Service InstructionsANX, SSX, ASX, GSX, DSXCondensing Units,ANZ, SSZ, ASZ, GSZ, DSZ, VSX, VSZ Split System Heat Pumpswith R-410A RefrigerantBlowers, Coils, & AccessoriesThis manual is to be used by qualified, professionally trained HVAC technicians only. Themanufacturer does not assume any responsibility for property damage or personal injury due toimproper service procedures or services performed by an unqualified person.Copyright 2006-2018 Goodman Manufacturing Company, L.P.RS6200006r88February 2018

Table of ContentsIMPORTANT INFORMATION . 2PRODUCT IDENTIFICATION - MODEL TREES . 4COILS . 6BLOWERS . 7AIR HANDLERS . 8LIGHT COMMERCIAL . 10PRODUCT IDENTIFICATION - CHARTS . 11LIGHT COMMERCIAL . 11IMPORTANT INFORMATIONSPLIT SYSTEM HEAT PUMPS . 12AIR HANDLERS . 40COILS . 48ACCESSORIES - LIGHT COMMERCIAL . 52MODELS TO KITS MATCHUP . 53ASSOCIATED KITS . 62PRODUCT DESIGN . 74SYSTEM OPERATION . 77TROUBLESHOOTING CHART . 81Pride and workmanship go into every product to provide our customers with quality products. It is possible, however, that during itslifetime a product may require service. Products should be serviced only by a qualified service technician who is familiar with thesafety procedures required in the repair and who is equipped with the proper tools, parts, testing instruments and the appropriateservice manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE SERVICE MANUAL BEFORE BEGINNING REPAIRS.IMPORTANT NOTICES FOR CONSUMERS AND SERVICERSRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELSTHIS UNIT SHOULD NOT BE CONNECTED TO. OR USED INCONJUNCTION WITH, ANY DEVICES THAT ARE NOT DESIGN CERTIFIEDFOR USE WITH THIS UNIT ORHAVE NOT BEEN TESTED AND APPROVED BY THE MANUFACTURER.SERIOUS PROPERTY DAMAGE OR PERSONAL INJURY, REDUCED UNITPERFORMANCEAND/OR HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OFDEVICES THAT HAVE NOT BEEN APPROVED OR CERTIFIED BY THEMANUFACTURER.TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHERFLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLICANCE.HIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT.FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURYOR DEATH.ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL, ADJUST, SERVICE ORREPAIR ( HEREINAFTER, “SERVICE”) THE EQUIPMENT SPECIFIED IN THISMANUAL SHOULD SERVICE THE EQUIPMENT. THE MANUFACTURER WILL NOTBE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROMIMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU SERVICE THIS UNIT, YOUASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAYRESULT. IN ADDITION, IN JURISDICTIONS THAT REQUIRE ONE OR MORELICENSES TO SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL, ONLYLICENSED PERSONNEL SHOULD SERVICE THE EQUIPMENT. IMPROPERINSTALLATION, ADJUSTMENT, SERVICING OR REPAIR OF THE EQUIPMENTSPECIFIED IN THIS MANUAL, OR ATTEMPTING TO INSTALL, ADJUST, SERVICE ORREPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPERTRAINING MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONALINJURY OR DEATH.To locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased this product.For further assistance, please contact:CONSUMER INFORMATION LINEGOODMAN BRAND PRODUCTSTOLL FREE1-877-254-4729 (U.S. only)email us at: customerservice@goodmanmfg.comfax us at: (713) 856-1821AMANA BRAND PRODUCTSTOLL FREE1-877-254-4729 (U.S. only)email us at: customerservice@goodmanmfg.comfax us at: (713) 856-1821(Not a technical assistance line for dealers.)(Not a technical assistance line for dealers.)Outside the U.S., call 1-713-861-2500.(Not a technical assistance line for dealers.) Your telephone company will bill you for the call.is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.2

