ADDENDUM NO. 2 EMERGENCY GENERATOR AT THE DELAWARE ARMY .

3y ago
20 Views
2 Downloads
3.85 MB
53 Pages
Last View : 30d ago
Last Download : 3m ago
Upload by : Wade Mabry
Transcription

ADDENDUM NO. 2EMERGENCY GENERATOR AT THE DELAWARE ARMY NATIONAL GUARDDAGSBORO READINESS CENTER29757 ARMORY ROAD, DAGSBORO, DE 19939DE ARNG CONTRACT NO. 2017‐0031.0This addendum, Addendum No. 2, shall be made part of the Project Manual and Drawings datedNovember 08, 2017 for the Emergency Generator at the Delaware Army National Guard DagsboroReadiness Center.2.0Sealed bids for DEARNG Contract No. 2017‐003 – Dagsboro Readiness Center Emergency Generator,will be received by the Delaware Army National Guard at the Security Officers desk in the Main Lobbyof the Biden National Guard/Reserve Center, One Vavala Way, New Castle, Delaware, 19720 until2:00 PM local time on December 14, 2017, at which time they will be publicly opened and read aloudin the Multi‐Purpose Room. Allow ample time to enter the facility since the site is secure and eachvehicle entering the facility will need to pass through security.3.0Changes to Specifications3.1Section 26 32 14 Emergency/Standby Generator1. Article 2.6.B.1: CHANGE 3 pole, 200 ampere, mounted main line circuit breaker to 3P‐800AF/600AT with LI Adjustable Trip.2. Article 2.6.B.1: CHANGE average sound level maximum from 69dBA to 75dBA.3. Article 2.6.B.3: CHANGE to “Enclosure shall be constructed of Aluminum in lieu ofSteel.”4.0Changes to Drawings4.1No changes to drawings.5.0Substitution Requests5.1There was one substitution request from Fidelity Engineering to provide a Kohlergenerator and automatic transfer switch package. The documentation submitted forreview is complete and complies with the specification requirements. As a result, theproduct substitution shall be considered approved for bidding. A copy of the approveddocumentation is attached for reference.6.0Questions/Clarifications6.1No questions or clarifications.Matthew Galinskie, C.E.A.MG/mg17‐1251A Dagsboro Generator Addendum #2Attachments:cc:Kohler Generator SubmittalAll Registered Plan Holders

Model:150REOZJF208--600 VTier 3 EPA-Certified forStationary EmergencyApplicationsRatings RangeStandby:kWkVA60 Hz106--154106--193Generator Set RatingsAlternatorVoltage PhHz105 C R i s eStandby RatingkW/kVA Amps4S13X120/20860154/1933534DieselStandard FeaturesD Kohler Co. provides one-source responsibility for thegenerating system and accessories.D The generator set and its components areprototype-tested, factory-built, and production-tested.D The 60 Hz generator set offers a UL 2200 listing.D The generator set accepts rated load in one step.D The 60 Hz generator set meets NFPA 110, Level 1,when equipped with the necessary accessories andinstalled per NFPA standards.D A one-year limited warranty covers all generator setsystems and components. Two- and five-yearextended limited warranties are also available.D Alternator features:d The unique Fast-Responser X excitation systemdelivers excellent voltage response and short-circuitcapability using a rare-earth, permanent magnet(PM)-excited alternator.d The brushless, rotating-field alternator hasbroadrange reconnectability.D Other features:d Kohler designed controllers for guaranteed systemintegration and remote communication. SeeControllers on page 3.d The low coolant level shutdown preventsoverheating (standard on radiator models only).d Integral vibration isolation eliminates the need forunder-unit vibration spring isolators.d Multiple circuit breaker configurations.G5-371 (150REOZJF) 3/15c

