Ferrule fuse-links 10x38 gG 400 to 690VACIEC Cylindrical Fuse-LinksMersen aM and gG fuse-links cover a wide range of physical sizes and ampereratings for 400, 500, and 690VAC for protection in electrical distribution circuitsand various industrial applications. Most ratings are available in size 8x31 and size10x38 with an optional indicator, and in size 14x51 and 22x58 with an optionalstriker to activate an auxiliary contact. Size 10x38 is also available with striker. Allcylindrical fuse-links have ceramic bodies and silver-plated contacts.Cylindrical fuse-links “gG” are used for the protection of cables, motors andLV-networks. They limit and cut off unacceptable overcurrents and short-circuitcurrents up to their nominal breaking capacity. Cylindrical fuse-links “gG” alsoprotect electrical equipment and installations against the dynamic effect of highshort-currents.Our technology and process was designed to ensure highly reliable technicalperformance.Features BenefitszzzzzzzzReduced sizeFull range protectionVisual indication of fuse operationSafest and most reliable protection systemStandardsApplicationszz gG type for protection of line, cable against overload and short circuit in variousindustrial application and electrical distribution circuits.IEC 60269-1 & -2 (electrically onlyfor the range with striker)Approved by Lloyd’s Register ofShipping and Bureau VeritasVoltage Range AC400 . 690 VACAmpere Range (A)0.5 . 32 ASpeed/Characteristic gGI.R. AC (kA)120 kABody MaterialCeramicContact MaterialsSilver plated copperProduct Size10x38 mmLow Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Technical data overview1

Ferrule fuse-links 10x38 gG 400 to 690VACProduct rangeSize 10,3x38 400/500VAC without indicatorCatalognumberFR10GG50V0.5Reference Rated voltage ACRated breakingRated current Innumber(IEC)capacity ACPower dissipationat InWeightFR10GG50V0.5 C211027500 V0.5 A120 kA0.07 W8.3 gFR10GG50V1B212061500 V1A120 kA0.45 W8.3 gFR10GG50V2D213098500 V2A120 kA0.5 W8.3 gFR10GG50V4X213598500 V4A120 kA0.85 W8.3 gFR10GG50V6K215128500 V6A120 kA0.95 W8.3 gFR10GG50V8D217169500 V8A120 kA1.15 W8.3 gFR10GG50V12W219761500 V12 A120 kA1.4 W8.3 gFR10GG50V10S218194500 V10 A120 kA1.3 W8.3 gFR10GG50V16G200750500 V16 A120 kA1.9 W8.3 gFR10GG50V20D211028500 V20 A120 kA2.4 W8.3 gFR10GG50V25E213099500 V25 A120 kA2.7 W8.3 gFR10GG40V32A214107400 V32 A120 kA2.8 W8.3 gFR10GG50V2ICatalognumberReference Rated voltage ACnumber(IEC)Rated current InRated breakingcapacity ACPower dissipation at InWeightFR10GG50V2IS2166532A120 kA0.5 W8.3 g500 VFR10GG50V4IE217170500 V4A120 kA0.85 W8.3 gFR10GG50V6IT218195500 V6A120 kA0.95 W8.3 gFR10GG50V8IV219231500 V8A120 kA1.15 W8.3 gFR10GG50V10I E222207500 V10 A120 kA1.3 W8.3 gFR10GG50V12I H200751500 V12 A120 kA1.4 W8.3 gFR10GG50V16I H201809500 V16 A120 kA1.9 W8.3 gFR10GG50V20I X211551500 V20 A120 kA2.4 W8.3 gFR10GG50V25I W212585500 V25 A120 kA2.7 W8.3 gFR10GG40V32I Z213600400 V32 A120 kA2.8 W8.3 gSize 10,3x38 250/400VAC with strikerCatalognumberReference Rated voltagenumberAC (IEC)Rated current InRated breakingcapacity ACPower dissipationat InWeightFR10GG40V2PG083703400 V2A100 kA0.6 W9.2 gFR10GG40V4PD084758400 V4A100 kA0.75 W9.2 gFR10GG40V6PY084799400 V6A100 kA0.9 W9.2 gFR10GG40V8PF083955400 V8A100 kA1W9.2 gFR10GG40V10P A084801400 V10 A100 kA1.1 W9.2 gFR10GG40V12P G083956400 V12 A100 kA1.25 W9.2 gFR10GG40V16P X084798380 V16 A100 kA1.35 W9.2 gFR10GG40V20P Z084800380 V20 A100 kA1.45 W9.2 gFR10GG25V25P H083957250 V25 A100 kA1.7 W9.2 gFR10GG25V32P E083954250 V32 A100 kA2.2 W9.2 gLow Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Size 10,3x38 400/500VAC with indicator2