IMPORTANT INFORMATIONSAFE REFRIGERANT HANDLINGWhile these items will not cover every conceivable situation, they should serve as a useful guide.REFRIGERANTS ARE HEAVIER THAN AIR. THEY CAN “PUSH OUT” THE OXYGEN INYOUR LUNGS OR IN ANY ENCLOSED SPACE. TO AVOID POSSIBLE DIFFICULTY INBREATHING OR DEATH: NEVER PURGE REFRIGERANT INTO AN ENCLOSED ROOM OR SPACE. BY LAW,ALL REFRIGERANTS MUST BE RECLAIMED. IF AN INDOOR LEAK IS SUSPECTED, THOROUGHLY VENTILATE THE ARABEFORE BEGINNING WORK. LIQUID REFRIGERANT CAN BE VERY COLD. TO AVOID POSSIBLE FROSTBITE ORBLINDNESS, AVOID CONTACT WITH REFRIGERANT AND WAR GLOVES ANDGOGGLES. IF LIQUID REFRIGERANT DOES CONTACT YOUR SKIN OR EYES, SEEKMEDICAL HELP IMMEDIATELY. ALWAYS FOLLOW EPA REGULATIONS. NEVER BURN REFRIGERANT, ASPOISONOUS GAS WILL BE PRODUCED.THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY ("EPA")HAS ISSUED VARIOUS REGULATIONS REGARDING THE INTRODUCTION ANDDISPOSAL OF REFRIGERANTS INTRODUCED INTO THIS UNIT. FAILURE TOFOLLOW THESE REGULATIONS MAY HARM THE ENVIRONMENT AND CANLEAD TO THEH IMPOSITION OF SUBSTANTIAL FINES. THESE REGULATIONSMAY VARY BY JURISDICTION. SHOULD QUESTIONS ARISE, CONTACT YOURLOCAL EPA OFFICE.SYSTEM CONTAMINANTS, IMPROPER SERVICE PROCEDURE AND/OR PHYSICALABUSE AFFECTING HERMETIC COMPRESSOR ELECTRICAL TERMINALS MAY CAUSEDANGEROUS SYSTEM VENTING.The successful development of hermetically sealed refrigerationcompressors has completely sealed the compressor's movingparts and electric motor inside a common housing, minimizingrefrigerant leaks and the hazards sometimes associated withmoving belts, pulleys or couplings.Fundamental to the design of hermetic compressors is a methodwhereby electrical current is transmitted to the compressormotor through terminal conductors which pass through thecompressor housing wall. These terminals are sealed in adielectric material which insulates them from the housing andmaintains the pressure tight integrity of the hermetic compressor. The terminals and their dielectric embedment are stronglyconstructed, but are vulnerable to careless compressor installation or maintenance procedures and equally vulnerable tointernal electrical short circuits caused by excessive systemcontaminants.TO AVOID POSSIBLE EXPLOSION: N EVER APPLY FLAME OR STEAM TO A REFRIGERANT CYLINDER. IF YOU MUSTHEAT A CYLINDER FOR FASTER CHARGING, PARTIALLY IMMERSE IT IN WARMWATER. N EVER FILL A CYLINDER MORE THAN 80% FULL OF LIQUID REFRIGERANT. N EVER ADD ANYTHING OTHER THAN R-22 TO AN R-22 CYLINDER OR R410A TO AN R-410A CYLINDER. THE SERVICE EQUIPMENT USED MUST BELISTED OR CERTIFIED FOR THE TYPE OF REFRIGERANT USED. S TORE CYLINDERS IN A COOL, DRY PLACE. NEVER USE A CYLINDER AS APLATFORM OR A ROLLER.TO AVOID POSSIBLE EXPLOSION, USE ONLY RETURNABLE (NOT DISPOSABLE)SERVICE CYLINDERS WHEN REMOVING REFRIGERANT FROM A SYSTEM. ENSURE THE CYLINDER IS FREE OF DAMAGE WHICH COULD LEAD TO ALEAK OR EXPLOSION. ENSURE THE HYDROSTATIC TEST DATE DOES NOT EXCEED 5 YEARS. ENSURE THE PRESSURE RATING MEETS OR EXCEEDS 400 PSIG.WHEN IN DOUBT, DO NOT USE CYLINDER.TO AVOID POSSIBLE INJURY, EXPLOSION OR DEATH , PRACTICE SAFEHANDLING OF REFRIGERANTS.In either of these instances, an electrical short between theterminal and the compressor housing may result in the loss ofintegrity between the terminal and its dielectric embedment. Thisloss may cause the terminals to be expelled, thereby venting thevaporous and liquid contents of the compressor housing andsystem.A venting compressor terminal normally presents no danger toanyone, providing the terminal protective cover is properly inplace.If, however, the terminal protective cover is not properly in place,a venting terminal may discharge a combination of(a) hot lubricating oil and refrigerant(b) flammable mixture (if system is contaminatedwith air)in a stream of spray which may be dangerous to anyone in thevicinity. Death or serious bodily injury could occur.Under no circumstances is a hermetic compressor to be electrically energized and/or operated without having the terminalprotective cover properly in place.See Service Section S-17 for proper servicing.3