Alternator atorKohler4-Pole, Rotating-FieldExciter typeBrushless, Rare-Earth,Permanent-MagnetLeads: quantity, type4RX, 4SX4TXVoltage regulatorInsulation:MaterialTemperature riseBearing: quantity, typeCouplingAmortisseur windingsVoltage regulation, no-load tofull-loadOne-step load acceptanceUnbalanced load capabilityD NEMA MG1, IEEE, and ANSI standards compliance fortemperature rise and motor starting.D Sustained short-circuit current of up to 300% of the ratedcurrent for up to 10 seconds.D Sustained short-circuit current enabling downstream circuitbreakers to trip without collapsing the alternator field.12, Reconnectable4, 120/240Solid State, Volts/HzNEMA MG1Class H130 C, Standby1, SealedFlexible DiscFullD Self-ventilated and dripproof construction.D Windings are vacuum-impregnated with epoxy varnish fordependability and long life.D Superior voltage waveform from a two-thirds pitch stator andskewed rotor.SpecificationsPeak motor starting kVA:480 V 4S13X (12 lead)Alternator(35% dip for voltages below)570Controller Dependent100% of Rating100% of RatedStandby CurrentApplication DataEngineEngine SpecificationsManufacturerEngine modelEngine typeCylinder arrangementDisplacement, L (cu. in.)Bore and stroke, mm (in.)Compression ratioPiston speed, m/min. (ft./min.)Main bearings: quantity, typeRated rpmMax. power at rated rpm, kWm (BHP)Cylinder head materialCrankshaft materialValve material:IntakeExhaustGovernor: type, make/modelFrequency regulation, no-load to full-loadFrequency regulation, steady stateFrequencyAir cleaner type, all modelsEngine ElectricalJohn Deere6068HF2854-Cycle, Turbocharged,Charge Air-Cooled6 Inline6.8 (415)106 x 127 (4.19 x 5.00)17.0:1457 (1500)7, Replaceable Insert1800177 (237)Cast IronForged SteelChromium-Silicon SteelStainless SteelJDEC Electronic L16Denso HP3Isochronous 0.25%FixedDryExhaustExhaust flow at rated kW, m3/min. (cfm)Quantity, CCA rating eachBattery voltage (DC)12 Volt/24 VoltNegative12/2465/4512/2412 Volt/24 VoltOne, 640/Two, 57012*12-volt or 24-volt engine electrical systems are available.FuelFuel SystemFuel supply line, min. ID, mm (in.)Fuel return line, min. ID, mm (in.)Max. lift, fuel pump: type, m (ft.)Max. fuel flow, Lph (gph)Max. return line restriction, kPa (in. Hg)Fuel prime pumpFuel filterPrimarySecondaryWater SeparatorRecommended fuel11.0 (0.44)6.0 (0.25)Electronic, 1.8 (6.0)96.9 (25.6)20 (5.9)Manual30 Microns2 Microns @ 98% EfficiencyYes#2 DieselLubricationExhaust SystemExhaust manifold typeEngine Electrical System (12/24 Volt*)Battery charging alternator:Ground (negative/positive)Volts (DC)Ampere ratingStarter motor rated voltage (DC)Battery, recommended cold crankingamps (CCA):Dry33.9 (1197)Exhaust temperature at rated kW, dryexhaust, C ( F)510 (950)Maximum allowable back pressure,kPa (in. Hg)7.5 (2.2)Exhaust outlet size at engine hookup,mm (in.)98 (3.86)Lubricating SystemTypeOil pan capacity, L (qt.)Oil pan capacity with filter, L (qt.)Oil filter: quantity, typeOil coolerG5-371 (150REOZJF) 3/15cFull Pressure27.0 (28.5)27.9 (29.5)1, CartridgeWater-Cooled

