Controller - 4 X 1-10 V Outputs - BUS/KNX

2y ago
10 Views
2 Downloads
1.19 MB
6 Pages
Last View : 11d ago
Last Download : 2m ago
Upload by : Noelle Grant
Transcription

87045 LIMOGES Cedex FranceTelephone: ( 33) 05 55 06 87 87 - Fax: ( 33) 05 55 06 88 88Controller - 4 x 1-10 V outputs BUS/KNXCatalogue number(s): 0 488 62CONTENTS1.2.3.4.5.6.7.8.9.Page Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Technical features . . . . . . . . . . . . . . . . 1Dimensions . . . . . . . . . . . . . . . . . . . . . 2Connection . . . . . . . . . . . . . . . . . . . . . 2Installation . . . . . . . . . . . . . . . . . . . . . . 3 Parameter setting . . . . . . . . . . . . . . . . 4Communication objects . . . . . . . . . . . . 4Care . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Standards . . . . . . . . . . . . . . . . . . . . . . 61. USE2. TECHNICAL CHARACTERISTICS (continued)This device is a power unit used for managing lighting loads.Voltage: 100-240 V Frequency: 50/60 HzNo load power consumption: 4 WIt must be connected to one or more detectors and/or remote auxiliarycontrols in order to operate.Power side:Power supply: 2 x 2.5 mm2 (screw terminals)N L: via normally open relay contact0 - 10 V 1.5 mm2The load(s) can be controlled manually or automatically by thedetectors and/or the controls associated with the device.2. TECHNICAL CHARACTERISTICSControlbuttonsLEARN LED:indicates the learningphase or RESETKNXBUSIndicators(on if outputactivated)1234Red LED:indicates that the BUS capacityhas been exceeded"PROG& RESET" LED"PROG& RESET" button K NXConnection between the controller and products in the KNX offer:KNX cable fitted with red, black KNX connector (350 m max. ofcable between the power supply and the furthest product. Beyondthis distance, repeaters must be used.)The product incorporates positive safety- If there is a peripheral fault on the BUSautomatically after 10 minutes.Fluorescent tubesTungsten halogen bulbsCompact fluorescent bulbs1 - 10 V ballast, the lights come back onProduct installation: in a suspended ceiling or on a suitable cable tray123444230 V 4 x 1000 VA110 V 4 x 500 VATechnical data sheet: S000064191EN-2CONTENTSControl side BUSConnection between the compatible peripherals in the offer andthe controller: RJ 45 cord or BUS cable to fit RJ 45 connector(max. 150 m between the controller and the furthestperipherals)4 x 4.3 A4 x 1000 VA4 x 500 VAUpdated on: 18/05/20124 x 4.3 A4 x 1000 W4 x 500 W4 x 4.3 ACreated on: 06/07/20121/6

Controller - 4 x 1-10 V outputs BUS/KNXCatalogue number(s): 0 488 622. TECHNICAL CHARACTERISTICS (continued)4. CONNECTIONPeripherals compatible with the KNX offer:- BUS detectors: infrared, ultrasound or dual technology- Pushbutton lighting controls, switch and scenario managementmultifunction controls. 200 mAAll the wiring must be carried out with the mains power off.BUS/KNX connectionL4Usage temperature: -5 C to 45 CStorage temperature: -20 C to 70 CWeight: 580 gImpact resistance: IK04Penetration by solid and liquid matter: IP20L3L2L13. DIMENSIONS1475050275240150 m max.Schematic diagramBUS/KNX power supplyCat. No. 0 035 12IP communicationmoduleCat. No. 0 035 43ETSsoftwareControllersORScenario 1:Scenario 2:BUS/KNX connectionBUS/KNX - USBinterfaceCat. No. 0 035 47ETSsoftware350 m max.Technical data sheet: S000064191EN-2CONTENTSUpdated on: 18/05/2012Created on: 06/07/20122/6