PRODUCT IDENTIFICATIONA N Z 131234,50181AA6,7,8910,11BrandEngineeringA - Amana brandMajor/Minor RevisionsTypeNVoltage1 - 208/230V Single-Phase 60 HzDeluxe Split System2 - 220/240V Single-Phase 50 HzType3 - 208/230V Three-Phase 60 HzX:Condenser R-410A4 - 460V Three-Phase 60 HzZ:Heat Pump R-410A5 - 380/415V Three-Phase 50 HzSEER11 - 11 SEER13 - 13 SEERNominal Capacity14 - 14 SEER16 - 16 SEER418 24 30 36 1-1/2 Tons2 Tons42 3-1/2 Tons2-1/2 Tons59 5 Tons60 5 Tons61 5 Tons3 Tons48 4 Tons

PRODUCT IDENTIFICATIONS S Z 141234,503667,81 AA910,11EngineeringBrandGGoodman brand(Standard Feature Set)SGoodman brand(High Feature Set)AAmana brandDeluxeDGoodman brandDeluxeVValue LineMajor/Minor RevisionsVoltageTypeS1 - 208/230V Single-Phase 60 HzSplit System2 - 220/240V Single-Phase 50 HzType3 - 208/230V Three-Phase 60 HzX:Condenser R-410A4 - 460V Three-Phase 60 HzZ:Heat Pump R-410A5 - 380/415V Three-Phase 50 HzSEER13 - 13 SEER18 1-1/2 Tons42 3-1/2 Tons14 - 14 SEER24 2 Tons48 4 Tons0 Legacy PlaceholderN Sold in North Region30 2-1/2 Tons59 5 Tons36 3 Tons60 5 TonsS Sold in Southeast and North Regions38 3 Tons16 - 16 SEER18 - 18 SEERA Sold in All Regions5

PRODUCT IDENTIFICATIONC A P F123418245,6,7,8A 6 AA91011,12BrandCEngineering*Major/Minor RevisionsIndoor CoilRefrigerant ChargeUnit ApplicationA Upflow/Downflow Coil2 R-22H Horizontal A-Coil6 R-410A or R-22SHorizontal Slab CoilTCoated Coils4 R-410ANominal Width for Gas FurnaceA Fits 14" Furnace CabinetB Fits 17-1/2" Furnace CabinetC Fits 21" Furnace CabinetD Fits 24-1/2" Furnace CabinetN Does Not Apply (Horizontal Slab CoilsU UnpaintedNominal Capacity @ 13 SEER1824 1-1/2 - 2 TonsP3030 2-1/2 Tons3131 2-1/2 Tons3636 3 TonsExpansion Device3642 3 - 3-1/2 TonsFTFlowratorFactory-Installed Non-Adjustable3743 3 - 3-1/2 Tons4860 4 - 5 TonsExpansion Valve4961 4 - 5 TonsCabinet FinishPaintedN Unpainted Case6

PRODUCT IDENTIFICATIONMB R 81,23400AA15,6789ElectricalBrandMB - Modular Blower1: 208-230V/60Hz/1 PHDesign SeriesTypeRE-A: First SeriesSpeedVariable SpeedCircuit BreakerAirflow8: 800 CFMA: No Circuit BreakerB:Circuit Breaker12: 1200 CFM16: 1500 CFMFactory Heat20: 2000 CFM00 No Heat7

PRODUCT IDENTIFICATIONAWU F1234364215,6,7,896 AA1011,12BrandAEngineering*AirhandlerMajor/Minor RevisionsUnit ApplicationCRefrigerant ChargeCeiling Mount PSC Motor4 R-410aD Downflow PSC MotorE Multi PositionElectricalVariable SpeedRMulti Position PSC MotorSMulti Position EEM MotorTCoated Coils1 208/240V, 1 Phase, 60 HzNominal CapacityW Wall Mount PSC/EEM Motor@ 13 SEER Dedicated Application3636 3 TonMulti-Position & Downflow ApplicationCabinet Finish1830 1-1/2 - 3-1/2 TonsU Unpainted3137 3 TonsP3642 3 - 3-1/2TonsPaintedN UncasedMulti-Position & Downflow Application @10 SEER1729 3 TonExpansion DeviceFFlowratorTExpansion ValveCeing Mount & Wall Mount Applications(Nominal Cooling Capacity/Electric Heat kW)1803 1-1/2 Tons Cooling/3 kW Electric Heat1805 1-1/2 Tons Cooling/5 kW Electric Heat2405 2 Tons Cooling/5 kW Electric Heat3608 3 Tons Cooling/8 kW Electric Heat3105 1-1/2 - 2-1/2 Tons Cooling/5 kW Electric Heat3210 2 - 2-1/2 Tons Cooling/5 kW Electric Heat3705 3 Tons Cooling/5 kW Electric Heat3708 3 Tons Cooling/8 kW Electric Heat3710 3 Tons Cooling/10 kW Electric HeatAn "F" in the model number denotes aFactory Installed Float Switch is present.All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-240v, 60 hz, 1 phase.8

