Nexus 1450 Cyber Secure Energy Panel Meter with Advanced Power Quality & Multiport CommunicationP40N RemoteMultifunctionLED DisplayNexus 1450 MeterNewMetering and CommunicationAdvanced Power Quality Analysis Multilevel Cyber Secure Encrypted Configuration Class A IEC 61000-4-30 Edition 3 PowerQuality Measurements Advanced Web Server with Waveform Analysis Tools Up to 1024 Samples per Cycle-based Measurements;Extended Frequency Rangewww.electroind.comP70N ColorTouchscreen LCD Display IEC 61000-4-15 Flicker Measurements IEC 61000-4-7 Harmonic Measurements 0.06% Energy Accuracy Over Wide DynamicMeasurement Range; Meets ANSI C12.20 0.1Accuracy Class EN 50160 Power Quality Reports Highly Accurate and Stable Measurements UsingMulti-Gain Sensing New CORE Logging Architecture 6 Available Communication Ports, IncludingModbus and DNP3 Protocols and RTU Master Direct Physical Retrofit to Nexus 125X Series Meter/Transducer with Greater Functionality Two Independent Ethernet Ports, with Unique IPAddressing, Port Control for Security and EncryptedEmail on Alarm Separate 3 Line LED Displays and New ColorTouchscreen LCD DisplayNew Supports Wideband Frequency 20-500 HzElectro Industries/GaugeTech The Leader in Power Monitoring and Smart Grid Solutions Manual Waveform Capture Easy Installation of Transducer and Separate Display

IntroductionElectro Industries’ Nexus 1450 meter is a powerful energy meter thatprovides accurate electrical energy measurements and offers advancedcapabilities for power quality analysis and determining electrical powerreliability. The meter is a transducer base with a separate display. Thetransducer base retrofits to existing Electro Industries’ Nexus 1250 and1252 meters. The Nexus 1450 meter is ideal for existing switchboardpanels, since it can be installed without cutting panel doors. The separatedisplay mounts into existing analog meter knockouts.The Nexus 1450 meter is protected with a multi-level Cyber Securedencrypted configuration with 10 highly secure encrypted user IDs andpasswords that help prevent tampering and hacking of your power systemdata. The meter's built in WebView Energy Dashboard allows you toanalyze metering data without needing software. You can navigate easilythrough multiple webpage views and get detailed information on energyusage and power quality: view real time data, analyze stored history logs,view alarms and waveform records.Multi-Gain Sensing ProvidesSuperior AccuracyThe Nexus 1450 meter utilizes EIG’s latest measurement-sensingtechnology - Multi-Gain . Multi-Gain technology uses twosensors on the current inputs - a high gain sensor and a lower gainsensor. Each sensor simultaneously measures the current signal comingfrom the external current transformers. The meter’s intelligent processinglooks at the signal level and determines the optimal sensing circuit for thehighest accuracy measurement. With this technique, the meter has 0.06%Energy accuracy throughout an extended measurement range, which is adefining trait of Nexus Series meters.The meter’s standard pickup range starts as low as 1 mA, and highaccuracy is attained at 25 mA. Multi-Gain metrology allows the samemeter to be used on both 5 A secondary and 1 A secondary CTs. Themeter should maintain high accuracy measurement throughout itsinstalled life. Refer to the accuracy chart on the next page, for details.With 6 simultaneously operating communication ports, the meter is acommunication hub to multiple software systems. The Nexus 1450meter has 4 serial ports that speak Modbus and DNP3 protocols. It alsohas two independent Ethernet ports, consisting of a 10/100BaseT copperRJ45 connector and an ST Terminated 100Base FX Fiber Optic Ethernetport. Each Ethernet port has a unique IP address. Through the meter's 6ports, a user is able to communicate to multiple computer-basedsystems, providing data to entities throughout an enterprise. The serialcommunications ports offer RTU Master capability, and the Ethernet portssupport encrypted email on alarm.The meter also excels at measuring power quality, including waveformrecording; manual waveform capture; and IEC 61000-4-7, IEC 610004-15, and IEC 61000-4-30 Class A Edition 3 compliance. The Nexus 1450 meter lets you look at the reliability of the electrical power circuit todetermine causes of faults, voltage surges and sags, and harmonics.Multi-Gain Metrology allows the Nexus 1450 meter to havehighly repeatable and stable measurements throughout range2Typical accuracy charts

