DIGITAL EGG INCUBATOR USER'S MANUAL

2y ago
19 Views
2 Downloads
5.73 MB
32 Pages
Last View : 2m ago
Last Download : 2m ago
Upload by : Kamden Hassan
Transcription

L o v e o f l i f e b e g i n s w i t h " R c o m "REV. 3.0DIGITAL EGG INCUBATORUSER'S MANUALKINGSURO MAX 20PUMPPOWERPOWERINLET

ContentsHow to Use Rcom KING SURO MAX 201. Introduction(1) KING SURO 20 Introduction4(2) Safety PrecautionsIntroduction5(3) Identification of Parts and Composition6-7(4) Name & Function of Operation Parts82. Before use(1) What's an Incubation Room?9(2) How to Assemble Main Body9 - 12(3) How to Assemble the EGG VANBefore use12(4) APS Assembly / Speed Control / Tube Replacement/ Storage and Cleaning(5) Humidity & Air Maintenance During Incubation / Dew Condensation13-14153. Incubation(1) Incubator InstallationIncubation16(2) Incubation start / How to Stop Egg Turning / Incubation Termination17 - 184. Function Settings(1) Incubator Initialization / Return to Factory Setting18 - 19Temperature & Humidity Setting /(2) How to Set Abnormal High & Low Temp. Alarm19 - 21How to change Centigrade & Fahrenheit /(3) Work Automatic Pumping System by ForceFunction Settings21 - 225. Management(1) Maintenance after HatchingManagement22(2) How to Disassemble and Clean the Incubator23 - 246. Product Information(1) How to Calibrate the Temperature & Humidity25 - 26(2) How to Replace the Fuse / Frequently Asked Questions (FAQ)26 - 27(3) Troubleshooting28(4) Specification29Product InformationMark ExplanationCaution :Caution mark against a fault that can cause damage, trouble, or failure of incubation.Tip :ProhibitedIt is necessary to keep.Do not disassemble.Remove the power cord from outlet.Do not touch.Ground Connection for preventing electric shock.References or useful suggestions in using KING SURO 20Warning of actions which may be dangerous or cause damage to the incubator.DIGITAL INCUBATORContents3

1. Introduction(1) King Suro 20 IntroductionRcom King SURO20 ?Thanks for using Rcom King SURO20 incubator.SURO is a name of ancient King in GimHae area who born from egg, and he is revivedas Rcom Suro incubator based on experienced incubation technique and best quality management.King SURO incubator is designed to easy and simple use as a customer oriented product, butremember that user's incubation knowledge and proper operation is very important forbest incubation result.Therefore, be sure to read this user's manual carefully before you use.Rcom King SURO offers optimum incubation conditions, but users need to observe and manage allincubation conditions such as species of eggs, temperature or humidity for each incubation period,and incubation circumstance.Also, adjustment by users is available.Features[Main Features]************Luxury design with streamlined egg shaped conceptAutomatic Temp. setting and controlAutomatic Humidity setting and controlArtificial intelligence electronic control device to automatically adjust the cycle of incubator according tothe ambient conditionsAutomatic egg turning function with Auto Egg Van (Cradle)Convenient humidifier with Automatic Pumping System (A.P.S)Clear and transparent large view-windowMinimizing the parasitic bacteria by not using any interior material and using revolutionary hygienicduplicated insulation structure (bottom-egg tray)Variable air control lever to control air amount inside the incubatorApplying RCOM's optimum air flow technology to avoid the fan's air from directly touching egg24 egg capacity in the case of chicken egg sizeEnhanced reliability by applicating Swiss's Sensirion's 3rd generation temperature & humidity sensor[Easy Features] or convertibleAlarm and indicator function for abnormal high or low temperature by drastic and unusual outer temperature changeIncubation data memory function and power outage notification function in case of power outageClosed structure to avoid waterdrops (condensation) on the view window from leaking out of incubatorRotating heater support which conveniently controls the tension of the heaterApplication of Water Nipple to supply water easily for humidificationAutomatic humidification function for minimum 2 minutes (Press button for 10 sec.)Automatic Humidification Pumping System, and precise Speed Regulator VR to control the amount of pumping4 Air Vent Holes for inflow of fresh air from outside to inside by affecting the heat insulation to the minimumNot required to have a balance weight with the optimized incubator design considering the centroid ofincubator's top and bottom when eggs are placed* Different kinds of egg can be placed on egg tray, and Egg divider made of ABS material, which has perfect elasticity.* The bottom of the egg tray is made with embossed skid-resistance floor to prevent young birds from deformity in their leg* The Automatic Pumping System (APS) for accurate humidification, as a pump of silicone tube, is structured tomake tube changed with easy and durable by installing mini roller on the four areas with friction.**********41. Introduction(1) King Suro 20 IntroductionDIGITAL INCUBATOR

