Product Data SheetEdition 02/03/2015Identification no:02 02 05 01 003 0 000004Sika AnchorFix -3001Sika AnchorFix -3001ConstructionHigh-performance, professional epoxy anchoring adhesiveProductDescriptionSolvent-free, thixotropic, two part, epoxy resin-based, high performance anchoringadhesive for threaded rods and reinforcing bars in both cracked and un-crackedconcrete.UsesFor the fixing of non-expanding anchors in the following:Structural work: Rebar / steel reinforcement anchoring in new and refurbishment works Threaded rods Bolts and special fastening / fixing systemsMetalwork, carpentry: Fixing of handrails, balustrades and supports Fixing of railings Fixing of window and door framesIn the following substrates: Concrete (cracked and un-cracked) Hard natural and reconstituted stone Solid rock Hollow and solid masonry WoodCharacteristics /Advantages Long Open TimeCan be used in damp concreteHigh load capacityETA Approval availableICC-ES Approval availableDrinking Water certifiedLEED Attestation availableFire resistance test report availableSeismic testing availableStyrene-freeExcellent adhesion to the substrateShrinkage-free hardeningStandard guns can be used (with the 250ml cartridge)Low odourLow wastage1Sika AnchorFix -30011/8

TestsApproval / StandardsApprovals:European Technical Approval ETAG 001 Part 5 Option 1Galvanised anchor & stainless steel anchors M10 to M30 and rebars Ø10 to Ø 32mm for cracked & non-cracked concrete including seismic factorEC Cert. 1020-CPR-090-032737ETA-14 / 0157European Technical Approval ETAG 001 Part 5 TR023Post installed rebar connections of the sizes Ø8 to Ø 40 mmEC Cert. 1020-CPD-032640ETA-14 / 0368Fire resistance:Test report from the CSTB instituteREPORT No 26054326/B on Sika AnchorFix -3001 injection systems in conjunctionwith concrete reinforcing bar (Ø 8 to 40mm) and subjectedto fire exposureIAPMO Evaluation Report31Galvanised anchor & stainless steel anchors M10 to M30( /8 to 1 /4 inch)Rebars T10 to T32(No. 3 to No. 10)Testing according to AC 308 standards.Report Number: 0292ICC ES Report31Galvanised anchor & stainless steel anchors M10 to M30( /8 to 1 /4 inch)Rebars T10 to T32(No. 3 to No. 10)Testing according to AC 308 standards.Report Number: ESR-36082Sika AnchorFix -30012/8

Drinking Water Approval:Drinking Water System Components NSF / A NSI 61K-8319LEED Attestation:Test report from eurofinsREPORT No G23222 43Sika AnchorFix -30013/8

Product DataFormColoursPart A:Part B:Part A B mixed:Packaging250 ml standard cartridge, 12 per box.Pallet: 60 boxes with 12 cartridges.off-whitedark grey / blackgrey400 ml side by side cartridge, 12 per box.Pallet: 50 boxes with 12 cartridges.600 ml side by side cartridge, 12 per box.Pallet: 34 boxes with 12 cartridges.1500 ml side by side cartridge, 5 per box.Pallet: 50 boxes with 5 cartridges.StorageStorage Conditions /Shelf-Life24 months from date of production if stored properly in original unopened, sealedand undamaged packaging in cool and dry conditions at temperatures between 5 C and 20 C. Protect from direct sunlight. All Sika AnchorFix -3001 cartridges have the expiry date printed on the label.Technical DataDensityPart A: 1.2 kg/lPart B: 1.8 kg/l 1.70 kg/l (part A B mixed)Curing SpeedTemperatureOpen Time TgelCuring Time Tcur 40 C3 minutes3 hours 35 C - 40 C4 minutes4 hours 30 C - 35 C6 minutes5 hours 25 C - 30 C8 minutes6 hours 22 C - 25 C11 minutes7 hours 15 C - 22 C15 minutes8 hours 10 C - 15 C20 minutes12 hours 4 C - 9 C-*24 hours*Min. cartridge temperature 10 CSag FlowNon-sag, even overhead.Layer Thickness 7 mm max.Mechanical / PhysicalPropertiesCompressive StrengthFlexural Strength2(According to ASTM D695)2(According to ASTM D790)2 85 N/mm (7days, 20 C) 45 N/mm (7days, 20 C)Tensile Strength 23 N/mm (7days, 20 C)(According to ASTM D638)E-ModulusCompressive:2 5’000 N/mm(According to ASTM D695)Tensile:2 5’500 N/mm(According to ASTM D638)DesignFor design details, please refer to the separate documentation provided: “TechnicalDocumentation Sika AnchorFix -3001” Ref: 870 43 104Sika AnchorFix -30014/8