Ferrule fuse-links 10x38 gG 400 to 690VACProduct rangeCatalognumberReference Rated voltage ACRated breakingRated current Innumber(IEC)capacity ACPower dissipationat InWeightFR10GG69V1R3027870.45 W9g690 V1A120 kAFR10GG69V2S302788690 V2A120 kA0.55 W9gFR10GG69V4T302789690 V4A120 kA0.6 W9gFR10GG69V6V302790690 V6A120 kA0.9 W9gFR10GG69V8W302791690 V8A120 kA1W9gFR10GG69V10 X302792690 V10 A120 kA1.15 W9gFR10GG69V12 Y302793690 V12 A120 kA1.4 W9gFR10GG69V16 Z302794690 V16 A120 kA1.9 W9gLow Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Size 10,3x38 690VAC without indicator3

Ferrule fuse-links 10x38 gG 400 to 690VACTime current characteristic curvesSize 10x38 500V gG without striker1000070005000Actual pre-arcing time (s)3000200010007005000.5 0.0003RMS value of prearc current (A) /- 8%Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 310.000120.0002MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.0.34

Ferrule fuse-links 10x38 gG 400 to 690VACTime current characteristic curvesSize 10x38 500V gG without striker1000070005000Actual pre-arcing time (s)3000200010006A7005008A30020010 A100705012 A302016 A10720 A53225 .0020.0010.00070.00050.0003RMS value of prearc current (A) /- 8%Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 30201075310.000120.0002MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.0.35

Ferrule fuse-links 10x38 gG 400 to 690VACTime current characteristic curvesSize 10x38 400V gG without striker1000070005000Actual pre-arcing time (s)30002000100070050030020032 10.0070.0050.0030.0020.0010.00070.00050.0003RMS value of prearc current (A) /- 8%Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 300200100705030200.0001100.0002MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.0.36

Ferrule fuse-links 10x38 gG 400 to 690VACTime current characteristic curvesSize 10x38 690V gG without striker1000070005000Actual pre-arcing time (s)300020001A10007002A5003004A2001006A7050308A2010 A107512 A3216 .0020.0010.00070.00050.0003RMS value of prearc current (A) /- 8%Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 310.000120.0002MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.0.37

Ferrule fuse-links 10x38 gG 400 to 690VACTime current characteristic curvesSize 10x38 400V gG with striker10000700050003000Actual pre-arcing time (s)200010007005003002002A10070504A306A2010758A310 A212 A10.70.50.220 .00070.00050.0003RMS value of prearc current (A) /- 8%Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 0.00011000.0002MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.16 A0.38

Ferrule fuse-links 10x38 gG 400 to 690VACTime current characteristic curvesSize 10x38 250V gG with striker1000070005000Actual pre-arcing time (s)30002000100070050030020010070503025 050.0030.0020.0010.00070.00050.0003RMS value of prearc current (A) /- 8%Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 010070503020100.0001100000.0002MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.32 A0.39

