SunModo PV Rack Mounting System

2y ago
40 Views
2 Downloads
2.12 MB
29 Pages
Last View : 12d ago
Last Download : 3m ago
Upload by : Allyson Cromer
Transcription

EZ Pitched Roof SystemSunModo PV Rack Mounting SystemUL2703 CompliantPub. D10004-V016Copyright 2017

EZ Pitched Roof SystemPlease read carefully before installingProduct is tested to and recognized to UL 2703 standards for safety grounding andbonding equipment and meets UL 1703 fire standards.SunModo PV Rack Mount System can be used to mount photovoltaic (PV) panels in awide variety of locations. All installations shall be in accordance with NECrequirements in the USA. The self-bonding system is for use with PV modules thathave a maximum series fuse rating of 30A. Mechanical design loads per UL 2703:Downward Pressure: 33.42 psf (1600.2 Pa), Upward Pressure: 22.28 psf (1066.8 Pa),Down-Slope: 5 psf (239.4 Pa).TABLE OF CONTENTSInstaller Responsibility: . 4Safety:. 4Specifications: . 4Lag Pull-Out Capacities: . 5SunModo Self-Grounding System . 6EZ Roof Mount System Components . 7List of Compliant PV Modules . 12Tools Required for Installation . 15Torque Values for Pitched Roof System. 17Flashing Placement:. 18Sealant Application: . 18Installation Instructions: . 19EZ Roof Mount Kit K10068-XXX . 19EZ Roof Mounting Standoff Kit K10070-XXX . 20EZ Roof Mount with C-Bracket Kit K12005-001 . 20EZ Roof Mount Kit K10068-B20. 21EZ Metal Roof Mount Kit K20051-XXX . 22EZ Metal Roof Mounting Standoff Kit K10064-XXX . 23EZ Metal Roof Mount with C-Bracket A22001-001. 23Portrait Panel Configuration: . 24Minimum Panel Height . 25End Clamp Attachment . 25Mid Clamp Attachment . 25Landscape Panel Configuration: . 262 of 29

EZ Pitched Roof SystemMinimum Panel Height . 27End Clamp Attachment . 27Mid Clamp Attachment . 27Ground Wire Attachment . 28Ground Lug Installation . 28Rail End Covers . 28SunModo Corporation:Vancouver, Washingtonwww.SunModo.comPh: 360-844-0048info@sunmodo.comDocument Number D10004-V016 2017 – SunModo Corp.3 of 29File 02485001753

EZ Pitched Roof SystemInstaller Responsibility:Before ordering and installing materials, all system layout dimensions should be confirmed by field measurements.SunModo reserves the right to alter, without notice, any details, proposals or plans. Any inquiries that you may haveconcerning installation of the PV system should be directed to your SunModo Sales representative. ConsultSunModo Sales for any information not contained in this manual. This manual is intended to be used as a guidewhen installing SunModo’s EZ Roof Mount System on pitched roofs. It is the responsibility of the installer to ensurethe safe installation of this product as outline herein. Installer shall employ only SunModo products detail herein. The use of non SunModo components canvoid the warranty and cancel the letters of UL compliance.Installer shall guarantee that screws and anchors have adequate pullout strength and shear capacities.Installer shall adhere to the torque values specified in this Instruction Manual.Installer shall use anti-seize compound, such as Permatex anti-seize, lubricant is recommended for allthreaded parts.Installer is responsible to install EZ Pitched Roof System over a Fire Resistant roof covering rated for theapplication.Installer is responsible to determine that the roof, its rafters, connections, and other architectural supportcomponents can sustain the array under all code level loading conditions.Installer shall adhere to all relevant local or national building codes. This takes account of those thatsupplant this document’s requirements.Installer shall guarantee the safe placement of all electrical details of the PV array.Installer shall comply with all applicable local, state and national building codes, including periodic reinspection of the installation for loose components, loose fasteners and any corrosion, such that if found,the affected components are to be immediately replaced.Installer to ensure the structural support members or footings for mounting the array can withstand allcode loading conditions. Consult with licensed professional engineer for the appropriate loadingconditions.Installer to follow all regional safety requirements during installation.This racking system may be used to ground and/or mount a PV module complying with UL 1703 onlywhen the specific module has been evaluated for grounding and/or mounting in compliance with theincluded instructions.Safety:Review relevant OSHA and other safety standards before following these instructions. The installation of solar PVsystems is a dangerous procedure and should be supervised by trained and experienced personnel.It is not possible for SunModo to be aware of all the possible job site situations that could cause an unsafe conditionto exist. The installer of the roof system is responsible for reading these instructions and determining the safest wayto install the roof system. These instructions are provided only as a guide to show a knowledgeable, trained erectorthe correct part placement one to another. If following any of the installation steps would endanger a worker, theerector should stop work and decide upon a corrective action. Provide required safety railing, netting, or safety linesfor crew members working on the roof.Specifications:EZ Roof Mount K10068 is certified for International Building Code and International Residential Codes (IRC) byIAPMO. Evaluation Report is 0248, structural test per EC002-2011 and rain test per UL 441-96.4 of 29