ResistanceThermal Resistance-40 C to 43 C 43 C long termSystemInformationApplication DetailsHole ØMaterial consumption per anchor in mlThread ØConsumption / DosageTheoretical volume [ml]@ a certain hole depth he indicated filling quantities are calculated without wastage. Wastage 10 - 50%.The filled quantity can be monitored during injection with the help of the scaleon the catridge label.Substrate QualityMortar and concrete must be older than 28 days.Substrate strength (concrete, masonry, natural stone) must be verified.Pull-out tests must be carried out if the substrate strength is unknown.The anchor hole must always be clean, dry, free from oil and grease, etc.Loose particles must be removed from the holes.Threaded rods and rebars have to be cleaned thoroughly from any oil, grease orany other substances and particles such as dirt etc.5Sika AnchorFix -30015/8

ApplicationConditions /LimitationsSubstrate Temperature 4 C min. / 40 C max.Ambient Temperature 4 C min. / 40 C max.Material TemperatureSika AnchorFix -3001 must be used at a temperature of between 10 C and 30 C.Dew PointSubstrate temperature during application must be at least 3 C above dew point toavoid condensation. ApplicationInstructionsMixingPart A : part B 1 : 1 by volumeMixing ToolsGetting the cartridge ready:250 ml400 / 600ml / 1500mlUnscrew and remove the cap250 Cartridge:- Pull out the plug400 / 600 &1500ml Cartridges:- Pull out the red plugScrew on the static mixerPlace the cartridge into the gun andstart applicationWhen work is interrupted the static mixer can remain on the cartridge after the gunpressure has been relieved. If the resin has hardened in the nozzle when work isresumed, a new nozzle must be attached.6Sika AnchorFix -30016/8

Application Method /ToolsAnchors in solid masonry/concrete:Drilling of hole with an electric drill to the diameter and depthrequired. Drill hole diameter must be in accordance with anchorsize.The drill hole must be cleaned with by compressed air, using an airlance, starting from the bottom of the hole. (at least twice) untilreturn air stream is free of noticed dust. Oil-free compressors shallbe used, minimum pressure:6 Bar (90 psi)The drill hole must be thoroughly cleaned with the special steelbrush (brush at least twice). The diameter of the brush must belarger than the diameter of the drill hole.The drill hole must be then be cleaned again by compressed air,using an air lance, starting from the bottom of the hole. (at leasttwice again) until return air stream is free of noticed dust. Oil-freecompressors shall be used, minimum pressure:6 Bar (90 psi)The drill hole must be thoroughly cleaned with the special steelbrush again (brush at least twice again). The diameter of the brushmust be larger than the diameter of the drill hole.The drill hole must then be finally cleaned yet again bycompressed air, using an air lance, starting from the bottom of thehole. (at least twice) until return air stream is free of noticed dust.Oil-free compressors shall be used, minimum pressure:6 Bar (90psi)Pump approx. twice until both parts come out uniformly. Do not usethis material. Release the gun pressure and clean the cartridgeopening with a cloth.Inject the adhesive into the hole, starting from the bottom, whileslowly drawing back the static mixer. In any case avoid entrappingair. For deep holes extension tubing can be used.Insert the anchor with a rotary motion into the filled drill hole. Someadhesive must come out of the hole.Important: the anchor must be placed within the open time.During the resin hardening time the anchor must not be moved or loaded. Wash tools immediately with Sika Colma Cleaner.Wash hands and skin thoroughly with warm soap water.Important Note: Anchors in hollow blocks: Do use Sika AnchorFix -1 for hollow blocks.Cleaning of Tools Clean all tools and application equipment with Sika Colma Cleaner immediatelyafter use. Hardened / cured material can only be removed mechanically.7Sika AnchorFix -30017/8

