Riser Identification Program2015-2017Columbia Gas of Pennsylvania ColumbiaGasPA.com

What prompted identification of Field Assembled Risers? Polar Vortex a few years ago– Found multiple leaking risers on customer owned facilities– Identified the types of risers as Field AssembledColumbia Gas of Pennsylvania ColumbiaGasPA.com 2

Establishing a Plan How are we going to capture the Data? Who is going to perform the work? What is the timeframe to have all risers identified? What is the plan for remediation?Columbia Gas of Pennsylvania ColumbiaGasPA.com 3

How . Looked at our system and functionality– Other systems available to capture data– How can we have the data available to us?Other states were developing a program for leak inspection and other functionsA way to tie risers into an existing function–Service orders–Leak inspection–Inside inspectionsColumbia Gas of Pennsylvania ColumbiaGasPA.com 4

Who Who visits our meter sets on a consistent basis?–Service techs–Leak Inspectors–ContractorsWho has the knowledge or training to identify the risers?–Service techs–Leak Inspectors–ContractorsColumbia Gas of Pennsylvania ColumbiaGasPA.com 5

Timeframe Leak Inspection on CSLs are done on a 3 year cycle 2015 through 2017–By the end of 2017, every Riser will have been identified–Leak Inspectors identified each Riser while completing the CSL inspection–Pictures were taken of each RiserColumbia Gas of Pennsylvania ColumbiaGasPA.com 6

Remediation Company Owned Service Lines– Established a program to replace the identified Field Assembled Risers, as appropriate.Customer Owned Service Lines–Data is being gathered to establish a plan for replacement of Field Assembled Risers, asappropriate.–Some Service Lines are being replaced as part of Columbia’s accelerated main replacementprogram, per PUC approval in Docket No. 00072337.Columbia Gas of Pennsylvania ColumbiaGasPA.com 7

Training Booklets made to show examples of each riser–Distributed to Company personnel and Contractors–Discussed some minor differences to look for in some Riser typesColumbia Gas of Pennsylvania ColumbiaGasPA.com 8

PLASTIC RISERFIELD ASSEMBLEDCONTINENTALColumbia Gas of Pennsylvania ColumbiaGasPA.com 9

PLASTIC RISERSFIELD ASSEMBLEDNORMACColumbia Gas of Pennsylvania ColumbiaGasPA.com 10

PLASTIC RISERSFIELD ASSEMBLEDPERFECTION / PERMASERTColumbia Gas of Pennsylvania ColumbiaGasPA.com 11

PLASTIC RISERSFACTORY ASSEMBLEDAPPROVEDPERFECTION RETROFIT PC07 STAMP ON HEXNUT (3 sides) “FACTORYASSEMBLED” LABEL CRIMPED SHROUDOVER THREADEDSECTION PART # 71800 RISER CODE – EC10Columbia Gas of Pennsylvania ColumbiaGasPA.com 12

FREQUENTLY MISIDENTIFIED FIELDASSEMBLED RISERSNotice the differencesbetween The Normac andthe Rob Roy risers.NORMACColumbia Gas of Pennsylvania ColumbiaGasPA.com ROB ROY13

FREQUENTLY MISIDENTIFIEDFACTORY ASSEMBLED RISERSPerfection RiserECSI RisernoticechannelColumbia Gas of Pennsylvania ColumbiaGasPA.com 14

The Program NiFastColumbia Gas of Pennsylvania ColumbiaGasPA.com 15

The Program NiFastColumbia Gas of Pennsylvania ColumbiaGasPA.com 16

The Program NiFastColumbia Gas of Pennsylvania ColumbiaGasPA.com 17

The Program NiFast Data goes to a database where all the data is stored.Columbia Gas of Pennsylvania ColumbiaGasPA.com 18

The Benefits Pictures can be pulled for eachmeter to look at without a fieldvisit.A tech can pull a picture upfrom a previous survey for hardto find meters or properties. Farm taps may be easier to findfrom previous survey data. Knowledge of our system andareas for improvement. Data to be discussed in ourDIMP meetingsGPS coordinates can besnapped while onsite at themeter to help find meters in thefuture.Columbia Gas of Pennsylvania ColumbiaGasPA.com 19

Questions?Columbia Gas of Pennsylvania ColumbiaGasPA.com 20

Columbia Gas of Pennsylvania ColumbiaGasPA.com PLASTIC RISERS FACTORY ASSEMBLED PC07 STAMP ON HEX NUT (3 sides) “FACTORY ASSEMBLED” LABEL CRIMPED SHROUD OVER THREADED SECTION PART # 71800 RISER CODE – EC10 APPROVED PERFECTION RETROFIT 12

Related Documents:

General design rules for riser necks used in iron castings; a. general riser b. side riser for plates c. top round riser Risers and Riser Design . Mech 423 #2 2 Figure 5.10 (a) Castings with blind feeders, F2 is correctly vented but has mixed results on sections S3 . metal velocity and turbulence

S4 / S6 Riser Kits Installation 9329-66144-00 REV A 1 S4/S6 Riser Kit Installation This document provides instructions for inst alling Riser Kits in an Avid S4 or S6 c ontrol surface. Riser Ki ts raise modules whe n a better viewing and interaction angle is desi red. Riser Kits for S4 and S6 include 1- bay and 2-bay kits.

k. Riser clamps for bare cast iron pipe shall be Anvil Fig. 261 steel riser clamps. Locate under coupling or bell of pipe. l. Riser clamps for bare plastic pipe shall be Anvil Fig. 261 steel riser clamps. m. Riser clamps for bare stainless steel

the looped fire line to provide for isolation of the fire line. 5. fire sprinkler lines shall have a riser control piv for each individual riser. the piv's shall be located as close to the riser as practical. the riser control piv's may be eliminated when fd105 is used. fire sprinkler (fs) system riser (fd105) shall be shown on 6.

connected drilling riser. A typical drilling riser stack-up is shown in Figure 1. Waves cause vessel surge and sway motions which are then transferred to the top of the drilling riser. Additionally, there is direct hydrodynamic load on the riser from the waves. Vortex-induced vibration (VIV) is another source of riser motions.

Riser must be separated from the casting upon completion so the connection area must be as small as possible Figure 11-13 Schematic of a sand casting mold, showing a) an open-type top riser and b) a blind-type side riser. The side riser is a

Voile EONA 3 XS S M ML L Number of cells 38 38 38 38 38 Flat surface area (m²) 21,8 24 26,6 28,7 31 . Speedbar Split-hook Speedbar bar Inner bag Pocket with repair kit Riser hook-up loop Leading edge Trailing edge Stab A riser B riser C riser Brake handle Brake line Brake re

FIRE HYDRANTS and PARTS 78 M & H Fire Hydrant Repair Kit 10 78.82 788.20 79 M & H Fire Hydrant Riser 6" 2 200.85 401.70 80 M & H Fire Hydrant Riser 12" 4 237.35 949.40 81 M & H Fire Hydrant Riser 18" 2 255.64 511.28 82 M & H Fire Hydrant Riser - 24 " 1 273.91 273.91