TEST & MEASUREMENTCATALOGUEWWW.IDEALIND.COM

For over 90 years, IDEAL INDUSTRIES, INC. has been enhancing the productivity and safety ofelectricians who test, measure, or troubleshoot electrical systems. In 2021 we released a newline of testers with the professional electrician in mind. See our new additions in this catalog.CIRCUIT TRACERS. 2- 4CIRCUIT BREAKER FINDERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6CIRCUIT ANALYZER.7-8CLAMP / FORK METERSClamp Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 1 4Fork Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 - 1 4DIGITAL MULTIMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5 - 1 8VOLTAGE / CONTINUITY TESTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 9 - 2 0RECEPTACLE TESTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 - 2 2NON-CONTACT VOLTAGE TESTERS. . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 - 2 5INFRARED THERMOMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6SPECIALTY TESTERS3-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 - 2 8Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 - 2 8Ground Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 - 2 8Digital Light Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 - 2 8ACCESSORIESTest Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 9 - 3 0Carrying Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2Scan with yoursmartphone to see avideo and learn moreWWW.IDEALIND.COM

SURETRACE CIRCUIT TRACERYour IDEAL troubleshooting solution. Designed to find everything,while saving you time and money.Scan with yoursmartphone to see avideo and learn moreKIT OPTIONS AND PARTSKIT OPTIONS61-959INDIVIDUAL COMPONENTSRC-959Receiver withSuper-BrightOLED DisplayRC-955Receiver withRed LED DisplayTR-955TransmitterRated for Use onCircuits from0 to 600V AC/DC61-95761-955Receiver with Super-Bright OLEDRotating Display (90 increments)and inductive clamp and battery packReceiver with Super-Bright OLEDRotating Display (90 increments)Receiver with Rotating RedLED Display (180 increments)61-95961-95761-955 ——— —— Sold SeparatelySold SeparatelySold SeparatelyIC-958 BP-958Inductive Clamp andBattery PackFor use on 0 to 120Vcircuits carrying lessthan 5 Amps.TL-956Test LeadSetCR-959Cradle for RC-959 andRC-955 ReceiversWWW.IDEALIND.COM 2

CIRCUIT TRACER RECEIVERS FEATURESSuper BrightOLED DisplayRed LEDDisplayExclusive Rotating Display90 Increments (RC-959)180 Increments (RC-955)Low Battery IndicatorFour Levels of SensitivityRC-959RC-955600VFinds Opens0-600V AC or DC Lead Set included.3 WWW.IDEALIND.COMAudible IndicationFinds Conductorsin Walls, Ceilings and FloorsFinds Dead Shorts

CIRCUIT TRACER TRANSMITTER FEATURESCertainCircuit After the correct breaker has been identified andtripped, the transmitter senses the loss of powerand sends a different signal back to the receiver atthe panel to give the user confidence that the rightcircuit has been de-energized.CertainCircuit (TR-955)EnergizedDe-energizedInductive Clampfor when direct contactwith alligator clips is notpossibleTraces de-energizedcircuitsTR-955600V23164Inductive Clamp & Battery PackCradle(For use on circuits carrying up to 120V ACw/less than 5 Amps)(For use on RC-955& RC-959 Receivers)IC-958 BP-958CR-9595Tracer Test Lead SetTL-956 (includes the following)1. 3 Ft. Lead Adapter forTransmitter (set of 2)2. 25 ft. Lead Adapter forTransmitter3. Alligator Clips (set of 2)4. Blade Prongs5. Prong for Lead Adapters6. Outlet Plug Adapter forTransmitterWWW.IDEALIND.COM 4

CIRCUIT BREAKERFINDERSFEATURESScan with yoursmartphone to see avideo and learn moreGFCI TripNon-Contact VoltageTesterLED IndicatorsAudible TonePolarity & Live CircuitIndication61-534300VLead Adapter KitProvides adapters for use in lighting fixtures.5 WWW.IDEALIND.COM61-532Live Circuit Indication300VTL-532ATest Lead & Adapter Kit