Controller - 4 x 1-10 V outputs BUS/KNXCatalogue number(s): 0 488 624. CONNECTION (continued)5. INSTALLATION1Using double connector Cat. No. 0 488 68Mounting2On cable tray211/42Cat. No. 0 488 68341/4or2Cat. No. 0 488 72AWConnects directly to the controllerand/or detector.34Technical data sheet: S000064191EN-2CONTENTSUpdated on: 18/05/2012Created on: 06/07/20123/6

Controller - 4 x 1-10 V outputs BUS/KNXCatalogue number(s): 0 488 626. PARAMETER SETTING7. COMMUNICATION OBJECTS (continued)NB: All the wiring must be carried out with the mains power off.Switching the controller on generates an automatic configuration.Configuring the controller means that the wiring can be checked.Compatible peripheral(s) and the controller recognise one another ontheir BUS. All detectors control all loads.The KNX system must be configured using a PC with ETS softwareinstalled. This means each peripheral can be connected to its load.Technical documentation regarding KNX product settings is integratedin the ETS database available from January 2012.Pro Relations department: 0810 48 48 48 48 (local call rate in France)Mon-Fri 8 am-6 pmNote: All technical information is available atLike for objects 0, 1, 2, 3, 4, 5, 7 assigned to controller output 1,objects 8, 9, 10, 11, 12, 13, 15 are assigned to output 2, objects 16,17, 18, 19, 20, 21, 23 are assigned to output 3 etc.Obj. Function32ScenarioObject nameNRC-IN RECALLSCENARIOTypeFlag17.001CWSceneControl(1 byte)This object is used to call scenes which have been configured on thecontroller. Up to 32 scenarios can be configured.Warning: Each controller output can be controlled in amaximum of 10 scenarios.www.legrandoc.com7. COMMUNICATION OBJECTS7.1 BUS/KNX suspended ceiling controllers for dimming(0/10 V ballast)Obj. Function0On/OffObject nameTypeFlagNRC Ch1– IN ON/ 1.001 Switch CWOFF(1 bit)This object is used for On/Off of control luminaires connected tocontroller output 1.1 /- DimmingNRC Ch1 – IN DIM 3.007 Control CWDimming (4bits)This object is used to vary the light intensity of all luminairesconnected to controller output 1.2ValueNRC Ch1 – IN5.001 Scaling CWLEVEL(1 byte)This object is used to modify the level of light of all luminairesconnected to controller output 1.3On/OffNRC Ch1 – OUT1.001 Switch CRTON/OFF STATUS(1 bit)This object gives access to the status of luminaires connected tocontroller output 1. A 1-bit status (On/Off) is sent.4Obj. FunctionObject nameTypeFlag5Enable/NRC Ch1 – IN1.003 Enable CWDisableENABLE/DISABLE (1 bit)This object is used to block or unblock the output in its presentstatus. Commands will not be recognised.7OverrideNRC Ch1 - IN2.001 Switch CWOVERRIDE ON/OFF Control (2 bits)– 2 bitsThis object is used to control the state of controller output 1 with theconcept of priority:Bits 01: Output ONBits 00: Output OFFBits 11: Output forced to ONBits 10: Output forced to OFF67Scenario29SCHEDULE6FaultNRC OUTSCENARIO17.001CRWTUSceneControl(1 byte)This object is used to transmit the scenario numbers configured onthe peripherals connected to the controller.NRC IN1.003 Enable CWSCHEDULE(1 bit)AUTOMATIONThis object is used to block all automated control by detectorsconnected to the controller.If the object 1: The detectors are inactiveIf the object 0: The detectors control the level of lightNRC OUT BUS1.002CRTDEFAUTBoolean (1 bit)This object is used to signal a fault on the control bus, amalfunctioning peripheral or disconnected peripheral.If the object 1: Communication faultIf the object 0: No faultValueNRC Ch1 – OUT5.001 Scaling CRTLEVEL STATUS(1 byte)This object gives access to the status of luminaires connected tocontroller output 1. A status with the value of 1 byte (0 100%) issent.Technical data sheet: S000064191EN-2CONTENTSUpdated on: 18/05/2012Created on: 06/07/20124/6

