPart Numbers: End Plates, DIN Rail Stops, Stand-Offs, DIN Rail and Dust CoversItemAppearanceUse withPart gnaling LightsBNF10SWEnd 150WBNE150WBNDH15WBNDE15WBNH10WRelays & 5(small)1. DIN rail stops prevent side-to-side movement.2. The BNL-5 width is 0.375” (9mm).BN75WBN150WBNL6(medium)1. DIN rail stops prevent side-to-side movement.2. The BNL-6 width is 0.375” (9mm).3. To firmly stabilize these higher profile terminal blocks,the BNL-6 has a higher profile than the BNL-5.BNDH15WBN200NW#BN400NW#BNL8(large)1. DIN rail stops prevent side-to-side movement.2. The BNL-8 width is 0.571” (14.5mm).3. # number of poles.BNS31.46” (37mm) heightBNS43.03” (77mm) heightBNF10DWBA111TTimersBA211TDINRail StopsBA311TBA411SBAF111SUCircuit BreakersTerminal BlocksContactorsBAF111SDUDIN RailStand-OffsAll seriesDIN RailAll seriesBNDN1000(length 39.37”(1mm)1. For calculating the rail lengths required, see the instructions on page 876.2. The DIN rail material is aluminum.Surface MountBracketBNDH15W(dual-deck)BNDL2Used to surface mount dual-deck terminal blocks. (BNDL2).910www.IDEC.com

Terminal BlocksAccessoriesSwitches & Pilot LightsAccessories, continuedPart Numbers: Rods, Nuts, Marking Strips, Dust Covers, and JumpersItemAppearanceUse withPart No.RemarksBNDH15WBNH10WBNH15MWBNC230BNH15LWMarking 00BNC1000The overall length is 39.37” (1,000mm).The material is polycarbonate (UL94-V2).BNM7Material: polyvinyl chloride (PVC)Strip dimensions are 0.37”x39” (9.5 x 1,000mm).BNM9Material: fiberglassStrip dimensions are 0.37”x39” (9.5 x 1,000mm).BNM3Used to prevent marking strips from sliding off terminalblock.All seriesAll 6FWBNH15LWBNJ46FBNH30WBNJ56FBNDH15WBNJ26FWJumpers come standard with 6 points (except BNJ62).Note: insulated jumpers available - add “B” to end of partnumber. For example, BNJ26WB.ContactorsFork TerminalJumpersBNC320TimersRing TerminalJumpersBNH50WRelays & SocketsMarking StripsBNH30WSignaling LightsDustCoversBNR1(265mm)M4 Thread RodBNDH15WConnecting NutsBNR1BNR2Terminal BlockRemoval ToolBNN1Terminal BlocksBNR2(500mm)1. Rod and connecting nuts are used to mount dual-deckscollectively.2. Each connecting nut set includes 1 hex connecting nutand 1 round connecting nut.3. The BNR1 rod dimensions are 0.027 “x 10.43” (0.7 x265mm).4. The BNR2 rod dimen-sions are 0.027” x 19.69” (0.7 x500mm).Circuit BreakersBND2For accessory dimensions, see page 912.Canada: 888-317-4332 USA: 800-262-4332911

Terminal BlocksDimensionsDimensions: DIN RailPart No.DiagramsBNDN1000Dimensions: JumpersBNH ircuit BreakersTerminal BlocksThickness 0.8mm .8Insulation4.29.31260 0.840 (6-pole)3.7BNJ56W (fork)60 (6-pole)ø41.48R1 6.4.85InsulationBNJ5652.5 (6-pole)2.810.54.21.40.8112Insulation48.2R2.111 6FW (fork)40 (6-pole)4.535 (6-pole)BNJ46F (fork)52.5 (6-pole)118.2R1 3.7.8571111InsulationBNJ46BNJ46BNJ46F (fork)BNJ56BNJ56F (fork)5.79.575.7ø3.71.40.84BNJ16BNJ16F (fork)BNJ26WBNJ26FW (fork)35 (6-pole)9.5 5.8BNJ16F (fork)BNJ166Part No.5.5TimersRelays & SocketsSignaling LightsSwitches & Pilot LightsAccessoriesInsulation

