DISTRIBUTED BY Technical Data Guide7For more informationOr to buy this product07 14 00Fluid-AppliedWaterproofingClick hereMasterSeal HLM 5000 Liquid, cold-applied elastomeric waterproofing membrane systemFORMERLY SONOSHIELD HLM 5000DESCRIPTIONYIELD25–30 ft2/gal at 55–65 wet mils(0.61–0.74 m2/L at 1.4–1.7 mm wet thickness)MasterSeal HLM 5000 is a one-component, moisture-curing, bitumen-modified polyurethaneelastomeric waterproofing membrane for exterior below-grade or between-slab applications. It isavailable in four grades:25–30 ft2/gal at 45–55 dry mils(0.61–0.74 m2/L at 1.1–1.4 mm dry thickness)Coverage may vary with the applicationtechnique used. Actual coverage rate and milthickness depend on finish and porosity of thesubstrate.STORAGEStore in unopened containers in clean, dryconditions at 40 to 80 F (4 to 27 C). Duringstorage, an easily removed skin of HLM 5000may form, which does not affect performanceof the product.SHELF LIFE– 1 Year Pails– 6 Months DrumsVOC CONTENT– MasterSeal HLM 5000 SL: 183 g/L– MasterSeal HLM 5000 S: 190 g/L– MasterSeal HLM 5000 R: 180 g/L– MasterSeal HLM 5000 T: 132 g/LMasterSeal HLM 5000 SL (self-leveling/squeegee) MasterSeal HLM 5000 S (spray)MasterSeal HLM 5000 T (trowel)MasterSeal HLM 5000 R (roller)PRODUCT HIGHLIGHTS Available in standard and high-build systems Waterproofing membrane to prevent water penetrationElastomeric accommodates expansionand contractionWide service-temperature range, makingMasterSeal HLM 5000 suitable for all climatesChemical resistance to bacterial attack, selectacids, alkalis and saltsSeamless cold-applied membrane eliminateslapping, seaming and precuttingDoes not require hot-melt equipmentAPPLICATIONS Concrete Plywood (exterior) Exterior below grade (on masonry, concrete, and incidental metal)Above grade (between two-course concreteand within cavity walls)Parking garages and concrete tanksPlaza decks and mallsFountains and poolsBalconies and plantersBelow-grade slabsWalls and culvertsSea walls, dams and reservoirsPACKAGING MasterSeal HLM 5000 SL, HLM 5000 S, andHLM 5000 R: 5 gal (18.95 L) pails, 55 gal (208L) drums; available special order MasterSeal HLM 5000 T: 5 gal (18.95 L) pails MasterSeal 995: 300 ft by 37½" (91 by 0.9 m)rolls, yielding 937 ft2 (87 m2) MasterSeal 977:- 50 mil by 40" by 48" (1.3 mm by 1 m by 1.2 m)sheets, 500 per pallet, yielding 131 3 ft2 (1.2 m2)per sheet or 6,665 ft2 (619 m2) per pallet.- 120 mil (1 8") by 40" by 48" (3 mm by 1 m by1.2 m) sheets, 500 per pallet, yielding 131 3 ft2(1.2 m2) per sheet or 6,665 ft2 (619 m2) perpallet.HOW TO APPLY MASTERSEAL HLM 5000SURFACE PREPARATION1. For best results, all concrete deck surfacesshould be lightly steel troweled to a flat,uniform surface. A light broom finish isacceptable. New concrete must be properlywater cured at least 14 days. Membrane curingcompounds must be mechanically removed.A brand w.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.com