Application DataControllersCoolingRadiator SystemAmbient temperature, C ( F) *50 (122)Engine jacket water capacity, L (gal.)11.3 (3.0)Radiator system capacity, includingengine, L (gal.)25.7 (6.8)Engine jacket water flow, Lpm (gpm)174 (46)Heat rejected to cooling water at ratedkW, dry exhaust, kW (Btu/min.)76.3 (4340)Heat rejected to air charge cooler atrated kW, dry exhaust, kW (Btu/min.)31.8 (1810)Water pump typeCentrifugalFan diameter, including blades, mm (in.)660 (26)Fan, kWm (HP)7.7 (10.3)Max. restriction of cooling air, intake anddischarge side of radiator, kPa (in. H2O)0.125 (0.5)* Enclosure with enclosed silencer reduces ambienttemperature capability by 5 C (9 F).Snow package enclosure with enclosed silencer reduces ambienttemperature capability by 10 C (18 F).Decision-Makerr 550 ControllerProvides advanced control, system monitoring, and system diagnosticswith remote monitoring capabilities.D Digital display and keypad provide easy local data accessD Measurements are selectable in metric or English unitsD Remote communication thru a PC via network ormodem configurationD Controller supports Modbusr protocolD Integrated voltage regulator with 0.25% regulationD Built-in alternator thermal overload protectionD NFPA 110 Level 1 capabilityRefer to G6-46 for additional controller features and accessories.Operation RequirementsAir RequirementsRadiator-cooled cooling air,m3/min. (scfm)]Combustion air, m3/min. (cfm)226.5 (8000)13.6 (480)Heat rejected to ambient air:Engine, kW (Btu/min.)35.9 (2040)Alternator, kW (Btu/min.)12.3 (700)] Air density 1.20 kg/m3 (0.075 lbm/ft3)Fuel ConsumptionDiesel, Lph (gph) at % loadStandby 2(4.3)G5-371 (150REOZJF) 3/15c

TIB-102TECHNICAL INFORMATION BULLETINAlternator Data SheetAlternator Model:Frequency:Speed:Leads:4S13X60 Hz1800 RPM12 (6 Lead, 600 Volt)kW* (kVA)Class 110/190220/380Class H80 C90 C95 C105 C130 C125 C150 ndbyPowerPhaseClass 13.0)(See separate 600 volt data sheet.)* All data tested in accordance with IEEE Standard 115. Kohler Co. reserves the right to change the design or specifications without noticeand without any obligation or liability whatsoever.Submittal Data: 139/240 Volts, 0.8 PF, 1800 RPM, 60 Hz, 3 Phase, 130 C RiseSymbolPerUnitOhmsTypical Cold ResistancesSymbolValueTypical Time ConstantsPhase Resistance0.0320.007Armature Short CircuitTa0.011 sec.Rotor Resistance26.435.774Transient Short CircuitT’d0.149 sec.Transient Open CircuitTypical Field CurrentT’do1.759 sec.IfFL21.6 ampsIfNL3.9 ampsTypical q2.4280.530No LoadTypical Short Circuit RatioUnsaturatedX’du0.4740.104Harmonic 430.031Negative SequenceX20.1430.031Zero SequenceX00.0120.003Full Load0.203RMS Total Harmonic Distortion3.59%Max. Single Harmonic5thDeviation Factor (No Load, L--L) 5%Telephone Influence FactorInsulation Class 50per NEMA MG1--1.66Phase RotationHABCThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. 2017 by Kohler Co. All rights reserved.TIB-1024S13X 60 Hz 7/17ac1

4S13X, 60 Hz, 139/240, 277/480 Volts, WyeTYPICAL ALTERNATOR EFFICIENCY*1009896% Efficiency9492900.8 PF88868482800255075100125150175200225Output (KW)4S13X, 60 Hz, 139/240, 277/480 Volts, WyeTYPICAL MOTOR STARTING CHARACTERISTICS*4035% Voltage Dip3025201510500100200300400500600700Locked Rotor KVA* All data tested in accordance with IEEE Standard 115. Kohler Co. reserves the right to change the design or specifications without noticeand without any obligation or liability whatsoever.24S13X 60 Hz 7/17acTIB-102

4S13X, 60 Hz, Low Wye or Delta ConnectionSHORT CIRCUIT DECREMENT CURVETIB-1024S13X 60 Hz 7/17ac3

