METTLER TOLEDODIVA Operation ManualHoneywell Stratos Series ScannersMETTLER TOLEDO(2012/05) 1.0

INTRODUCTIONThis publication is solely as a guide for individuals who purchased the METTLER TOLEDO Diva scale.Information regarding METTLER TOLEDO Technical Training may be obtained by writing to:METTLER TOLEDO1900 Polaris ParkwayColumbus, Ohio 43240-2020(614) 438-4511 Mettler-Toledo, Inc. 2006No part of this manual may be reproduced or transmitted in any form or by any means, electronic ormechanical, including photocopying and recording, for any purpose without the express writtenpermission of Mettler-Toledo, Inc.U.S. Government Restricted Rights: This documentation is furnished with Restricted Rights.METTLER TOLEDO RESERVES THE RIGHT TO MAKE REFINEMENTS OR CHANGESWITHOUT NOTICE.

PrecautionsREAD this manual BEFOREoperating or servicing thisequipment.FOLLOW these instructionscarefully.SAVE this manual forfuture reference.DO NOT allow untrainedpersonnel to operate,clean, inspect, maintain,service, or tamper withthis equipment.ALWAYS DISCONNECT thisequipment from the powersource before cleaning orperforming maintenance.CALL METTLER TOLEDO forparts, information, andservice.WARNINGONLY PERMIT QUALIFIED PERSONNEL TO SERVICETHIS EQUIPMENT. EXERCISE CARE WHEN MAKINGCHECKS, TESTS AND ADJUSTMENTS THAT MUST BEMADE WITH POWER ON. FAILING TO OBSERVETHESE PRECAUTIONS CAN RESULT IN BODILYHARM.WARNINGFOR CONTINUED PROTECTION AGAINST SHOCKHAZARD CONNECT TO PROPERLY GROUNDEDOUTLET ONLY. DO NOT REMOVE THE GROUNDPRONG.WARNINGDISCONNECT ALL POWER TO THIS UNIT BEFOREREMOVING THE FUSE OR SERVICING. FAILURE TO DOSO MAY RESULT IN BODILY INJURY OR PROPERTYDAMAGE.CAUTIONBEFORE CONNECTING/DISCONNECTING ANY INTERNAL ELECTRONIC COMPONENTSOR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYSREMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANYCONNECTIONS OR DIS-CONNECTIONS ARE MADE. FAILURE TO OBSERVE THESEPRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THEEQUIPMENT OR BODILY HARM.CAUTIONOBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVEDEVICES.

ContentsINTRODUCTION . 1DIMENSIONS . 5INSTALLATION. 6ENVIRONMENT . 6CONTENTS OF PACKAGING . 6SETUP . 6DISPLAY AND KEYBOARD . 8DISPLAY . 8KEYBOARD . 9CURSORS . 10OPERATIONS . 11WEIGHING AND COMMUNICATION . 11BACKLIGHT FUNCTION . 11RE-ZERO FUNCTION . 11TARE FUNCTION . 11SETUP . 12SETUP SOFT SWITCHES . 13SOFT SWITCHES – DEFAULT SETTINGS . 15APPENDIX . 16ERRORS . 16CLEANING AND MAINTENANCE . 16SPECIFICATIONS . 16ACCESSORIES . 17

METTLER TOLEDOIntroductionPlease read this instruction manual carefully.Computing scales.This manual is intended for use with all Diva Weigh Only and PriceThe Diva scale is combined with a scanner for full featured Checkout applications. The Diva scale is a high precisionweighing instrument. It is designed for applications where product is sold directly to customers and has to beapproved by local Weights and Measures officials.All of our equipment is assembled, tested and packed with great care.expectations, please contact us immediately.If you find something that does not meet yourThis scale will provide years of accurate weighing if properly used and maintained. Please handle it as you would anypiece of sensitive electronic equipment.GEO-ValueThe GEO-Value of verified scales explains for which location of use the scale has been verified. This GEO-Value isshown on the weight display shortly after power is applied to the SlovakiaSloveniaSpainTurkeyUnited KingdomDIVA Operation ManualGeo-Width46 22‘ – 49 01‘49 30‘ – 51 30‘41 41‘ – 44 13‘42 24‘ – 46 32‘48 34‘ – 51 03‘54 34‘ – 57 45‘41 20‘ – 51 00‘59 48‘ – 70 05‘47 00‘ – 55 00‘34 48‘ – 41 45‘45 45‘ – 48 35‘51 05 – 55 05‘63 17‘ – 67 09‘35 47‘ - 47 05‘55 30 – 58 04‘49 27‘ – 50 11‘47 03‘ – 47 14‘53 54‘ – 56 24‘50 46‘ – 53 32‘57 57‘ - 71 11‘49 00‘ – 54 30‘36 58‘ – 42 10‘43 37‘ – 48 15‘55 20‘ – 69 04‘45 49‘ – 47 49‘47 44‘ – 49 46‘45 26‘ – 46 35‘36 00‘ – 43 47‘35 51‘ – 42 06‘49 00‘ – 62 00‘Geo-Value 11518241819181516211