Meter Accuracy SpecificationMeasurementMeasurementVoltage L-NVoltage L-NVoltage L-LVoltage L-LCurrentCurrentNeutral CurrentNeutral -hour**VARVARVARhVARhVAVAPower FactorPower FactorTHDTHD0.04% of reading0.04% of reading0.04% of reading0.04% of reading0.04% of reading0.04% of reading0.1%0.1%0.004 Hz0.001 Hz0.06% of reading0.06% of reading0.06% of reading0.06% of reading0.15% of reading0.15% of reading0.15% of reading0.15% of reading0.06% of reading0.06% of reading0.15% of reading0.15% of reading2.5% of reading2.5% of readingAdvanced Energy Meter forPrimary LoadsThe Nexus 1450 unit is an electrical energy meter designed to be usedfor any important application. In addition to highly accurate energymeasurement, the meter features: Full 4 quadrant metering. Max/Min recording with timestamp. Extensive logging with 8 logs of programmablehistorical profiles. Built-in CORE log for web trending. Transformer and Line Loss compensation: for both iron andcopper, and total substation losses.* For 50/60 Hz measurement;**(0.025 A to 20 A at PF 1); The Nexus 1450 meter also supports wideband accuracy for 20 to 500 Hz applications; full accuracy specifications are given in the Nexus 1450 MeterInstallation and Operation Manual. CT and PT compensation: to correct instrumenttransformer errors. Coincidental readings: e.g., PF or VARs at time of Peak Demand.Precision Crystal Time Reference: Load aggregation/universal metering: pulse inputs can be usedto aggregate or accumulate different loads. Utility commoditiessuch as gas and water can also be accumulated.The Nexus 1450 meter is equipped with an internal clock crystalaccurate to 3.5 PPM over the full operating temperature range and 5 PPMat over ten years of use. This highly accurate trimmed clock designallows users to maintain accurate time when running on crystalsynchronization. The meter's clock crystal will drift less than 6 secondsper month from (0-40) C.Additional time sync methods include: Line frequency sync. IRIG-B time sync. DNP3 time sync. SNTP time sync.On-board Time of Use Measurements:The Nexus 1450 meter uses a perpetual Time of Use (TOU) calendarthat only needs to be set up once. The TOU implementation allows theuser to set up multiple tariffs to meet any contractual obligations. It alsoallows the user to customize any energy parameter for TOU. The 16available TOU registers can be configured not only for TOU built-in energyreadings, but also for any stored data from pulses or other readings thatneed TOU functionality. Up to four seasons - seasons can be customized. Flexible billing periods/rates/holidays/schedules setup. Cumulative and continuous cumulative demand are available.Easily Configure Almost any Time of Use Usage Profile3