CIRCUIT BREAKER FINDER SPECIFICATIONS61-534TransmitterTriple Function - SignalTransmitter, Polarity Indicator &GFCI Receptacle Tester61-534ReceiverDual Function Non-Contact VoltageTester & Breaker Finder61-532Transmitter61-532ReceiverNEWCIRCUIT BREAKER FINDER SELECTION GUIDETRANSMITTER FEATURESCAT Rating (Safety)ListingLine VoltageSupply Frequency61-53461-532CAT II 300VCAT II 300VUL 1436UL 1436Line Powered(120V AC only)Line Powered(120V AC only)47-63Hz47-63Hz50g (approx.)50g (approx.)18A (approx.) @ 120V18A (approx.) @ 120V4mS every 17ms(@ 60Hz)4mS every 17ms(@ 60Hz)200mW max. @ 120V AC200mW max. @ 120V32 - 122 F (0 to 50 C)32 - 122 F (0 to 50 C) —Auto Power Off (after 10 mins. of no activity) Battery Type9V9V0.2 lbs. (w/o battery)0.2 lbs. (w/o battery)2-Year*2-Year*TL-532ATL-532AWeightPulse AmplitudePulse RatePower ConsumptionOperating TemperatureGFCIPolarity Indication—RECEIVER FEATURESVisual and Audible IndicatorsLow Battery IndicationWeightWarrantyACCESSORIESLight Socket and 3-prong to 2-prong Adapters, Alligator ClipsSpecifications are subject to change without notice.WWW.IDEALIND.COM 6

SURETESTCIRCUIT ANALYZERFEATURESScan with yoursmartphone to see avideo and learn more61-164Circuit AnalyzerDisplays Voltage Dropat 12, 15 & 20 AmpsDisplays Impedanceof hot, neutral & groundDisplays H N GpolarityDetects and Displaysfalse or "bootleg" ground300VDisplaysneutral to ground voltageTrips GFCIat 6mA or 30mATrue RMSLine Voltage7 WWW.IDEALIND.COMEstimated Loadon Line in Amps

CIRCUIT ANALYZER SPECIFICATIONSSURETEST CIRCUIT ANALYZER SPECIFICATIONS61-164DescriptionRange &ResolutionAccuracyTRANSMITTER FEATURESCAT Rating (Safety)ListingCAT III 300V—cULus—AC Voltage (Note: The 61-164 is protected to 265V AC but shouldbe unplugged immediately if plugged into a mis-wired outlet. It isintended for use on 120V AC circuits only.) Do not press any buttons.—85.0 – 265.0 VAC(Unplug if 240V ACis displayed andcorrect wiring.)1.0%Frequency—45.0 – 65.0 Hz1.0%Impedance—0.00 - 3.00 Ω5.0%Neutral Ground Voltage—0.0 - 24.0V AC2.0%% Voltage Drop 12A, 15A, 20A Load Tests—0.1% - 50.0%5.0%GFCI mA Trip Level & Time to Trip in Milliseconds—6.0 - 9.0 mA0.0 - 6500 mS2.0%Warranty2-Year*—Part No.ACCESSORIESGround Continuity Adapter (For checking grounding of cabinets, etc.)61-175Isolated Ground Adapter (For determining whether receptacle has anisolated ground.)61-176Alligator Clip Adapter (For connection to circuits other than outlets.)61-1831’ Extension Cord (included)61-182Nylon Carrying Case (included)61-179IMPORTANT: This circuit analyzer is intended for use by qualified electricians. Follow the NFPA 70E Standard for Electrical Safety in the Workplace when usingthis tester. Always consult the instruction manual provided with the tester for operational limitations and procedures associated with a specific tester.Specifications are subject to change without notice.61-183Alligator Clip Adapterfor 61-164Circuit Analyzer61-175Ground ContinuityAdapter for 61-164Circuit Analyzer61-176Isolated GroundAdapter for 61-164Circuit Analyzer61-1821’ Extension Cordfor 61-164Circuit AnalyzerWWW.IDEALIND.COM 8

CLAMP/FORK METER VS. MULTIMETERSafety - A fork meter allows you to measure AC or DCcurrent (depending on the model) by positioning thefork around a conductor, which is much safer thanmaking direct contact with a live circuit.Safety - A clamp meter allows you to measure AC orDC current (depending on the model) by positioningthe clamp jaw around a conductor, which is muchsafer than making direct contact with a live circuit.Productivity - During a measurement, it is notnecessary to shut off the circuit carrying current, whichimproves productivity.Productivity - During a measurement, it is notnecessary to shut off the circuit carrying current,which improves productivity. This allows isolation of aconductor being tested in a bundle of conductors.Limited to 200A AC/DC MeasurementLimited to 2000A AC/DC Measurement (Hard Clamp)No Fuse Protection requiredNo Fuse Protection requiredMultimeters measure current differently than a fork orclamp meter. To measures current with a multimeter:Switch You must insert the multimeter into the circuit toget the current to flow THROUGH the meter andare making direct contact with the live circuit.To properly conduct a current measurement inaccordance with Electrical Safety-related WorkPractices (ESWP) you must:Battery(Power Source)Light Bulb(Load)Red LeadBlack Lead de-energize the circuit, disconnect the circuit, insertthe meter into the circuit, re-energize the circuit totest current AND THEN repeat the whole process again to“remove” the meter from the circuit after the test.Limited to 10A AC/DC MeasurementFuse Protection required (due to current passthrough)9 WWW.IDEALIND.COM

