. Compliant to TIA/EIA 222-Fand TIA/EIA 222-G. Up to 190' Self-Support Tower. Standard 10' sections. Stocked at our distributionpartners for quick delivery. All members are hot-dipgalvanized throughout to provideyears of trouble free service. Applications: Microwave repeaters up to 130'Wireless broadbandPolice and fire dispatchHigh wind coastal zones. P.E. Stamp available

TIA/EIA Design CodesWind load capacity perTIA/EIA 222 standard (Rev. F)TIA/EIA (Rev. F) was released in June 1996, currently both TIA/EIA Rev. F and Rev. G standards are being used. Please verify withyour local permit agency which code is applicable for your location. Major differences from Rev F to Rev. G include: Rev. F has onestructure classification, while Rev. G has three — explained below. Also, Rev. F uses fastest wind mile wind speed as opposed tothree second gusts for Rev. G. For comparative purposes, 70mph fastest wind mile is equivalent to 85mph 3-second gust.Wind load capacity per latest revisionof TIA/EIA 222 standard (Rev. G)On January 1, 2006, a new revision (Rev G) of the national standard for tower design (TIA/EIA 222) was issued. The previousrevision which is also still in force, is called Rev F. Revision G made many significant changes vs. Rev F. One of the changes wasto introduce a ‘classification’ system for different tower structures which allows an Engineer to design a greater or lesser ‘safetyfactor’ into the tower depending upon it’s intended use and the risk of danger to human life. See Table 1 for the class descriptions.TIA/EIA uses maximum 3-second gust wind speed.Classification of StructuresClassification CriteriaReliability ClassStructures that due to height, use or location represent a low hazard to human life and damage to property in the event of failure and/or used for services that are optional and/or where a delay in returning the services would be acceptable. Class 1 structures need not bedesigned with any ice loading or earthquake consideration.1Structures that due to height, use or location represent a substantial hazard to human life and/or damage to property in the event of failureand/or used for services that may be provided by other means. These structures must consider ice loading and earthquake loading.2Structures that due to height, use or location represent a high hazard to human life and/or damage to property in the event of failure and/or used for services that may be provided by other means. These structures must consider ice loading and earthquake loading.3To assist Trylon customers who require Rev. G. design for their SuperTitan, we have provided the allowable antenna area chartbelow, which is based on Class 1 structures. For Class 2 or 3, contact Trylon TSF or your Distributor’s Tech Support group.26All prices in U.S. dollars.www.trylon.com

20' TowersModel Designation:Knocked-down PartNumber:Assembled Part 500.020Includes 5' embedmentsection for concrete foundation,splice hardware, and pipe anchorbrackets for antenna mounting pipe(pipe sold separately on page 68).12"15"18"21"24"15"18"21"24"27"Knocked-down towers reduceshipping cost in comparison withpre-assembled.18"21"24"27"30"EIA 222-FAllowableantennaarea inft2 at:*70/90/100 mph windno iceEIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight (lbs)Round: 90/50/35Flat: 64/35/25Round: 100/60/45Flat: 71/42/32Round: 120/70/55Flat: 85/50/39Round: 140/80/60Flat: 100/57/42Round: 203/117/91Flat: 145/83/65Round: 78/52/38Flat: 52/35/25Round: 92/64/46Flat: 61/43/31Round: 108/74/54Flat: 72/49/36Round: 122/86/62Flat: 81/57/41Round: 254/182/136Flat: 169/121/91Round: 66/46/32Flat: 44/31/21Round: 78/54/40Flat: 52/36/27Round: 92/64/46Flat: 61/43/31Round: 104/72/52Flat: 69/48/35Round: 218/156/116Flat: 145/104/77 1,162.35 1,216.62 1,254.69 1,293.04 1,355.13133x48x15 1,260.36133x48x15 1,321.11133x48x15 1,358.37133x48x15 1,403.73133x48x16 x43565578597624731*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitS100S200S300S400S500Cable SafetyClimb Kits no 0485.0504.99.0485.050 886.00 886.00 886.00 886.00 886.00Step-Bolt 0.0204.98.0100.020 170.00 170.00 170.00 170.00 170.00Anti-Climb .92.0001.0054.92.0001.006 458.00 504.00 550.00 596.00 640.00Tower Grounding 3.0004.91.0103.000 78.00 78.00 78.00 78.00 78.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.www.trylon.com27All prices in U.S. dollars.

30' TowersModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes 5' embedmentsection for concretefoundation, splice hardware,and pipe anchor brackets forantenna mounting pipe (pipesold separately on page 68).Knocked-down towers reduceshipping cost in comparisonwith pre-assembled.EIA 222-F70/90/100 mph windno iceAllowableantennaarea in ft2*EIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight 21"24"27"30"33"Round: 50/25/20Flat: 35/17/14Round: 60/30/21Flat: 42/21/15Round: 70/35/23Flat: 50/25/16Round: 140/75/56Flat: 100/53/40Round: 191/105/80Flat: 136/75/57Round: 46/30/18Flat: 31/20/12Round: 52/34/24Flat: 35/23/16Round: 60/40/28Flat: 40/27/19Round: 112/78/56Flat: 75/52/37Round: 186/130/94Flat: 124/87/63Round: 38/24/14Flat: 25/16/9Round: 44/30/18Flat: 29/20/12Round: 50/32/22Flat: 33/21/15Round: 94/6/46Flat: 63/44/31Round: 158/110/78Flat: 105/73/52 1,613.52 1,665.36 1,712.34 1,792.53 x16 1,758.51 1,816.83 1,868.67 1,960.20 x408568759081,0181,139*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitS100S200S300S400S500Cable SafetyClimb Kits no 0485.0504.99.0485.050 886.00 886.00 886.00 886.00 886.00Step-Bolt 0.0304.98.0100.030 255.00 255.00 255.00 255.00 255.00Anti-Climb .92.0001.0064.92.0001.007 504.00 550.00 596.00 640.00 687.00Tower Grounding 3.0004.91.0103.000 78.00 78.00 78.00 78.00 78.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.28All prices in U.S. dollars.www.trylon.com

40' TowersModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes 5' embedmentsection for concretefoundation, splice hardware,and pipe anchor brackets forantenna mounting pipe (pipesold separately on page 68).Knocked-down towers reduceshipping cost in comparisonwith pre-assembled.EIA 222-F70/90/100 mph windno iceAllowableantennaarea in ft2*EIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight 21"24"27"30"33"24"27"30"33"36"Round: 40/15/8Flat: 28/10/5Round: 45/17/10Flat: 32/12/7Round: 70/35/27Flat: 50/25/19Round: 135/77/57Flat: 96/55/40Round: 157/83/60Flat: 112/59/42Round: 28/14/8Flat: 19/9/5Round: 32/18/10Flat: 21/12/7Round: 56/36/24Flat: 37/24/16Round: 104/72/52Flat: 69/48/35Round: 126/84/56Flat: 84/56/37Round: 22/12/4Flat: 15/8/3Round: 26/14/6Flat: 17/9/4Round: 46/30/18Flat: 31/20/12Round: 88/60/44Flat: 59/40/29Round: 106/68/46Flat: 71/45/31 2,062.26 2,123.01 2,210.49 2,383.02 x24 2,254.23 2,327.13 2,425.14 2,614.68 x431,0781,1111,2411,3511,467*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitS100S200S300S400S500Cable SafetyClimb Kits no 0485.0504.99.0485.050 886.00 886.00 886.00 886.00 886.00Step-Bolt 0.0404.98.0100.040 340.00 340.00 340.00 340.00 340.00Anti-Climb .92.0001.0074.92.0001.008 550.00 596.00 640.00 687.00 732.00Tower Grounding 3.0004.91.0103.000 78.00 78.00 78.00 78.00 78.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.www.trylon.com29All prices in U.S. dollars.

50' TowersModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets for antennamounting pipe (pipe soldseparatelyon page 68).Models S100 to H800 usea 5' embedment section asthe anchor for concrete.Knocked-down towers reduceshipping cost in comparisonwith '#103.5'#11HD3.75'#12HD4'#13EIA 222-F70/90/100 mph windno iceAllowableantennaarea in ft2*EIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight (lbs)Round: 22/3/-Flat: 15/2/--Round: 40/15/10Flat: 28/10/7Round: 60/30/24Flat: 42/21/17Round: 90/44/26Flat: 64/31/18Round: 100/47/30Flat: 71/33/21Round: 110/50/30Flat: 78/35/21Round: 113/57/41Flat: 80/40/29Round: 14/6/-Flat: 9/4/--Round: 30/16/8Flat: 20/11/5Round: 52/34/22Flat: 35/23/15Round: 82/50/32Flat: 55/33/21Round: 88/54/34Flat: 59/36/23Round: 128/84/54Flat: 85/56/36Round: 154/102/68Flat: 103/68/45Round: 12/--/-Flat: 8/--/--Round: 24/12/4Flat: 16/8/3Round: 44/28/16Flat: 29/19/11Round: 66/42/24Flat: 44/28/16Round: 72/44/28Flat: 48/29/19Round: 108/68/44Flat: 72/45/29Round: 128/84/54Flat: 85/56/36 2,519.10 2,621.97 2,800.98 2,961.36 3,122.55 3,492.72 x25133x48x25122x48x26 2,764.53 2,883.60 3,079.62 3,256.20 3,427.11 3,815.10 22,479*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitS100S200S300S400S500S600H800Cable SafetyClimb Kits no 0485.0504.99.0485.0504.99.0485.0504.99.0485.050 886.00 886.00 886.00 886.00 886.00 886.00 886.00Step-Bolt 0.0504.98.0100.0504.98.0100.0504.98.0100.050 425.00 425.00 425.00 425.00 425.00 425.00 425.00Anti-Climb 2 596.00 640.00 687.00 732.00 779.00 818.00 929.00Tower Grounding 3.0004.91.0103.0004.91.0103.0004.91.0103.000 78.00 78.00 78.00 78.00 78.00 78.00 78.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.30All prices in U.S. dollars.www.trylon.com

50' Towers continuedModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets for antennamounting pipe (pipe soldseparatelyon page 68).Model H810 uses a 5'embedment section as theanchor for concrete; modelsS1000 to S1200 use base feetand tie-rods for concretefoundation.Knocked-down towers reduceshipping cost in comparisonwith pre-assembled.EIA HD6'#15#167'8'#15#13Round: TBAFlat: Round: 119/67/53Flat: 85/47/37Round: 180/100/70Flat: 128/71/50Round: 187/103/80Flat: 133/73/57EIA Rev.G Class 1 Round: 154/102/68Flat: 103/68/45Round: 274/186/126Flat: 183/124/84Round: 276/188/122Flat: 184/125/81Round: 278/190/134Flat: 185/127/89EIA Rev.G Class 2Round: 128/84/54Flat: 85/56/36Round: 230/152/102Flat: 153/101/68Round: 236/152/92Flat: 157/101/63Round: 234/158/110Flat: 156/105/73 5,550.93 8,718.84 9,753.21 10,180.08122x48x26133x48x48133x48x48133x48x48 6,097.68N/AN/AN/A70/90/100 mph windno iceAllowableantennaarea in ft2*H81090/105/120 mph wind3/4" ice90/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight tions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitH810S1000S1100S1200Cable SafetyClimb Kits no 0485.050 886.00 886.00 886.00 886.00Step-Bolt 0.050 425.00 934.00 1,135.00 1,336.00Anti-Climb .92.0001.213 929.00 1,544.00 1,544.00 1,544.00Tower Grounding 3.003 78.00 1,099.00 1,099.00 1,099.00leg mountedbasic, single legTower Grounding KitFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.www.trylon.com31All prices in U.S. dollars.

60' TowersModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets for antennamounting pipe (pipe soldseparatelyon page 68).Models S100 to H700 usea 5' embedment section asthe anchor for concrete.Knocked-down towers reduceshipping cost in comparisonwith 13EIA 222-F70/90/100 mph windno iceAllowableantennaarea in ft2*EIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight (lbs)Round: 21/3/-Flat: 15/2/--Round: 40/15/8Flat: 28/10/5Round: 60/28/17Flat: 42/20/12Round: 70/30/19Flat: 50/21/13Round: 80/33/21Flat: 57/23/15Round: 100/40/23Flat: 71/28/16Round: 103/47/30Flat: 73/33/21Round: 14/4/-Flat: 9/3/--Round: 28/14/6Flat: 19/9/4Round: 50/30/16Flat: 33/20/11Round: 56/32/16Flat: 37/21/11Round: 82/50/32Flat: 55/33/21Round: 122/80/50Flat: 81/53/33Round: 126/76/46Flat: 84/51/31Round: 10/--/-Flat: 7/--/--Round: 22/10/2Flat: 15/7/1Round: 42/22/10Flat: 28/15/7Round: 46/24/12Flat: 31/16/8Round: 66/40/24Flat: 44/27/16Round: 102/62/38Flat: 68/41/25Round: 102/58/36Flat: 68/39/24 3,018.06 3,212.46 3,379.32 3,559.95 3,928.50 4,610.52 x25133x48x26133x48x30 3,321.00 3,538.08 3,720.33 3,917.16 4,297.05 5,053.59 02,784*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitS100S200S300S400S500S600H700Cable SafetyClimb Kits no 0485.1004.99.0485.1004.99.0485.1004.99.0485.100 994.00 994.00 994.00 994.00 994.00 994.00 994.00Step-Bolt 0.0604.98.0100.0604.98.0100.0604.98.0100.060 510.00 510.00 510.00 510.00 510.00 510.00 510.00Anti-Climb 2 640.00 687.00 732.00 779.00 818.00 876.00 929.00Tower Grounding 3.0004.91.0103.0004.91.0103.0004.91.0103.000 78.00 78.00 78.00 78.00 78.00 78.00 78.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.32All prices in U.S. dollars.www.trylon.com

60' Towers continuedModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets for antennamounting pipe (pipe soldseparatelyon page 68).Model H710 uses a 5'embedment section as theanchor for concrete; modelsS900 to S1100 use base feetand tie-rods for concretefoundation.Knocked-down towers reduceshipping cost in comparisonwith 12/160Flat: 273/141/106Round: 162/80/54Flat: 108/53/36Round: 164/86/62Flat: 109/57/41Round: 198/112/88Flat: 132/75/58Round: 182/100/78Flat: 121/66/52Round:350/174/130Flat: 233/116/86Round: 126/76/46Flat: 84/51/31Round: 152/106/76Flat: 101/71/51Round: 152/106/76Flat: 101/71/51Round: 262/176/120Flat: 175/117/80Round: 262/176/120Flat: 175/117/80Round: 264/184/130Flat: 176/123/8790/105/120 mph wind3/4" iceRound: 102/58/36Flat: 68/39/24Round: 130/90/64Flat: 87/60/43Round: 130/90/64Flat: 87/60/43Round: 220/144/90Flat: 147/96/60Round: 220/144/90Flat: 147/96/60Round: 224/154/108Flat: 149/103/72EIA 222-F70/90/100 mph windno iceAllowableantennaarea in ft2*N/A3'3'2.5'EIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 2KnockeddownTowersAssembledTowersList Price 6,104.16 9,260.73 9,746.73 10,309.68 10,795.68 x48133x48x48133x48x48List Price /AN/A2,8314,3434,3904,7904,8375,142Shipping Weight (lbs)*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitH710S900S910S1000S1010S1100Cable SafetyClimb Kits no 0485.1004.99.0485.1004.99.0485.100 994.00 994.00 994.00 994.00 994.00 994.00Step-Bolt 0.0604.98.1000.0604.98.1100.060 510.00 1,019.00 1,019.00 1,220.00 1,220.00 1,421.00Anti-Climb .92.0001.2134.92.0001.2134.92.0001.213 929.00 1,544.00 1,544.00 1,544.00 1,544.00 1,544.00Tower Grounding 3.0034.91.0103.0034.91.0103.003 78.00 1,099.00 1,099.00 1,099.00 1,099.00 1,099.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.www.trylon.com33All prices in U.S. dollars.

70' TowersModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets for antennamounting pipe (pipe soldseparatelyon page 68).Models S100 to H600 usea 5' embedment section asthe anchor for concrete.Knocked-down towers reduceshipping cost in comparisonwith ound: 20/1/-Flat: 14/--/--Round: 36/13/4Flat: 24/9/2Round: 52/16/5Flat: 34/11/3Round: 56/17/6Flat: 37/12/4Round: 71/24/10Flat: 47/16/7Round: 74/30/18Flat: 49/21/12Round: 110/48/26Flat: 73/32/17Round: 14/2/-Flat: 9/1/--Round: 26/14/4Flat: 17/9/3Round: 38/16/4Flat: 25/11/3Round: 52/30/14Flat: 35/20/9Round: 78/48/30Flat: 52/32/20Round: 88/48/28Flat: 59/32/19Round: 88/48/28Flat: 59/32/19Round: 8/--/-Flat: 5/--/--Round: 20/10/-Flat: 13/7/--Round: 28/12/-Flat: 19/8/--Round: 44/22/10Flat: 29/15/7Round: 62/38/20Flat: 41/25/13Round: 66/36/16Flat: 44/24/11Round: 66/36/16Flat: '#12#12HD4'#13EIA 222-F70/90/100 mph windno iceAllowableantennaarea in ft2*EIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight (lbs)#13 3,608.55 3,790.80 3,977.91 4,365.90 5,045.49 5,785.02 x26133x48x27133x48x30 3,975.48 4,178.79 4,382.10 4,787.10 5,535.54 6,351.21 23,063*Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitS100S200S300S400S500S600H600Cable SafetyClimb Kits no 0485.1004.99.0485.1004.99.0485.1004.99.0485.100 994.00 994.00 994.00 994.00 994.00 994.00 994.00Step-Bolt 0.0704.98.0100.0704.98.0100.0704.98.0100.070 595.00 595.00 595.00 595.00 595.00 595.00 595.00Anti-Climb 2 687.00 732.00 779.00 818.00 876.00 929.00 929.00Tower Grounding 3.0004.91.0103.0004.91.0103.0004.91.0103.000 78.00 78.00 78.00 78.00 78.00 78.00 78.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.34All prices in U.S. dollars.www.trylon.com

70' Towers continuedModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets for antennamounting pipe (pipe soldseparatelyon page 68).Model H610 uses a 5'embedment section as theanchor for concrete; modelsS800 to S1100 use base feetand tie-rods for concretefoundation.Knocked-down towers reduceshipping cost in comparisonwith .25'TOP#62.5'N/A#83'#10#93.25'#10HD3.5'#11HDEIA Rev.G Class 190/105/120 mph wind3/4" iceEIA Rev.G Class 290/105/120 mph wind3/4" iceKnockedList PricedownL"xW"xH"TowersAsList PricesembledL"xW"xH"TowersShipping Weight ennaarea in ft2*#135'#13#146'#135'5'#135'#135'#12HD70/90/100 mph windno .25'TOP#83'3'2.75'N/A3'TOP#8#73.75'EIA 222-FN/A2.75'2.75'#18Round: 120/54/32Flat: 81/36/21Round: 144/64/42Flat: 96/42/28Round: 150/70/46Flat: 100/46/30Round: 160/79/60Flat: 106/52/40Round: 176/96/76Flat: 117/64/50Round: 306/160/120Flat: 204/106/80Round: 340/172/126Flat: 226/114/84Round: 88/48/28Flat: 59/32/19Round: 140/92/56Flat: 93/61/37Round: 140/92/56Flat: 93/61/37Round: 146/102/74Flat: 97/68/49Round: 234/150/96Flat: 156/100/64Round: 234/150/96Flat: 156/100/64Round: 254/176/116Flat: 169/117/77Round: 66/36/16Flat: 44/24/11Round: 116/74/46Flat: 77/49/31Round: 116/74/46Flat: 77/49/31Round: 124/86/60Flat: 83/57/40Round: 194/120/72Flat: 129/80/48Round: 194/120/72Flat: 129/80/48Round: 216/144/88Flat: 144/96/59 6,593.40 9,826.11 10,312.11 10,850.76 11,928.06 12,414.06 Assumptions: Projected areas (PA) shown are bare; a 1.5 multiplier used for iced area; loads centrally located and balanced at tower top; considers step-pegs, safety cable, and one 1/2" tx line per 10 sq.ft.; “--” indicates tower failure.*Round antennas include omnis, dipoles, dishes with radomes, etc. Antennas where wind hits a round surface. Flat Antennas include flat panels, dishes without radomes and cameras, where wind hits a flat surface.Common AccessoriesCable Safety Climb Kit(slider not included)Accessory:Step-Bolt KitAnti-Climb Shield KitTower Grounding KitH610S800S810S900S1000S1010S1100Cable SafetyClimb Kits no 0485.1004.99.0485.1004.99.0485.1004.99.0485.100 994.00 994.00 994.00 994.00 994.00 994.00 994.00Step-Bolt 0.0704.98.1000.0704.98.1000.0704.98.1100.070 595.00 1,104.00 1,104.00 1,305.00 1,506.00 1,506.00 1,707.00Anti-Climb 3 929.00 1,544.00 1,544.00 1,544.00 1,544.00 1,544.00 1,544.00Tower Grounding 3.0034.91.0103.0034.91.0103.0034.91.0103.003 78.00 1,099.00 1,099.00 1,099.00 1,099.00 1,099.00 1,099.00leg mountedbasic, single legFor more SuperTitan Accessories and Replacement Parts, see pages 61 to 76.www.trylon.com35All prices in U.S. dollars.