METTLER TOLEDOFOR YOUR NOTES:2DIVA Operation Manual

METTLER TOLEDODIVA Operation Manual3

METTLER TOLEDO4DIVA Operation Manual

METTLER TOLEDODimensionsHigh tower version for Price ComputingDIVA Operation ManualShort tower version for Weigh Only5

METTLER TOLEDOInstallationEnvironmentBefore you install your DIVA scale keep in mind the following factors, which might have a negative influenceon the scale's operation: Vibration diminishes the scale’s ability to measure accurately. Excessive vibration from equipmentsuch as conveyors can cause inaccurate and non-repeatable readings. Be sure the scale is leveled properly. Air currents can also diminish the scale’s performance. Avoid placing the scale in front of or directlyunder air vents. Other than items being weighed, keep the scale free from objects rubbing or pressing against theplatter.Contents of PackagingPackage contents for all DIVA units include: DIVA scale base Operation Manual Display Cable Tower included and attachment hardware (The optional display may be packed separately) Communication and Display cables (from scale to scanner) Sealing KitSetup1.2.Open the box, carefully remove the packing material, take all items out of the carton.Attach the display as described below, depending on which version of scale you ordered:For Price Computing Version:TowerPin attachment holesAttachment Screws (2)Connector of cableAttachment pins (2)Tower Mounting BracketTable surfaceAttachment wing nuts (2)A: Pull the connector of the cable through the holes ofthe table surface and tower mounting bracket;B: Put (2) screws through the (2) arch holes on thebracket and (2) holes on the table surface;C: Attach cover to the surface of table with (2) nuts.D: Connect the cable to the connector at the bottom ofthe tower displayE: Attach the base of the display to the mounting bracketby insuring that the (2) pins on the bracket areinserted in the holes of the base to attach the towerand snap the tower into place.for Attachment Screws6DIVA Operation Manual

METTLER TOLEDOFor Weigh Only Version:The Weigh Only version comes with a tower mount.Assemble the Weight Only tower as is illustrated here:DisplayDisplay CableDisplay BracketDisplay Tower2. Set the scale base on a sturdy, level surface. Level the scale by turning the adjustable feet on the bottom ofthe unit. Adjust the feet until the level bubble is in the center of the circle.Bubble indicator:CorrectWrong3. Put the platter on top of the DIVA scale base.4. Connect the tower display cable to the scanner.5. Attach the communications cables between the scanner and the POS.Power up sequenceNote: Before powering on the DIVA scale, always make sure there is nothing on the platter.Apply power to the scanner. The scale will go through a series of self-tests and then will proceed to normaloperating mode. The power-up sequence is as follows:1. All segments of the display characters are lit. This verifies operation of all segments;2. The scale displays the country code and GEO code, software part number and revision.3. The scale then captures zero and is ready for normal operation.DIVA Operation Manual7

METTLER TOLEDODisplay and KeyboardDisplayPrice Computing Version:8DIVA Operation Manual

METTLER TOLEDOWeight Only Version:KeyboardUsed to return the scale to gross zero if drifting should occur.Tare key.DIVA Operation Manual9

METTLER TOLEDOCursorsNETZeroLights when tare is entered.Lights when gross weight is zero.NETZERO10DIVA Operation Manual

METTLER TOLEDOOperationsWeighing and CommunicationPlace the item to be weighed on the platter, the weight will be displayed.Remote ASCII commands can control all other functions including data transfer, zero, and tare,depending on the protocol.Backlight functionDiva is equipped with a backlight for the display. To switch on the backlight, press and hold the“ZERO” key for about 3 seconds until the backlight turns on. Use the same procedure to switch thebacklight off.Re-zero functionThere are two ways to re-zero the scale:1. Power-up Zero2. Push button ZeroPower-up ZeroThe scale will automatically capture zero when it is turned on. The power-up zero capture rangeis /-10% of the scale capacity. When the scale is turned on with a weight on the platter ofmore than /-10% of the capacity, the scale will not capture zero (the weight display will show"-----") and the scale will not be ready for use. After removing the weight the scale will capture"zero".Push button ZeroThe ZERO key re-zeros the scale over a range of /-2% of the scale capacity. To use thisfunction, the scale must be in the gross weighing mode (NET cursor must be off) and in anon-motion condition. When the weight on the platter is more than /-2% of the scalecapacity, the depression of the zero key will not be accepted.Tare FunctionThe Tare Key allows you to subtract weight from the platter for items like containers that will be usedto hold the item being weighed.Place the empty container or wrapping material on the platter and Press the Tare Key.Place the item to be weighed in the container or on the wrapping material and onto the platter.Note: A Tare command can be sent from a POS through the Diva’s serial connection. Whatevermethod is used to start a transaction must continue to be used until the transaction is over. If thepush button is used first, a remote tare command will not work. Conversely, if a remote tare isused then the push button will not work until the transaction is complete and the scale has returnedto zero.DIVA Operation Manual11