EZ Pitched Roof SystemLag Pull-Out Capacities:Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 ALag pull-out (withdrawal) capacities (lbs.) in typical lumber:Douglas Fir, LarchDouglas Fir, SouthEngelmann Spruce, Lodgepole Pine (MSR 1650 f & higher)Hem, FirHem, Fir (North)Southern PineSpruce, Pine, FirSpruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL)SpecificGravity.50.46.46.43.46.55.42.505/16" Shaftper 1" thread depth2662352352122353072052665/16" Shaftper 2-1/2" thread depth665588588530588768513665Notes:1) Actual test data in Southern Pine: Test Load at 0.250 inch deflection: 1,800 lbs. uplift (withdrawal); 240 lbs.lateral. Test Load at 0.125 inch deflection: 695 lbs. uplift (withdrawal); 130 lbs. lateral.2) Thread must be embedded in a rafter or other structural roof member.3) See NDS Table 11.5.1 C for required edge distances.5 of 29

EZ Pitched Roof SystemSunModo Self-Grounding SystemSunModo developed a proprietary grounding and bonding system that is built into the mounting hardware forthe rails, clamps and splices. We provide further grounding through all of the SunBeam racking componentsincluding the Pipe Caps, Beams, Posts and Post Base Plates. All hardware meet UL 2703 Grounding andFire Standards tested by ETL.The basis of the system is our patented stainless steel floating grounding pin which is designed to be captivein the mounting components and provides a bonding path from the PV panel frames to the rails and railsplices, and finally to the ground lug. The self-grounding and bonding system is for use with PV modulesthat have a maximum series fuse rating of 30A. The maximum number of PV modules is limited by thesystem voltage, so in a system has multiple inverters, the SunModo racking system can theoretically go onforever.Finally we have added a spring and Blue 242 Loctite to our Mid Clamp assemblies. The sprig keeps the MidClamp in the open position ready to receive the solar module. The Blue Loctite is a light bonding agentallowing the T-Bolt engagement into the Rail when the Collar Nut is turned from above. The Blue Loctitehas the added benefit of being an anti-seize agent for stainless steel hardware in the area where it isapplied. For additional anti-seize protection refer to the ‘Tools Required for Installation’ section of thisdocument.Mid Clamp with Ground PinsSimilarly, the rail splices the grounding pins, eliminating the need for extra bonding components.Rail Splices with Grounding Pins6 of 29

EZ Pitched Roof SystemEZ Roof Mount System ComponentsPrimary MaterialsEZ Roof Mount Kit includes: FlashingL-FootRoof Shoe and Gasket4” Lag BoltAL Hex Cap3/8” Flange Nut and BoltK10068-XXXEZ Roof Mount with L-Foot(-001 as shown)EZ Roof Mount Standoff Kit: FlashingL-FootRoof Shoe and Gasket4” Lag BoltAL Hex Cap3/8” Flange Nut and BoltStandoff: 2” shownEZ Metal Roof Mount Kit includes: L-FootMetal Roof Shoe andGasket4” Lag BoltAL Hex Cap3/8” Flange Nut and BoltK10070-XXXEZ Roof Mount with Standoff(Standoff heights: 2”, 3”, 5”and 7”)K10082-001EZ Metal Roof Mount with LFoot(as shown)K20082-002EZ Metal Roof Mount with LTall FootBoth are available in black(-BK1 or BK2)EZ Metal Roof Mount Standoff Kit: L-FootRoof Shoe and Gasket4” Lag BoltAL Hex Cap3/8” Flange Nut and BoltStandoff: 2” shown7 of 29K10064-XXXEZ Metal Roof Mount withStandoff(Standoff heights: 2”, 3”, 5”and 7”)