TIGHTSIGHT CLAMP METERSPatented TightSight Backlit Displayeliminates need to bend or twistconductors or place your head near orin the panel and allows you to easilyread the bottom display when taking allmeasurements.Scan with yoursmartphone to see avideo and learn moreNon-Contact Voltage TesterScreen displaysElectromagnetic Field (EF)FlashlightBuilt-In Probe Tip HolderUniversal Magnetic Strap ClipOvermolded Industrial Grip2M Drop (model specific)61-757 61-747TightSight EndDisplayBacklit Displays600V1000VWWW.IDEALIND.COM 10

FORK METERSFEATURESNon-Contact VoltageIndicationBuilt in Clamp Tip0.75 in. (19mm)Jaw OpeningFlashlight/BacklightProbe Storage& Lead Holders(on back)Delta(difference fromoriginal reading)Max./Min.61-415Patented TightSight Backlit Display eliminates needto bend or twist conductors orplace your head near or in thepanel and allows you to easilyread the bottom display whentaking measurements600V11 WWW.IDEALIND.COM1000V

TIGHTSIGHT CLAMP METERS61-7751000A AC/DCClamp MeterTightSight w/BacklightCAT IV 600V CAT III 1000V61-765660A AC/DCClamp MeterTightSight w/BacklightCAT IV 600V CAT III 1000V61-757600A AC/DCClamp MeterTightSight w/Backlight& FlashlightCAT IV 600V CAT III 1000VCONVENTIONAL CLAMP METERS61-747400A AC/DCClamp MeterTightSight w/Backlight& FlashlightCAT III 600VCLAMP METER ACCESSORIESTL-757Test Leadsw/Alligator Clips61-744400A AC Clamp Meter4000 Count & FlashlightCAT III 600V61-737400A AC Clamp Meter4000 Count w/BacklightCAT III 600V61-415200A AC/DCSplit Jaw MeterTightSight w/Backlight& FlashlightCAT IV 600V CAT III 1000V61-405200A AC Split Jaw Meterw/Backlight & FlashlightCAT III 600VTC-757ThermocoupleUMHS-757Universal MagneticHanging StrapC-757Nylon Carrying CaseIMPORTANT: The clamp meters on this page are intended for use by qualified electricians. Follow the NFPA 70E Standard for Electrical Safety in the workplacewhen using this tester. Always consult the instruction manual provided with the tester for operational limitations and procedures associated with a specific tester.WWW.IDEALIND.COM 12

CLAMP METER SPECIFICATIONSNEWNEWCLAMP METERSELECTION GUIDE61-77561-76561-75761-747CAT IV 600VCAT III 1000VCAT IV 600VCAT III 1000VCAT IV 600VCAT III 1000VCAT III 600VcULus, CE, RCMcULus, CE, RCMcULus, CE, RCMcULus, CE, RCMFEATURESCAT Rating (Safety)ListingDrop ProtectionClamp/Jaw Opening6.6 ft. (2m)6.6 ft. (2 m)1.4 in. (35.5mm)1.4 in. (35.5mm)600V2.0 in. (50.8mm)1.5 in. (38mm)AC Voltage (Volts)750V750V600VDC Voltage (Volts)750V750V1000V600VAC Current (Amps)1000A660A600A400ADC Current (Amps)1000A660A600A400AOhms (Resistance)999.9Ω999.9Ω60MΩ40MΩAC Millivolts——60004000DC Millivolts——60004000 ——True RMSHigh Voltage AlarmAudible ContinuityVisual ContinuityBacklightTemperature ACV/DCV 30VACV/DCV 30V -40 F 1832 F-40 C 1000 C-40 F 1832 F-40 C 1000 CLow Impedance (LoZ)——Yes—NCV——40-600V40-600VAuto Ranging 6.000mF4.000mF10Hz 9.999KHz10Hz 9.999KHz 444 3 x 1.5V AAARange Hold——Data Hold RelativeDiode Test——Capacitance TestMax / Min Magnetic Strap Mount——Test Probe Holder——Flashlight——Auto-Power Off (APO) 444 1 x 9 Volt1 x 9 Volt3 x 1.5V AAAFrequency / Duty CycleAPO DisableLow Battery IndicationBattery Type edIncludedIncludedIncludedBottom LCD DisplayLCD Display CountWarrantyACCESSORIESLeads & Alligator ClipsSpecifications are subject to change without notice.13 WWW.IDEALIND.COM

