REPLACEMENT INSTALLATIONS:GAS PLUMBINGITEMCATEGORY(ADMIN Gas Air Conditioning(Outdoors)2Gas Grill (CommercialIndoor)2Gas Barbecue(Commercial Outdoor)2Gas Grill (ResidentialIndoor)2Gas Barbecue(Residential Outdoor)2Must conform to FDNYrequirementsGas Boiler CAT-1 Vent(Atmospheric VentStandard Chimney)2Non-condensing requireslined chimneyGas Boiler CAT-2 Vent(Atmospheric Vent LinedChimney)2Condensing boiler requireslined metal chimney; Requiresneutralizing kit, drainage info,and vapor trapse-FileMust conform to FDNYrequirementsLAA / REPLACEMENT INSTALLATIONS: Gas Plumbing 1

ITEMCATEGORY(ADMIN Gas Boiler CAT-3 Vent(Non-condensing DirectPower Vented)2See RCNY 101-02, ifapplicableGas Boiler CAT-4 Vent(Condensing Direct PowerVented)2See RCNY 101-02, ifapplicable. Requiresneutralizing kit, drainage info,and vapor trapsGas Booster2Gas Connectors2Gas Dishwasher(Commercial)2Gas Dryer (Commercial)2Gas Emergency Shut OffValve2Gas Emergency Shut OffFire Suppression2Gas Fired Chiller2Gas Fireplace(Commercial)2e-File Must comply with MC-303LAA / REPLACEMENT INSTALLATIONS: Gas Plumbing2

ITEMCATEGORY(ADMIN Gas Fireplace(Residential)2Gas Fryer (Commercial)2Gas Furnace CAT-1 vent(Atmospheric VentStandard Chimney)2Non-condensing requireslined chimneyGas Furnace CAT-2 vent(Atmospheric Vent LinedChimney)2Condensing furnace requireslined metal chimney.Requires neutralizing kit,drainage info, and vaportrapsGas Furnace CAT-3 vent(Non- Condensing2See RCNY 101-02, ifapplicableGas Furnace CAT-4 vent(Condensing Direct PowerVented)2See RCNY 101-02, ifapplicable. Requiresneutralizing kit, drainageinformation, and vapor trapsGas GeneratorEmergency (CommercialIndoor)2No construction workpermittede-FileMust comply with MC-303 Direct Power Vented)LAA / REPLACEMENT INSTALLATIONS: Gas Plumbing3

ITEMCATEGORY(ADMIN Gas GeneratorEmergency (CommercialOutdoor)2No construction workpermittedGas GeneratorEmergency (ResidentialOutdoor Only)2No construction workpermittedGas Hot Water HeaterCAT-1 Vent (AtmosphericVent Standard Chimney)2Requires lined chimneyGas Hot Water HeaterCAT-2 Vent (AtmosphericVent Lined Chimney)2Condensing hot waterrequires: lined metalchimney, neutralizing kit,drainage information, andvapor trapsGas Hot Water HeaterCAT-3 Vent (Noncondensing Direct PowerVented)2See RCNY 101-02, ifapplicableGas Hot Water HeaterCAT-4 Vent (CondensingDirect Power Vented)2RCNY 101-02 (if applicable);requires neutralizing kit,drainage info and vapor trapsLAA / REPLACEMENT INSTALLATIONS: Gas Plumbinge-File 4

ITEMCATEGORY(ADMIN e-FileGas Infrared Heater(Direct Vent)2Gas Infrared Heater (NoVent)2 Gas Infrared Heater (Ventthrough Roof)2 Gas Light (Commercial)2 Gas Light (Residential)2 Gas Oil Burner Pilot2Gas Outdoor Cooktop(Commercial)2Gas Pizza Oven(Commercial)2 Gas Pool Heater2 Gas Pool Heater (OneFamily Indoor)2 Gas Pool Heater (OneFamily Outdoors)2 LAA / REPLACEMENT INSTALLATIONS: Gas Plumbing5

