PLUMBING GENERAL NOTESContract Requirements1.All Plumbing Work Shall Be Prepared In Strict Accordance With The Specifications And With TheCurrently Adopted Edition Of The Prevailing State Code As Well As All Local Regulations That MayApply. In Case Of Conflict Between The Contract Documents And A Governing Code Or OrdinanceThe More Stringent Standard Shall Apply.2. Contractor Shall Provide All Required Labor, Materials, Equipment, And Services Necessary ToAccomplish A Safe And Complete Installation Of The Systems Indicated On The Drawings. AllMaterial And Methods Shall Be In Strict Accordance With All Authority Having JurisdictionRequirements. Work Shall Be Performed In A Neat And Workmanlike Manner.3. Contractor Shall Obtain All Necessary Permits, Licenses, And Certificates Required By TheAuthority Having Jurisdiction. This Shall Include, But Is Not Limited To All Required BuildingDepartment Filing, Inspections, And Final Closeout Of Permits.4. The Scope Of Work As Outlined In These Documents Ends At A Distance Of 5 Feet Outside TheBuilding Wall. Coordinate Connection With Civil Engineer And Local Utility Provider.5. The Contractor Shall Furnish A Written Guarantee To Replace Or Repair Promptly And AssumeResponsibility For All Expenses Incurred For Any Workmanship And Equipment In Which DefectsDevelop Within One Year From The Date Of Acceptance By Owner, This Work Shall Be Done AsDirected By The Owner. The Contractor Shall Incur All Expenses That Result From Such Work.6. Contractor Shall Visit The Site Prior To Submitting A Bid To Verify Existing Conditions And ConfirmSizes And Locations Of Existing Services.PLUMBING GENERAL NOTESWater Hammer Arrestors. All Access Panels Shall Be Provided And Installed By The GeneralContractor. Plumbing Contractor Shall Be Responsible For Their Location.Sanitary / Storm Systems1. No PVC Or ABS Piping Shall Be Used In Any Above Grade Plumbing Installations.2. Cleanouts In Horizontal Drainage Lines Shall Be Spaced At Intervals Not To Exceed The Following:A.B.C.2‐1/2" Or Less: 25 Feet3" and 4":50 FeetMore Than 4": 85 Feet3. Install All Required Cleanouts To Clear Equipment And Fixtures. Cleanouts Shall Not Be Installed InElectrical Closets, IT Rooms, Or Any Similar Critical Or Water Sensitive Space.4. Sanitary Piping 3” And Greater Shall Have A Minimum Slope Of 1/8 Inch Per Foot. Sanitary PipingLess Than 3” Shall Have A Minimum Slope Of 1/4 Inch Per Foot.5. Fixture Vent And Branch Vent Piping Shall Be Installed Free Of Sags And Drops And Be SlopedToward The Connection To The Sanitary Drainage System. All Fixtures Shall Be Vented InAccordance With Governing State And Local Plumbing Code.6. All Horizontal Storm Drainage Piping Shall Be Insulated To Prevent Condensation On The Pipes.Insulation Shall Extend Vertically To The Underside Of The Drain Body.7. Provide All As‐Built Drawings To GC To Verify Completion Of Work And For Owner's Record.Natural Gas SystemsCoordination1. Existing Site Utility Connections, Invert Elevations, And Locations Shall Be Verified Prior ToBeginning Installation.2. Materials Approved By The Architect Or Engineer To Be Stored On Site Shall Be Stored In AnOwner Designated Location. Off Site Storage Must Be Arranged For Materials