METTLER TOLEDOSetupThis mode allows an operator to change certain soft switches directly from the keyboard.Press and hold thekey until “grP 1” and “CONF” is displayed. This will take about 8 seconds. Thescale is configurable for your specific needs with a special interactive set up procedure. In order to accessthe various prompts, you must utilize the following keys during the scale setup mode.This key is used to confirm the choice and then go to the next step.This key is used to step through the set up groups. Once a group is accepted, this key isused to select the soft switch settings12DIVA Operation Manual

METTLER TOLEDOSetup Soft SwitchesGroup.StepFunctionPossible SelectionsGroup 11.3BeeperON - Scale will “beep” when a key is pressed.OFF - No sound is made when a key is pressed.1.4Zero CursorON – Display zero cursor.OFF – Disable zero cursor.1.5Decimal pointON - .OFF - ,2.4Digital Filter Selection0 - Minimal1 – Low (Used for Normal use)2 - Medium3 – High (Used when there is lots of vibration)2.7Display (1 or 4 Line)0 – None1 – 1 Line2 – 4 Line2.8Display Update Rate0-100 – Adjust display rateGroup 2DIVA Operation Manual13

METTLER TOLEDOGroup.StepFunctionPossible SelectionsGroup 33.1Baud rate0 12001 24002 48003 96004 192005 384003.2Parity0 None1 Even2 Odd3.3Data0 7 data bit1 8 data bit3.4Bit stop0 None1 1 stop bit2 2 stop bitChose Protocol0 Disabled1 NCI-ECR (WO)2 (reserved)3 8217 Mettler-Toledo (WO)4 8213 Mettler-Toledo (WO)5 EPOS 1(WO)6 EPOS 2(WO)7 (reserved)8 Dialog 06 (PC)3.6Inter-character Delay0 – None1 – 1 ms 9 – 9 ms3.7Protocol OptionsFor NCI-ECR protocol,0 – 4 byte status reporting1 – 2 byte status reportingSave or abort settingSAVE save all setting and return to weighing modeABORT abort all setting and return to weighing mode4.1Weight Change00 - No Weight Change Requiredyy - 01 to 99 weight change divisions required4.2Return to Zero0 – No Return to Zero Required1 - Return to Zero ActiveSave or abort settingSAVE – save all settings and return to weighing modeABORT – abort all settings and return to weighing mode3.5SAVE9 Dialog 04/02 (PC)10 Extended Dialog 06 (PC)11 ICL (WO)12 Shekel (WO)13 RIVA 5462 (WO)14 IP3 (PC)15 (reserved)16 (reserved)Group 4EXITSAVE* PC - price computing version, WO - weigh only version.14DIVA Operation Manual

DIVA Operation Manual4.2 Return to Zero4.1 Weight ChangeGroup 43.7 Intercharacter Delay3.6 Protocol Options3.5 Protocol3.4 Stop Bit3.3 Data Bits3.2 Parity3.1 Baud RateGroup 32.8 Display Update Rate2.7 Display Type2.4 Digital FilterGroup 21.5 Decimal Point1.4 Zero Cursor1.3 BeeperGroup 1Function000001 (NCI)11 (8bits)0(none)5 (38.4kb)21 (1Line)2 (Low)On (.)OnOffWOUSAPC - Price Computing000000011 (NCI)0 (7bits)0 (7bits)11(even)8(Dialog06)3 (9.6kb)2(odd)223 (9.6kb)2 (Low)1 (1Line)1 (Low)Off (,)Off (,)2 (4Line)OnOffOnWOFranceOffPCGermany/(Europe)00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOn00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOWOSpain/Portug Berlguim/Polaland/EnglandWO - Weigh Only00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOAustria00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOItaly00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOKazachstan/Swiss00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOUkraine00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWORussia00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)On (.)OnOnWOHungary00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOSlovakia00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)Off (,)OffOnWOCzechia00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)On (.)OnOnWOGeneralExport00001 (NCI)10 (7bits)1(even)3 (9.6kb)21 (1Line)2 (Low)On (.)OnOnWOChina00001 (NCI)11 (8 bits)0 (none)5 (38.4kb)21 (1Line)2 (Low)On (.)OnOffWOCanadaMETTLER TOLEDOSoft Switches – Default Settings15