PRODUCT IDENTIFICATIONA R U F 18 B 1 4 AA12345,678910,11BrandAEngineering*Major/Minor RevisionsSingle-PieceAirhandlerUnit ApplicationCCeiling Mount PSC MotorRMulti Position PSC MotorSMulti Position EEM MotorRefrigerant Charge4 R-410aElectricalW Wall Mount PSC/EEM Motor1 208/240V, 1 Phase, 60 HzCabinet WidthCabinet FinishU UnpaintedB 17- 1/2" WidePC 21" WidePaintedN UncasedD 24 -1/2" WideExpansion DeviceFFlowrator18 1-1/2 TonsTExpansion Valve24 2 Tons25 2 Tons29 2-1/2 - 3 TonsNominal Capacity @ 13SEER39 2-1/2 - 3 Tons42 3-1/2 Tons47 3-1/2 Tons48 4 Tons30 2-1/2 Tons49 4 Tons33 1 1/2 - 2 Tons59 5 Tons36 3 Tons37 2-1/2 - 3 Tons60 5 Tons61 5 TonsAirhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase.9

PRODUCT IDENTIFICATIONLIGHT COMMERCIALG S X 111234,50901AA6,7,8910,11BrandEngineeringG - Goodman brandMajor/Minor RevisionsA - Amana brandTypeSVoltage1 - 208/230V Single-Phase 60 HzSplit System2 - 220/240V Single-Phase 50 HzType3 - 208/230V Three-Phase 60 HzX:Condenser R-410A4 - 460V Three-Phase 60 HzZ:Heat Pump R-410A5 - 380/415V Three-Phase 50 HzSEER11 - 11 SEER13 - 13 SEERNominal Capacity14 - 14 SEER16 - 16 SEER036 - 3 Tons048 - 4 Tons060 - 5 Tons090 - 7-1/2 Tons120 - 10 TonsA R 090 AA123,4,56,7BrandA Single PieceAir HandlerMajor/Minor RevisionsUnit ApplicationNominal CapacityRMulti PositionPSC MotorEngineering090 7-1/2 Tons120 10 TonsFor use with GSX/GSZ11 Light Commercial models only.10

PRODUCT IDENTIFICATIONLIGHT COMMERCIALGSX11 LIGHT COMMERCIALGOODMAN BRAND SPLIT X-R410A CONDENSERS 11 oduction of Goodman Light Commercial 11 SEER, R-410A 904AB208-230V and 460V 3 Phase condensing units with new ball valve/brackets, suctiontube/assembly and panel w/offset.GSZ11 LIGHT COMMERCIALGOODMAN SPLIT Z-R410A HEAT PUMP 11 oduction of Goodman Light Commercial 11 SEER, R-410A Heat 208-230V and 460V 3 Phase R410A heat pump units with new ball valve/brackets, suctiontube/assembly and panel w/offset.AR LIGHT COMMERCIALA SINGLE PIECE R-MULTI-POSITION PSC on of new 7.5 & 10 Ton Air Handler Models, for use with GSX11 and GSZ11Light Commercial Models.11

PRODUCT IDENTIFICATIONSplit System Heat PumpsASZ13AMANA BRAND SPLIT Z-R410A HEAT PUMP 13 SEERModel/Rev12DescriptionASZ130**1AAInitial release of Amana Brand 13 SEER Heat Pump R410A.ASZ130**1ABIntroduces new revisions with improved circuiting for effective defrost.ASZ130[18, 36-60]1ABASZ130[24-30]1ACIntroduces models containing crankcase heater, CCH switch and upgraded defrostcontrol.ASZ130[18, 36-60]1ACASZ130[24-30]1ADRelocation of low pressure switch from liquid line to suction line as a compressorsafeguard to prevent low pressure from entering.ASZ130[18, 36-60]1ADASZ130[24-30]1AEInitial release of models using single speed PSC motors; removal of low ambienttemperature switch.ASZ130241BARelease of 2 Ton models, converting from 3/8" to 5mm condenser coilsASZ130181AFASZ130[24-30]1AGCurrent reversing valve change from Dunan to new SanHua reversing valveASZ130481AFCurrent Ranco reversing valve 0151M00020 replaced by SanHua 0151R00070 reversingvalveASZ130361AGASZ130421AHChange from copper wound motor to aluminum wound motor.ASZ130481AGASZ130601AFCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807ASZ130181AGASZ130[24,30]1AHReplaced motor 0131M000266 with 0131M00811ASZ130421AJChange from copper wound compressor motor to aluminum wound compressor motor.ZP34K5EPFV130 and ZP36K5EPFV130.