And Equipment NotSuitable For On Site Storage Or Items Not Applicable To The Current System Installation.General Requirements1. Natural Gas Piping 2‐1/2” And Greater Shall Be Schedule 40 Welded Pipe AndFittings. Piping 2” And Smaller Shall Be Schedule 40 Threaded Pipe And Fittings.2. All Natural Gas Piping Installed Outdoors Or In Corrosive Environments Shall Be Protected With AnApproved Corrosion Resistant, UV Resistant Enamel Coating Or Wrapping.3. All Corrugated Flexible Natural Gas Connections Shall Be Properly Grounded.3. At The End Of Each Work Day The Contractor Shall Leave The Job Site In A Neat Condition AndRemove All Construction Debris From The Site.4. All Plumbing Work Shall Be Coordinated With All Other Trades Before Proceeding With TheInstallation. No Changes Are To Be Made In Plumbing Layout Without Written Permission by TheArchitect or Engineer.5. Drawings Are Diagrammatic As Shown. Exact Routing And Arrangements Of Systems Shall BeCoordinated With All Other Trades, The Structural Drawings, Architectural Drawings, And AllExisting Field Conditions.6. Exact Dimensions And Locations Of Plumbing Fixture Rough‐In Must Be Coordinated With TheArchitect And General Contractor.4. All Natural Gas Piping Shall Be Pressure Tested And Leak Tested With Approved Non‐CorrosiveLeak‐Detecting Fluid Or Other Approved Leak‐Detection Method Prior To System Startup.5. Kitchen Installations Shall Include A Natural Gas Shut Off Valve Wired To Emergency Push ButtonShut Off Switches At All Paths Of Egress. Shut Off Valve Shall Be For Natural Gas Supply ToKitchen.Installation Requirements1. Install Sediment Traps (Dirt Or Drip Legs) Prior To The Gas Shutoff Valve On All Connections ToGas Fired Equipment.2. Natural Gas Piping Shall Not Be Installed In Or Through Return Air Plenums, Supply Or ExhaustDucts, Clothes Chutes, Chimneys, Or Elevator Shafts.General Installation1.All Exposed Piping Penetrations Through Walls, Floors, And Ceilings Shall Be Sealed WithApproved Fire Proofing Method and Escutcheons By Plumbing Contractor.2. Provide And Install Water Tight Piping Sleeves And Seal Systems At Exterior Concrete Walls AndSlabs On Grade For Service Piping Entries Into Building. Provide For Additional Waterproofing AtExterior Of POEs, Surrounding Piping / Sleeves As Necessarily With Approved Product.3. Whenever Possible Gas Piping Shall Not Be Installed In Concealed Locations. If Installation InConcealed Locations Cannot Be Avoided, Piping Shall Not Have Unions Or Fittings Unless FittingsAre Listed For Use In Concealed Locations.4. Piping Installed Under The Building Slab Shall Be Installed In An Approved Conduit Or SleeveSystem. The Conduit Must Be Vented At Both Ends And Terminate In An Occupiable Portion OfThe Building At A Minimum Of 2 Inches Above The Finished Floor.This Drawing Is The Property Of DLB Associates Consulting Engineers, PC. It Was Prepared Exclusively For This Particular Project And Is Limited To This Project Only. Unauthorized Reproduction Or Other Use Of These Drawings Or Ideas Is Prohibited.3. No Piping Shall Be Run Exposed In Finished Areas Unless Specifically Stated Otherwise In TheseDocuments.4. Provide Dielectric Fittings, Couplings, Or Spacers Whenever Dissimilar