CLINGSUPERAIRAir purification system

Content01.SUPERAIR-IOzone air purificationsystem02.SUPERAIR-IIAn i o n a i r p u r i f i c a t i o nsystem03.SUPERAIR-IIIPhotoelectric plasmapurification systemSUPERAIR

1. SUPERAIR-IOzone air purification systemEasy control:Powered by wire harness.Manualy open and close.Function:Release ozone to kill bacteria in the air.Input voltage:DC16-28VPower: 5WOzone output volume:800-1000mg/hrEasy installation: places with good ventilationApplication:8-12m bus & coach(return air grille, air duct, etc)Features:

2. SUPERAIR-IIAnion air purification system Easy control Function:1、Powered by wire harness;It releases negative ions and2、Manually open and close; Features:adsorbs bacteria and particlesin the air.1、 Easy installation on evaporator or air return port;2、Easy to replace and maintenance;

Specification:Voltage/ current:DC24V / 30mAEnvironment temperature/ humidity:-10 C—45 C/ 15%—60%Lifespan:2000 HoursAnion generating volume:2 millionDimension:210*47*36 mm

3. SUPERAIR-III P h o t o e l e c t r i cplasma purification systemPrinciple:By implementing tip discharge onindividual small units, a largenumber of ion groups arereleased to collide with oxygenmolecules to form positive andnegative oxygen ions.1. Decompose thepollution factors inthe air,Functions3. Eliminateparticulatematter in the airto achieve thepurpose ofpurifying the air.2. Kill bacterialin the air,Tip dischargeIon amount: 2000 * 10 6 / cubic

Specific of Photoelectric plasma purification systemInput voltage:24vMaximum ratedpower: 15WConnectormodel:AMP282107-1Connection:Wire harness*Operatingtemperature: 40 C 80 COperatinghumidity: 0%RH-95% RHIon amount: 2000 * 10 6 /cubic* CAN communication is optional

Ultraviolet disinfection system1, Structure:The ultraviolet lamp tube and the photoelectric plasma purification systemare integrated inside the return air grille, easy installation and replacement.2, PrincipleUse the appropriate wavelength of ultraviolet rays to destroy the molecularstructure of DNA or RNA in the cells of the microbial body to achieve theeffect of sterilization and disinfection.3, Function:Irradiation within 1.5-2 meters of the UV lamp tube for 20 minutes can kill99% of bacteria.4, Maintenance:Purifier clean-free maintenanceThe UV lamp is guaranteed for 8000 hours; if UV lamp is placed for morethan 1.5 month). Before use,pls heat the UV lamp tube by hot air blower toactivate the gas in the UV lamp tube and accelerate the UV lamp to enterthe working state. If there is no heating condition, the electronic air purifiercan be directly powered on, and the gas in the lamp tube of the ultravioletlamp can be activated by electric current. In this way, the time for theultraviolet lamp to enter the working state is relatively slow.

InstallationEvaporatorBusbodyINSTALLATIONA/C

SUPERAIR-IV-ASpecification:Voltage/ current:DC24V 1.67AEnvironment temperature:-40 C—80 CLifespan:8000 HoursAnion generating volume:20 millionDimension:630*180*40 mm

Specification:SUPERAIR-IV-BVoltage/ current:DC24V / 1.46AEnvironment temperature:-40 C—80 CLifespan:8000 HoursAnion generating volume:20 millionDimension:440*180**40 mm

ThanksMore info at: www.clingac.com

The UV lamp is guaranteed for 8000 hours; if UV lamp is placed for more than 1.5 month). Before use,pls heat the UV lamp tube by hot air blower to activate the gas in the UV lamp tube and accelerate the UV lamp to enter the working state. If t

Related Documents:

3.8 manual stretch cling film mode of stretch cling film wrapping manually 3.9 tear propagation resistance It is a force required to extend a tear of stretch cling film 4. Types Stretch film shall be classified into the following grades, a) Grade 1 — Manual stretch cling film. b) Grade 2 — Power stre

changes, whereby the feasibility of wrapping the remains to ensure the containment of the decomposition fluid within the cling film plastic wrap. 3 unknown and unclaimed dead bodies were used, where a fresh and decomposed body were cling-wrapped, and another fresh body

before me, completely wrapped in cling-!lm. "e pleasure is unexampled. “You are completely wrapped in cling-!lm,” I say. “You win the bet,” says Roy, mu#ed. “Now unwrap me.” “Not for several hours.” “Ah.” I sit and admire my handiwork for a

Hole-makers do not experience life and growth. They cling to their _ _. Conversation Guide 1. Share with the group your faith/fact labels. 2. Why do you think we cling to our shovels (faulty assumptions) rather than cling to truth? hole makers invested traded

individual purification methods based solely on their purification factor. Context is paramount. It is impossible to predict what combination of separation methods will work best for a given virus purification process, and how many steps will be required to achieve the degree of purification required to support a particular application. Development

innovation since the late 1970s. Our research scale purification instruments are the most technologically advanced and effective purification systems available. Our method development and purification algorithms help scientists convert traditional regular flash purification to faster, greener, and more economical processes for reliably isolating

Magnetic beads for DNA purification 9 Genomic DNA purification kits 10 Genomic DNA extraction 16 Genotyping—pharmacogenomics studies 17 Plant genomic DNA isolation kits 18 Viral genomic DNA purification kits 20 Genomic DNA from saliva 21 Complete purification system for nucleic acids

Precision Air 2355 air cart with Precision Disk 500 drill. Precision Air 2355 air cart with row crop tires attached to Nutri-Tiller 955. Precision Air 3555 air cart. Precision Air 4765 air cart. Precision Air 4585 air cart. Precision Air 4955 cart. THE LINEUP OF PRECISION AIR 5 SERIES AIR CARTS INCLUDES: Seven models with tank sizes ranging from