ConstructionValue BaseAll technical data stated in this Product Data Sheet are based on laboratory tests.Actual measured data may vary due to circumstances beyond our control.Local RestrictionsPlease note that as a result of specific local regulations the performance of thisproduct may vary from country to country. Please consult the local Product DataSheet for the exact description of the application fields.Health and SafetyInformationFor information and advice on the safe handling, storage and disposal of chemicalproducts, users shall refer to the most recent Material Safety Data Sheet containingphysical, ecological, toxicological and other safety-related data.Legal NotesThe information, and, in particular, the recommendations relating to the applicationand end-use of Sika products, are given in good faith based on Sika's currentknowledge and experience of the products when properly stored, handled andapplied under normal conditions in accordance with Sika’s recommendations. Inpractice, the differences in materials, substrates and actual site conditions are suchthat no warranty in respect of merchantability or of fitness for a particular purpose,nor any liability arising out of any legal relationship whatsoever, can be inferredeither from this information, or from any written recommendations, or from any otheradvice offered. The user of the product must test the product’s suitability for theintended application and purpose. Sika reserves the right to change the propertiesof its products. The proprietary rights of third parties must be observed. All ordersare accepted subject to our current terms of sale and delivery. Users must alwaysrefer to the most recent issue of the local Product Data Sheet for the productconcerned, copies of which will be supplied on request.It may be necessary to adapt the above disclaimer to specific local laws andregulations. Any changes to this disclaimer may only be implemented with permission of Sika Corporate Legal in Baar.Sika Services AGTüffenwies 16CH-8048 ZurichSwitzerlandPhone 41 44 436 40 40Telefax 41 44 436 46 86www.sika.com8Sika AnchorFix -30018/8

Sika AnchorFix -3001 1 1/8 Construction Sika AnchorFix -3001 Sika AnchorFix -3001 . High-performance, professional epoxy anchoring adhesive. Product Description . Solvent -free, thixotropic, two part, epoxy resin based, high performance anchoring adhesive for threaded rods and reinforcing bars in both cracked and un-cracked concrete. Uses

Related Documents:

Sika AnchorFix -3001 March 2021, Version 04.01 020205010030000004 PRODUCT DATA SHEET Sika AnchorFix -3001 Epoxy high performance chemical anchoring material DESCRIPTION Sika AnchorFix -3001 is an epoxy resin based, 2-part, .

Índice 5 Manual de productos Sika Índice Alfabético Sika Estuka Acrílico M / Sika Estuka Acrílico F 392 Sika Estuka E 394 Sika Estuka I / Sika Estuka I-Base 396 Sika FerroGard -903 150 Sika Fiber 99 Sika Fiber CHO65/35 NB 98 Sika Fiber Xorex 100 SikaFix HH 331 SikaFix HH LV 328 Sikaflex -1a 289 Sikaflex -1c SL 264 Sikaflex -2c SL 266 Sikaflex -15 LM SL 268 .

Sika AnchorFix -1 Enero 2019, Versión 02.01 020205010010000001 HOJA DE DATOS DEL PRODUCTO Sika AnchorFix -1 Adhesivo de curado rápido para anclajes químicos. DESCRIPCION DEL PRODUCTO Sika AnchorFix-1 es un adhesivo para anclajes, de dos componentes (10:1), elaborado a base de resina de poliéster en éster de metacrilato, libre de .

Sika AnchorFix -1 N July 2020, Version 01.01 020205010010000016 PRODUCT DATA SHEET Sika AnchorFix -1 N FAST CURING ANCHORING ADHESIVE DESCRIPTION Solvent and styrene free based, two-component poly-ester anchoring adhesive. USES Sika AnchorFix -1 N may only be used by experienced professionals. As a fast curing anchoring adhesive for all .

Sika AnchorFix -2 1 Fisa tehnica de produs Editia 04/09/2013 Numar de identificare: 02 04 02 06 001 0 000020 Sika AnchorFix -2 Sika AnchorFix 2 Adeziv de inalta performanta pentru ancorari Descrierea produsului Adeziv bi-component pentru ancorari, pe baza de epoxi-acrilat, fara solvent si stiren

(a) Sika FerroGard 903 Friazinc R. (b) Sika Top Armatec 108. (c) Sika Top Armatec 110 Epo Cern. MICROCONCRETE (a) Sika Rep Microcrete 1/2. (b) Sika Rep Microcrete 3 UW (c) Sika Rep Microcrete 4. REPAIR MORTAR / POLYMERS (a) Sika Top 77. (b) Sika Top 122. (c) Sika Top 122HS. POURABLE CEMENTITIOUS GROUTS (a) Sika

Sika AnchorFix -1 Author: Sika Belgium nv, Venecoweg 37, 9810 Nazareth, Belgium, www.sika.be Subject: TECHNISCHE FICHE Keywords: Sika AnchorFix -1 020205010010000001 SNEL UITHARDENDE VERANKERINGSLIJM

TCIA (ASC A300) (Tree Care Industry Association) Revision BSR A300 Part 2-201x, Tree, Shrub, and Other Woody Plant Management - Standard Practices (Soil Management a. Assessment, b. Modification, c. Fertilization, and d. Drainage) (revision of ANSI A300 Part 2-2011) A300 (Part 2) Soil Management standards are performance standards for