Materials Are Joined OrOtherwise Come Into Contact With Each Other.5. Where Overhead Construction Does Not Permit Fastening Of Supports The Contractor ShallProvide Supplementary Steel Required For Supporting Piping Materials.6. Any Piping Exposed To Freezing Conditions Shall Be Insulated And Heat Traced, This Includes AnySanitary Drainage Piping And Traps Installed In Unheated Spaces. Heat Traced To Be Installed ByPlumbing Contractor And Coordinated With Electrical Contractor For Service.7. For Water and Gas Piping: Expansion Loops Or Fittings Shall Be Provided At All Building ExpansionJoints And For Every 100 Feet Of Straight Piping Run. Provide Anchor Points And Restraints AsRequired By Manufacturer Installation Guidelines.Plumbing Fixtures & Equipment1.All Fixtures Shall Be Provided With Standard Trap And Cleanout.2. All Plumbing Fixture Flow Rates Shall Meet Minimum Flow Requirements As Outlined ByGoverning Plumbing Code And Local Jurisdiction Amendments.3. Federal Lead Free Legislation Effective January 4, 2014 Mandates That The Wetted Surface OfEvery Pipe, Fixture, And Fitting Sold Or Installed In Potable Water Applications Shall Not ContainMore Than 0.25% Lead By Weight. All Products Submitted Shall Be Certified Lead‐Free.4. Trap Primers Shall Be Furnished For All Drains Not Receiving Continuous Discharge. WherePractical, Flow Type Trap Primers Shall Be Installed On The Cold Water Supply To Lavatory Sinks.Electronic Trap Primers Shall Be Used In All Other Locations. Differential Pressure Trap PrimersAre Not Permitted For Use Under Any Circumstances.Domestic Water Systems1.All Work Shall Be Properly Tested, Balanced And Cleaned And Disinfected.2. Completely Insulate All Water Piping Except Where Exposed To Fixtures With Fiberglass InsulationWith Non‐Combustible UL Rated Vapor Barrier Or Closed Cell Flexible Insulation Equal ToArmaflex II. Breaks In Insulation At Hangers Will Not Be Acceptable.3. Provide Shut‐Off Valves On Hot And Cold Water Supply Pipes At Each Fixture, At Each BranchTake‐Off, And At All Connections To Water Heaters And Plumbing Equipment.4. At Each Hot Water Return Piping Connection To The Hot Water Supply Piping The Contractor ShallFurnish And Install Isolation, Balancing And Check Valves. Balance to 1 GPM Unless OtherwiseNoted.5. Provide Bellows Type Water Hammer Arrestors At Each Flush Valve Or Bank Of Flush Valves,Dishwashers, And All Fast Closing Valves. Where Installation Is Not Accessible CoordinateLocation Of Access Panels With The Architect.6. Access Panels Shall Be Provided As Necessary To Allow For Access To Valves, Trap Primers AndNEW CLUB HOUSEASH BROOK GOLF COURSEdlb associates1210 RARITAN RD, SCOTCH PLAINS, NJ 07076CONSULTING ENGINEERS, P.C.One Penn Plaza, Suite 2601, New York, NY 10119BID SETQuestions For dlb Call:DLB Project ID: 12285Rob JankowskiPhone: (646) 381‐6721NETTAARCHITECTSARCHITECTURE - PLANNING - INTERIOR DESIGN1084 ROUTE 22 WEST, MOUNTAINSIDE, NEW JERSEY 07092TEL: 973.379.0006FAX: 973-379-1061CERTIFICATE OF AUTHORIZATION AC-438Last Saved: N:\12\122\12285\12285P‐001.dwg, 2/21/17 at 12:03 PM By CNASH ‐ Last Printed: 2/21/17 at 4:41 PM By Snyder, Cara NashPLUMBING INFORMATION SHEETConfidential and Proprietary / DLB Associates 2017