CLAMP METER SPECIFICATIONSNEWNEWNEWCLAMP METERSELECTION GUIDE61-74461-73761-41561-405CAT III 600VCAT III 600VCAT IV 600VCAT III 1000VCAT III 600VcULus, CE, RCMcULus, CE, RCMcULus, CE, RCMcULus, CE, RCM3.3 ft. (1m)6.6 ft. (2m)3.3 ft. (1m)1.45 in. (36.5mm)1.4 in. (35.5mm)0.75 in. (19mm)0.75 in. (19mm)AC Voltage (Volts)600V600V10001000DC Voltage (Volts)600V600V10001000AC Current (Amps)600A400A200200DC Current (Amps)——200—Ohms (Resistance)FEATURESCAT Rating (Safety)ListingDrop ProtectionClamp/Jaw Opening40MΩ40MΩ60MΩ60MΩAC Millivolts—4000DC Millivolts—4000True RMS— High Voltage Alarm—ACV/DCV 30VACV/DCV 30VACV/DCV 30VAudible Continuity Visual Continuity—Backlight— Temperature—-40 F 1832 F-40 C 1000 C——Low Impedance (LoZ)————70-600V40-600V40-600V40-600VData Hold Relative—Diode Test— Capacitance Test—400.0µF6.000mF6.000mFFrequency / Duty Cycle—10Hz 9.999KHz——Max / Min—Magnetic Strap Mount—Test Probe Holder— Flashlight——Auto-Power Off (APO) APO Disable—— 2 x 1.5V AAANCVAuto RangingRange HoldLow Battery IndicationBattery TypeBottom LCD DisplayLCD Display CountWarranty 2 x 1.5V AAA3 x 1.5V AAA2 x 1.5V AAA—— ds SORIESLeads, Case & BatteriesThermocoupleSpecifications are subject to change without notice.WWW.IDEALIND.COM 14

MULTIMETER VS. CLAMP/FORK METERSafety - A fork meter allows you to measure AC orDC current (depending on the model) by positioningthe fork around a conductor, which is much saferthan making direct contact with a live circuit.Safety - A clamp meter allows you to measure AC orDC current (depending on the model) by positioningthe clamp jaw around a conductor, which is much saferthan making direct contact with a live circuit.Productivity - During a measurement, it is notnecessary to shut off the circuit carrying current,which improves productivity.Productivity - During a measurement, it is not necessaryto shut off the circuit carrying current, which improvesproductivity. This allows isolation of a conductor beingtested in a bundle of conductors.Limited to 200A AC/DC MeasurementNo Fuse Protection requiredLimited to 2000A AC/DC Measurement (Hard Clamp)No Fuse Protection requiredMultimeters measure current differently than a fork orclamp meter. To measures current with a multimeter:Switch You must insert the multimeter into thecircuit toget the current to flow THROUGH the meter and aremaking direct contact with the live circuit.To properly conduct a current measurement inaccordance with Electrical Safety-related WorkPractices (ESWP) you must: de-energize the circuit, disconnect the circuit, insertBattery(Power Source)the meter in the circuit, re-energize the circuit totest current AND THEN repeat the whole process again to“remove” the meter from the circuit after the test.Limited to 10A AC/DC MeasurementFuse Protection required (due to current passthrough)15 WWW.IDEALIND.COMLight Bulb(Load)Red LeadBlack Lead

DIGITAL MULTIMETERSFEATURESNon-ContactVoltage TesterBuilt inNon-ContactVoltage, High Voltage,Visual Indications,Augment Audible Indication(61-357, 61-347, 61-337)Backlit Display(all models)Probe Holder StorageAll ModelsTemperature(61-357, 61-347, 61-337)Removable BootAll ModelsFUSE Notification(61-357, 61-347, 61-337)Universal MagneticStrap ClipAll ModelsLEAd Warning(61-357, 61-347, 61-337)Bar Graph(61-357 only)WWW.IDEALIND.COM 16

DIGITAL MULTIMETERS61-34761-3571000V Auto Range TRMS6000 Count Display Multimeter w/NCVT, Temp, Bar Graph & LoZCATIV 600V CATIII 1000V600V1000V Auto Range TRMS6000 Count DisplayMultimeter w/NCVT, & TempCAT IV 600V CAT III 1000V1000V61-337600V Auto RangeMultimeter w/NCVT & TempCATIII 600V61-327600V Manual RangeMultimeter w/ NCVT CATIII 600V600VACCESSORIESTL-757Test LeadsF-11A-347357Fuse for 61-357 & 61-347UMHS-757TC-757Universal MagneticHanging StrapF-600mA-347357Fuse for 61-357 & 61-347ThermocoupleF-10A-337Fuse for 61-337C-357Nylon Carrying CaseF-400mA-337Fuse for 61-337Scan with yoursmartphone to see avideo and learn more17 WWW.IDEALIND.COM