Terminal BlocksAccessoriesSwitches & Pilot LightsDimensions, continuedDimensions, DIN Rail Stops and Stand-offsPart No.DimensionsBNL-645Signaling Lights9BNL-6 shown, BNL-5 same except without back crossbar46Relays & .5BNS354261525 M528152.6BNS4302625 Terminal Blocks12.5BNS4Circuit BreakersCanada: 888-317-4332 USA: 800-262-4332913

Terminal BlocksSignaling LightsSwitches & Pilot LightsAccessoriesDimensions, continuedDimensions: End PlatesPart No.DimensionsPart No.Dimensions3853BNE75WBNE15W5574Relays & NDE15WTerminal Blocks548Circuit BreakersBNE50W5914www.IDEC.com

Terminal BlocksInstructionsSwitches & Pilot LightsInstructionsWiring Touch-Down Terminal Blocks: BNH SeriesInstructionsStep 1Step 2Step 3Step 4Signaling LightsStep 1. Insert the wire (or crimping terminal) into theterminal block with the terminal screws in the openposition. (Use of crimping terminals is optional.)Step 2. Push the terminal screw down to hold the wire inplace.Step 3. Hold the terminal screw down, and tighten with ascrewdriver.Step 4. To remove the wire, loosen the terminal screw andpull up until wire is released.Installation and Removal of Terminal BlocksInstructionsAppearanceRelays & SocketsStep 1. Slide the terminal blocks onto the DIN rail from one end.Step 2. Use BNL5 or BNL6 end clips to secure the terminal blockrow and to prevent side-to-side movement. BNH10W,BNH15MW, BNH15LW, and BNH30W can be installedfrom the middle of a DIN rail.Step 3. To install, place the terminal block on top of the DIN railand push down until both edges of the terminal blocksnap onto the DIN rail.Step 4. To remove the terminal block, use the BND2 removal toolas shown on the right.TimersRemoval ToolBND2Mounting Double-Deck Terminal BlocksInstructionsAppearanceEnd PlateConnectingNut (hex)ConnectingNut (round)Terminal BlocksPanel Mount:Step 1. Assemble a row of terminal blocks with end plates onexposed end(s).Step 2. Use BNDL2 mounting clips at both ends of a row.Step 3. With the two holes of the mounting clip aligned withthe terminal block holes, insert a connecting rod througheach hole.Step 4. Secure the ends of the connecting rods with the connecting nuts, as shown below.Terminal BlockContactorsDIN Rail Mount:Step 1. First install the end plate. Then mount the terminal blocksonto the DIN rail.Step 2. To prevent side-to-side movement on the DIN rail, use theBNL-8 mounting clip at both ends of the rail.Mounting ClipConnecting RodMounting ClipCircuit Breakers800-262-IDEC (4332) USA & Canada915