3" RD(884 SQ FT)4" RD(2733 SQ FT)4" OVERFLOW RD3" OVERFLOW RDKITCHEN1174" VTR4"4"3"WOMEN'S / JANITOR'S CLOSET / MEN'S TOILET113 / 114 / 115BAR / "SKFSSTFSFDTR6"6"4" FRESH AIR INTAKECO4" FRESH AIR INTAKE4" GW HOUSETRAP IN CEILINGTRFSSKSKFSFSFDCO4"S6" STORM OVERFLOW,SPILL TO 2"1‐1/2"1‐1/2"2"ST2"ST2"2"2"FDFD CODP CODP CODP1‐1/2"2"LVCODP CODPFD1‐1/2"2"4"4"5"4"COS4"S4"COCOCO2"2"2"MSCODP WC4"COS2"1‐1/2"5" 5"1‐1/2"2"1‐1/2"2"WOMEN'S / MEN'S TOILET105 / 106FD CODPCODPFD2"2"FDFD CODP1‐1/2"2"LVURLV1‐1/2"LV2"2"2"FDCODP 1/2"2"2"2"SKFS CODPFSGICODP CODPGREASEINTERCEPTOR4"4"4"126 DFUCONTINUATION BYPLUMBING CONTRACTOR4"153 DFU4"S4"S4"S4"4"4"CONTINUATION BYPLUMBING CONTRACTORSANITARY HOUSETRAP IN PITNEW SANITARY SERVICEFROM STREET MAIN BY CIVIL6"TOILET RML20FIRE SPK ROOML136"STCONTINUATION BYPLUMBING CONTRACTORJAN CLOSETL21STKITCH. STORL17STAFF LOCKER ROOMSL04 & L05TURNSTANDL016"STORM HOUSETRAP IN PITNEW STORM SERVICE FROMSTREET MAIN BY CIVIL88 MBH1,200 MBH225 MBH1‐1/4"2‐1/2"G350 MBH2‐1/2"1‐1/2"2"GG1‐1/2"2"WOMEN'S / MEN'S TOILET105 / 106HWRHWCWHWCW1‐1/2"2‐1/2"GHWRHWCWGBAR / LOUNGE112WOMEN'S / JANITOR'S CLOSET / MEN'S TOILET113 / 114 / 115KITCHEN117GGGGGGGGFGDrawing: P‐002Detail: 01350 MBH2‐1/2"2‐1/2"Scale:NTS1‐1/2"2‐1/2"350 MBH1‐1/2"250 MBHWCWCLAVLAVLAVLAVLAVLAVMSB11B12KITCHEN EQUIPMENT1" HWR2‐1/2" HW2" CWWCWCLAVLAVLAVCWHWHWRGLAVWCWCUR3"(1970 MBH)1‐1/2"LAVWC3/4"400 MBHFUTUREFIREPITHBLAVLAVGGCWHWHWR1‐1/2"400 MBHFUTUREFIREPITCAP GAS PIPE ABOVE GROUNDFOR FUTURE FIRE PITSF350 "1/2"1/2"1/2"1/2"1/2"1/2"1‐1/2"WC1‐1/2"3"(1970 /2"G1‐1/2"3/4"1/2"1/2"LAV1‐1/2"2"(500 MBH)1‐1/2"3.5" Natural Gas SupplyTotal Load: 5,489 MBHPressure Drop: 0.5 IN.W.C.Developed Length: 200 FtSchedule 40 Metallic PipeDesign Pressure: 0.5 PSISpecific Gravity: 0.60Table 402.4(1) IFGC 2009GCWHWHWRG1‐1/2"3‐1/2"3‐1/2"(3376 MBH)UR1‐1/2"1‐1/2"2‐1/2" HW2" 2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"2"(906 MBH)2"3‐1/2"G(5489 MBH)This Drawing Is The Property Of DLB Associates Consulting Engineers, PC. It Was Prepared Exclusively For This Particular Project And Is Limited To This Project Only. Unauthorized Reproduction Or Other Use Of These Drawings Or Ideas Is Prohibited.SANITARY & STORM RISER DIAGRAMTS01GAS PRESSURE REDUCER250MBHHIGH PRESSUREGAS SERVICE120MBH250MBHGCWCONTINUATION BYPLUMBING CONTRACTORTOILET ROOML203"180 WSFUHOT WATER HEATER ROOML14STAFF MEN'SLOCKER ROOM L05STAFF MEN'SLOCKER ROOM L04MECH ROOML08TURNSTANDL01MAIN BUILDING DOMESTICWATER CONTROL VALVENEW DOMESTIC WATER SERVICEFROM STREET MAIN BY CIVILWATER & GAS RISER DIAGRAMScale:NTSDrawing: P‐002Detail: 02NEW CLUB HOUSEASH BROOK GOLF COURSEdlb associates1210 RARITAN RD, SCOTCH PLAINS, NJ 07076CONSULTING ENGINEERS, P.C.One Penn Plaza, Suite 2601, New York, NY 10119BID SETQuestions For dlb Call:DLB Project ID: 12285Rob JankowskiPhone: (646) 381‐6721NETTAARCHITECTSARCHITECTURE - PLANNING - INTERIOR DESIGN1084 ROUTE 22 WEST, MOUNTAINSIDE, NEW JERSEY 07092TEL: 973.379.0006FAX: 973-379-1061CERTIFICATE OF AUTHORIZATION AC-438Last Saved: N:\12\122\12285\12285P‐002.dwg, 2/21/17 at 12:03 PM By CNASH ‐ Last Printed: 2/21/17 at 4:41 PM By Snyder, Cara NashPLUMBING RISER DIAGRAMSConfidential and Proprietary / DLB Associates 2017