1. IntroductionElectrical hazardsDo not use a damagedpower cord or looseoutlet.Risk of electric shock or fire.Be careful the details below when you use.Do not pull the cord whentaking out the power cord,and keep wet hands awayfrom connecting plug.Risk of electric shock or fire.Never pull the plug out ofthe outlet during theincubation period.Incubation will be interrupted.Setting CautionsDo not install in dusty ordirty environment.Risk of damage or fire withinthe incubator.Do not cover theventilating opening.Do not install under thedirect sunlight.Risk of fire or interference withthe incubation process.Install away from heatsources.Risk of damage to the incubatorcase and interference withthe incubation process.Do not disassemble ormodify the incubator inany way.Please ensure that nosmall objects get intothe holes on the incubator.Risk of electric shock or fire.Do not install in moist orhumid environment.Risk of fire or electric shock.Ensure that the incubator isinstalled on a stable surfaceaway from edges.Risk of damage to incubatorand eggs and user fromaccidental knocks or drops.If the incubator soundsstrange or emits smokecontact your servicecenter.Risk of electric shock or fire.Risk of electric shock or fire.Do not insert multipleconnecting plugs in anoutlet.Risk of fire or electrical overload.Do not install in excessivelycold or hot conditions,cigarette smoke, etc.Risk of interference withthe incubation process.Do not use any othernon-standard partsexcept those provided.Risk of damage or hatchingfailure.Do not turn the incubatorupside down.Children should be supervisedto ensure that they do not playwith the appliance.Risk of knocking the incubatoror accidental interference withthe controls.Water will pour out of the incubator,and view window can be droppedor damaged.Clean the incubatorthoroughly before storing.If the incubator requiresrepair disconnect from thepower supply and pleasecontact to your service center.Be sure to disconnect the electric cordfrom the outlet before cleaning.Cleaning CautionsDo not spray cleanserdirectly on the incubatorsurface.Do not twist or crushelectric cord.Be careful the details below when you use.Inner temperature can rise,interrupting incubation.Risk if electric shock or fire.(2) Safety PrecautionsClean the incubator by asoft cloth with a neutraldetergent.Brush away dust on theplug with a dry cloth.Do not use chemicals like wax,benzene, alcohol, thinner,aromatic, or lubricant, etc.For special cleaning ofinner part per year, contactto the service center.If you don't clean the inside ofincubator for a long time, dustcan cause some trouble or a fire.※ This appliance is not intended for use by persons (including children) with reduced physical, sensory ormental capabilities, or lack of experience and knowledge, unless they have been given supervision orinstruction concerning use of the appliance by a person responsible for their safety.DIGITAL INCUBATOR1. Introduction(2) Safety Precautions5

(3) Identification of Parts andComposition1. IntroductionIdentification of PartsMain ControllerPower coverSilicon TubeHumidification NippleView WindowVentilation Control LeverINOUT PET bottle (sold separately)Egg trayAutomatic pumping system(APS)ABS DividerBottom bodyTurning baseFrameEgg Turning MotorAluminum pipeSlip gear61. Introduction(3) Identification of Parts andCompositionDIGITAL INCUBATOR