EZ Pitched Roof SystemAluminum Flashings are offered intwo sizes: 10”X12.5” and 18”X18”.Available in clear, black andbrown

AL Hex Cap Available in clear and black A20066-001 and -BK1 AL Hex Cap Aluminum Shoe is provided with EPDM Sealing Washer installed. A20065-001 AL Shoe C10006-001 Sealing Washer Aluminum Shoe (for metal roofs) is provided with EPDM Sealing Washer installed. A20051-XXX AL Shoe C10007-001 Sealing Gasket 5/16 Stainless Steel Lag Bolts are

Related Documents:

10 Hoop Rack Hoop Rack Heavy Duty Round Rack Arc Rack 11 Swerve Rack Bike Hitch Downtown Rack 12 Bike Bike Rack Cycle Dock 13 Helix Rack Hi Roller Campus Rack Rolling Rack CUSTOM BIKE RACKS 14 Full Custom Designs Image Infusion 15 Logo Racks Icon Hitch Type Rider Racks SPECIALTY RACKS 16 Event Rack Compack R

www.symetrix.co 4 1/2 Rack Mounting Hardware and Cables 1/2 U Filler Panel Filler Panel Used with 19" 1U Rack Tray. 32 1/2 U Surface Mount Bracket Bracket for Surface-mounting Half-rack Units. 32 1 U Rack Tray 19" Rack Tray for Rack Mounting of Half-rack Units. 33 RCA to Euroblock Cable Adapter Cable for Consumer Devices like CDs and DVD Players. 33

10 Getting Started Guide 4 Insert the switch and rail assembly into the rack from the front of the rack. Make sure that the rack-mounting holes on the switch line up to the mounting holes on the rack. 5 Secure the switch to the rack with the rack screws. Fasten the lower pair of screws before the upper pair of screws. See Figure 1-3. Figure 1-3.

2.0 RACK MOUNT INSTALLATION 1. Rack mount installation of the 3U POD is possible with the use of the rack mounting brackets (shipped with the 3U POD). See Figure 4. 2. The rack mounting brackets allow you to rack mount the 3U POD in a 19" enclosure (23" to 19" rack adapters would ha

a Pelican-Hardigg Rack Mount Case. From the ultimate protection of the Classic Rack case, to the removable rack option offered by the SuperMAC Rack case, to the smaller footprints of the MAC Rack

Model 301V lockers, Cycle-Safe’s Pro Park bicycle locker and Inverted U rack, Dero’s Rolling Rack and Hoop Rack, Madrax’s Heavy Duty Winder Rack, Creative Pipe’s CS Series and eLockers, and Thunderbolt rack, and Bike-Up’s Maximin Vertical rack and Ring Rack. The Associati

04 A0126 - Trash Rack 05 A0127 - Trash Rack 06 A0128 - Slotted Drain Detail 07 A0129 - Rib Stiffener Spacing for Steel Box Culverts 08 A0137 - Ladder Detail 09 A0138 - Trash Rack 10 A0139 - Trash Rack 11 A0141 - Cylinder Trash Rack 12 A0144 - Trash Rack 13 A0145 - Trash Rack 14 A0148 - Manhole Cover Detail 15 A0152 - Corrugated Metal Pipe

3 LM 4 F 500 AZ M C - 1 ˆ ˇ Product Number Rack and Pinion Motors Series Name LM: L Series Rack and Pinion Motor Frame Size 2: 60 mm 4: 80 mm Moving Direction of Rack F: Vertical to Mounting Foot Surface B: Horizontal to Mounting Foot Surface Rack Maximum Speed 40: 40 mm/s 90: 90 mm/s 500: 500 mm/s Equipped Motor AZ: AZ Series