100 GAL HWH GASFD1CODPCODPFOR CONTINUATION, SEEDETAIL 02 ON THIS SHEET7BFOR CONTINUATION, SEEDETAIL 02 ON THIS SHEETLIVICYBMLUYPGBIN1‐1/2" V RISECODP1‐1/2" V RISESTB1FD66" STSTBLIVICY1FD1STORM HOUSETRAP UNDER SLAB4" TO SANITARY SEWERFD1MLUPYGBINSANITARYHOUSE TRAPUNDER SLAB6" STST1(3,617 SQ FT)4" UP TO FAITST SFDFD2" V RISECODPFDFDFD115" ST OVERFLOW RISE UP 55" ST RISE UP4" SAN UP TO CEILING3" V RISE1‐1/2" V RISE 111CODP1‐1/2" V RISECODPFD1FSFSCODPFDCODPFDCODP1‐1/2" V RISE 111‐1/2" V RISEUNDERCOUNTERCODPGIFOR CONTINUATION,SEE DETAIL 01 ONTHIS SHEET4" GW UPTO CEILINGFSCODPGISKBYMHGBINUMPLBYFOR CONTINUATION, SEEDETAIL 02 ON THIS SHEETILCIVThis Drawing Is The Property Of DLB Associates Consulting Engineers, PC. It Was Prepared Exclusively For This Particular Project And Is Limited To This Project Only. Unauthorized Reproduction Or Other Use Of These Drawings Or Ideas Is Prohibited.CODPCODPLOWER LEVELPARTIAL SYMBOLS & ptionSanitary Piping Below FloorCODPCleanout Deck PlateVent PipingDNDownPipe Up Through Floor Above OrThrough Section Cut LineFAIFresh Air IntakeFDFloor DrainFSFloor SinkGIGrease IntercepterGWGrease WasteMHManholeSANSanitarySTStormVVentPipe Drop / Offset DownCODPCleanout Deck PlateFloor DrainScale:1/8" 1'‐0"2' 4'8'KEY NOTES1. It Is The Responsibility Of The Plumbing Contractor To Verify All Equipment Rough‐Ins With TheAppropriate Supplier And To Determine The Most Feasible And Economical Location To Install Piping AndValve Services.1.1‐1/2" Vent Riser.2.Not Used.2. Pipes Passing Under Or Through Any Walls, Including Foundation Walls Shall Be Installed Through PipeSleeves One Size Larger Than Pipe. Seal Around Pipe.3.Not Used.4.Not Used.5.4" Up To Secondary (Overflow) Roof Drain.6.6" Storm Pipe At Ceiling Of This Level From Overflow Roof Drain.7.Overflow Storm Drain Elbow Down To Spill On Pavement.4. Refer To Architectural Drawings For Exact Locations And Elevations Of All Plumbing Fixtures, Drains AndEquipment. Provide Water Hammer Arrestors With Access Doors Adjacent To All Water HammerArrestors. Provide Shut‐Off Valves At Each Fixture On Water Supply Pipes Hot And Cold.1,Drawing: P‐101Detail: 01GENERAL NOTES3. All Pipe Penetrations Of Fire And/ Or Smoke Rated Assemblies Shall Be Fire Stopped As Required ToRestore Assembly To Original Integrity.(SYMBOLS16'N2, ETC.)TURNSTAND PART PLANScale:1/4" 1'‐0"1' 2'4'8'NDrawing: P‐101Detail: 02KEY PLANROOFCLUBHOUSE5. Architect To Provide Clear Floor Space Accessibility Requirements For All Showers and ADA PlumbingFixtures.LOWER LEVEL6. Install Work So As To Be Readily Accessible For Operation, Maintenance, And Repair. Minor DeviationsFrom The Drawings May Be Made To Accomplish This Without Additional Cost To The Owner. ChangesWith Cost Impact Shall Not Be Made Without Approval.NKeyplanVertical Plan7. Provide All Necessary Piping Offsets And Changes In Direction Required To Complete The Installation.NEW CLUB HOUSEASH BROOK GOLF COURSEdlb associates1210 RARITAN RD, SCOTCH PLAINS, NJ 07076CONSULTING ENGINEERS, P.C.One Penn Plaza, Suite 2601, New York, NY 10119BID SETQuestions For dlb Call:DLB Project ID: 12285Rob JankowskiPhone: (646) 381‐6721NETTAARCHITECTSARCHITECTURE - PLANNING - INTERIOR DESIGN1084 ROUTE 22 WEST, MOUNTAINSIDE, NEW JERSEY 07092TEL: 973.379.0006FAX: 973-379-1061CERTIFICATE OF AUTHORIZATION AC-438Last Saved: N:\12\122\12285\12285P‐101.dwg, 2/21/17 at 12:02 PM By CNASH ‐ Last Printed: 2/21/17 at 4:42 PM By Snyder, Cara NashLOWER LEVEL - SANITARYConfidential and Proprietary / DLB Associates 2017