ITEMCATEGORY(ADMIN e-FileGas Pool Heater(Commercial Indoor)2 Gas Pool Heater(Commercial Outdoor)2 Gas Dryer (Residential)2 Gas Salamander Temporary Heat(Commercial)2Gas Infrared Heater(Direct Vent)2Gas Salamander Cooking (Commercial)2Gas Smoker (Outdoor)2Gas Steam Table(Commercial)2 Gas Stove (Residential)2 Gas Stove (Commercial)2Must conform to FDNYrequirementsLAA / REPLACEMENT INSTALLATIONS: Gas Plumbing 6

ITEMCATEGORY(ADMIN e-FileGas Unit Heater (Ventthrough Roof)2Gas Unit Heater (throughWall P-TAC)2See Building Bulletin 2015035 / must have CO sensorbuilt in; need originalapplication numberRe-routing of Existing GasPiping2Cannot install piping inpublic hallways Replace existing piping insame location forresidential cooking only2List all appliances servedby meter Gas regulator (Appliance)Residential2 **FOR APPLIANCES NOT LISTED REFER TO LAA UNIT**LAA / REPLACEMENT INSTALLATIONS: Gas Plumbing7

Gas Fired Chiller 2 Gas Fireplace (Commercial) 2 Must comply with MC-303 . Gas Oil Burner Pilot 2 Gas Outdoor Cooktop (Commercial) 2 Gas Pizza Oven (Commercial) 2 Gas Pool Heater 2 Gas Pool Heater (One Family Indoor) 2 Gas Pool Heater (One Family Outdoors) 2 LAA / REPLA

Related Documents:

Identify plumbing materials and ttings Identify plumbing pipe protection methods (i.e., re caulk, nail plates) Interpret and comply with general plumbing practices Interpret manufacturer's speci cations Testing of plumbing systems Identify plumbing terminology Identify plumbing symbols Joining Pipes and Fittings

Identify plumbing materials and fittings Identify plumbing pipe protection methods (i.e., fire caulk, nail plates) Interpret and comply with general plumbing practices Interpret manufacturer's specifications Testing of plumbing systems Identify plumbing terminology Identify plumbing symbols

The health implications of temperature and bacteria in plumbing installations. Electricity and electrical bonding in plumbing installations, particularly when making alterations to pipe work. Safety implications of plumbing installations in confined spaces and other hazardous areas (underground, under floor, attics etc)

Plumbing continued to supply materials to Pace Plumbing even thought Pace Plumbing failed to pay Peterson Plumbing for over six months (R. 1-2, 65-66). On August 13, 2008, after receiving notice of the mechanics1 liens, GCD sent Peterson Plumbing a written request to remove the wrongful liens because they were filed in a untimely manner(R. 1-2 .

Unit 1 of the textbook gives an introduction to plumbing and . its importance. Unit 2 focuses on the tools used in plumbing. It includes the various types of manual tools required for carrying out plumbing tasks. Unit 3 deals with the plumbing material and pipes used in plumbing. Unit 4 focuses on the measurement and symbols used in plumbing.

A&C Plumbing & Heating Co NYC LMP #0616 236-11 Braddock Ave Bellerose, NY 11426 718-347-9455 A-1 Underground Plumbing Con . New York, NY 10002 212-226-8320 AAA Total Plumbing, Inc. NYC LMP #2132 (Westchester Cnty. LMP #1253) 123 50th Street Brooklyn, NY 11232 718-788-3600 AB Plumbing Inc. NYC LMP #0963 6010 New Utrecht Avenue Brooklyn, NY .

Phone: dlb associates One Penn Plaza, Suite 2601, New York, NY 10119 CONSULTING ENGINEERS, P.C. (646) 381‐6721 BID SET NEW CLUB HOUSE ASH BROOK GOLF COURSE 1210 RARITAN RD, SCOTCH PLAINS, NJ 07076 PLUMBING INFORMATION SHEET PLUMBING GENERAL NOTES PLUMBING GENERAL NOTES Contract Requirements 1.

on criminal law reforms which I had begun in 2001 when still working as an attorney. Observing the reforms in action and speaking with judges and lawyers not only helped to inform my own work, but also helped me to see how legal reform operates in a