(3) Identification of Parts andComposition1. IntroductionBasic ComponentsProduct serial No. is indicated inside of main controller.Be careful not to remove the serial No. ex)RCM0950278Rated voltage and product serial No. are marked inside of power cover.Be sure to check this before connecting power.(Power Cap)Egg TrayView windowMain controllerBottom body(1pcs.)Power Cover fixing bolt(Silicon Tube)12.5cm (diameter : Þ 2.6 * 3.5)Nipple (1pcs.)(2pcs.)Egg Van(Cradle)Main Controller Assembly Bolts(210 * 150mm)ExpendablesManualPower CordABS DividerHatching PadHumidity PadAPS ComponentsPumping MotorRollergearPump Frame(Humidity Pad Fixing Use)3.5cm (diameter : ÞPump Main Body2.6 * 3.5)Humi Pad Clip (2pcs.)Silicon Tube and Nipple (2pcs.)Silicon TubePump Casebolt (2pcs.)DIGITAL INCUBATOR1. Introduction1.5m (diameter : Þ 2.6 * 3.5)(3) Identification of Parts andComposition7

(4) Name & Function ofOperation Parts1. IntroductionRcom King SURO 20①②④③⑤⑦⑥⑧[ Name & Function of Operation Parts ]① Heater Operation Lamp- Light on when working⑤ Power Failure Alarm Function- Light on when power failure (Cancel Button : OK)② Temp. Display- Current Temperature Display⑥ Up Button- Setting Temp. & Humidity UP /Calibrated Temp. & humidity UP③ Humidity Display- Current Humidity Display⑦ Down Button④ Pumping System Operation Lamp- Light on when working⑧ Menu Selecting Button- Setting Value check- Setting Temp. & Humidity DOWN /Calibrated Temp. & humidity DOWNSetting Mode: Press two buttons at the same time to go to Setting Mode.Select Menu / Quick Movement /Cancellation / Setting value check during incubationValue / APS is forced to operate if press 5sec. /APS is forced to operate for 2min. if press 10sec.Value - / Factory InitializationFunction Key8Abnormal High Abnormal LowTemp. AlarmTemp. AlarmCentigrade /FahrenheitFunctionTemp.HumidityDispalytEPrHHILO C / FDefault Setting37.5 C45%2 C- 3 C C1. Introduction(4) Name & Function ofOperation PartsDIGITAL INCUBATOR

(1) What is an Incubation Room? /(2) How to Assemble Main Body2. Before useWhat's an Incubation Room?The Incubation Room is a confined space for setting and operating an incubator.Because the incubation room environment has a considerable effect on hatch rate, it's recommended to controlthe environment for setting up an incubator; there should be little noise and vibration around and temperatureranging 28 (82.4 F) with small variation in temperature.Especially, if there are frequent occasions when the temperature drops suddenly at night, compared withdaytime, be sure to check from time to time and pay attention so that the incubator is not directly exposed tosunlight during daytime.※ When the temperature of incubation room is lower than, recomended setting temperature there could bewater-drop in side of incubation room or water leak on the floor. because of dew condensation.PUMPPOWERPOWERINLETINOUTPump PowerEgg Van CordPower CordHow to Assemble[ How to Assemble Main Body ]1Please remove all packing from the incubator and parts.Then, check each part is all present and undamaged.※ Retain the carton and packing materials to enablethe unit to be repacked.DIGITAL INCUBATOR2. Before use(1) What is an Incubation Room? /(2) How to Assemble Main Body9

2. Before use(2) How to Assemble Main Body2Loose two bolts connecting main controller andview window. After that, disassemble main controllerfrom view window by pulling 4 hooks on main controller.3Fix silicone tube which is assembled with nippleinto the hole.NippleBe careful to ensure the silicone tube isnot folded.4Insert the nipple which is connected withview window to the hole of main controller, andassemble view window and main controllerwith two bolts.Do not tighten the bolts too much.102. Before use(2) How to Assemble Main BodyDIGITAL INCUBATOR