13"FDFOR CONTINUATION,SEE DETAIL 02 ON P‐103CO4" AT CEILING BELOW21I4"COCOCO4" SAN DN TO UNDER SLAB3"FD5 73" V UP & DN4"FA16FOR CONTINUATION, SEE DETAIL 01 ON P‐103114"13"FD3"FD1ST4"2This Drawing Is The Property Of DLB Associates Consulting Engineers, PC. It Was Prepared Exclusively For This Particular Project And Is Limited To This Project Only. Unauthorized Reproduction Or Other Use Of These Drawings Or Ideas Is Prohibited.89N, 03TIO P‐1AU NTIN 01 ONO ILR C TAFO E DESECO3GW4FAICLUBHOUSE LEVELPARTIAL SYMBOLS & ptionSanitary Piping Below FloorCOCleanoutVent PipingDNDownStorm PipingFAIFresh Air IntakePipe Up Through Floor Above OrThrough Section Cut LineFDFloor DrainGWGrease WasteVVentPipe Drop / Offset DownCOKEY PLAN1.1‐1/2" Vent Rise.2.2" Vent Rise.2. Pipes Passing Under Or Through Any Walls, Including Foundation Walls Shall Be Installed Through PipeSleeves One Size Larger Than Pipe. Seal Around Pipe.3.4" GW House Trap At Ceiling Below.4.4" GW Down To Below Slab.5.4" Up To Overflow Roof Drain & Down To Lower Level Ceiling.4. Refer To Architectural Drawings For Exact Locations And Elevations Of All Plumbing Fixtures, Drains AndEquipment. Provide Water Hammer Arrestors With Access Doors Adjacent To All Water HammerArrestors. Provide Shut‐Off Valves At Each Fixture On Water Supply Pipes Hot And Cold.6.Connect To 5" Storm Leader.7.Connect To 5" Overflow Storm Riser.5. Architect To Provide Clear Floor Space Accessibility Requirements For All Showers and ADA PlumbingFixtures.8.3" Up To Roof Drain.CLUBHOUSE9.3" Up To Overflow Roof Drain.LOWER LEVELROOFSanitary Clean OutFloor Drain16'1. It Is The Responsibility Of The Plumbing Contractor To Verify All Equipment Rough‐Ins With TheAppropriate Supplier And To Determine The Most Feasible And Economical Location To Install Piping AndValve Services.2, ETC.)8'Drawing: P‐102Detail: 01KEY NOTES1,2' 4'NGENERAL NOTES3. All Pipe Penetrations Of Fire And/ Or Smoke Rated Assemblies Shall Be Fire Stopped As Required ToRestore Assembly To Original Integrity.(SYMBOLSScale:1/8" 1'‐0"6. Install Work So As To Be Readily Accessible For Operation, Maintenance, And Repair. Minor DeviationsFrom The Drawings May Be Made To Accomplish This Without Additional Cost To The Owner. ChangesWith Cost Impact Shall Not Be Made Without Approval.NKeyplanVertical Plan7. Provide All Necessary Piping Offsets And Changes In Direction Required To Complete The Installation.NEW CLUB HOUSEASH BROOK GOLF COURSEdlb associates1210 RARITAN RD, SCOTCH PLAINS, NJ 07076CONSULTING ENGINEERS, P.C.One Penn Plaza, Suite 2601, New York, NY 10119BID SETQuestions For dlb Call:DLB Project ID: 12285Rob JankowskiPhone: (646) 381‐6721NETTAARCHITECTSARCHITECTURE - PLANNING - INTERIOR DESIGN1084 ROUTE 22 WEST, MOUNTAINSIDE, NEW JERSEY 07092TEL: 973.379.0006FAX: 973-379-1061CERTIFICATE OF AUTHORIZATION