Data Logging and Internal StorageThe Nexus 1450 meter provides advanced capabilities for storingmeasured values over time, for trending and analysis. The meter has upto 4 GB of memory, with up to 1.2 GB allocated exclusively to loggingand user storage, and is preconfigured to store its core measurements (inthe CORE log) every 15 minutes, without any user intervention. Coremeasurements include 142 different values. Additionally, a user is able toconfigure up to 8 historical logs. All logs work with a FIFO buffer and rollover when filled. The following logs are available: Trending Log: The meter supports up to eight historical,trending logs of 64 data channels per log, acting as a traditionalload profile recorder with up to 8 separate logs. System Events Security Log: This anti-tampering logrecords all events in the meter, with an associated timestamp.The unit records: Resets.Programming changes.Password access changes.Time changes.Power up/down.Change of Firmware.Chart of Memory for LoggingLogV1 - Maximum# of RecordsDaysV2 - Maximum# of RecordsDaysSystem Events16384CORE Log*1638416332768327Log 1**1638416332768327Log 2**1638416332768327Log 3**1638416332768327Log 4**1638416332768327Log 5**1638416332768327Log 6**1638416332768327Log 7**1638416332768327Log 8**1638416332768327Digital Input1638432768Limits/Alarms1638432768Power Quality1638432768Waveforms***For 512 samples per cycle, 1second waveform recording at 60Hz: 682 records.For 1024 samples per cycle, 1second waveform recording at 60Hz: 341 records.32768* The CORE log automatically records readings for 142 parameters at the logging interval.The default interval is 15 minutes. Days are based on approximately 100 records per day.** Logs 1 - 8 are user-assignable and allow 64 parameters per log. Days are based onapproximately 100 records per day.*** The number of waveform records depends on the sampling rate and the length of waveform recording. V1 offers up to 512 samples per cycle recording and V2 offers up to 1024samples per cycle recording.4 Input Status Change Log: This log suppliesinformation on the state of the meter’s internal digital inputs. Limit Log: The Limit/Alarm log can be set to record on highand low conditions for up to 32 user programmable limits. Power Quality Log: This log captures power qualityevents, such as surges and sags, and lets you view and analyzethe data through power quality graphs, such as the ITI CBEMACurve and SEMI F47 standards.

Power Quality MeasurementsCritical sensitive equipment and over utilized distribution systems need tobe monitored for proactive system reliability improvements. By measuringpower quality indices such as voltage anomalies, harmonics, flicker,imbalances and many other conditions, you are able to quantify yoursystem reliability. Recording waveform events on sags and swells,including peak and duration of the event, with microsecond resolution,will facilitate forensic engineering analysis of harmful events in yourpower system. The Nexus 1450 meter is designed to the higheststandards for power quality, including IEC 61000-4-7, IEC 61000-4-15and IEC 61000-4-30 Class A Edition 3. It calculates weekly pass/failreports using the EN 50160 standard.IEC 61000-4-30 Class A Reporting:IEC 61000-4-7 Harmonics: View harmonic magnitudes to the 511th order for each voltageand current channel, using EIG's Log Viewer software. Harmonic magnitudes and phase angles in real time are resolvedto the 127th order. Obtain THD, TDD, and K-Factor. Conduct power quality analysis at the high end of the harmonicmagnitude spectrum.Limits/Alarms: Supporting the most stringent international power qualitystandards, the Nexus 1450 meter offers full reporting of powerquality conditions using the IEC 61000-4-30 Class Amethodology Edition 3. Operates on both 230 volt/50 Hz and 120 volt/60 Hz.IEC 61000-4-15 Flicker Measurement: The Nexus 1450 meter measures Flicker in compliance withthe IEC 61000-4-15 Class A standard. Operates on both 230 volt/50 Hz and 120 volt/60 Hz.The Nexus 1450 meter lets you set multiple programmable limits forany measured value and for conditions set up in a Boolean logic tree. Thisfeature will record events based on threshold settings. Limits can be usedwith timers and logic to trigger control events. The Ethernet ports can beprogrammed to send emails on alarm.EN 50160 Report:The meter calculates weekly EN 50160 power quality reports. The reportsare available on the web server and can be easily accessed to determinepower system reliability.Power Quality Waveform Captures and Reporting5