FIDELITY ENGINEERING CORPORATIONKOHLER GENERATOR DIVISION · 25 Loveton Circle · P.O. Box 2500· Sparks, Maryland 21152 · Telephone 1.800.787.6000 · Fax 410.771.9412Circuit BreakersThis generator is configured the following circuitbreakers manufactured by Square D:(1) 800 amp – Model: PGP36080CU33A100% Rated w/ Micrologic 5.0 Electronic Trip UnitWIRE RANGE: Three 3/0 to 500 kcmil

M-frame, P-frame, R-frame and NS630b–NS3200 Electronic Trip Circuit BreakersSection 11—Trip Curves8090100Micrologic 5.0/6.0 A/P/H Trip Units7060504030201589107654321.5.7.8.91.6CURRENT IN MULTIPLES OF Ir (Ir LONG-TIME SETTING x In).5B48095-613-04.epsMicrologic 5.0/6.0 A/P/H Trip Unit Characteristic Trip 0500040004000LONG-TIME PICKUPx In 98TIME IN SECONDS1098LONG-TIMEDELAY BANDSSECONDS AT 6 x Ir767655443322Long-time Pickup and DelayShort-time Pickup and I2t OFF DelayCharacteristic Trip Curve No. 613-4The time-current curve information is to be usedfor application and coordination purposes only.Curves apply from -30 C to 60 C (-22 F to 140 F) ambient temperature.Notes:6.There is a thermal-imaging effect that can actto shorten the long-time delay. The thermalimaging effect comes into play if a currentabove the long-time delay pickup value existsfor a time and then is cleared by the trippingof a downstream device or the circuit breakeritself. A subsequent overload will cause thecircuit breaker to trip in a shorter time thannormal. The amount of time delay reductionis inverse to the amount of time that haselapsed since the previous overload.Approximately twenty minutes is requiredbetween overloads to completely resetthermal-imaging.7. The end of the curve is determined by theinterrupting rating of the circuit breaker.8. With zone-selective interlocking ON, shorttime delay utilized, and no restraining signal,the maximum unrestrained short-time delaytime band applies regardless of the setting.9. Total clearing times shown include theresponse times of the trip unit, the circuitbreaker opening, and the extinction of thecurrent.10. For a withstand circuit breaker,instantaneous can be turned OFF. See tripcurve 613-7 on page 113 for instantaneoustrip curve. See table on page 116 forinstantaneous override values.11. Overload indicator illuminates at 100%.1.51.581.9.8SHORT-TIMEPICKUPx Ir.71.52 2.5.61.9.8SHORT-TIMEDELAY I2t OFF(FIXED-TIME DELAY)SECONDS AT 10 x Ir1064.7.6.5.53.450.4 OFF.3.4.30.3 OFF.2.15MAXIMUMUNRESTRAINEDSHORT-TIMEDELAY.20.2 OFF0.1 030.02.021 CYCLE.015.015.01.009.0081.01.009.0082 CYCLECURRENT IN MULTIPLES OF Ir(Ir LONG-TIME SETTING x 06.005.6.007.006.5.007Curve No. 0613TC0004Drawing No. B48095-613-04110 2006 Schneider Electric All Rights Reserved02/2006

