ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BA, C, D (cUL)NEMA 3, 4XB, 7BCDRaintightWet Locations6CUtilizes Eaton’s PowerXL DG1 drivesExplosionproof VFDs are highly flexible AC drives designedspecifically for hazardous area locations. These drives can bemounted next to the motor in the classified area, providing significantinstallation cost savings – along with the traditional VFD benefits ofenergy savings, speed and torque control, and system diagnostics.6CThis revolutionary product features a NEMA 7 enclosure with patentpending active cooling technology, allowing a traditional VFD to behoused inside the classified enclosure without the risk of overheating.The ACE explosionproof VFD is rated Class I, Divisions 1 & 2 for usein the most extreme environments, and is designed to match the highrequirements of pumps, compressors, fans, separators and mixers inthe following process industries: Oil and gas/refineries OEM skid builders Petrochemical Water/wastewater Pharmaceutical Food and beverage manufacturingApplications: For speed control of pumps, compressors, fans, conveyors,separators, mixers and other process equipment Designed to meet the high reliability and safety requirements ofprocess industries such as oil and gas, chemical and miningFeatures: ACE VFDs are installed ‘on-machine’ inside the hazardous areas,eliminating expensive, complicated installations There is no need to run long lines of conduit and motor cable, digup roadways and sidewalks, navigate around obstacles and hazardsor build off-site control rooms in non-hazardous areas to house VFDclusters Reflected Wave Syndrome is eliminated due to short motor cablerunsACE DG1 features: Drives available up to 100 HP Improved temperature rating:-30 C to 50 C (up to 75 HP)-30 C to 40 C (100 HP) Standard features include:- EtherNet/IP- Modbus TCP- RS-485: Modbus RTU- BACnet MS/TPCertifications and compliances:UL classified: Class I, Divisions 1 & 2, Groups B, C, DcUL classified: Class I, Divisions 1 & 2, Groups BA, C, DUL standard: UL1203Environmental ratings: NEMA 3, 4XB, 7BCD Raintight Wet locationsOperating temperature range: 1 to 75 HP: -30ºC to 50ºC (-22ºF to 122ºF) 100 HP: -30ºC to 40ºC (-22ºF to 104ºF)Standard materials and finishes: Body and cover – copper-free aluminum, epoxy powder coatedOperating handle – copper-free aluminum, epoxy paintedWindow – tempered soda lime glassBlower – aluminum, naturalFilters – stainless steel, naturalPre-filters – stainless steel, naturalDisconnect – stainless steel, naturalShroud – copper-free aluminum, epoxy paintedCover hinges, bolts, washers and springs – stainless steel, naturalInternal brackets – stainless steel, naturalManifold and intake – EPDM rubber, naturalHorsepower ratings: Available from 1 to 100 HPVFD system specifications: Eaton PowerXL DG1 general purpose drivesA5 HP and below listed for Group B.BPlease consult factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton600

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BC, C, D (cUL)NEMA 3, 4XD, 7BCDRaintightWet LocationsUtilizes Eaton’s PowerXL DG1 drivesHeavy duty blowerE creates airflow through theenclosure, allowing VFD to operate in ambienttemperatures up to 50ºC.Variable frequency drive (VFD)in explosionproof enclosureallows installation in classifiedarea, providing significantinstallation savings.6C7.5 to 30 HPFused disconnect.C5 HP and below listed for Group B.DPlease consult factory.EHeavy duty blower, shroud, filters and pre-filter screens not included with units containing 1 to 5 HP VFDs.601www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton6C

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BF, C, D (cUL)NEMA 3, 4XG, 7BCDRaintightWet Locations6CUtilizes Eaton’s PowerXL DG1 drives hroud covering topSfilters allows water todissipate off enclosure.6CStainless steel, captive, triple lead quickrelease spring loaded bolts install faster andprovide clear indication that the cover bolts arefully retracted from the body.Stainless steel hinges provide convenient andeasy access to enclosure interior.Enclosure epoxy painted for superiorcorrosion resistance.Explosionproof window allows for viewing ofthe VFD interface module LCD screen.Internal and external grounding lugs.Explosionproof pilot lights provide run, stopand alarm indication.FiltersHin top andbottom ofenclosureallowairflowinto andout of theenclosure,cooling theVFD andeliminatingrisk of overheating.Pre-filter screensH (not shown) eliminateclogging of the primary filters, ensuring reliableand consistent airflow. Pre-filter screenscan be easily removed and cleaned withoutshutting down operations.F5 HP and below listed for Group B.GPlease consult factory.HHeavy duty blower, shroud, filters and pre-filter screens not included with units containing 1 to 5 HP VFDs.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton602