Controller - 4 x 1-10 V outputs BUS/KNXCatalogue number(s): 0 488 627. COMMUNICATION OBJECTS (continued)7. COMMUNICATION OBJECTS (continued)7.2 Peripherals7.2.2 ON/OFF lighting controls, 1 and 2 way- Lighting control modeObj. FunctionObject nameTypeFlag*On/Off . Ch1 CMD OUT 1.001 Switch CTON/OFF(1 bit)This object is used to send the ON/OFF telegram generated by ashort press on the control unit.* /- Dimming . – Ch1 CMD3.007 Control CTOUT DIMDimming(4 bits)This object is used to send the dimming telegram generated by along press 0.5 s on the control unit.*Value . – Ch1 CMD IN 5.001 Scaling CRWLEVEL STATUS (1 byte)This object is used to manage feedback of information about thecontrol unit.Byte 0 blue LEDByte 0 pink LED*On/Off .– Ch1 CMD IN 1.001 Switch CRWON/OFF STATUS (1 bit)This object is used to manage feedback of information about thecontrol unit.Byte 0 blue LEDByte 1 pink LED* The object numbers for the connected peripherals are assigneddynamically when the ETS project is created.The object name is preceded by the 8-digit product identifier.7.2.1 Switch type multifunction control, 1 and 2 way- Lighting control modeObj. Function*On/OffObject nameTypeFlag . Ch1 CMD OUT 1.001 Switch CTON/OFF(1 bit)This object is used to send the ON/OFF telegram generated by ashort press on the control unit.* /- dimming . – Ch1 CMD3.007 Control CTOUT DIMDimming(4 bits)This object is used to send the dimming telegram generated by along press 0.5 s on the control unit.*Value . – Ch1 CMD IN 5.001 Scaling CRWLEVEL STATUS (1 byte)This object is used to manage feedback of information about thecontrol unit.Byte 0 blue LEDByte 0 pink LED*On/Off . – Ch1 CMD IN 1.001 Switch CRWON/OFF STATUS (1 bit)This object is used to manage feedback of information about thecontrol unit.Bit 0 blue LEDBit 1 pink LED- Shutter control modeThese communication objects are available for each control unit.7.2.3 Light level measurement cellObj. Function*LUXObject nameTypeFlag . – Ch1 OUT LUX 9.004 LuxCT(2 bytes)This object is used to transmit the level of light measured by the lightlevel cell (0 65535 lux).Obj. Function*Up/DownObject nameTypeFlag . Ch1 CMD SHT 1.008 Up/CTOUT UP/DOWN Down (1 bit)This object is used to send the telegram generated by a long press 0.5 s on the control unit.Bit 0 The shutter goes upBit 1 The shutter goes down*Step/Stop . Ch1 CMD SHT 1.009 Switch CTOUT STOP(1 bit)This object is used to send, with a short press, the Stop telegram ifthe shutter is moving and the Step down telegram if the shutter isstationary.*Status . Ch1 CMD SHT 5.001 Scaling CRWIN POS STATUS (1 byte)This object is used to manage feedback of information about thecontrol unit.Byte 0 blue LEDByte 0 pink LEDThese communication objects are available for each control unit.Technical data sheet: S000064191EN-2CONTENTSUpdated on: 18/05/2012Created on: 06/07/20125/6