M-frame, P-frame, R-frame and NS630b–NS3200 Electronic Trip Circuit BreakersSection 11—Trip CurvesMicrologic 5.0/6.0 A/P/H Trip Units Characteristic Trip Curve809010070Micrologic 5.0/6.0 A/P/H Trip 3-05.epsCURRENT IN MULTIPLES OF Ir (Ir LONG-TIME SETTING x time Pickup and I2t ON DelayCharacteristic Trip Curve No. 613-5The time-current curve information is to be usedfor application and coordination purposes only.Curves apply from -30 C to 60 C (-22 F to 140 F) ambient temperature.Notes:1.150SHORT-TIMEPICKUPx Ir10090801.57022.5610090808 .455ON4346.30.2ON220.1TIME IN SECONDS5.There is a thermal-imaging effect that can actto shorten the long-time delay. The thermalimaging effect comes into play if a currentabove the long-time delay pickup value existsfor a time and then is cleared by the trippingof a downstream device or the circuit breakeritself. A subsequent overload will cause thecircuit breaker to trip in a shorter time thannormal. The amount of time delay reduction isinverse to the amount of time that has elapsedsince the previous overload. Approximatelytwenty minutes is required between overloadsto completely reset thermal-imaging.The end of the curve is determined by theinterrupting rating of the circuit breaker.With zone-selective interlocking ON, shorttime delay utilized, and no restraining signal,the maximum unrestrained short-time delaytime band applies regardless of the setting.Total clearing times shown include theresponse times of the trip unit, the circuitbreaker opening, and the extinction of current.For withstand circuit breaker, instantaneouscan be turned OFF. See trip curve 613-7 onpage 113 for instantaneous trip curve. Seetable on page 116 for instantaneous overridevalues.See Trip Curve 613-4 on page 110 for longtime pickup and delay trip curve.1.51.50.3ONON1.9.81.9.8.7.7.6.6.5.50.4 ON.4SHORT-TIMEDELAY I2t ONSECONDS AT 10 x Ir.3.30.3 ONMAXIMUMUNRESTRAINEDSHORT-TIMEDELAY.2.15.4.20.2 ON0.1 3.02.021 CYCLE.015.015.01.009.0081.01.009.0082 CYCLECURRENT IN MULTIPLES OF Ir(Ir LONG-TIME SETTING x 06.005.6.007.006.5.007Curve No. 0613TC0005Drawing No. B48095-613-0511102/2006 2006 Schneider Electric All Rights Reserved

M-frame, P-frame, R-frame and NS630b–NS3200 Electronic Trip Circuit BreakersSection 11—Trip Curves809010070605040Micrologic 5.0/6.0 Trip Units30201589107654321.5.7.8.91.6MULTIPLES OF SENSOR RATING (In).5B48095-613-07.epsMicrologic 5.0/6.0 Trip Units Characteristic Trip aneous Pickup, 2X to 15X and OFFCharacteristic Trip Curve No. 613-7The time-current curve information is to be usedfor application and coordination purposes only.Curves apply from -30 C to 60 C (-22 F to 140 F) ambient temperature.Notes:1502.3.150INSTANTANEOUSPICKUPx In10090801009080707060605050404030TIME IN SECONDS1.4.3010 6.6.5.5.4.4.3.35.The end of the curve is determined by theinterrupting rating of the circuit breaker.Total clearing times shown include theresponse times of the trip unit, the circuitbreaker opening, and the extinction of current.The instantaneous region of the trip curveshows maximum total clearing times. Actualclearing times in this region can varydepending on the circuit breaker mechanismdesign and other factors. The actual clearingtime can be considerably faster thanindicated. Contact your local sales office foradditional information.For a withstand circuit breaker, instantaneouscan be turned OFF. See trip curve 613-7 onpage 113 for the instantaneous trip curve.See table on page 116 for the instantaneousoverride values.See trip curve 613-4 on page 110 and tripcurve 613-5 on page 111 for long-time pickup,long-time delay, short-time pickup and shorttime delay trip curves.2.22x.153x 4x6x 8x12 x 15 .02.021 CYCLE.015.015.01.009.0081.01.009.0082 CYCLEMULTIPLES OF SENSOR RATING 006.005.6.007.006.5.007Curve No. 0613TC0007Drawing No. B48095-613-0711302/2006 2006 Schneider Electric All Rights Reserved