Waveform Recording:The Nexus 1450 meter offers waveform recording at a sampling rate ofup to 1024 samples/cycle. The meter can be programmed to recordwaveforms on multiple power quality events, such as surges and/or sags(manual waveform capture through software is also supported). 16-bitA/D conversion provides precise waveform resolution. Both voltage andcurrent recording offer pre and post-event analysis. Fault recording offers8 times full-scale capture capability. Both hardware and software triggersare available. The meter also supports manual waveform capture.The waveforms can be viewed either through CommunicatorPQA software or on the meter's built-in web browser, or they can bedownloaded to third party software for analysis. By analyzing thewaveforms, the nature and source of power quality anomalies can bedetermined, and steps can be taken to remedy the situation. Waveformrecording for wideband frequencies is also supported.Cyber Secured ConfigurationProtects Meter from Tampering: Highly Secure Encrypted Passwords - 128 Bit AES Encryption. 10 Customizable Users, with Passwords up to 30 Characters. Password Fail Timeouts Virtually Eliminate Brute Force Hacking. 4 Roles with Customized User Permissions. Physical Seals and Lock-outs to Prevent Remote Hacking orTampering. Signed Firmware Helps Prevent Tampering with Meter Operation.V-Switch Key technologyThe Nexus 1450 meter is equipped with V-Switch key upgradetechnology that lets you upgrade meter functionality even afterinstallation. This means you can purchase what you need now and thenupgrade whenever you need the additional features. Following are theavailable V-Switch keys:Nexus 1450 FeaturesV1 (Basic)V2 (Advanced)Voltage, Current, etc.PPTHD and HarmonicsPPTime of UsePPWaveform RecordingPPSampling Rate5121024Basic MeasurementsPower Quality MeasurementsView High-Resolution Waveform EventsPhasor Analysis:Communicator PQA software lets you view the phase angles andsymmetrical components for voltage and current, helping you analyzeelectrical system problems.FlickerPPIEC 61000-4-30 Class ASAEN 50160 ReportingPPCORE LogPPCustom Historical LogsPPPQ LogPPWaveform LogPPLimit LogPPDigital Input LogPPMemory for logging512 MB*1200 MB*SerialPPModbus over SerialPPDNP3 over SerialPPRJ45 EthernetPPFiber EthernetPPModbus over EthernetPPDNP3 over EthernetPPStorageCommunicationAnalyze Power System Phasors6* The unit has 4000 MB flash memory installed, for longer reliable life.Some of the memory is allocated to wear-leveling and system use.

Advanced CommunicationStandard I/OThe Nexus 1450 meter is equipped with extensive communicationcapabilities that allow it to speak with many different SCADA or othercommunication systems, simultaneously. The meter has 6communication ports as a standard offering. These ports include 4 serialports and 2 Ethernet-based communication ports. The Ethernet portsinclude an ST terminated fiber optic port and an RJ45 port. Both ports useseparate IP addresses, so that they can run on simultaneous redundantnetworks. The Ethernet ports offer encrypted email on alarm and portcontrol for security.8 Built-in Digital Status Inputs: Inputs automatically sense whether the circuit isexternally wetted. If externally wetted, input up to 150 V DC is accepted. If internally wetted, the meter supplies the necessary voltage forthe control application. Inputs can be used as pulse accumulators for counting pulsesfrom other meters.Details of Ports:VAUX Input: 6 standard Com ports. 4 serial ports - RS485 (one of the ports is RS485/RS232selectable); RTU Master capability. 2 independent Ethernet ports - RJ45 and Fiber Optic, withseparate IP addresses, advanced port control, and encyrptedemail on alarm. Modbus RTU, Modbus ASCII, Modbus TCP/IP, DNP3 Level 2communication. All ports can be communicating simultaneously. Ports 3 and 4 can be used as Master ports to control up to 4 I/Omodules each, acting as an RTU master to slave bus devices. Encrypted email on alarm: email on exceeded limit, waveformrecording, status change, password tampering, and many otherconditions.RS485 Ports Neutral to ground or aux voltage readings for synchronizingschemes, for example, obtaining the frequency, magnitude, andphase angle on both sides of a switch or between generator andbus voltage.Two Standard Pulse Outputs: Solid State, form A, 35ohm max on resistance. 120 mA continuous, 350mA max for 10 ms. Peak voltage: 350 V DC.Two PulseOutputsIRIG-BRS232/RS485 Port Switching rate max: 10/s. Support pulse-countingapplications.Eight DigitalInputsRJ45 Ethernet PortTest Pulses*RuggedMetal CaseHeartbeatLEDFiber-OpticEthernetPortUniversal AC/DCPower SupplyRevenue SealFour Current Inputs* Two standard test pulses for Wh and VARh testing.Four Voltage InputsThe Nexus 1450 meter is a direct physicalretrofit to Nexus 1250 and 1252 meters.7