2. Before use(2) How to Assemble Main Body5Cut Humidity pad to proper size,and then fix on the view window with 2 pins included.Evaporating ability is different from pad size.Under 50% humidity (Cut to 50mm 55mm)Over 60% humidity (Cut to 70mm 75mm)※ You can use Humidity pad for about 4 6 months, but it can be different from water quality.(Distilled water is good.)※ Humidity pad can be purchased separately.6Assemble bottom body, Tray, and Tray hatching pad.EggEgg TrayHatching PadEnsure hatching pad is placed in egg tray.※ After hatching finished, be sure to wash and drytray mat completely for next use.7Place eggs by adjusting tray divider according to egg size.Control the space of eggs and divider optimallyso the eggs are not interrupted for incubation.It is recommended to place eggs withsharp end side down.DIGITAL INCUBATOR2. Before use(2) How to Assemble Main Body11

2. Before use(2) How to Assemble Main Body /(3) How to Assemble the EGG VAN8Place eggs and cover view window.If view window is not closed completely,temp. fails to go up.How to Assemble the EGG VAN1Insert aluminum pipe to the frame exactly.Place the EGG VAN on the flat surface, and tightenthe bolts.Incubator can drop in case of wrong assembling.m20mDo not turn the incubator manually whenthe incubator is on the EGG VAN.(It can cause egg turning device failure.)2Assemble opposite side with same way.※ EGG VAN turns the incubator and eggs very slowlyabout 90 per an hour.The device can turn irregular intermittently, it is normal.Spray lubricating oil such as WD 40 on the gear part oroperation part of EGG VAN for helping smoothoperation.122. Before use(2) How to Assemble Main Body /(3) How to Assemble the EGG VANDIGITAL INCUBATOR

2. Before use(4) APS Assembly / Speed Control /Tube Replacement/ Storage and CleaningHow to Assemble APS (Automatic Pumping System)35mm1.5m[Pic.1-0]* Is not required with first use[Pic.1-1][Pic.1-3][Pic.1-4]aaa ngDirection[Pic.1-5][Pic.1-6]① Cut the silicone tube exactly to 35mm, and insert to nipple as picture 1-2.(When you purchase, product is originally assembled as -1.)② Cut the silicone tube of 1.5m to half, and insert to assembled nipple .③ It is normal if you assembled as pic.1-3. If you do not insert silicon tube to the nipplecompletely as pic.1-4, pumping will not work well.④ Loose two bolts of APS case as picture 1-0, and insert the assembled silicone tube andnipple as pic.1-3 to the side of pic. 1-5 .⑤ Grip the part on Pic.1-5, and pull the silicone tube so that fit to .(If silicon tube should be assembled tightly.)⑥ Spread IN and OUT of tube so that the silicone tube is not tangled. Insert tube on the groove,and cover the case.Here, be sure to check not the silicone tube or wire get jammed. Refer to the Pic.1-6.DIGITAL INCUBATOR2. Before use(4) APS Assembly / Speed Control /Tube Replacement/ Storage and Cleaning13