Distributed by Best Materials LLCTechnical Data GuideMasterSeal HLM 5000Technical Data CompositionMasterSeal HLM 5000 is abitumen-modified polyurethane.Compliances ASTM C 836 National standard of Canada 37.58 - M86developed by CGSBRESULTSTEST METHODHardness, Shore OON/A85Viscosity, poiseHLM 5000 SLHLM 5000 SHLM 5000 RHLM 5000 T1254508004,000Tensile strength, psi (MPA)200 (1.4)150 (1.0)ASTM D 412Average elongation, %3001600ASTM D 412100% modulus, psi (Mpa)80 (0.6)80 (0.6)ASTM D 412-40 (-40)120 (49)Moisture-vapor permeability,dry perms0.0750.1ASTM E 96Passed ¼";no loss of bond oror cracking exhibitedPassed 1 16";no loss of bondor cracking exhibitedASTM C 836VALUECrack bridging test,cycled 10 times per24 hours at 15 F (-9 C)No crackingASTM C 836VALUEMinimum recovery, %90Swelling in water,3 days at room temperatureNilMASTERSEAL 995PROPERTYPROPERTYStandardSystemHLM 5000Service temp. range, F ( C)MinimumMaximumHLM 5000 (self-leveling grade)High-BuildSystemTypical PropertiesPROPERTYTest DataExtensibility after heat agingBrookfieldWidth, inMinimumMaximum371/2381/2Adhesion in peel, lbs/in(1 lb/in minimum)Length, ft300Weight loss, % (20% max)Thickness, in(FTM-5136) 0.024(-0.0, 0.002)Results shown are typical but are not intended as performance criteria for on-site installed material.1Tested in direction of greatest elongation of fabricNominal weight, oz/yd22.13Construction, in34 by 30Yarn denier702ASTM C 8365ASTM C 83616http://www.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.comASTM C 836

Distributed by Best Materials LLCMaster Builders sterSeal 995PROPERTYRESULTSElongation, %Machine directionCross direction54147Grab breaking, lbsMachine directionCross direction5432Mullen burst, psi70TEST METHODASTM 5034ASTM 5034MasterSeal 977PROPERTYRESULTSTEST METHODWeight, lbs/ft250 mil120 mil0.1880.428Burst strength, psi (MPa)175ASTM D 2529Puncture resistance, in-lbs45ASTM D 781Test results are averages obtained under laboratory conditions. Reasonable variations can be expected.MASTERSEAL 976CORECompressive Strength(ASTM D-1621)Thickness(ASTM D-1777)Flow (Hydraulic gradient 1)(ASTM D-4716)FABRIC21,000 psf1005 kNm2.40 in1.016 cm23 gpm/ft width286 lpm/m widthFlow (ASTMD-4491)60 gpm/ft22460 lpm/m2MASTERSEAL 975CORECompressive Strength(ASTM D-1621)Thickness(ASTM D-1777)Flow (Hydraulic gradient 1)(ASTM D-4716)FABRIC15,000 psf(719 kNm2).40 in(10.16 mm)21 gpm/ft width(260 lpm/m width)Flow (ASTMD-4491)140 gpm/ft2(5704 lpm/m2)MASTERSEAL 974CORECompressive Strength(ASTM D-1621)Thickness(ASTM D-1777)Flow (Hydraulic gradient 1)(ASTM D-4716)FABRIC11,000 psf(528 kNm2).40 in(10.16 mm)18 gpm/ft width(223 lpm/m width)Flow (ASTMD-4491)http://www.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.com140 gpm/ft2(5704 lpm/m2)