Phone: dlb associates One Penn Plaza, Suite 2601, New York, NY 10119 CONSULTING ENGINEERS, P.C. (646) 381‐6721 BID SET NEW CLUB HOUSE ASH BROOK GOLF COURSE 1210 RARITAN RD, SCOTCH PLAINS, NJ 07076 PLUMBING INFORMATION SHEET PLUMBING GENERAL NOTES PLUMBING GENERAL NOTES Contract Requirements 1.

Related Documents:

Identify plumbing materials and ttings Identify plumbing pipe protection methods (i.e., re caulk, nail plates) Interpret and comply with general plumbing practices Interpret manufacturer's speci cations Testing of plumbing systems Identify plumbing terminology Identify plumbing symbols Joining Pipes and Fittings

Identify plumbing materials and fittings Identify plumbing pipe protection methods (i.e., fire caulk, nail plates) Interpret and comply with general plumbing practices Interpret manufacturer's specifications Testing of plumbing systems Identify plumbing terminology Identify plumbing symbols

Plumbing continued to supply materials to Pace Plumbing even thought Pace Plumbing failed to pay Peterson Plumbing for over six months (R. 1-2, 65-66). On August 13, 2008, after receiving notice of the mechanics1 liens, GCD sent Peterson Plumbing a written request to remove the wrongful liens because they were filed in a untimely manner(R. 1-2 .

Unit 1 of the textbook gives an introduction to plumbing and . its importance. Unit 2 focuses on the tools used in plumbing. It includes the various types of manual tools required for carrying out plumbing tasks. Unit 3 deals with the plumbing material and pipes used in plumbing. Unit 4 focuses on the measurement and symbols used in plumbing.

Exterior Sun Control Devices Hydraulic Elevators Common Work Results - Plumbing General Duty Valves for Plumbing Plumbing Insulation Facility Water Distribution Facility Sanitary and Vent Piping Plumbing Equipment Plumbing Fixtures Common Results for HVAC Testing, Adjusting, and Balancing

defects in materials or manufacturing of PEI, MWI, and PSEI ranges of plumbing fittings and Speedfit PEX Pipe manufactured by John Guest. John Guest plumbing products are for use with normal domestic plumbing

Plumbing Broward County Edition Loose-leaf Supplement Insert and maintain this instruction sheet in front of the Florida Building Code, 6thEdition (2017) –Plumbing. File removed pages for reference. Plumbing - Remove Old Pages Plumbing - Insert New Pages Chapter 3 - Page 15 - 16 &KDSWHU 6 3DJH 35 - 36 Chapter 6 - Page 37 - 38

The Highway Asset Management Policy and the Highway Asset Management Strategy have been developed to help us to take account of these challenges. The policy is designed to drive continuous improvement in the way we maintain our highway network to ensure that it continues to be safe serviceable and sustainable. It sets out the principles that will ensure we adopt and develop a strategic .