2. Before use(4) APS Assembly / Speed Control /Tube Replacement/ Storage and CleaningHow to Control Water Flow Speed in APS The amount of water for humidification can be easilycontrolled with APS. With cross type screw driver, turn "Speed" clockwiseto increase water flow and vice versa to decrease.OUT1 drop per 3 sec. To prevent water over flooding and drop downin the chamber, it is recommended to usethe APS with lowest water flow speed.(1 drop of water in 3 sec.)Humidity will raise up very slowly as artificial intelligence function check and memorize ambientconditions to keep incubator inside with optimum conditions.How to Replace the Tube If the silicone tube wear out and it does not pump water effectively, you should replace siliconetube. [Refer to the page 13]Be sure to use the silicon tube supplied from Autoelex. (Ø2.6 3.5)If water does not flow out even if pumping motor is working, check if silicon tubeis blocked or folded.※ If it failed in pumping water, check direction of IN and OUT again, and also check if motor isturning with anti-clockwise. Also, length of silicon tube should be 35mm and inserted correctly.[Refer to the page 13]Storage and Cleaning Do not wash APS with water but wipe with soft cloth. In case of long time storage, detach the silicon tube from the APS and remove the waterfrom the tube. Keep the tube without kink.It helps the tube hole not block. When assembling again, stretch the tube to open the hole in case the tube is blocked.142. Before use(4) APS Assembly / Speed Control /Tube Replacement/ Storage and CleaningDIGITAL INCUBATOR

2. Before use(5) Humidity & Air Maintenance During Incubation /Dew CondensationHumidity & Air Maintenance During Incubation When hatching, humidity should be relatively high toprevent the thin membrane from drying out or hardeningbefore hatching. When hatching, it's recommended not to openthe lid often.This is because if you open the lid often humidity will berapidly decreased and it will take a long time to regainthe proper humidity.※ If incubatior temperature is higher than 37 and room temperature is low, it may be difficult to maintainhumidity of over 70%. There may be some difference of humidity about 5% according to the externalenvironment, but no problem with hatching. It's very important to maintain humidity higher 1 2 days before hatching than the early and middleincubation periods. Humidity requirements during incubation are 45 55% for waterfowl, 40 45% forpoultry and 35 45% for parrot, in general. One day before hatching, all kinds of birds need about65% humidity and sometimes need higher than that. However, in areas of high ambient humidity,lower levels of humidity may be needed during incubation(Rcom Pro20 incubator automatically controls these conditions according to incubation period.)※ Air Controlling Lever : Outer fresh air can be flowed into incubator inside without affecting insulation.When eggs start hatching, open air controlling lever either fully or half-open.Check water level every three days during incubation, and refill when needed.You'd better to use tap water than purified water or underground water for avoiding evaporating paddamage. (Evaporating pad is available from Autoelex Co.,Ltd. or distributors.)※ Evaporating pad is expendables.※ Dew Condensation This is a naturally occurring phenomenon when there isa significant difference in temperature between insideand outside of the incubator during incubation period.If this occurs, water may form in inside bottom ofthe incubator(bottom part).Do not place any goods near the incubator.DIGITAL INCUBATOR2. Before use(5) Humidity & Air Maintenance During Incubation /Dew Condensation15

3. Incubation(1) Incubator InstallationIncubator Installation1PUMPPOWEPOWERRINLETPlace Suro incubator on the Egg Van( egg turning device).2Open the power cap, and insert the incubatorpower cord and pump power cord.Be careful and ensure the cords do not get jammedwhen you tighten screw bolt.* If you open power cap, there is a sticker whichis showing rated current in the position of pic. .pump power cord power cord3Connect silicon tube end of APS(Automatic Pumping System) into thenipple of incubator, and the otherend into PET bottle.PUMPPOWEBe sure to check rated current Pic. beforeconnecting power cord to outlet.Pressbutton for about 10 sec. forpump operation, and it automatically stopafter 2min. If you want to stop pumpoperation, press any key.POWERRINLETINOUTPump PowerEgg Van CordPower CordIf you do not insert silicon tube exactly, it will not work properly.[Refer to the page 13. How to replace silicon tube.]163. Incubation(1) Incubator InstallationDIGITAL INCUBATOR