Distributed by Best Materials LLCTechnical Data GuideMasterSeal HLM 50002. For extremely porous block: Prime with a coatof MasterSeal HLM 5000 diluted up to 25% withMasterSeal 990 or xylene. Or apply a parge coatof MasterSeal 581 at the rate of approximately400 ft2 (37.2 m2) per bag and allow to cure aminimum of 7 days before applying MasterSealHLM 5000.3. Remove dust, dirt and other contaminants justbefore or during application. Surfaces must bedry at the time of application.4. Air-void pockmarks or honeycombs must beopened up to allow MasterSeal HLM 5000to fill the cavities completely. Air entrapmentwithin voids may cause blisters. Extremecases may require additional repair.PRESTRIPING1. Before applying the final membrane, all joints,cracks and openings around protrusionsmust be sealed by caulking or prestriping (apreliminary coating of MasterSeal HLM 5000applied with a trowel or stiff-bristled brush).Allow to dry overnight before applying finalmembrane.2. When the final membrane is applied, theoverall thickness over joints and cracks, atcoves and around penetrations should beapproximately 100 wet mils (2.5 mm) on thestandard system.SSPC-NACE2 and prime immediately withMasterSeal P 173. Provide appropriate cantwith MasterSeal NP 1 or NP 2 sealants toeliminate 90 angles.VENT, DRAIN PIPE, AND POST PENETRATIONSClean metal surfaces to bright metal andprime with a quality rust-inhibiting metalprimer followed by MasterSeal P 173 or P176. Remove dust, debris and any othercontaminants from voids. Seal with theappropriate sealant.APPLICATIONA test application is always recommendedbefore proceeding with entire application.NOTE: Finish coat must be applied in apinhole-free, continuous membrane forwaterproofing integrity.STANDARD SYSTEM1. Select the grade of MasterSeal HLM 5000 thatbest meets individual job requirements. UseMasterSeal HLM 5000 T for trowel application,MasterSeal HLM 5000 S for spray application,MasterSeal HLM 5000 R for roller applicationorMasterSeal HLM 5000 SL for squeegeeapplication.2. For horizontal applications, empty contentsof pail and spread immediately to ensureworkability. Best results are obtained by markingSTATIC JOINTS AND CRACKSoff 125 ft2 (11.61 m2) areas and evenly spreadingJoints and cracks less than 1 16" (1.6 mm)should be filled by prestriping. Apply materialthe contents of a 5 gallon (18.93 L) unit withso it both fills and overlaps the joint or crack to a rubber-edged notched squeegee. Repeata width of 4" (102 mm) on each side.the above procedure until the entire surface iscovered.WORKING OR EXPANSION JOINTS3. For vertical applications, apply by trowel, rollerAll joints over 1 8" (3 mm) must be sealed withor spray at the rate of 25 ft2/gallon (0.6 m2/L).a Master Builders Solutions urethane sealant.Best results are obtained by marking off 125 ft2Any working joint less than 1 8" (3 mm) should(11.6 m2/L) and evenly applying the contents ofbe routed to a minimum of 1/4" (6 mm) anda 5 gallon (18.93 L) pail.filled with a sealant. Prevent the waterproofing4. Verify the applied thickness with a wet milmembrane from adhering to the joint sealant,gauge as the work progresses.which could cause sealant or membrane5. The integrity of the cured membrane on afailure, by applying a coat of wax or bondhorizontal surface may be verified by dammingbreaker tape over the cured sealant and thenthe entire area and flooding with water to aprestriping.minimum depth of 2" (51 mm) and allowingthe water to stand for 24–48 hours. VisuallyUNCOATED METAL SURFACESinspect the bottom surface to check for anyRemove dust, debris, and any otherwater penetration. If repairs are necessary,contaminants from vent, drain pipe andthe area should be drained and allowed to drypost penetrations, reglets and other metalbefore reapplying MasterSeal HLM 5000. Aftersurfaces. Clean surfaces to near white perreapplication, the area should be tested again formembrane integrity.HIGH-BUILD SYSTEMConcrete application: Apply 60 wet mils ofMasterSeal HLM 5000, followed by settingMasterSeal 995 reinforcing fabric into the wetmaterial. Overlap all seams a minimum of 3"(76 mm). Additional material may be requiredto properly embed the reinforcing fabric whereit overlaps. Allow the first coat to cure overnightand follow with a second 60 wet-mil applicationof MasterSeal HLM 5000.Plywood application: All plywood constructionmust comply with APA (American PlywoodAssociation) standards. Caulk all joints witha Master Builders Solutions sealant and thenproceed with the MasterSeal HLM 5000 highbuild system.SPRAY EQUIPMENTFor spray equipment recommendations,consult the equipment manufacturer.CURINGAppreciable properties develop within 24–48hours at 75 F (24 C) and 50% relative humidity.Protect MasterSeal HLM 5000 from traffic duringcuring.DRAINAGE AND PROTECTION1. For protection during backfill and wherehydrostatic pressure is anticipated, use theappropriate MasterSeal 975 Drain BoardSystem for installation instructions.2. For protection during backfill only, installprotection board as soon as possible followingcure of MasterSeal HLM 5000.CLEAN UPClean all tools and equipment immediatelyafter application with MasterSeal 990.HOW TO APPLY MASTERSEAL 977SURFACE PREPARATION1. Waterproofing membranes must be protectedagainst tear, puncture, and other abusesduring placement of concrete wearing slabsand reinforcing steel. They should also beprotected from jobsite traffic and backfillingoperations.2. All specifications calling for membranewaterproofing should also require protectionof membrane as an integral part of the overallwaterproofing system.http://www.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.com