METTLER TOLEDOAppendixErrorsThe Diva will display an error message if a scale problem or incorrect keyboard entry is sensed. The errorcodes are:E 11RAM errorE 16ROM errorE 18EEPROM errorE 20Calibration errorCycle power to the scale and restart calibration.E 28Transmission ErrorReset ScalennnnnnIn weight displayOver capacitynnnnnnin total price displayOver 9999.99Remove weight from Platter, if that does not work trycycling the power to the scale. For continued problemscall METTLER TOLEDO for replacement.uuuuuuIn weight displayUnder zeroCycle power to the scale. For continued problems callMETTLER TOLEDO for replacementPlace the platter on the scale. Either press the Zero Keyor cycle power to the scale. For continued problemscall METTLER TOLEDO for replacement.Cleaning and Maintenance Remove power by removing the line cord or transformer from the wall outlet.Use a clean, damp cloth to wipe the exterior surfaces.DO NOT use solvents and chemicals to clean the unit.DO NOT attempt to remove the cover or perform service or maintenance on the internal parts of thescale.Excess liquids spilled onto the scale should be removed and the scale cleaned immediately.SpecificationsCapacityDivisionsWeight displayUnit price displayTotal price displayTare displayOperating temperatureStorage temperaturePlug in Power supply: 15 and 6kg Multi-Interval: 5 and 2 grams Multi-Interval: 5 digits: 6 digits (price computing version only): 6 digits (price computing version only): 4 digits (price computing version only): -10 C to 40 C: -25 C to 50 C: Power supplied via scanner power supplySpecifications are subject to change without notice.16DIVA Operation Manual

METTLER TOLEDOAccessoriesCIMFDescription71208240VIVA Wall Mount Display AccessoryCall your localMT SalesRepresentativeWeight Only Dual Display KitDIVA Operation ManualIllustration17

METTLER TOLEDO1900 Polaris ParkwayColumbus, Ohio 43240-2020P/N: 72191203METTLER TOLEDO is a Trademark of Mettler-Toledo, LLC 2012 Mettler-Toledo, LLC

DIVA Operation Manual 1 Introduction Please read this instruction manual carefully. This manual is intended for use with all Diva Weigh Only and Price Computing scales. The Diva scale is combined with a scanner for full featured Checkout applications. The Diva scale is a high precision weighing instrument.

Related Documents:

Mettler XS6001S Top loading Balance /Lote de 2 balanzas Mettler Toledo y una pantalla 59 Mettler Toledo ID7 Platform Scale / 60 Mettler Toledo D-7470 Platform Scale With ID7 Display /Balanza Mettler todledo con Pantalla ID7 61 Mettler Toledo Model IND429 Platform Scale /Balanza de piso Mettler Toledo Modelo IND429

Jul 13, 2020 · FTP Client–automatic data transferApplies to DT8x and DT800 9 Mettler Toledo MT-SICS 9 Mettler Toledo IND226 Load indicator and Version 9.08 firmware and latter9 Mettler Toledo PG-S top loader balance 9 Egg Buddy 10 Program 1, Heart Wave Form Monitor 10 Program 2, Heart Rate Monitor 12 Ca

Весы Mettler Toledo серии ME — наи-более бюджетная линейка аналити-ческих ипрецизионных весов Mettler Toledo, предназначен

METTLER TOLEDO DL50/DL53/DL55/DL58 3 Introduction 1. Introduction The METTLER TOLEDO DL50, DL53, DL55 and DL58 Titrators are microprocessor con-trolled analytical instruments which supply accurate and reproducible results thanks to their built-in intelligence. You can use the titrators to perform end point, equivalence point and pH-stat .File Size: 474KB

METTLER TOLEDO MTWI Marketing, 614-438-4302, for information. METTLER TOLEDO reserves the right to make refinements or changes to the product or manual without notice. U.S. Government Restricted Rights L

2016 TOLEDO AIR MONITORING SITES Map/AQS # Site Name PM 2.5 PM 10 O 3 SO 2 CO NO 2 TOXICS PM 2.5 CSPE MET. 1. 39-095-0008 Collins Park WTP X . Agency: City of Toledo, Environmental Services Division Primary QA Org.: CCity of Toledo, Environmental Services Division MSA: Toledo Address: st2930 131 Street Toledo, Ohio 43611 .

Mettler-Toledo Bold 8 pt AGCC 8 pt Line spacing 10 pt Vertical line 0.5 pt FaxSubject to technical changes 41-44-944 30 60 Subject to technical changes 04/2009 Mettler-Toledo GmbH Printed in Xxxxxxxxxxxx For more information Service Benefits Installation & Setup Prop

SAVE this manual for future reference. DO NOT allow untrained personnel to operate, clean, inspect, maintain, service, or tamper with this equipment. ALWAYS DISCONNECT this equipment from the power source before cleaning or performing maintenance. CALL METTLER TOLEDO for parts, information, and service.