3. Incubation(2) How to Start IncubationHow to Start Incubation If you connect power cord, incubator startsincubation with factory set conditions.(Factory setting : Temperature 37.5 C,Humidity 45%)PUMPPOWERPOWERINLET※ Start incubation with required temperature &humidity for your species of birds. With incubation start, be sure to placethe incubator on the egg van foregg turning. ( 90 degree per an hour.)Pump PowerEgg Van CordPower CordThere can be some odor the first timeyou use incubator, which is normal. The first time you connect power, FND light willblink and pump will work for about 2sec.Then, incubator version will be indicated on FNDfor about 1 sec.① After version indication, buzzer sounds for about15sec. At the same time, present temp. & humiditydisplayed and power failure alarm indication is blinking. Pressbutton to remove buzzer and alarmindication.(Buzzer will be removed automatically after 15sec.)※ Notice of Power Failure : If power is turned offand then on again because of power failure orby mistake, first dot will blink.②Quick Start : If you just connect power,it automatically starts incubation with factory setting.(Factory setting : Temperature 37.5 , Humidity 45%) Incubator display current temperature and humidity,and it goes to setting conditions within an hour.※ The artificial intelligence system memorizes and classifies ambient conditions for keeping optimumtemperature, and temperature can move up slowly at the first stage.DIGITAL INCUBATOR3. Incubation(2) How to Start Incubation17

3. Incubation(2) Incubation Start / How to Stop Egg Turning /Incubation Termination / 4.(1) Incubator InitializationTurning stop During IncubationPUMP Before 3 days of hatching, disassemble the incubatorfrom EGG VAN, and place on flat surface for stoppingegg turning. After that, you'd better to remove Divider.POWEPOWERRINLETHere, be sure to remove Egg Van power cord only.Be careful not to take off power cord of incubator. When incubating various species of eggs at the sametime, you can move the eggs before three days ofhatching to other brooder for easy and clean management.(You can operate two incubators, and various incubators or brooders are available fromRcom website .)In case of altricial birds such as parrots or wild birds, you'd better to turn the eggs once ortwice additionally by your hand.Incubation Termination※ There is no specified ON or OFF buttonon the incubator.PUMPPOWERPOWERINLET Just take off the power cord after hatching.INOUT It is not necessary to do IncubatorInitialization with KING SURO 20 incubatorafter hatching. Just connect power againwhen you want to start incubation again.Pump PowerPower CordIncubator Initialization This function can be used when user inputwrong setting, or incubation termination. Pressandbutton at the same timefor about 5sec. then display will show "rSt" andincubator returns to default setting.5sec.Calibrated setting value will not be initialized withthis function.[If you need to initialize calibrated setting,refer to FACTORY SETTING next page.]183. Incubation(2) Incubation Start / How to Stop Egg Turning /Incubation Termination / 4.(1) Incubator InitializationDIGITAL INCUBATOR

(1) Return to Factory Setting /(2) Temperature Setting4. Function SettingsReturn to Factory Setting This function is for return incubator to factory setting.PUMPPOWERPOWERINLETPower Cord Unplug power cord. Replug duringbuttonis pressed. Then, "rSt AL" will indicated in display,and incubator return to factory setting.(Default setting)OUTSPEEDCalibrated temperature and humidity will alsoreturn to factory setting.Temperature Setting Pressandbutton at the same timethen “ tEP ” will be indicated for about 0.5sec.and then temp display will blink. Then, you can adjust temperature withandbutton. (Default setting: 37.5¶ C) After setting required temperature, pressbuttononce then setting will be stored.Next, “rH” will indicated in humidity display forabout 0.5sec. and then humidity display will blink.※ Just presssetting.button if you do not need to changeTemp. UPDIGITAL INCUBATOR4. Function SettingsTemp. Down(1) Return to Factory Setting /(2) Temperature Setting19