Distributed by Best Materials LLCMaster Builders PLICATIONInstall overlapping MasterSeal 977 protectionboard as soon as possible following cure ofthe liquid membrane. Protect MasterSealHLM 5000 from traffic before placement ofprotection board. MasterSeal HLM 5000 mustbe cured before installation of any topping. polyethylene sheeting should be usedbetween the MasterSeal HLM 5000 and thedrainage mat.MASTERSEAL 977 Store MasterSeal 977 on a flat surface andkeep it dry; do not remove shrink wrap untilimmediately before use. If board is exposed to prolonged periods ofwater immersion or excessive humidity, it maycurl or wrinkle.FOR BEST PERFORMANCE MasterSeal 977 to be covered with aMASTERSEAL HLM 5000concrete wearing course must be securelyApply MasterSeal HLM 5000 when substratesattached to membrane.are dry and air temperatures are 40 to 90 F(4 to 32 C); for application at temperaturesGENERALbelow 40 F (4 C), consult Technical Services. Proper application is the responsibility of theTemperatures influence viscosity and handlinguser. Field visits by Master Builders Solutionscharacteristics of MasterSeal HLM 5000: heatpersonnel are for the purpose of makingincreases and cold decreases the flow. Keeptechnical recommendations only and not forMasterSeal HLM 5000 cool in hot weather andsupervising or providing quality control on thewarm in cold weather.jobsite.Avoid application when inclement weather ispresent or imminent.Do not apply to reinforcing bars or to wet orHEALTH, SAFETY AND ENVIRONMENTALcontaminated surfaces.Read, understand and follow all Safety DataDo not directly heat containers with flame,Sheets and product label information for thisstove, hot plate or oven.product prior to use. The SDS can be obtainedPatch all voids and deep depressions inby visiting www.master-builders-solutions.com/substrates with appropriate patching materialen-us, e-mailing your request to mbsbscst@before applying MasterSeal HLM 5000.mbcc-group.com or calling 1(800)433-9517.Use MasterSeal 550 under thin-set tileUse only as directed.applications.IN CASE OF EMERGENCY: Call CHEMTELBefore applying MasterSeal HLM 5000, dam 1 (800) 255-3924 or if outside the US orall drains and drain openings.Canada, 1 (813) 248-0585.Carefully work material over irregular concreteto avoid pinholes and holidays.Protect MasterSeal HLM 5000 coated surfacesLIMITED WARRANTY NOTICEfrom puncture with protection board untilMaster Builders Solutions Constructionrequired topping or backfill is placed.Systems US, LLC (“Master Builders”) warrantsNot intended as an exposed or wearingthis product to be free from manufacturingsurface.defects and to meet the technical propertiesDo not use where a solvent odor ison the current Technical Data Guide, if usedobjectionable, e.g., near areas where foodas directed within shelf life. Satisfactorypreparation or processing occur during theresults depend not only on quality productsapplication.but also upon many factors beyond ourSpecify wet or paper curing for concrete tocontrol. MASTER BUILDERS MAKES NObe coated with MasterSeal HLM 5000; avoidOTHER WARRANTY OR GUARANTEE,using liquid curing compounds.EXPRESS OR IMPLIED, INCLUDINGIn horizontal applications concrete must beWARRANTIES OF MERCHANTABILITY ORslopped to drain to avoid ponding water on theFITNESS FOR A PARTICULAR PURPOSEsurface of MasterSeal HLM 5000WITH RESPECT TO ITS PRODUCTS. TheWhen using drainage mat directly oversole and exclusive remedy of Purchaser forMasterSeal HLM 5000, a layer of 6 milany claim concerning this product, includingbut not limited to, claims alleging breachof warranty, negligence, strict liability orotherwise, is shipment to purchaser ofproduct equal to the amount of product thatfails to meet this warranty or refund of theoriginal purchase price of product that failsto meet this warranty, at the sole option ofMaster Builders. Any claims concerning thisproduct must be received in writing within one(1) year from the date of shipment and anyclaims not presented within that period arewaived by Purchaser. MASTER BUILDERSWILL NOT BE RESPONSIBLE FOR ANYSPECIAL, INCIDENTAL, CONSEQUENTIAL(INCLUDING LOST PROFITS) OR PUNITIVEDAMAGES OF ANY KIND.Purchaser must determine the suitability of theproducts for the intended use and assumesall risks and liabilities in connection therewith.This information and all further technicaladvice are based on Master Builders’ presentknowledge and experience. However, MasterBuilders assumes no liability for providing suchinformation and advice including the extent towhich such information and advice may relateto existing third party intellectual propertyrights, especially patent rights, nor shall anylegal relationship be created by or arise fromthe provision of such information and advice.Master Builders reserves the right to make anychanges according to technological progressor further developments. The Purchaser of theProduct(s) must test the product(s) for suitabilityfor the intended application and purposebefore proceeding with a full application ofthe product(s). Performance of the productdescribed herein should be verified by testingand carried out by qualified experts.FOR PROFESSIONAL USE ONLY. NOT FORSALE TO OR USE BY THE GENERAL PUBLIChttp://www.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.com