Split System Heat PumpsPRODUCT IDENTIFICATIONASZ14AMANA BRAND SPLIT Z-R410A HEAT PUMP 14 SEERModel/RevASZ140**1AADescriptionInitial release of Amana Brand 14 SEER Heat Pump R410A with sound blankets andCoresense control.ASZ140**1ABScrew locations moved in the top panel, base pans, louvers, and control box covers.ASZ140**1ACHorizontal style louvers.ASZ140[18, 42-48]1ADASZ140[24-36, 60]1AENew steel muffler, and suction tubes w/shock loop.ASZ140361AFASZ140421ADASZ140[48-60]1AETXV & compensator replaced with flowrator & accumulator.ASZ140[18, 30,36]1AFASZ140241AGASZ14[42, 48, 60]1AESanhua (RANCO) reversing valves.ASZ140241AFSmaller B1227315 reversing 60]1AFIntroduction of heat pumps with accumulators, crankcase heaters, and upgraded defrostcontrol.ASZ140361BAChassis size reduction from large to medium.ASZ140[18, 30]1AHASZ140241AJASZ140[42-60]1AGRelocation of low pressure switch from liquid line to suction line as a compressorsafeguard to prevent low pressure from entering.ASZ140[18, SZ140[42-60]1AK2 speed PSC motors replaced with single speed PSC motors.Revision made for design improvement.*ASZ14 CONTINUED ON THE NEXT PAGE13

PRODUCT IDENTIFICATIONSplit System Heat PumpsASZ14AMANA BRAND SPLIT Z-R410A HEAT PUMP 14 SEERModel/RevDescriptionASZ140381AA35" chassis with 6-channel flowrator and ZP29K5 compressor.ASZ140[18-30]1BAUpdated ratings and agency information.ASZ140[18-60]1KAIntroduction of ready 15, 14 SEER heat pumps to meet the 2015 energy efficiencyrequirement.ASZ140[42,49]1KBMotor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.ASZ140181KCChange from copper wound motor to aluminum wound motor.ASZ140[24,30,36,48,60]1KBASZ140[42,49]1 KCRefrigerant Charge ReductionASZ140181KDRefrigerant Charge ReductionASZ140[24,30,36]1KCEquivalent motor with Aluminum Windings replacing Copper Windings.ASZ140[48,60]1KCCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M0080714

PRODUCT IDENTIFICATIONSplit System Heat PumpsASZ16AMANA BRAND SPLITS Z-R410A HEAT PUMP 16 SEERModel/RevASZ160**1AADescriptionInitial release of Amana Brand 16 SEER Heat Pump R410A.ASZ160**1ACIntroduces models with screw locations moved in the top panel, base pans, louvers, andcontrol box covers.Horizontal style louvers.ASZ160**1ADMuffler and standardized TXV, Compensator using the ASZ18 Seer weldment.ASZ160241ADASZ160[36-60]AEAdds new steel muffler, and suction tubes w/shock loop.ASZ160[24,36]1AFASZ160[48,60]1AFSanhua (RANCO) reversing valves.ASZ160[24,36,48,60]1KAInitial release of Amana Brand 16 SEER Heat Pump modelsASZ160[18-48]1LAInitial release of Amana Brand 16 SEER Heat Pump models with 9.6 HSPFASZ160601LAInitial release of Amana Brand 5 Ton 16 SEER, 13 eer Heat Pump models.ASZ160[24,30]1LBMotor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.ASZ160181LB16SEER 1.5T Heat Pumps, Remove Hard Start KitASZ160181LCChange from copper wound motor to aluminum wound motor.ASZ160[36,48]1LBCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807ASZ160421LBReplaced motor 0131M00018P with 0131M00813ASZ160**1ABASZ18AMANA BRAND SPLIT Z-R410A HEAT PUMP 18 SEERModel/RevDescriptionASZ180**1ABInitial release of Amana Brand 18 SEER Heat Pump R410A.ASZ180[36,48,60]1ACSanhua (RANCO) reversing valves.15