(2) Humidity Ssetting /How to Set Abnormal High Temp. Alarm4. Function SettingsHumidity Setting When humidity display is blinking, adjust humiditysetting withorbutton.(Default setting : 45%) After setting required humidity, pressbuttononce then setting will be stored. Next, “HI” will beindicated for about 0.5sec. and then maximumtemperature limit will blink.※ Just presssetting.button if you do not need to changeFunction KeyAbnormal High Abnormal Low Centigrade /Temp. AlarmTemp. LO C / FDefault Setting37.5 C45%2 C- 3 C CHumidity UPHumidity DownIncreaseDecreaseHow to Set Abnormal High Temperature Alarm Adjust abnormal high temperature value withorbutton. (Default setting : 2 C) After setting required value, pressbutton to save.Then, it will go to the next stage, abnormal low temp.setting with display "LO" for about 0.5 sec.Abnormal High temperature:This function gives notice when incubatortemperature is higher than setting temperaturebecause of abnormal ambient temperature increase.When room temperature is higher than incubatortemperature, this function works with buzzer.Here, "HI" and temp. gap are displayed alternatively.Press OK button to remove buzzer.204. Function Settings(2) Humidity Ssetting /How to Set Abnormal High Temp. AlarmDIGITAL INCUBATOR

(3) How to Set Abnormal Low Temp. Alarm /How to change Centigrade & Fahrenheit4. Function SettingsHow to Set Abnormal Low Temperature Alarm This function gives notice when incubator temperatureis lower than setting temperature because of abnormalambient temperature decrease. Adjust abnormal low temp. setting withbutton. (Default setting : -3 C)or After setting required value, pressbutton to save.Then, it will go to the next stage, C & F change.Abnormal Low Temperature: " LO" will indicatedon LCD.(The others, same with abnormal high temp. alarmfunction.)IncreaseDecreaseHow to change Centigrade & Fahrenheit Select C or F withor After selecting C or F , pressbutton.button to save.(Default setting : C )How to change Centigrade value to Fahrenheit C 5/9 ( F - 32)DIGITAL INCUBATOR4. Function Settings(3) How to Set Abnormal Low Temp. Alarm /How to change Centigrade & Fahrenheit21

4. Function Settings(4) Work Automatic Pumping System by Force /5.(1) Maintenance after HatchingHow to Work Automatic Pumping System(APS) by Force Pressbutton for about 5sec. during incubationprocess. Then, PUMP will operate by force withLED light on.Pump operation by force Pressbutton for about 10sec. then pump motorworks for 2min. by force. It still works for 2min. evenif you remove your finger from the button.If you pressbutton for about 10sec.pump will operate for about 2min.Press any key to remove.During pump operationMaintenance after Hatching Because newly-born chicks just after hatching havelittle protection against cold, a brooding room shouldcertainly be prepared in advance for them. In casethere is no separate brooder prepared, you maylet them stay in the incubator for one day or more afterhatching.If you move them to a brooder or brooding box,the inner temperature should be kept at 35 37 .For the production method of a simple brooder, pleaserefer to our website www.Rcom.co.kr.PUMPPOWERPOWERINLET As there is some difference in chick feed for each kind ofbird, so it's desirable to obtain useful information aboutthe chicks before hatching.224. Function Settings(4) Work Automatic Pumping System by Force /5.(1) Maintenance after HatchingDIGITAL INCUBATOR

(2) How to Disassemble andClean the Incubator5. ManagementHow to Disassemble and Clean the IncubatorBe sure to take off power cord beforecleaning the incubator.PUMP After incubation terminated, never leavethe incubator covered with view window.Then, moisture inside of the incubatorvaporizes and it can stick to electric partso that cause operation failure.Be sure to remove view window anddry the incubator perfectly.POWEPOWERRINLETINOUTPump Power Remove main controller fromview window. [Refer to the page 10]Power Cord Wipe the main controller smoothly with soft brush.Be careful not to give impact to sensor partor heating part. Temp. & Humidity sensor is assembled withconnector for easy replacement in case of trouble.DIGITAL INCUBATOR5. Management(2) How to Disassemble andClean the Incubator23