Terminal BlocksSignaling LightsSwitches & Pilot LightsInstructionsCalculating DIN Rail T20BNF10SBN75WBN50W (BNH50W)BNE20BN40W (BNH40W)Step 1. Add widths of all terminal blocks(reference pages 864 through869).Step 2. Add the endplate thickness (usually only one).Step 3. Add the DIN rail stop widths(usually two are used).Step 4. Round to the nearest 2” (50mm)increment to allow for DIN railhole spacing.Step 5. Add 1” (25mm) to ensure 0.5”(12.5mm) of clearance at eachend of the DIN rail.BN400BW2 (BN400NW2)BN300BW2 (BN300NW2)BN30W (BNH30W)BN15LWT (BNH15LWT)BN15LW (BNH15LW)BN200BW2 (BN200NW2)BN15MWT (BNH15MWT)BN15MW (BNH15MW)BN10W (BNH10W)12.5138.5126.769.67 8121415.517232313132026265 1515Relays & SocketsTimers92 (2P)136 (3P)180 (4P)52119 (2P)176 (3P)233 (4P)L 2 (Mounting Centers)DIN Rail Stop DimensionsPart No.WidthBNL-5.374” (9mm)BNL-6.374” (9mm)BNL-8.571” (14.5mm)Torque Specifications and Applicable Connector SizesScrew SizeM3M3.5M4M5M6M8M10M12(N-m)0.6 to 1.01.0 to 1.31.4 to 2.02.6 to 3.73.9 to 5.410 to 13.521 to 2838 to 49(kgf-cm)6.1 to 10.210.2 to 13.314.3 to 20.426.5 to 37.739.8 to 55.1102 to 138214 to 286388 to 500Dimension ��(32.8mm)1.981”(50.8mm)Dimension .546”(14mm)Dimension 014”(26mm)Dimension DØ 0.125”(3.2mm)Ø 0.140”(3.6mm)Ø 0.164”(4.2mm)Ø 0.203”(5.2mm)Ø 0.242”(6.2mm)Ø 0.332”(8.5mm)Ø 0.410”(10.5mm)Ø 0.488”(12.5mm)Rated CurrentApplicable WireTerminal Blocks40L 1 (Rail Length)TorqueRated at 60 CApplicable WireRated at 60 C22 AWG (0.3mm )3A6 (14mm )50A20 AWG (0.5mm2)5A4 (22mm2)75A2218 AWG (0.75mm )7A0 (38mm )100A16 AWG (1.25mm2)10A00 (60mm2)150A14 AWG (2mm2)15A0000 (100mm2)12 (3.5mm )20A300mcm (150mm )300A10 (5.5mm2)30A400mcm (200mm2)350A22Circuit Breakers78 (2P)115 (3P)152 (4P)310.5Contactors332200A2UL/CSA ratings are specified. The current carrying capacity depends on the rating of the wire used, as shown.916www.IDEC.comDiagram

Terminal BlocksBX SeriesSwitches & Pilot LightsBX SeriesKey features:Signaling Lights Unique touch-down terminals All units are molded from UL94-V0 material withexcellent flame- and shock-resistance Mount on DIN rail or flat surface Current capacity: 1A Available with 16, 20, 26, 34, 40, and 50 pins UL and CSA Hinged covers with built-in marking stripsSpecifications7.62mm (M3 screw)Rated Voltage125VRated Current1ARated Wire Size22-14 AWG (2mm2)Insulation Resistance100MΩ minimum (500V DC)Dielectric Strength500V AC, 1 minuteOperating Temperature–10 to 65 CHumidity Range45 to 85% RHHousing MaterialPPE resin (UL94-V0)Terminals/ConnectorPBT resin (UL94-V0)Relays & SocketsTerminal WidthMicroSmart CPUTimersBX Series Application BX1D-TBX1D-SAAI/OBX1D-T26ABX1D-S26ATerminal BlocksMicroSmart -T32K3FC4A-T32S3BX9Z-H*RCircuit BreakersI/OBX1D-T26ABX1D-S26ABX9Z-H*R*See cable selection table next page.I/OBX1D-T20ABX1D-S20A800-262-IDEC (4332) USA & Canada917

Terminal BlocksSwitches & Pilot LightsBX SeriesPart NumbersPart Numbers: Break-Out Modules and CablesAccessoriesSignaling LightsPins1620Relays & SocketsStandard MILConnector Modules26344050TerminalStyleModule X1D-S50ACable Part NumberRemarksMIL to SingleConnectorsMIL to MIL ShieldedMIL to C9Z-H#B20FC4A/FC5A 16 & 32 pointI/O modulesFC9Z-H100C26AFC9Z-H#A26FC9Z-H#B26FC4A/FC5A 20 & 40 pointI/O slim imers1. For BX terminal arrangements, see page 879.2. # length codes:100 39.4”(1 meter)200 78.7”(2 meter)300 118.1”(3 meter)Part Numbers: DIN Rail and DIN Rail StopsUse withDiagramPart No.RemarksDIN RailAll BX seriesBNDN10001. The length is 39.37” (1,000mm).2. For calculating the rail lengths required,see the instructions on page 876.3. DIN rail material is aluminum.DIN Rail StopAll BX seriesBNL61. Rail stops prevent side-to-side movement.2. Use rail stops on BNDN1000 DIN rails.Circuit BreakersTerminal BlocksContactorsDescription918www.IDEC.com