Ferrule fuse-links 10x38 gG 400 to 690VACCurrent limiting diagramSize 10x38 500V gG without striker30004A2000lm 2.3 lpMaximum peak let thru current (Ic)(A)10002A7005001A3000.5 A20010070503020101e 710532517Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.50 Hz RMS symetrical prospective current (Ip)(A)10

Ferrule fuse-links 10x38 gG 400 to 690VACCurrent limiting diagramSize 10x38 500V gG without striker100007000lm 2.3 lp25 A20 A16 AMaximum peak let thru current (Ic)(A)5000300012 A10 2007010050503070Size 10x38 400V gG without striker10000lm 2.3 lp70003000200010001e 001000050 Hz RMS symetrical prospective current (Ip)(A)Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 0200700100Maximum peak let thru current (Ic)(A)5000MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.50 Hz RMS symetrical prospective current (Ip)(A)11

Ferrule fuse-links 10x38 gG 400 to 690VACCurrent limiting diagramSize 10x38 690V gG without striker300016 A12 A10 A8A6A4A2A2000Maximum peak let thru current (Ic)(A)lm 2.3 020010070503020710510320Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.50 Hz RMS symetrical prospective current (Ip)(A)12

Ferrule fuse-links 10x38 gG 400 to 690VACCurrent limiting diagramSize 10x38 400V gG with striker1000070005000Maximum peak let thru current (Ic)(A)20 Alm 2.3 lp16 A12 A300010 000700500300200701005030201010100020Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.50 Hz RMS symetrical prospective current (Ip)(A)13

Ferrule fuse-links 10x38 gG 400 to 690VACCurrent limiting diagramSize 10x38 250V gG with striker10000lm 2.3 lp700032 A25 A3000200010007005003001e ximum peak let thru current (Ic)(A)500050 Hz RMS symetrical prospective current (Ip)(A)Size 10x38 500V gG without striker7050500V290V30pre-arcing I²tPre-arcing and clearing I²t (A²s)2010753210,70,50,30,20,14A2A1A0,050.5 A0,07Rated current (A)Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Pre-arcing and operating I2t characteristics14

Ferrule fuse-links 10x38 gG 400 to 690VACPre-arcing and operating I2t characteristicsSize 10x38 500V gG without striker30002000500V290VPre-arcing and clearing I²t (A²s)pre-arcing I²t100070050030020010070503025 A20 A16 A12 A8A6A1010 A20Rated current (A)Pre-arcing and clearing I²t (A²s)100007000400V230V5000pre-arcing I²t30002000100070050030020032 A100Rated current (A)Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Size 10x38 400V gG without striker15

Ferrule fuse-links 10x38 gG 400 to 690VACPre-arcing and operating I2t characteristicsSize 10x38 690V gG without striker1000700500300690V400Vpre-arcing I²tPre-arcing and clearing I²t (A²s)2001007050302010753210,70,516 A12 A10 A8A6A4A2A1A0,3Rated current (A)Size 10x38 400V gG with striker3000400V250Vpre-arcing I²tPre-arcing and clearing I²t (A²s)20001000700500300200100705030Rated current (A)Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.com20 A16 A12 A8A6A4A2A1010 A20MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.500016

Ferrule fuse-links 10x38 gG 400 to 690VACPre-arcing and operating I2t characteristicsSize 10x38 250V gG with striker10000700030002000100070050030020025 A10032 APre-arcing and clearing I²t (A²s)5000250Vpre-arcing I²tRated current (A)DimensionsSize 10x38 gG without indicatorSize 10x38 gG with indicator(1001210)(1002537) 0.2010.110.1Ø 10.2Dimensions in mmDimensions in mmLow Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.com 0.20MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Ø 10.238 0.638 0.610.110.1Visual indicator17

Ferrule fuse-links 10x38 gG 400 to 690VACDimensionsSize 10x38 gG with striker(33907)10Striker1039.2 138.2 0.7Ø 10.3 0.1Low Voltage IEC Fuses / DS-LFCY10GG-06-1115 ENwww.ep.mersen.comMERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.Dimensions in mm18

IEC 60269-1 & -2 (electrically only for the range with striker) Approved by Lloyd’s Register of Shipping and Bureau Veritas Technical data overview Voltage Range AC 400 . 690 VAC Ampere Range (A) 0.5 . 32 A Speed/Characteristic gG I.R. AC (kA) 120 kA Body Material Ceramic Contact Materials Silver plated copper Product Size 10x38 mm-LFC10 .