DIGITAL MULTIMETERS SELECTION GUIDENEWDIGITAL MULTIMETER SELECTIONGUIDENEW61-35761-347CAT IV 600VCAT III 1000VcULus, CE, RCM6.6 ft. 000CAT IV 600VCAT III 1000VcULus, CE, RCM6.6 ft. 000NEWNEW61-33761-327CAT III 600VCAT III 600VcULus, CE, RCM3.3 ft. cULus, CE, RCM3.3 ft. ESCAT Rating (Safety)ListingDrop ProtectionIngress ProtectionAC Voltage (Volts)DC Voltage (Volts)AC Current (Amps)DC Current (Amps)Ohms (Resistance)AC MillivoltsDC MillivoltsAC MilliampsDC MilliampsAC MicroampsDC Microamps ——High Voltage AlarmACV/DCV 30VACV/DCV 30VACV/DCV 30VACV/DCV 30VAudible Continuity -40 1832 F-40 1000 C-40 1832 F-40 1000 C-40 1832 F-40 1000 C— ——— — 6000 μF10Hz – 9.99 KHz6000 μF10Hz – 9.99 KHz4000 μF10Hz – 9.99 KHz—10Hz – 9.99 KHz —Low Battery Indication Battery Type (Included)LCD Display Count3 x 1.5V AAA60003 x 1.5V AAA60003 x 1.5V AAA40003 x 1.5V AAA2000 —Bar Graph ———Battery Test——— edIncludedIncludedIncludedLeads Only—True RMSVisual ContinuityBacklightTemperatureLow Impedance (LoZ)NCVAuto RangingRange HoldData HoldDiode TestCapacitance TestFrequency / Duty CycleMax / MinMagnetic Strap MountTest Probe HolderAuto-Power OffAPO DisableLead WarningFuse NotificationWarrantyAccessoriesLeads, Case & Temp. SensorThermocouple———Specifications are subject to change without notice.WWW.IDEALIND.COM 18

VOLTAGE TESTERSFEATURESScan with yoursmartphone to see avideo and learn moreNon-Contact VoltageAudible Indicationfor NCV, Continuity &High VoltageBacklit DisplayUniversal MagneticStrap ClipLoZEliminates GhostVoltage61-557Probe Holderfor StorageGFCI TestTL-757Test Leads19 WWW.IDEALIND.COMUMHS-757Universal MagneticHanging Strap (61-557)

VOLTAGE TESTERS SELECTION GUIDE61-557Voltage and Continuity Testerw/LCD, GFCI, Flashlight & NCVT6-600V AC/DC, CAT IV 600V600V61-5478 Level AC/DC Voltage Indicator withPolarity Indicator12-600V DC 24-600V ACCAT III 600V600VVol-Test Voltage Tester100-600V AC/DCCAT III 600V600V600VNEWVOLTAGE TESTER SELECTION GUIDEFEATURESCAT Rating (Safety)Listing PreferredDrop ProtectionIngress ProtectionAC Voltage (Volts)DC Voltage (Volts)High Voltage Alarm61-06561-076Vol-Con Voltage/Continuity Tester5-600V AC/DCCAT III 600VNEW61-55761-54761-07661-065CAT IV 600VcULus, CE6.6 ft. (2m)IP426 6006 600ACV 30 or DCV 30VCAT III 600VcULus, CE6.6 ft. (2m)IP4224 60012 600ACV/DCV 48VCAT III 600VcULusCAT III 600VcULus—5 6005 600——100 600100 600— ———— ————— 90-600V AC——— ——— —— ——— ——————3 x 1.5V AAA —4 x 1.5V LR44—600 ——— ——— —Removable FixedRemovableRemovableAudible ContinuityVisual ContinuityBacklightLow Impedance (LoZ)NCVAuto RangingMagnetic Strap MountTest Probe HolderFlashlightAuto-Power Off (APO)Low Battery IndicatorBattery TypeLCD Display CountBacklightDC Polarity IndicationLeadsGFCI TestDisplayWarrantyACCESSORIESTest LeadsMagnetic Hanging Strap ———LCD2-Year*Neon Lamps2-Year*Indicator Movement2-Year*Indicator Movement2-Year*TL-757UMHS-757 —UMHS-75761-070—61-070—Specifications are subject to change without notice.WWW.IDEALIND.COM 20

RECEPTACLE TESTERSFEATURESScan with yoursmartphone to see avideo and learn moreGreen LightsDigital VoltageReadoutProvides VoltageLevel at OutletIndicate Correct WiringRed LightsIndicate IncorrectWiringGFCI Testw/Indicator LightOn/Off ButtonConfirms Testeris WorkingLEDs Easily VisiblePlugged in or rotated to fitreceptacles.21 WWW.IDEALIND.COM