PRODUCT IDENTIFICATIONSplit System Heat PumpsANZ13AMANA BRAND SPLIT SYSTEM N-BASE Z-R410A HEAT PUMP 13 SEERModel/RevDescriptionANZ130[18-60]1AAInitial release of Amana Brand Split System Base Heat Pump, 13 Seer R-410A units.ANZ130[18/24/30]1ABReversing valve change from Dunan to new SanHua reversing valveANZ130481ABRanco 0151M00020 reversing valve changed to new SanHua 0151R00070 reversing valveANZ130241ACCreate new Motor & Replace 0131M00294 with 0131M00800ANZ130601ABCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807ANZ130[18,30]1ACReplaced motor 0131M000266 with 0131M00811ANZ130[36,42,48]1ACReplaced motor 0131M00018P with 0131M00813ANZ130421ADANZ130421AEChange from copper wound compressor motor to aluminum wound compressor motor.ZP34K5EPFV130 and ZP36K5EPFV130.ANZ14AMANA BRAND SPLIT SYSTEM N-BASE Z-R410A HEAT PUMP 14 on of ready 15, 14 SEER heat pumps to meet the 2015 energy efficiencyrequirement.ANZ140(24-30)1ABEnergy guide update.ANZ140181ABMinor revisions on OD units ZP14K6 compressors without hard start kit.14S 1.5T HPs ONLY.ANZ140421ABANZ140491ABMotor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.ANZ140[18,30]1ACANZ140361ABChange from copper wound motor to aluminum wound motor.ANZ140[42,49]1ACANZ140[48,60]1ABRefrigerant Charge ReductionANZ140[18,30]1ADANZ140361ACRefrigerant Charge ReductionANZ140241ADEquivalent motor with Aluminum Windings replacing Copper Windings.ANZ140[48,60]1ACCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M0080716

PRODUCT IDENTIFICATIONSplit System Heat PumpsDSZ16DELUXE SPLIT Z-R410A HEAT PUMP 16 SEERModel/RevDescriptionDSZ160**1AAInitial release of Deluxe Goodman 2-stage 16 SEER heat pumps with R-410A.DSZ160241ACDSZ16036, 48, 60]1ABSanhua (RANCO) reversing valves.DSZ18DELUXE SPLIT Z-R410A HEAT PUMP 18 SEERModel/RevDescriptionDSZ180**1AAInitial release of Deluxe Goodman 2-stage 18 SEER heat pumps with R-410A.DSZ180[36, 48, 60]1ABSanhua (RANCO) reversing valves.17

Split System Heat PumpsPRODUCT IDENTIFICATIONVSZ13VALUE SPLIT Z-R410A HEAT PUMP 13 SEERModel/RevDescriptionVSZ13**1AAInitial release of Value Line 13 SEER heat pumps with R-410A.VSZ130[24 & 30]1ABImproved circuiting for effective defrost.VSZ130[24 & 36]1BAInitial release of models with 5mm Smart Coil .VSZ130[18, 42, 48]1ABVSZ130241BBVSZ130301ACModels containing crankcase heater, CCH switch and upgraded defrost control.VSZ130[24 & 36]1BCVSZ130301AEVSZ130[18, 42 & 48]1ADRelease of single phase models with new 6 pole motor.VSZ130[18, 42-60]1ACVSZ130301ADRelocation of low pressure switch from liquid line to suction line as a compressorsafeguard to prevent low pressure from entering.VSZ130241CARelease of 2 Ton models with a compressor change from ZP21K5EPFV130 toZP20K5EPFV130.VSZ130181AEVSZ130421AFChanged from four-piece louver assembly to a two piece louver assembly. Added a cornerpost on 26" and 29" chassis.VSZ130361BDVSZ130301AFVSZ130481AESingle phase models with new 6 pole motor.Changed from four-piece louver assembly to a two piece louver assembly. Added a cornerpost on 26" and 29" chassis.VSZ130421AFCompressor change from ZP36K5EPFV130 to ZP34K5EPFV130.VSZ130241CB2 Ton models changing from the current four piece louver assembly, to a two piece louverplus a corner post on Goodman and value series 26" and 29" chassis.VSZ130181AFVSZ130241BDVSZ130301AGReversing valve change from Dunan to new SanHua.VSZ130481AFRanco 0151M00020 reversing valve replaced by SanHua 0151R00070 reversing valveVSZ130241BECreate new Motor & Replace 0131M00294 with 0131M00800VSZ130601ADCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M0080718

PRODUCT IDENTIFICATIONSplit System Heat PumpsVSZ14VALUE SPLIT Z-R410A HEAT PUMP 14 ion of ready 15, 14 SEER heat pumps to meet the 2015 efficiency requirement.VSZ140(18-30)1ABEnergy guide update. PCBDM160 with new software.VSZ140421ABVSZ140491ABMotor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.VSZ140[18,30]1ACVSZ140[36,48,60]1ABRefrigerant charge reduction.VSZ140[18, 30]1ADVSZ140361ACChange from copper wound motor to aluminum wound motor.VSZ140[24, 42, 49]1ACRefrigerant Charge ReductionVSZ140241ADEquivalent motor with Aluminum Windings replacing Copper Windings.VSZ140[48,60]1ACCreate new Motor 0131M00807 & Replace 0131M00061 with ]1AEGMC product for outdoor splits is changing the paint color to match the new paint forGMC indoor furnaces being released.VSZ140181BAConvert VSZ 14 SEER 1.5 Ton HP from Copeland to Rechi Compressor19

