IECEx TEST REPORT IEC 60079 Electrical Equipment For .

3y ago
157 Views
21 Downloads
839.58 KB
44 Pages
Last View : 22d ago
Last Download : 3m ago
Upload by : Anton Mixon
Transcription

IECEx TEST REPORTIEC 60079Electrical equipment for explosive gas atmospheresPart 0: General requirementsExTR Reference Number . :N/AExTR Free Reference Number. :US/UL 08NK12123Complied by signature (ExTL) . :William LiReviewed by signature (ExTL) . :Susan K. KimDate of issue. :2009-10-30Ex Testing Laboratory (ExTL). :Underwriters LaboratoriesAddress. :333 Pfingsten Road, Northbrook, IL 60062 USAApplicant’s name . :Moxa Inc.Address. :4th FL, 135 Lane 235 Pao Chiao Rd.Shing Tien City Taipei, 23145, TaiwanStandard . :IEC 60079-0:2004, Fourth editionTest procedure. :IECEx SchemeTest Report Form No. . :ExTR60079-0 4ATRF Originator . :Sira Test & CertificationMaster TRF. :dated 2006-09Instructions for Intended Use of Ex Test Report:This ExTR blank document is to be compiled and reviewed by the ExTL. The ExTR package in which thisExTR is incorporated (comprised of a single ExTR document or multiple ExTR documents) is to beaccompanied by a single ExTR Cover Sheet, which is to be approved by the ExCB. ExTR Addendum(s)and/or ExTR Report of National Differences may also supplement this ExTR.Copyright 2006 International Electrotechnical Commission Scheme for Certification to StandardsRelating to Equipment for use in Explosive Atmospheres (IECEx), Geneva, Switzerland. All rightsreserved.This publication may be reproduced in whole or in part for non-commercial purposes as long as theIECEx is acknowledged as copyright owner and source of the material. IECEx takes no responsibility forand will not assume liability for damages resulting from the reader's interpretation of the reproducedmaterial due to its placement and context.Possible test case verdicts:- test case does not apply to the test object . :N / A- test object does meet the requirement . :PassGeneral remarks:The tests results presented in this report relate only to the object tested.This report shall not be reproduced except in full without the written approval of the testing laboratory."(see Attachment #)" refers to additional information appended to the report."(see appended table)" refers to a table appended to the report.Throughout this report a point is used as the decimal separator.60079-0 4:2004 4th ed.(ver 4a)

Page 2 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – TestResult – Remark1SCOPE2NORMATIVE REFERENCES3TERMS AND DEFINITIONS4APPARATUS GROUPING AND TEMPERATURE CLASSIFICATION4.1Apparatus grouping4.2Group II4.2.1Group II subdivisionsSubject Apparatus are suitable for use as aGroup IIC ApparatusPass4.2.2Group II – Surface temperaturemarkingSubject Products are marked with aTemperature Code of T4Pass4.2.3Apparatus for a particularexplosive atmosphereApparatus is not intended for use in a Particular N/AExplosive atmosphere5TEMPERATURES5.1Environmental influencesTemperature generation by the subject devicesand external temperature influences areaddressed in Clause 5.1.1 and 5.1.2Pass5.1.1Ambient temperaturesSubject Products are marked with either one ofthe following:PassThe subject devices are grouped as Group IIdevicesVerdictPassPass-40 C Ta 75 C, or-40 C Tamb 75 C5.1.2External source of heating orcoolingNo external source of heating or coolingNA5.2Service temperatureSubject Products are tested in accordance withClause 26.5.1Pass5.3Maximum surface temperature5.3.1Determination of maximumsurface temperatureThe highest maximum surface temperatureobtained during the temperature test is 120oCon Model EDS-518. For all other model’smaximum temperature, see attacheddatasheets for temperature tests.Pass5.3.2Limitation of maximum surfacetemperature5.3.2.1Group I electrical apparatusSubject Products are not Group I apparatusN/A5.3.2.2Group II electrical apparatusThe highest maximum surface temperatureobtained during the temperature test is 120oCon Model EDS-518, therefore, subject Productsare marked with T-code T4Pass60079-0 4:2004 4th ed.(ver 4a)Pass