RECEPTACLE TESTER SELECTION GUIDENeon LampPolarity Indication61-517Fits Standard120V Outlets61-03561-051120V AC GFCIReceptacle/VoltageTesterCAT II 150V ACGFCI TestButton61-501E-Z Check Circuit TesterE-Z Check PlusGFCI CircuitTesterGFCI ReceptacleTester150VNEWRECEPTACLE TESTER SELECTIONGUIDE61-51761-05161-03561-501120V AC120V AC120V AC120V AC—Premium Neon Lamps— Made in the USA UL Listed LCD Display e RatingPolarity IndicationGFI TripWarranty——Specifications are subject to change without notice.WWW.IDEALIND.COM 22

NON-CONTACT VOLTAGE TESTERSFEATURESLanyard Slot(All models)Durable Clip(All models)Sealed Flush ButtonsAllows for protection from rain and dampness(IP67 Rating, Models 61-657 & 61-647) &single-hand operation.Overmolded Industrial Grip(61-657 & 61-647 models)LED FlashlightIn tip(61-657, 61-647, 61-637 models)Scan with yoursmartphone to see avideo and learn more23 WWW.IDEALIND.COM

NON-CONTACT VOLTAGE TESTERS FEATURES61-657Dual Range12 to 1000V ACNCVT w/FlashlightCAT IV 1000V61-647Single Range50 to 1000V ACNCVT w/FlashlightCAT IV 1000V1000V61-637Single Range24 to 600V ACNCVT w/FlashlightCAT IV 600V61-627Single Range50 to 600V ACNCVTCAT IV 600V600VDual Range on 61-657 only.Standard VoltageRangeIndicated by a Green LEDPower OnLow VoltageRangePresence ofVoltageIndicated by a Red LEDIndicated by a Blue LEDIndicated by a FlashingRed LED & Audible ToneWWW.IDEALIND.COM 24

NON-CONTACT VOLTAGE TESTERS SELECTION GUIDENEWNON-CONTACT VOLTAGE TESTERSELECTION GUIDENEWNEWNEW61-65761-64761-63761-627CAT IV 1000VCAT IV 1000VCAT IV 600VCAT IV 600VcULus, CE, RCMcULus, CE, RCMcULus, CE, RCMcULus, CE, RCM12 1000V AC50 1000V AC24 600V AC50 600V AC ——— —6.6 ft. (2m)6.6 ft. (2m)3.3 ft. (1m)3.3 ft. (1m)IP67IP67— — ——— Green On,Flashing RedBlue Low,Red HighGreen On,Flashing RedGreen On,Flashing RedGreen On,Flashing Red——— 2 x 1.5V AAA2 x 1.5V AAA2 x 1.5V AAA2 x 1.5V AAA2-Year*2-Year*2-Year*2-Year*FEATURESCAT Rating (Safety)ListingVoltage Sensing RangeDual RangeFlashlightDrop ProtectionIngress ProtectionDual Range SensitivityAudible IndicationAudible DefeatVisual IndicationVisual Range IndicatorLanyard CompatibleAuto-Power Off (APO)Low Battery IndicationBattery TypeWarrantySpecifications are subject to change without notice.25 WWW.IDEALIND.COM—

INFRARED THERMOMETERSFEATURESScan with yoursmartphone to see avideo and learn moreDual LaserTargeting61-847Dual Laser Targeting12:1 Infrared ThermometerLASER2WARNING61-827Single Laser Targeting10:1 Infrared ThermometerOvermolded IndustrialGripSingle LaserTargetingComplies with 21 CFR 1040.10 and 1040.11 except for conformance withIEC 60825-1 Ed. 3 as described in Laser Notice No. 56 dated May 8, 2019.INFRARED THERMOMETERSELECTION istingDrop ProtectionOptical Resolution (distance-to-spot)Measurement RangeLaser TargetingAuto ScanMax/Min/Avg/DiffHigh/Low AlarmData HoldLock-on (for continuous measurements)EmissivityBacklit DisplayDisplayAuto Power-OffSelectable Celsius / FahrenheitBattery TypeLow Battery IndicatorResponse TimeSpectral ResponseWarrantyNEWNEW61-84761-827cULusCLASS 2, IEC 60825-1:2014630nm-670nm 1mWcULs, CE6.6 ft. (2m)12 : 1-26 - 932 F (-32 to 500 C)DualcULusCLASS 2, IEC 60825-1:2014630nm-670nm 1mWcULs, CE3.3 ft. (1m)10 : 1-4 to 752 F (-20 to 400 C)Single —0.10 - 1.00 Adjustable—— —0.95 Fixed LCDLCD 2 x 1.5V AAA2 x 1.5V AAA 250 ms500 ms8 to 14µm2-Year*8 to 14µm2-Year*Specifications are subject to change without notice.WWW.IDEALIND.COM 26