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BI, C, D (cUL)NEMA 3, 4XJ, 7BCDRaintightWet LocationsUtilizes Eaton’s PowerXL DG1 drives40 to 100 HP6C hroudScovering topfilters allowswater todissipate offenclosure.Heavy duty blower createsairflow through the enclosure,allowing VFD to operate inambient temperatures up to 50ºC.Variable frequency drive (VFD)in explosionproof enclosureallows installation in classifiedarea, providing significantinstallation savings.Internal and externalgrounding lugs.Fused disconnect.Filters in topand bottomof enclosureallow airflowinto and out ofthe enclosure,cooling theVFD andeliminating riskof overheating.Pre-filterscreenseliminate clogging of the primary filters, ensuringreliable and consistent airflow. Pre-filter screenscan be easily removed and cleaned withoutshutting down operations.I5 HP and below listed for Group B.JPlease consult factory.603www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton6C

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BK, C, D (cUL)NEMA 3, 4XL, 7BCDRaintightWet Locations6CUtilizes Eaton’s PowerXL DG1 drives6CStainless steel, captive,triple lead quick releasespring loaded boltsinstall faster and provide clearindication that the cover boltsare fully retracted from thebody.Stainless steel hingesprovide convenient and easyaccess to enclosure interior.Explosionproof windowallows for viewing of the VFDinterface module LCD screen.Explosionproof pilot lightsprovide run, stop and alarmindication.Enclosure epoxy painted forsuperior corrosion resistance.K5 HP and below listed for Group B.LPlease consult factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton604

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BM, C, D (cUL)NEMA 3, 4XN, 7BCDRaintightWet Locations6CUtilizes Eaton’s PowerXL DG1 drivesOrdering information:6CHorsepower ratingBase cat. #Nominal CE-DG1-60ACE-DG1-75ACE-DG1-1001.0 (.75)2.0 (1.5)3.0 (2.2)5.0 (3.0)7.5 (5.5)10.0 (7.5)15.0 (11.0)20.0 (15.0)25.0 (18.5)30.0 (22.0)40.0 (30.0)50.0 (37.0)60.0 (45.0)75.0 (55.0)100.0 ctfuse ratingEnclosuresize460V inputratingamperageMax. outputratingamperagePower 4AT4AT4AT4AT4AT4AT4AT4AT4AT4APart number exampleACE-DG1-60-CC-PTACE-DG1-60–CCHorsepower ratingACE-DG1-60–PTOptions (see below)Eaton PowerXL VFDwith 60 HP ratingCAN openPotentiometerModbus and Ethernet standard on all DG1 modelsCCPTOptionsCommunication tion600 VAC evicenetCAN openSmartWireLon worksRelay output6 x DI 240 VAC input option card3 x DI, 3 x DO, 24 VDCPTAB 800H-UP29600600 VACNote: 6 00 suffix option can only be used for ACE-DG1units with nominal HP of 5 or less.Local / remoteSuffixDescriptionLRTwo-position switchReplacement part kitsCat. #ACEACEACEACEACEACEKITKITKITKITKITKIT123789Drive fan replacement kitsDescriptionCat. #Pre-filter and hardware (one-piece)Filter assembly (one-piece)Blower, manifold and hardware (one-piece)3/ 8” glass window5/ 8” glass windowShroud replacement kitACEACEACEACEACEwww.crouse-hinds.comFor use with11-111-211-311-411-5ACE-DG1 1-5 HPACE-DG1 7-15 HPACE-DG1 20-30 HPACE-DG1 40-60 HPACE-DG1 75-100 HPNote: T his fan is not the main blower found inside the enclosure. ACE KIT 3 is thereplacement parts kit for the main blower. ACE KIT 11 kits are replacement fansspecifically for the VFD drive.M5 HP and below listed for Group B.NPlease consult factory.ODI option does not denote a 240 VAC supply voltage capability of the VFD.605KITKITKITKITKITPlease contact factory if a 240 VAC VFD is required.US: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BP, C, D (cUL)NEMA 3, 4XQ, 7BCDRaintightWet Locations6CUtilizes Eaton’s PowerXL DG1 drivesDimensions:Enclosure size 1 (1 to 5 HP)6CEnclosure size 2 (7.5 to 30 HP)P5 HP and below listed for Group B.QPlease consult factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 Eaton606

ACE explosionproofvariable frequency drivesCl. I, Div. 1 & 2, Groups B, C, D (UL)Cl. I, Div. 1 & 2, Groups BR, C, D (cUL)Utilizes Eaton’s PowerXL DG1 drivesDimensions (continued):6CEnclosure size 3 (40 to 100 HP)R5 HP and below listed for Group B.SPlease consult factory.607www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2019 EatonNEMA 3, 4XS, 7BCDRaintightWet Locations6C

ACE KIT 1 Pre-filter and hardware (one-piece) ACE KIT 2 Filter assembly (one-piece) ACE KIT 3 Blower, manifold and hardware (one-piece) ACE KIT 7 3/ 8” glass window ACE KIT 8 5/ 8” glass window ACE KIT 9 Shroud replacement kit Note: 600 suffix option can only be used for ACE-DG1 units with nominal HP of 5 or less. Drive fan replacement kits .