Page 3 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – Test5.4Surface temperature and ignition This Clause is not applicable per thetemperaturerequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A5.5Small component temperaturesN/A6REQUIREMENTS FOR ALL ELECTRICAL APPARATUS6.1GeneralSubject Products are constructed in accordance Passwith this standard and IEC 60079-15, ThirdEdition6.2Mechanical strength ofapparatusNo mechanical tests are necessary since theSubject Products are to be installed in a anIP54 enclosure by the end-userN/A6.3Opening timesThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A6.4Circulating currentSubject devices utilize an adequate bondingsystemN/A6.5Gasket retentionSubject Products are to be installed in an IP54enclosure by the end-userN/A7NON-METALLIC ENCLOSURES AND NON-METALLIC PARTS OF ENCLOSURES7.1General7.1.1ApplicabilityType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A7.1.2Specification of materialsType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A7.1.3Plastic materialsType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A7.2Thermal enduranceType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A7.3Electrostatic charges on enclosures or parts of enclosures7.3.1ApplicabilityType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A7.3.2Avoidance of a build-up ofelectrostatic chargeType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A60079-0 4:2004 4th ed.(ver 4a)Result – RemarkVerdict

Page 4 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – TestResult – RemarkVerdict7.4Threaded holesType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the end-userN/A8ENCLOSURES CONTAINING LIGHT METALS8.1Material Composition8.1.1Group I8.1.2Group II8.2Threaded Holes9FASTENERS9.1GeneralType of Protection does not depend onN/Aenclosure or fasteners. Subject Products are tobe installed in an IP54 enclosure by the enduser.9.2Special fastenersThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A9.3Holes for special fastenersN/A9.3.1Thread engagement9.3.2Tolerance and clearance9.3.3Hexagon socket set screwThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1This Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1This Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1This Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 110Interlocking devicesThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A11BushingsSubject Products are to be installed in an IP54enclosure by the end-userN/A12Materials used for cementingThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A13EX COMPONENTS60079-0 4:2004 4th ed.(ver 4a)Type of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the endType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the endType of Protection does not depend onenclosure. Subject Products are to be installedin an IP54 enclosure by the endN/AN/AN/AN/AN/ANA

Page 5 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – TestResult – RemarkVerdict13.1GeneralThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A13.2Mounting internal to apparatusThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A13.3Mounting external to apparatusThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A14CONNECTION FACILITIES AND TERMINAL COMPARTMENTS14.1GeneralThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A14.2Connection spaceThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A14.3Type of protectionThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A14.4Creepage and clearanceThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A15CONNECTION FACILITIES FOR EARTHING OR BONDING CONDUCTORS15.1InternalThere are no internal wire connections in theSubject Models.Pass15.2ExternalThe Subject Models also utilize an externalgrounding screw near the power supplyterminal.Pass15.3Apparatus not requiring earthingSubject devices require earthingN/A215.4Size of conductor connectionThe external grounding conductor is 4mm orhigherPass15.5Protection against corrosionAll connection facilities are protected fromcorrosion since the Subject Models will beinstalled in an IP54 enclosurePass15.6SecurenessAll connection facilities are protected fromloosening or twisting since the Subject Modelswill be installed in an IP54 enclosurePass16ENTRIES INTO ENCLOSURES16.1GeneralSubject Products are to be installed in an IP54enclosure by the end-userN/A16.2Identification of entriesSubject Products are to be installed in an IP54enclosure by the end-userN/A16.3Cable glandsSubject Products are to be installed in an IP54enclosure by the end-user. Cable glands arenot utilizedN/A60079-0 4:2004 4th ed.(ver 4a)

Page 6 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – TestResult – RemarkVerdict16.4Blanking elementsSubject Products are to be installed in an IP54enclosure by the end-userN/A16.5Conductor temperatureThe following statement in regards to theconductor temperature is stated in the SpecialCondition of Safe Use, Installation Instructionsand Marking Label:“Conductors suitable for use in an ambienttemperature of 93 C must be used for thePower Supply Terminal”Pass17SUPPLEMENTARY REQUIREMENTS FOR ROTATING ELECTRICAL MACHINES17.1Fans and fan hoodsThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A17.2Ventilation openings for externalfansThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A17.3Construction and mounting ofthe ventilation systemsThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A17.4Clearances for the ventilatingThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A17.5Materials for external fans andfan hoodsThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A17.6Equipotential bondingconductorsThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A18SUPPLEMENTARY REQUIREMENTS FOR SWITCHGEAR18.1Flammable dielectricSubject Products do not have switchgearsN/A18.2DisconnectorsSubject Products do not have switchgearsN/A18.3Group I – Provisions for lockingSubject Products do not have switchgearsN/A18.4Doors and coversSubject Products do not have switchgearsN/A19Supplementary requirements forfusesThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A20SUPPLEMENTARY REQUIREMENTS FOR PLUGS AND SOCKETS20.1InterlockingThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A20.2Energized plugsThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A60079-0 4:2004 4th ed.(ver 4a)