SPECIALTY TESTERS61-5203-Phase RotationTester61-52161-7973-Phase Motor/RotationTester300V61-796Insulation Tester600V61-9203-Pole GroundResistance TesterGround ResistanceClamp Meter300V300V27 WWW.IDEALIND.COM61-795Insulation Testerw/PI, DAR61-686Digital LightMeter

SPECIALTY TESTERS FEATURESINSULATION TESTERSELECTIONGUIDEPHASE ROTATIONSELECTION GUIDE61-520Motor Rotation—Phase RotationColor Coded Leads Detachable Leads— 42-Year*2-Year*Warranty61-797250/500/1000V DC50/100/250/500/1000V DCVoltage AC/DC0.1 - 600.0V0.1 - 600.0VContinuity0.01 - 20.0 Ω—Resistance0.01Ω - 200.0 Ω0.01Ω - 40.00kΩInsulation ResistanceUp to 4000M ΩUp to 20G Ω2-Year*2-Year*FEATURESFEATURES120 to 600V AC61-79561-521Test VoltageACCESSORIES (Included)WarrantyTest LeadsACCESSORIES (Included)TL-521Test LeadsRemote ProbeTL-52161-9203 Point Fall of PotentialMethod4—Clamp on Technique—Auto Ranging—44FEATURES0 - 2000 Ω0 - 1200 CESSORIES (Included)Test LeadsTL-797RPRemote ProbeTest Lead SetLIGHT METERFEATURES61-796WarrantyTL-797RPTest Lead Setw/PremiumAlligator ClipsGROUND ROD TESTINGSELECTION GUIDEGround Leakage CurrentTL-795—TL-795Test Lead SetMeasuring RangeTL-795TL-79661-686FEATURESFour Measurement RangesData and Max Hold ModesAuto Zero AdjustLow Battery IndicationAuto Power OffRemote Sensor w/59” attachedCoiled CableWarrantyUp to 20,000 Foot Candles or200,000 Lux 2-Year*Specifications are subject to change without notice.Earth ResistanceLead SetWWW.IDEALIND.COM 28

ACCESSORIESNEWNEWTL-532A120V AC Circuit BreakerFinder Adapter KitTC-757ThermocoupleTL-797RPRemove Probe Test LeadNEWTL-757Universal Test Leads& Alligator ClipsTL-521Test Lead SetTL-795Test Leads w/ Alligator Clips(premium)UMHS-757Universal Magnetic Hanging Strap(For use with 61-405, 61-415, 61-737,61-747, 61-757, 61-327, 61-337, 61-347,61-357, 61-547 & 61-557)TL-796Earth Resistance Lead SetTLF-014Fused Test Lead KitCompatible with all testersReplacement fuses TLF-001(500mA/1000V, Pack of 2)61-070Standard Test Leads(for use with 61-076 & 61-065)29 WWW.IDEALIND.COMTL-956Test Lead Set

TEST LEAD SELECTION GUIDEFor this TESTER.use these TEST LEADS61-065Vol-Test Voltage Tester61-076Vol-Con Voltage/Continuity Tester61-070Standard Vol-Con Test Leads61-737 61-747 61-757Digital ClampMetersTL-757Test LeadSetUMHS-757Magnetic Strap61-405 61-415Digital Split JawMetersTL-757Test LeadSetUMHS-757Magnetic Strap61-557Voltage TesterTL-757Test LeadSetUMHS-757Magnetic Strap61-5213-Phase/MotorRotation TesterTL-521Test LeadSet61-327 61-33761-347 61-357DigitalMultimetersTL-757Test LeadSetUMHS-757Magnetic Strap61-744Clamp-Pro 600AClamp MeterTL-757Test LeadSetUMHS-757Magnetic Strap61-765660A Clamp Meter61-7751000A Clamp MeterTL-757Test LeadSet61-795Insulation TesterTL-795Premium TestLeads w/Alligator Clips61-7963-Pole GroundResistance TesterTL-796Earth ResistanceLead Set61-797Insulation TesterTL-795Test Leadsw/Alligator ClipsPremiumTR-955Transmitter forSureTrace Circuit TracersTL-956Test LeadSetTL-797RPRemote ProbeTest LeadWWW.IDEALIND.COM 30

CARRYING CASESC-90C-290Nylon CarryingCaseC-760Nylon CarryingCaseNylon CarryingCaseNEW61-179Nylon Carrying CaseC-90Nylon Carrying CaseC-290Nylon Carrying CaseC-357Nylon Carrying CaseC-760Nylon Carrying CaseC-757Nylon Carrying CaseC-770Nylon Carrying Case61-010Heavy Duty LeatherCase31 1-72770061-41561-35740061-34761-33761-327300Heavy DutyLeather Case61-744Nylon ection GuideC-757Nylon CarryingCase61-757C-357Nylon CarryingCase61-405C-770NEW61-73761-179Nylon CarryingCase