Split System Heat PumpsPRODUCT IDENTIFICATIONGSZ13GOODMAN SPLIT Z-R410A HEAT PUMP 13 SEERModel/RevDescriptionGSZ13**1AAInitial release with Regal Beloit motor.GSZ13**1ABGSZ13**3AAGSZ13**4AAInitial release with Broad Ocean motor.GSZ130[24 & 30]1ACRelease of minor revision with improved circuiting for effective defrost.GSZ130[24 & 36]1BAInitial release of models with 5mm Smart Coil .GSZ130241CARelease of 2 Ton models with a compressor change from ZP21K5EPFV130 toZP20K5EPFV130.GSZ130241CB2 Ton models changing from the current four piece louver assembly, to a two piece louverplus a corner post on Goodman and value series 26" and 29" chassis.GSZ130[18, DGSZ130484ACRelease of models containing crankcase heater, CCH switch and upgraded defrost control.Relocation of low pressure switch from liquid line to suction line as a compressor safeguardto prevent low pressure from entering.Changing from the current four piece louver assembly, to a two piece louver plus a cornerpost on Goodman and value series 26" and 29" chassis.GSZ130361BCGSZ130[42,48]1AERelease of models with new 6 pole motor/fan combination.GSZ130361BDModels with new 6 pole motor/fan combination. Changing from the current four piece louverassembly, to a two piece louver plus a corner post on Goodman and value series 26" and29" chassis.GSZ130421AFRelease of two piece louver plus corner post on 26" and 29" chassis with compressorchanging from ZP36K5EPFV130 to ZP34K5EPFV130.GSZ130[36, 48]3ACRelease of 3 phase models with new 6 pole motor.GSZ14**1AAInitial release of 14 SEER models.GSZ130481AGGSZ130483AEGSZ130484ADReplaced Ranco reversing valve 0151M00020 with SanHua 0151R00070 reversing valve .*GSZ13 CONTINUED ON THE NEXT PAGE20

PRODUCT IDENTIFICATIONSplit System Heat PumpsGSZ13GOODMAN SPLIT Z-R410A HEAT PUMP 13 EGSZ130251ACCreate new Motor & Replace 0131M00294 with 0131M00800GSZ130601AECreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807GSZ130181AHGSZ130301AJReplaced motor 0131M000266 with 81AHReplaced motor 0131M00018P with 0131M00813GSZ130421AKGSZ130421ALChange from copper wound compressor motor to aluminum wound compressor motor.ZP34K5EPFV130 and ZP36K5EPFV130.21

PRODUCT IDENTIFICATIONSplit System Heat PumpsGSZ14GOODMAN SPLIT Z-R410A HEAT PUMP 14 AIntroduction of ready 15 14 SEER heat pumps to meet the 2015 energy efficiencyrequirement.GSZ140(18-30)1KBEnergy guide update. PCBDM160 with new software.GSZ140301KCGSZ140361KBMigrating from copper to aluminum motors.GSZ140[42,49]1KBMotor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.GSZ140181KCGSZ140361KCRefrigerant charge reduction.GSZ140[24,30]1KDGSZ140[48,60]1KBNew model revisions, GSZ140241KD, GSZ140301KD, GSZ140481KB and GSZ140601KBwill have the BOMs changed and have a lower refrigerant charge.GSZ140[24,30]1KEGSZ140[48,60]1KCNew model revisions to deplete current overstock of Ranco reversing valvesGSZ140181KDChange from copper wound motor to aluminum wound motor.GSZ140[42,49]1KCRefrigerant Charge ReductionGSZ140241KFEquivalent motor with Aluminum Windings replacing Copper Windings.GSZ140371ABGSZ140[48,60]1KDCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807GSZ16GOODMAN SPLIT Z-R410A HEAT PUMP 16 SEERModel/RevDescriptionGSZ160[18-48]1BAInitial release of Goodman 16 SEER, 13 EER Heat Pumps with 9.0 HSPFGSZ1160601BAInitial release of Goodman 5 Ton 16 SEER, 13 EER Heat PumpsGSZ160241BBGSZ160301BBMotor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.GSZ160181BB16 SEER 1.5T Heat Pumps, Remove Hard Start KitGSZ160181BCEquivalent motor with Aluminum Windings replacing Copper 8,60]1BBSwitching current Goodman 16SEER condensers and heat pumps with grille tops to louvertops to be consistent with other Goodman units having louver-style top panels.GSZ160[36,48]1BCCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807GSZ160421BCReplaced motor 0131M00018P with 0131M0081322