Revenue SealDigital Dry Contact Relay Outputs:The Nexus 1450 meter has a lockable cover for voltage and currentinputs, a Demand and programming Reset button seal, and two physicalmeter seal locations. Seals other than Demand/programming are orderedseparately.Optional I/O ModulesAnalog Outputs: 1mAON4/1mAON8: 4 or 8 AnalogOutputs, 0 1 mA, self-powered, scalable, bidirectional. 20mAON4/20mAON8: 4 or 8 Analog Outputs,4-20 mA, self-powered, scalable. Wiring: Common Mode. Accuracy: 0.1% of Full Scale. Calibration: Self-calibrating. Scaling: Programmable. Ordering: Up to 4 Analog Output modules.I/O ModulesAnalog Inputs: 8AI1: 8 Analog Inputs, 0 1 mA. 8AI2: 8 Analog Inputs, 4-20 mA. 8AI3: 8 Analog Inputs, 0 5 V DC. 8AI4: 8 Analog Inputs, 0 10 V DC. Wiring: Common Mode. Accuracy: 0.25% of Full Scale. Scaling: Programmable. Ordering: Up to 4 Analog Input modules. 4RO1: 4 Relay Outputs, 5 A, 250 V AC/30 V DC, Form-CLatching. Ordering: Up to 4 Digital Dry Contact Relay Outputs.Digital Solid State Pulse Outputs: 4PO1: 4 Solid State Pulse Outputs, Form A or C KYZ pulses. Maximum Pulse Speed: 20 pulses per second. Ordering: Up to 4 Digital Solid State Pulse Output modules.I/O Module Accessories: PSIO: Power supply for up to 4 additional I/O modules. Thisaccessory may be needed when using 3 or more displays and/ormodules. MBIO: Mounting bracket for external I/O modules. Must beordered with external I/O module (required).Optional Displays (displays connect to any RS485 port): P40N multifunction LED Master display supplies visual displayof meter readings; has a USB connection for direct data download of readings; and can also be used as a Master volt display.The P40N displays are ideal for analog ANSI meter retrofits. Optional Slave displays P41N (Ampere display) and P43N (Power display) can be daisy-chained. NEW! P70N color touchscreen display offers multiple preconfigured screens of meter readings and power quality data.It can be mounted in a panel or as a retrofit to an existing ANSImeter cutout using the SMKP70N mounting kit.Digital Inputs: 8DI1: 8 Digital Status Inputs Wet/Dry. Auto-Detect Up to 300 V DC.Case SealP40N RemoteMultifunction LED DisplayDemand/ProgrammingSealCase SealRevenue Seal Diagram8Meter Voltage &Current Cover(Standard)P70N ColorTouchscreen DisplayRS485 Communication (Multifunction or Separate Function Displays)Kwatt/KVARRS485 to I/O ModulesDirect retrofit your existingNexus 12xx series I/O anddisplay for an easy retrofitAmpsMultifunctionor Volts

WebView Energy DashboardBuilt-in Energy Dashboard Allows You to AnalyzeMetering Data Without Needing Software:The Nexus 1450 meter utilizes a unique HTML5-based web server. Thisnew web server acts as an Energy Dashboard, allowing the user to viewreal time data, as well as to analyze stored historical logs, alarms, andwaveform records. The WebView Energy Dashboard is built on aresponsive architecture, so that it will work properly on hand held browserbased devices, such as tablets and phones.Energy ScreenUsing the WebView Energy Dashboard, the user is able to navigateeasily through multiple webpage views, getting detailed information onenergy usage and power quality: Real time voltage and current readings and detailed cha

The meter also excels at measuring power quality, including waveform recording; manual waveform capture; and IEC 61000-4-7, IEC 61000-4-15, and IEC 61000-4-30 Class A Edition 3 compliance. The Nexus 1450 meter lets you look at the reliability of the electrical power circuit to determine causes of faults, voltage surges and sags, and harmonics.