Terminal BlocksBX Series216-Pin47135Typical for all Pins7 9 11 13 15467135Typical for all Pins7 9 11 13 15 17 19413125Typical for all Pins7 9 11 13 15 17 19 21 23 258 10 12 14 16 18 20468 10 12 14 16 18 20 22 24 26 28 30 32 34135Typical for all Pins7 9 11 13 15 17 19 21 23 25 27 29 31 333254765Typical for all Pins7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 397668 10 12 14 16 18 20 22 24 262134-pin68 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4044349 11 13 15 17 19 21 23 259 11 13 15 17 19 21 23 25 27 29 31 338 10 12 14 16 18 20 22 24 26 28 30 32 349 11 13 15 17 19 21 23 25 27 29 31 33 35 37 398 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 408 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 501357135Typical for all Pins7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49469 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49Contactors2Timers216537Relays & Sockets269 11 13 15 17 198 10 12 14 16 18 20 22 24 26528 10 12 14 16 18 205638 10 12 14 163426-Pin41Signaling Lights469 11 13 151250-Pin25240-Pin8 10 12 14 163220-Pin61Switches & Pilot LightsTerminal Arrangements: BX Series8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50Terminal BlocksCircuit Breakers800-262-IDEC (4332) USA & Canada919

Terminal BlocksDimensions: BX 7.62BX1D-S50A43.1BX1D-T50ACircuit BreakersTerminal BlocksContactorsTimersRelays & 0www.IDEC.comMaximum height is 64.3mmwhen cover is open.BX1D-S20AAø4.Signaling LightsBX1D-T20AL50BX1D-T16ABX1D-S16APins2.5Part No.14.2Switches & Pilot LightsBX Series

Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers Specifications, continued Model BNH50W BN75W BN150W BNDH15W Appearance Width 0.610” (15.5mm) 0.787” (20mm) 1.024” (26mm) 0.315” (8mm) Approvals UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV No. of Poles 1 1 1 2

Related Documents:

signaling in ISDN has two distinct components: signaling between the user and the network (access signaling), and signaling within the network (network signaling). The cur- rent set of protocol standards for access signaling is known as the Digital Subscriber Signaling System No. 1 (DSS1).

UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600 P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illumi-nated .

Chapter 15 BME42-620 Lecture 21, November 29, 2011 1. . gene expression regulation are usually slow. Alberts MBoC 5e 13. General Principles of Signaling (IV) Cascade of signaling events Receptors . 18. Overview of Cell Signaling Cascade of signaling events Receptors

Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks Circuit Breakers Switches & Pilot Devices AL6 Illuminated Pushbuttons (Sub-Assembled) Operator LED Lamp Lens Completed Unit Operators Style Contact Operator Part Number Round Square Rectangular AL6 Illuminated Pushbuttons SPDT Momentary AL6M-M100 AL6Q-M100 AL6H .

Product Guide 2018. . 1700V IGBT Modules Bi-directional Switches, Choppers, Dual Switches, Half Bridges and Single Switches 04 3300V IGBT Modules Choppers, Dual Switches, Half Bridges and Single Switches 05 4500V IGBT Modules Choppers, Single Switches 06 6500V IGBT Modules Choppers, Single switches 06 IGBT Press-pack 06 Custom IGBT Modules 07

Stress Signaling II: Calcium Sensing and Signaling Marie Boudsocq and Jen Sheen* Department of Molecular Biology, Massachusetts General Hospital & Department of Genetics, Harvard Medical School, Boston, MA 02114, USA Summary Calcium is an essential second

Signaling in practice Credible Signaling in some Markets with Congestion Job market for new Ph.D. economists each candidate can send signals to up to two departments signals are private Informal preference signaling the entry-level market for clinical psychologists, Roth and Xing (1994) Intern

phases attained more algae for future oil extraction (Day 32 was in growing phase). After ultrasonication, the lipids were extracted by the Folchs method. The lipid content was 8.6% by weight. 0 0.05 0.1 0.15 0.2 0.25 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Algae Mass (grams) Time (days) Haematococcus Growth in Bolds Basal .