Split System Heat PumpsPRODUCT IDENTIFICATIONSSZ14SPECIAL HIGH FEATURE SPLIT Z-R410A HEAT PUMP 14 SEERModel/RevDescriptionSSZ140**1AAInitial release of Goodman 14 SEER Heat Pump R410A.SSZ140**1ABScrew locations moved in the top panel, base pans, louvers, and control box covers.SSZ140**1ACBroad Ocean Motors.SSZ140181ACSSZ140241AFSSZ140301ADDischarge line mufflers added.SSZ140361AFSSZ140[42-60]1ADAdded discharge line mufflers. Replaced TXV and compensator with flowrator andaccumulator.SSZ140241AGSmaller B1227315 reversing valve.SSZ140[18, 30, 42-60]AESSZ140241AHSSZ140361AGSanhua (RANCO) reversing valves.SSZ140[18, 30, 42-60]AFSSZ140241AJSSZ140361AHIntroduction of heat pumps with accumulators, crankcase heaters, and upgraded 1BBChanged from four-piece louver assembly to a two piece louver assembly. Added a cornerpost on Goodman 26" and 29" chassis.SSZ140140[18, 30]1AJSSZ140[19, 25]1ACSSZ140[31, 81ABSSZ140[42-60]AHRevision made for design improvement.SSZ140[18-60]1ADRelocation of low pressure switch from liquid line to suction line as a compressorsafeguard to prevent low pressure from entering.SSZ140361AFSSZ140[42-60]1ADChassis size reduction from large to medium.SSZ140381AAInitial release of 35" chassis with 6-channel flowrator and ZP29K5 compressor.SSZ140[18-30]1BAUpdated ratings and agency information.SSZ140241BBSSZ140251AEChange from copper wound motor to aluminum wound motor.SSZ140361BE

Dec 24, 2014 · T Nominal Width for Gas Furnace A Fits 14" Furnace Cabinet B Fits 17-1/2" Furnace Cabinet C Fits 21" Furnace Cabinet D Fits 24-1/2" Furnace Cabinet N Does Not Apply (Horizontal Slab Coils Cabinet Finish U Unpainted 1-1/2 - 2 Tons PPainted 2-1/2 Tons N Unpainted Case 2-1/2 Tons 3 Tons Expansion Device 3 - 3-1/2 Tons FFlowrator 3 - 3-1/2 .

Related Documents:

CROSS-REFERENCE GUIDE What’s inside matters. OEM Model No. Brand Packard 0131G00000PS Goodman 66000 0131G00007 Goodman 66007 0131G00007S Goodman 66007 0131G00009 Goodman 66009 0131G00009S Goodman 66009 0131M00002P Goodman 66002 0131M00002S

Goodman Brown's moral adviser. Not wanting to explain who he is with and where he is going, Goodman Brown hides in the woods. Again, Goodman Brown is surprised; the woman knows his companion, who has now taken on the appearance of Goodman Brown's grand

Goodman Brown sees that the other convert is Faith. Goodman Brown tells Faith to look up to heaven and resist the devil, then suddenly finds himself alone in the forest. The next morning Goodman Brown returns to Salem Village, and every person he passes seems evil to him. He sees the minis

outside force, Goodman Brown makes a personal choice to go into the forest and meet with the devil; the choice was the true danger, and the devil only facilitates Goodman Brown’s fall. Goodman Brown is never certain whether the e

Family and the pride in their Jewish heritage instilled by their parents, the Goodman Family Judaic & Archival Museum at Temple Israel was born. The mission of the Goodman Family Judaic & Archival Museum at Temple Israel, with funding provided by the Goodman Family Judaic

modified Goodman diagrams, etc.) Spring-specific Modified Goodman diagrams, presented in the new SMI Encyclopedia of Spring Design, will be discussed. These Modified Goodman diagrams have been . An example would be reversed 90 bending . An S-N diagram plotted fro

Ancira Enterprises Inc., San Antonio, Texas Ancira co-founded the company in 1983 with Ralph Winton, growing from one Chevrolet . selling brands such as Jeep, Chrysler and KIA and becoming one of the most successful Hispanic-owned businesses. JOHN GOODMAN, CHAIRMAN AND CEO Goodman Networks Inc., Plano, Texas Goodman gained experience in

Governance Council’s Corporate Governance Principles and Recommendations, 4th Edition (CGC Principles) for the 2021 financial year. The Boards of Goodman Group consist of the Boards of GL and Goodman Funds Management Limited (GFML) as the responsible ent