Industrial Generator Set AccessoriesGenerator Set ControllerKohlerr Decision-Makerr 550 ControllerGeneral Description and FunctionThe Decision-Makerr 550 generator set controller providesadvanced control, system monitoring, and system diagnosticsfor optimum performance and compatibility with selectedengine Electronic Control Modules (ECM).ECM models only: The Decision-Makerr 550 controllerdirectly communicates with the ECM to monitor engineparameters and diagnose engine problems (see ControllerDiagnostics for details).Standard FeaturesDA digital display and keypad provide access to data. Thedisplay provides complete and understandable information,and the keypad allows easy local access.DMeasurements selectable in metric or English units.DThe controller can communicate directly with a personalcomputer via a network or via a modem configuration.DThe controller supports Modbusr protocol. Use with serialbus or Ethernet networks. (Ethernet requires an externalModbusr/Ethernet converter module.)DIntegrated voltage regulator providing 0.25% regulation.DBuilt-in alternator thermal overload protection.DA lockout keyswitch meets appropriate local coderequirements.Decision-Makerr 550Optional FeaturesDMonitor III, an optional menu-driven Windowsr-based PCsoftware, monitors engine and alternator parameters andalso provides control capability. See G6-76 spec sheet formore information.DMenu 15

D Kohler Co. provides one-source responsibility for the generating system and accessories. D The generator set and its components are prototype-tested, factory-built, and production-tested. D The 60 Hz generator set offers a UL 2200 listing. D The generator set accepts rated load in one step. D The 60 Hz generator set meets NFPA 110, Level 1,

Related Documents:

Re: ADDENDUM SEVEN - DELAWARE STATE POLICE - TROOP 3- BID PACK 1 Dover, Delaware 2011116.00 ADDENDUM SEVEN The addendum forms a part of the contract documents and modifies the original bidding documents dated, October 9, 2013, modified by Addendum No. 1 dated 10-18-2013, Addendum No. 2 dated

SR4B Generator Exciter - Remove and Install SMCS - 4454-010 Removal Procedure Remove The Exciter Field and Remove The Exciter Armature 1. Remove the side and rear access panels from the generator. Product: GENERATOR Model: SR4 GENERATOR 5FA Configuration: GENERATOR MOUNTED CONTROL PANEL 5FA00001-UP

Services 14-19 ("WSCA-NASPO Master Agreement" or "Master Agreement"). The Master Agreement, as now or hereafter amended, is incorporated into this addendum ("Participating Addendum") as if set forth at length. This Participating Addendum covers the Data Communications Products and Services contracts led by the

1 New Relic Data Processing Addendum This Data Processing Addendum (Addendum _) including its Exhibits and Appendices forms part of the agreement (Agreement _) for the purchase of services between New Relic, Inc. a Delaware corporation with offices located at 188 Spear Street, Suite 1200, San Francisco, CA 94105 ( New Relic _) and the entity identified as Customer on

SQL Data Generator 2 documentation About SQL Data Generator With SQL Data Generator, you can populate selected tables and entire databases with realistic data. You can populate empty tables, or add extra rows to your existing data. Quick links Release notes for Data Generator 2.0 Worked example - Setting up the data generator

2” & 3” aIr dIaPHragM PuMP 10 12’ / 24’ road CrossIng ManIfold 11 20”/24” CoPPus fan aIr MoVer 11 aIr Horns 11 ContaInMent BerM 11 8’ x 16’ eCoMats 12 25 kVa PortaBle generator 13 45 kVa PortaBle generator 13 85 kVa PortaBle generator 13 125 kVa PortaBle generator 14 150 kVa PortaBle generator 14 220 kVa PortaBle generator 14

Generator Set Controllers) Disabling the generator set. Accidental starting can cause severe injury or death. Before working on the generator set or equipment connected to the set, disable the generator set as follows: (1) Press the generator set off/reset button to shut down the generator set. (2) Disconnectthepowertothebattery charger, if .

API RP 500 and API RP 505 NFPA 497 and NFPA 499. PETRONAS Technical Standards provides guidelines to ensure proper management of Ex Equipment. 1. Ex Electrical Equipment Inspection and Maintenance Guidelines (Ex IMG) Standards and Guidelines Personnel Inspection Maintenance 2. Ex Equipment Repair Guidelines (Ex ERG) 3. Ex Management Assessment Guidelines (Ex MAG) 4. Ex .