5. Management(2) How to Disassemble andClean the Incubator Wash the window, tray, hatching pad and mainbody with warm water. Do not wash EGG VAN and Automatic PumpingSystem(APS) with water, and just wipe withsoft cloth.Do not use benzene or thinner when wipe the unit.It can cause transformation or decoloration Wipe the exterior with soft cloth, and thencompletely dry before store.245. Management(2) How to Disassemble andClean the IncubatorDIGITAL INCUBATOR

(1) How to Calibratethe Temperature & Humidity6. Product Information※ This calibration function is for resetting incubatortemp. or humidity with user's thermometer or hygrometer.As incubator is already calibrated from factory withinternational standard, so it is not recommendableto the user's calibrate by themselves. In case calibrationis required, users can do this with their thermometer orhygrometer.Thermometeror HygrometerHatching PadSensorSpread egg tray mat on the bottom of tray,and stablethe incubator temperature by operating for an hourbefore calibration.And then, observe the temperature or humidity atseveral position above 10mm of the hatching pad withyour thermometer, and calibrate with average value.Egg Tray10mmLow priced thermometers or hygrometers which you can easily purchase from the market havelarge deflection of measurement. This could cause hatching failure, and it is recommendedto use highly precise thermometer or hygrometer.Temperature Calibration Press,andbutton at the same time.Then “CA” will indicated for about 0.5sec, andit changes to current temperature.(CA means Calibration.)If you want to increase the temperature 0.5 C,Please reduce 0.5 C in calibration setting mode. You can control temperature by 0.1 C withandbutton. Pressbutton a

incubator's top and bottom when eggs are placed * Different kinds of egg can be placed on egg tray, and Egg divider made of ABS material, which has perfect elasticity. * The bottom of the egg tray is made with embossed skid-resistance

Related Documents:

Smart Egg Incubator is 32cm height x 45cm width x47cm long. For this, 4 bulbs were placed around the wall inside of the Smart Egg Incubator. The bulb usage is 40 Watt’s that supply heat to the egg. Figure 8: The casing box for Smart Egg Incubator Refer to Figure 8 above; it is show about the 4 dimension c

144 digital egg auto turn 288 digital egg auto turn 720 Digital egg auto turn Description Pack Size Retail Inc GST % Bulk Discount Bulk No IM Incubator 144 egg digital auto tilt turn with hatching tray 1760.00 1 IM Incubator 288 egg digital auto tilt

control of the incubator could affect the temperature and humidity of the incubator to become higher or lower. In this project, a small bulb is located inside the incubator to provide suitable temperature for the quail eggs. In order to maintain the good condition of humidity and ventilation, the incubator is

cost homemade egg incubator for production of chicks and ducklings. He has developed a low cost homemade egg incubator where 200 eggs can be incubated at a time. Developmental cost of this incubator is approximately Rs. 5000. One of the important feature of this incubator is electricity can be substituted by kerosene lamp.

the egg production facility. This processing method is the most efficient egg collection and processing of eggs available. Eggs are delivered from the egg production facility to the egg processing facility by an enclosed and refrigerated conveyor system. Egg handling and processing is performed with automated equipment.

2.2 Description of the Incubator The incubator, fig. 1 was made of wood and has height of 2050 mm, breadth 1110 mm and width 630 mm. It is a forced draft type incubator in which a fan was used to circulate the air, which gives a uniform temperature throughout the machine. This helps to overcome the tempera

_ 6. Kendra owns a restaurant. She charges 3.00 for 2 eggs and one piece of toast, and 1.80 for one egg and one piece of toast. How much does Kendra charge for an egg? A piece of toast? a. 1.20 per egg; .60 for toast c. .60 per egg; .60 for toast b. .60 per egg; 1.20 for toast d. 1.20 per egg; 1.20 for toast

Both the ISO 14001 and the Responsible Care requirements shall be included in order for an organization to receive certification of its RC14001 management system. ISO 14001 This Technical Specification document includes relevant provisions of the text of international standard ISO-14001:2004 – Environmental Management Systems. The text of ISO14001 is the first set of requirements in each .