Related Documents:

CHAPTER 10 STAINLESS STEEL COMPONENTS 406 PRODUCT CATALOGUE STAINLESS STEEL COMPONENTS STAINLESS STEEL PAGE FERRULES 4200-07-S Ferrule EN1SC 409 4200-04-S Ferrule EN2SN 409 4200-01-S Ferrule EN1SN, 2SC 409 4200-02-S Ferrule EN2SN 409 4200-26-S Ferrule P.T.F.E/TEFLON smooth 409 4200-15-S Ferrule R7/R8 409 4200-30-S Ferrule P.T.F.E/TEFLON 409

23 24 25 38 (Exemptions) January 23, 2019 . Title 14 California Code of Regulations . Division 1.5, Chapter 4 . Subchapter 7, Article 2 . Amend §§ 1038, 1038.2, & 1038.2; Adopt §§ 1038.3, 1038.4, & 1038.5 § 1038. Exemption. Persons who conduct the following types of Timber Operations conducted pursuant to this section are

600 x 300 350 1260 50 6 14 600 x 300 669 2409 50 21 9 600 x 300 1137 4094 50 60 6 600 x 300 1750 6300 50 142 5 400 x 400 400 1440 50 9 12 400 x 400 674 2425 50 27 8 400 x 400 1170 4212 50 80 6 400 x 400 1750 6300 50 179 4 500 x 400 360 1296 50 5 15 500 x 400 715 2574 50 19 9 500 x 400 1330 4787 50 66 6 500 x 400 1800 6480 50 122 5 600 x 400 450 1620 50 5 15 600 x 400 958 3448 50 24 9 600 x 400 .

The basic Double-Ferrule Tube Fitting is a four-piece fitting consisting of the nut, back ferrule, front ferrule and the body. When installed, it becomes a five-piece connection with the addition of the tubing to provide a solid lea

2.ut the ferrule and hose together by hand until the hose reaches the bottom of the ferrule. P 3. Push the nipple of the hose fitting into the hose by hand or by using an assembly unit. Push until the flange of the hose fitting stops against the ferrule (the fitting will push the hose out of the ferrule some millimetres).

250 250 300 300 300 300 300 400 400 400 400 400 400 400 400 400 400 400 500 500 500 500 . Stainless steel enclosure for IP66/NEMA-4X Made of stainless steel up to 2mm thickness, 316L grade or equivalent . chemical or food industries and places where hygiene is necessary Highly polished SS

POWERSTAR HQI-T 400/N 400 W E40 42 000 lm MASTER HPI-T Plus 400W/645 400 W E40 35 000 lm RLF/400 HST VIALOX NAV-T 400 SUPER 4Y 400 W E40 56 500 lm SON-T Comfort 400W/621 400 W E40 38 000 lm VIALOX NAV-T 400 4Y 400 W E40 48 000 lm VIALOX NAV-T 400 400 W E40 48 000 lm RLF 500 IQT - - - - HalogenA IDE 500 W E40 10 250 lm RLF 300 IQL

security rules for protecting EU classified information, certain provisions in this guide are still based on Commission Decision 2001/844. In the absence of new guidelines they should continue to be applied. Under the new security rules, all classification markings must now be written in FR/EN format (e.g. RESTREINT UE/EU RESTRICTED). EU grants: H2020 Guidance — Guidelines for the .