Page 7 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – Test21SUPPLEMENTARY REQUIREMENTS FOR LUMINAIRES21.1GeneralThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A21.2CoversThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A21.3Special lampsThis Clause is not applicable per therequirements of EN 60079-15: 2005, Table 1 orIEC 60079-15, Third Edition, Table 1N/A22SUPPLEMENTARY REQUIREMENTS FOR CAPLIGHTS, CAPLAMPS AND HANDLAMPS22.1Group I caplights and handlights Subject Products are not caplights, caplamps or N/Ahandlamps22.2Group II caplights andhandlights23APPARATUS INCORPORATING CELLS AND BATTERIES23.1Batteries23.2Cell types23.3Cells in a battery23.4Ratings of batteries23.5Mixture of cells23.6Interchangeability23.7Charging of primary n23.11Replacement of cells or batteries Subject Products do not utilize Batteries or cells N/A24DocumentationPass25Compliance of prototype orsample with documentsPass26TYPE TESTS26.1General26.2Test configuration26.3Tests in explosive test mixtures60079-0 4:2004 4th ed.(ver 4a)Result – RemarkVerdictSubject Products are not caplights, caplamps or N/AhandlampsSubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ASubject Products do not utilize Batteries or cells N/ATemperature Testing is all that is required forthis standard. All other tests specified in thisstandard do not apply to Subject ModelsPassPassSpecific explosive test mixtures were not usedN/A

Page 8 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – Test26.4Tests of Enclosures26.4.1Order of tests26.4.1.1Metallic enclosures, metallicparts of enclosures and glass ofparts of enclosures26.4.1.2Non-metallic enclosures or nonmetallic parts of enclosuresSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.4.1.2.1Group I electrical apparatus26.4.1.2.2Group II electrical apparatus26.4.2Test for resistance toimpact/Required resultsSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.4.3Drop test/Required results26.4.4Acceptance criteria26.4.5Tests for the degree ofprotection IP by enclosures26.4.5.1Test procedure26.4.5.2Acceptance criteria26.5Thermal tests26.5.1Temperature measurementTemperature Test conducted to determineTemperature Code: The highest maximumsurface temperature obtained during thetemperature test for all models is 120oC (EDS518), therefore, T-Code T4 is obtained26.5.2Thermal shock testSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.5.3Small component ignition eptance criteriaN/A26.6Torque test for bushings26.6.1Test procedureSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.6.2Acceptance criteriaSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.7Result – RemarkSubject Products are for installation into anIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anIP54 enclosure. Tests considered unnecessaryVerdictN/AN/AN/ASubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessaryAll components have been assessed and thecomponent that displayed the max. Temp.Resulted in the T-code givenPassN/ATests of non-metallic enclosures or of non-metallic parts of enclosuresSubject Products are for installation into an26.7.1GeneralN/AIP54 enclosure. Tests considered unnecessarySubject Products are for installation into an26.7.2Temperature during testsN/AIP54 enclosure. Tests considered unnecessary60079-0 4:2004 4th ed.(ver 4a)