Related Documents:

Nexus 5K with Integrated VSM ACI VTS UCS 5108 Blade Chassis Storage Database Relational UPS, RPS Nexus 2000 10GE Nexus 5k Nexus 4k Nexus 3k Nexus 2k Nexus 1KV VSM Nexus 1k Layer 3 Nexus 5k Switch Blade Server (color and subdued) Server DNS Server Secure Server Nexus 1010 Fibre Channel Fabric Switch Nexus 7k Telegram Channel

Cisco Nexus 3172TQ, Cisco Nexus 31108TC-V, Cisco Nexus 92348GC-X, Dell S4148T-ON Access or Leaf Switches Cisco Nexus 3132QX, Cisco Nexus 3164Q, Cisco Nexus 93180YC-EX, Cisco Nexus 93180YC-FX, Cisco Nexus 93240YC-FX2, Cisco Nexus N93360YC-FX2, Dell S5048F-ON, Dell S5248F-ON, ‡Dell S5296F-ON , Dell S5224F-ON ‡, Dell S4148F-ON Aggregation or Spine

Step 9 - Nexus Pro - CLM Edition (optional) 2 Chapter 2 Nexus Professional CLM Edition Con-figuration and Features 2.1Introduction Nexus comes in two forms, the popular Nexus Open Source , as well as industry-leading Nexus Profes-sional. In addition, users of Nexus Professional can add the Nexus CLM License to expand functionality

Cisco Nexus 1000V Cisco Nexus 1010 Cisco Nexus 4000 Cisco MDS 9100 Series Cisco Nexus 5000 Cisco Nexus 2000 Cisco Nexus 6000 Cisco MDS 9250i Multiservice Switch Cisco MDS 9700 Series Cisco Nexus 7000/7700 Cisco Nexus 3500 and 3000 CISCO NX-OS: From Hypervisor to Core CISCO DCNM: Single

THUANG/JPL IMDIS 2016, Gdansk, Poland Giovanni NEXUS: 3B42 NEXUS: 3B42RT Giovanni NEXUS: 3B42 NEXUS: 3B42RT Giovanni NEXUS: 3B42 RT Giovanni: over an hour NEXUS: a little over 2min 30X faster Giovanni: about 3min NEXUS: 1min 3X faster Giovanni: about 13min NEXUS: 2min 7X faster.

The Cisco Nexus 2000 Series Fabric Extenders behave like remote line cards for a parent Cisco Nexus 5000, Nexus 6000, or Nexus 7000 Series Switch. Working in conjunction with Cisco Nexus switches, the Cisco Nexus 2000 Series Fabric Extenders extend the capabilities and benefits offered by the parent Cisco Nexus switch while

Nexus Pro and Sonatype CLM Integra-tion 3.1Introduction Nexus comes in two forms, the popular Nexus Open Source , as well as industry-leading Nexus Profes-sional. In addition, users of Nexus Professional can add the Nexus CLM License to expand functionality to include use of Sonatype CLM as part of Nexus Professional staging capabilities.

1 Cisco Nexus 3524x, 24 10G Ports 2 2 SNTC-8X5XNBD Nexus 3524x, 24 10G 6 3 Nexus 3524 Layer 3 LAN Enterprise License 2 4 Nexus 3524 Factory Installed 24 port license 2 5 Nexus 3K/9K Fixed Accessory Kit 2 6 Nexus 2K/3K/9K Single Fan, port side exhaust airflow 8 7 Nexus