REPLACEMENT PARTS SELECTION GUIDETR-95595061-79761-79679061-79561-77561-765750 760 1-33730061-32761-076SELECTION GUIDE61-065060 070FUSESF-1051A (600V) 10.3 x 35mmF-3400.5A (500V) 6.35 x 32mmF-34110A (1000V) 10 x 38mmF-400mA-337400mA (600V) 6.5 x 32mmF-10A-33710A (600V) 10 x 38mmF-600mA-347357 600mA (1000V) 6.5 x 32 mmF-11A-34735711A (1000V) 10 x 38mmF-497 600mA (1000V) 10 x 35mmF-49811A (1000V) 10 x 38mmF-797315mA (1000V) 5 x 32mmBATTERIES AA 1.5V (AAA) 9V LR44TEST LEADSTLF-014Fused TestLead KitTL-796EarthResistanceLead SetTL-797RPRemoteProbe TestLead61-070Standard TestLeadsTL-757UniversalTest Leads &Alligator ClipsTL-521Test Lead SetTL-795Test Leads w/Alligator Clips(Premium)TL-956Test Lead Set WWW.IDEALIND.COM 32

SAFETY IN THE FIELDIEC (International Electrotechnical Commission) Category RatingsCategory I – The signal level for telecommunications, electronic andother low-energy equipment with transient limiting protection. Peakimpulse transient range is 600-4,000 volts with 30 ohm source.Category II – The local level for fixed and non-fixed powered devicesincluding appliances, lighting and portable equipment. Outletslocated more than 30 feet from CAT III sources and 60 feet from CATIV sources. Peak impulse transient range is from 600-6,000 volts witha 12 ohm source.Category III – The distribution level for fixed primary feeders orbranch

CLAMP METER SELECTION GUIDE 61-775 61-765 61-757 61-747 FEATURES CAT Rating (Safety) CAT IV 600V CAT III 1000V CAT IV 600V CAT III 1000V CAT IV 600V CAT III 1000V CAT III 600V Listing cULus, CE, RCM cULus, CE, RCM cULus, C

Related Documents:

IDEAL 4810-95 IDEAL 4850-95/EP IDEAL 5221-95EP IDEAL 6550-95EP B C A 4 x Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP Remove the stand from the wooden pallet. Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP 4 strong people are required to lift the machine from the pallet and place it on the stand. Secure with 4 .

IDEAL 4810-95 IDEAL 4850-95/EP IDEAL 5221-95EP IDEAL 6550-95EP B C A 4 x Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP Remove the stand from the wooden pallet. Only IDEAL 4810-95, IDEAL 4850-95/EP, IDEAL 6550-95EP 4 strong people are required to lift the machine from the pallet and place it on the stand. Secure with 4 .

IDEAL 4810-95/EP IDEAL 4850-95/EP IDEAL 5221-95EP IDEAL 6550-95EP C Only IDEAL 4810-95/EP Attach the enclosed hand-wheel for clamping. Parts and tools are in the tool set (C). Plug into socket. The machine must be connected directly to the socket. Installation

IDEAL LIFE GLUCO MANAGER, IDEAL LIFE POD, IDEAL LIFE Step Manager, IDEAL LIFE Breath Manager, IDEAL LIFE Direct Connect, IDEAL LIFE Health Tablet, REALIZING THE VISION OF A BETTER TOMORROW, Leveraging the Power of Communication, . Sprint provides full cellular network support for health information from anywhere. POD IDEAL LIFE and ADT announced

Prime Ideals and Maximal Ideals Definition (Prime Ideal, Maximal Ideal). A prime ideal A of a commuta-tive ring R is a proper ideal of R such that a,b 2 R and ab 2 A implies a 2 A or b 2 A. A maximal ideal A of R is a proper ideal of R if, whenever B is an ideal of R and A B R, then B A or B R.

Ideal Solution. In an Ideal Mixture, all components have the same size and they interact with each other uniformly. An Ideal Solution might better be called an Ideal Mixture, since, as in an Ideal Gas, no distinction is made between solute and solvent. All components of an ideal solution have chemical potentials of the form: μ of pure .

The GSA Standards Catalogue is a register of National Standards found in the GSA Library and on the GSA website which have been listed systematically. GSA publishes the main Standards Catalogue once a year and publishes supplementary copies to the main catalogue periodically. The Catalogue provid

Stanley Gibbons – Postage Stamp Catalogue Part One 1960 Bristish Commonwealth Stanley Gibbons – Simplified Catalogue – Stamps of the World – Volume 3. CommonWealth Countries 1990 edition StockList 2/2005 – Swiss Post The 1994 Belgian Stamp Catalogue The Australasian Stamp Catalogue – 23rd Edition full colour