Distributed by Best Materials LLCTechnical Data GuideMasterSeal HLM 5000Dynamic Crack DetailVent/Drain/Pipe/Post Penetration DetailAsphalt Pavement Topping/Expansion JointWaterproofing at Bi-Level DrainSplit Slab with Cant Detailhttp://www.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.com

Distributed by Best Materials LLCMaster Builders pansion Joint DetailInside Corner Detail (Static)Static Crack/Prestripe DetailWaterproofing Foundation WallsMaster Builders Solutions Construction Systems US, LLC889 Valley Park Drive, Shakopee, MN er Service 1 (800) 433-9517Technical Service 1 (800) 243-6739 MBCC Group, Form No.1017900 rev 04/2021 registered trademark of a MBCC Group member in many countries of the worldhttp://www.bestmaterials.com 4-7570.com 1-800-474-757sales@bestmaterials.com ales@bestmaterials.comhttp://www.bestmaterials.com 1-800-474-757sales@bestmaterials.com 1-800-474-7570http://www.bestmaterials.com

MasterSeal HLM 5000 is a one-component, moisture-curing, bitumen-modified polyurethane elastomeric waterproofing membrane for exterior below-grade or between-slab applications. It is available in four grades: MasterSeal HLM 5000 SL (self-leveling/squeegee) MasterSeal HLM 5000 S (spray) MasterSeal HLM 5000 T (trowel) MasterSeal HLM 5000 R (roller)

Related Documents:

MasterSeal HLM 5000 SL, HLM 5000 S y HLM 5000 R: cubetas de 18.95 L (5 gal) y tambores de 208 L (55 gal) disponible por pedido MasterSeal HLM 5000 T: cubetas de 18.95 L (5 gal) MasterSeal 995 (Sonoshield Reinforcing Fabric): rollos de 91 por 0.9 m (300 ft

MasterSeal HLM 5000 STORAGE AND SHELF LIFE Store in unopened containers in clean, dry conditions at 4 to 27 C. During storage, an easily removed skin of MasterSeal HLM 5000 may form, which does not affect performance of the product. MasterSeal HLM 5000 has a shelf life of 12 months for pails. VOC CONTENT - MasterSeal HLM 5000 SL: 183 g/L

MasterSeal HLM 5000 Màng chống thấm đàn hồi, dạng lỏng, thi công nguội FORMERLY SONOSHIELD HLM 5000 MÔ TẢ MasterSeal HLM 5000 là lớp phủ một thành phần gốc polyurethane, v ật liệu đóng rắn bằng cách

07 14 00 7 Impermeabilizante de aplicación líquida MasterSeal HLM 5000 Sistema líquido de membrana impermeabilizante elastomérica aplicado en frío SONOSHIELD HLM 5000 CARACTERÍSTICAS Y BENEFICIOS MasterSeal y HLM 5000 R: cubetas de Disponible como sistema de recubrimiento estándar

1,8kg/m2 de MasterSeal 6100 FX en polvo). poseedor final del producto. Rendimiento saco 15kg: 8,3m2 Consumo Rendimiento 10kg Reducción consumo MasterSeal 550 4,5kg/m2 2,20m2 - MasterSeal 560 2,5kg/m2 5,00m2 45% MasterSeal 6100 FX 1,8kg/m2 5,55m2 60% Estos consumos son teóricos y dependen de la rugosidad

products e.g. MasterSeal 590, MasterSeal P 385 Part D or MasterEmaco S 5440 RS Iron / steel: Should be sand blasted to a SA 2½ finish prior to application of the product. No primer coat is needed for application of MasterSeal M 790 on steel. Substrate temperature

MasterSeal systems can not be applied in situations of water coming in counter pressure. In this case it is necessary to provide drainage and then block the coming water with the fast setting MasterSeal 590 mortar. In the event that you encounter any patches still wet, apply one or two coats of MasterSeal P 385 after 48-72 hours

ARCHAEOLOGICAL ILLUSTRATION 8 IMAGE GALLERY - SCRAN images to draw IMAGE GALLERY - illustrations from the 19 th century to the present day IMAGE GALLERY - illustrations from 19th century to the present day STONE WORK Stones with incised crosses, St N inian’s Cave, Wigtownshire. Illustration from Proceedings of the Society of Antiquaries of Scotland (1884-85), Figs. 2 and 3, p84 .