Page 9 of 12Report No. US/UL 08NK12123IEC 60079-0ClauseRequirement – TestResult – Remark26.8Thermal endurance to heatSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.9Thermal endurance to coldSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.10Resistance to light26.10.1Applicability26.10.2Test procedure26.10.3Acceptance criteriaSubject Products are for installation into anIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anIP54 enclosure. Tests considered unnecessary26.11Resistance to chemical agentsfor Group I electrical apparatusSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.12Earth ContinuitySubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.13Surface resistance test of partsof enclosures of non-metallicmaterialsSubject Products are for installation into anN/AIP54 enclosure. Tests considered unnecessary26.14Charging test26.14.1Subject Products are for installation into anIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anPrinciple of the testIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anSamples and apparatusIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anAmbient conditionsIP54 enclosure. Tests considered unnecessarySubject Products are for installation into anConditioningIP54 enclosure. Tests considered unnecessaryDetermination of the most efficient charging methodSubject Products are for installation into anMethod A: Rubbing with a pureIP54 enclosure. Tests considered unnecessarypolyamide cloth (figure 6)Method B: Rubbing with a cotton Subject Products are for installation into anIP54 enclosure. Tests considered unnecessaryclothMethod C: Charging by influence Subject Products are for installation into anIP54 enclosure. Tests considered unnecessarywith a d.c. high-voltage powersupply (figure 8)Subject Products are for installation into anAssessment of

IEC 60079-15, Third Edition, Table 1 N/A 9.3.1 Thread engagement This Clause is not applicable per the requirements of EN 60079-15: 2005, Table 1 or IEC 60079-15, Third Edition, Table 1 N/A 9.3.2 Tolerance and clearance This Clause is not applicable per the requirements of EN 60079-15: 2005, Table 1 or IEC 60079-15, Third Edition, Table 1 N/A

Related Documents:

en 60079-15:2010 iec-ex iec 60079-0:2017 iec 60079-11:2011 iec 60079-15:2010 ccoe peso india iec 60079-0:2011 iec 60079-11:2011 iec 60079-15:2010 csa can/csa-c22.2 no. 0-10 can/csa-c22.2 no. 61010-1-12 can/csa-c22.2 no. 60079-0:15 can/csa-c22.2 no. 60079-11:14 can/csa-c22.2 no.

C22.2 No 60079-15 2002 USA: CLASS 3600 1998 CLASS 3611 2004 CLASS 3810 2005 NEMA 60529 2004 ISA 60079-15 2003 ATEX: EN 60079-0 2009 EN 60079-11 2012 EN 60079-15 2010 IECEX IEC 60079-0 Ed 5.0 IEC 60079-11 Ed 6.0 IEC 60079-15 Ed 4.0 JAPAN This unit must be connected to the pu

EN 60079-14 and EN 60079-17 shall be considered. For countries members of IECEx, standards IEC 60079-14 and IEC 60079-17 shall be be considered. For other countries, applicable national regulation shall be considered. The products fulfill the following standards: EN IEC 60079-0:2018 (IEC 60079-0:2017) EN 60079

installations IEC 60079-17 EN 60079-17 Equipment protection by encapsulation IEC 60079-18 EN 60079-18 Equipment repair, overhaul and reclamation IEC 60079-19 EN 60079-19 Equipment protection by pressurized enclosure »p« IEC 60079-2 EN 60079

Non‐arcing Ex nA Zone 2 EN 60079‐15 IEC 60079‐15 Flameproof Ex d Zone 1 & 2 EN 60079‐1 IEC 60079‐1 Powder filling Ex q Zone 1 & 2 EN 60079‐5 IEC 60079‐5 Protected facilities and components Ex nC Zone 2 EN 60079‐15 IEC 60079‐15 Intrinsic Safety (IS) Ex ia Zone 0, 1 & 2

Inspection and maintenance of electrical systems IEC 60079-17 EN 60079-17 Equipment protection by encapsulation “m” IEC 60079-18 EN 60079-18 Equipment repair, overhaul and recycling IEC 60079-19 EN 60079-19 Equipment protection by pressurised enclosure “p” IEC 60079-2 EN 60079-2 Intrinsically safe systems I

INERIS 10 ATEX 0029X EN 60079 - 0 EN 60079 - 1 EN 60079 - 7 EN 60079 - 31 IEC 60079 - 0 IEC 60079 - 1 IEC 60079 - 7 IEC 60079 - 31 For the opti-mum choice of the cable glands see al-so sect. A Extended temperature range only with Silicon rings. Further informa-tion

to EN 60079-0:2009, EN 60079-7:2007, and EN 60079-14 Standards Ta -15 C to 120 C IECEx Certified IECEx ETL 12.0009X Ex e IIC Gb to IEC 60079-0:2007-10, Edition 5, IEC 60079-7:2006-07, Edition 4 and IEC 60079-