80' TowersModel Designation:Knocked-down PartNumber:Assembled Part Number:Includes anchor materialfor concrete foundation,splice hardware, and pipeanchor brackets

TIA/EIA Design Codes Wind load capacity per TIA/EIA 222 standard (Rev. F) TIA/EIA (Rev. F) was released in June 1996, currently both TIA/EIA Rev. F and Rev. G standards are being used. Please verify with your local permit agency which code is applicable for your location. Major diff erences from

Related Documents:

1) ANSI/TIA/EIA - 455: Fiber Optic Test Standards 2) ANSI/TIA/EIA - 526: Optical Fiber Systems Test Procedures 3) ANSI/TIA/EIA - 568-B: Commercial Building Telecommunications Cabling Standard 4) ANSI/TIA/EIA - 569: Commercial Building Standard for Telecommunication Pathways and Spaces 5) ANSI/TIA/EIA - 606: The Administration Standard for the

240 hours at 98% RH, per EIA/TIA-455-5, Method B Ozone Exposure 150 ppm for 2 hours at 158 F ( 70 C), per TIA/EIA-455-189 Sand & Dust 12 hours, per TIA/EIA-455-35 Fungus Resistance 28 days at 86 F ( 30 C), 95% RH, per TIA/EIA-455-56 Flamability 0.75 inch flame for 10 seconds mated, 1.50 inch flame for 60 seconds unmated, per EIA/ECA-364-81

ANSI/TIA/EIA-568-B.1 and its addenda ANSI/TIA/EIA-568-B.2 and its addenda TIA-569-B and its addenda ANSI/TIA/EIA-606-A ANSI/TIA/EIA-J-STD-607 ANSI/NECA/BICSI-568 ISO/IEC 11801 2nd edition CENELEC EN50173 27 10 02.02.B If this document and any of the documents listed above are in co

Data Center Standards TIA/EIA 568 Copper & Fiber Cabling ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers TIA/EIA 569 Pathways & Spaces TIA/EIA 606 . TIA-942 Data Center Logical Layout. TIA-942 Data Center Major Elements. Data Center Tier Levels Tier I Basic Tier II Redundant Components Tier III Concurrently Maintainable

TIA/EIA-606-A Labeling Compliance TIA/EIA-606-A Standard For compliance with the TIA/EIA-606-A standard, Panduit has the solution. This brochure will walk you through the labeling requirements of the standard and introduce you to identification solutions specifically designed to comply with TIA/EIA-606-A.The standard establishes guidelines for .

EIA/TIA 570: For residential cabling. EIA/TIA 606: cabling system administration (documentation), ISO/IEC 14763-1 EIA/TIA 607: Grounding and bonding International Standards The international equivalent of EIA/TIA 568 is ISO/IEC 11801. The standards are written similarly to what has been done by TR 42. Here are their relevant standards:

Temperature endurance TIA/EIA 455-4 1000 h @ 125 C (cable dependent) Vibration TIA/EIA 455-11 16.4 Grms Shocks TIA/EIA 455-14 50 G, 11 ms Durability TIA/EIA 364-09 500 cycles Maintenance aging SAE AS 13441 method 2002.1 10 cycles Cable retention 1.88 mm diameter SAE AS 13441

o Additif alimentaire. 41 Intrants alimentaires: o Matière première : matière unique ou principale soumise à la transformation Unique : blé en minoterie, betterave ou canne en sucrerie Principale en volume : lait pour le yaourt, eau pour les boissons gazeuses Principale en valeur : sucre pour les boissons gazeuses 1. Chapitre introductif 1.4- Intrants et produits des IAA. 42 o Ingrédient .