Controller - 4 x 1-10 V outputs BUS/KNXCatalogue number(s): 0 488 627. COMMUNICATION OBJECTS (continued)8. CARE7.2.4 Wall-mounting detectors (flush or surface), detectors formounting in suspended ceilings, surface-mounting detectorsDo not use: acetone, tar-removing cleaning agents ortrichloroethylene.Resistant to the following products: - Hexane (EN 60669-1)- Methylated spirit- Soapy water- Diluted ammonia- Bleach diluted to 10%- Window-cleaning productsObj. Function*PresenceObject nameTypeFlag . – Ch1 SENSOR 1.018WTOUT OCC/OccupancyUNOCC(1 bit)This object is used to send a telegram concerning presence and endof presence.If object 1: Presence detectedIf object 0: End of presenceWarning: End of presence is sent at at the end of the detectortime delay.*Presence . – Ch1 SENSOR 1.018CWTIN OCC/UNOCC Occupancy(1 bit)This object is used to receive a detection frame from anotherdetector.If object 1: PresenceIf object 0: End of presence*On/Off . – Ch1 SENSOR 1.001 Switch CTOUT ON/OFF(1 bit)This object is used to send the ON/OFF telegram to the actuator.Warning: Whether this object is sent depends on the detectorparameter setting mode.*On/Off . – Ch1 SENSOR 1.001 Switch CRWIN ON/OFF(1 bit)STATUSThis object is used to feed back the load status for On/Off closedloop regulation.WARNING: A lways test before using other special cleaningproducts.9. STANDARDSDirective: CEInstallation standards: NFC 15-100Product standards: IEC 60669-2-1Environmental standards:- EU Directive 2002/96/EC:WEEE (Waste Electrical and Electronic Equipment)- EU Directive 2002/95/EC:RoHS (Restriction of Hazardous Substances)- Decrees and/or regulations: E RP (public buildingsERT (workplace buildings)IGH (high-rise buildings)Warning: When the Level-Status object is connected, this objectcannot be used.*Value . – Ch1 SENSOR 5.001 Scaling CTOUT LEVEL(1 byte)This object is used to check the level of a load as a percentage. Thisobject is used for dimming regulation (open or closed loop).*Value . – Ch1 SENSOR 5.001 Scaling CRWIN LEVEL(1 byte)STATUSThis object is used to feed back the load status for dimming closedloop regulation.Warning: When the ON/OFF-Status object is connected, thisobject cannot be used.*LUX . – Ch1 SENSOR 9.004 Lux (2 CRWIN LUXbytes)This object is used for the link with an external light level cell in thecase of open loop regulation (internal measurement is disabled).Warning: When the detector is operating in open loop mode, acalibration phase with luxmeter is compulsory.*SYNCHRO . – Ch1 SENSOR 1.001 Switch CWNISATIONIN SYNCHRO(1 bit)This object is used to integrate a manual control in the control loop.It must be linked to the control object “CH CMD OUT ON/OFF”.Warning: If the object is not used, following a command thedetector will always cut off regulation and switch to overridemode.Technical data sheet: S000064191EN-2CONTENTSUpdated on: 18/05/2012Created on: 06/07/20126/6

Controller - 4 x 1-10 V outputs - Catalogue number(s): 0 488 62 BUS/KNX Technical data sheet: S000064191EN-2 Updated on: 18/05/2012 Created on: 06/07/2012 CONTENTS 3/6 5. INSTALLATION Mounting On cable tray 1 3 4 2 1/4 1/4 A W 1 3 2 4 2 2 Using double connector Cat. No. 0 488 68 4. CONN

Related Documents:

Fig.4.1 Step response using P controller Fig.4.2 Fig.4.3 Fig.4.4 Fig.4.5 Step response using PID controller Fig.4.6 Comparison of bode plot for smith predictor and PI . Step response of IMC PDF control structure Step response of PDF controller Step response using PI controller Step response using PID controller Step response using PI controller

Trimble Survey Controller Procedure Sheet Working with Total Stations and Trimble Survey Controller Create a job on the Controller: -Turn on your Controller and go into Survey Controller Software - -Create a new job by going into Files/New Job -Note to set the Scale Factor to 1.0 when working with a Total Station. Hit Accept to create your new job.

P-49-0203 (MPN600203) P-49-0204 (MPN600204) P-49-(MPN600) Metaris # Alternate # Single Controller Air Kit Single Controller ONLY Dual Controller Air Kit W/ Kickout Dual Controller Air Kit W/O Kickout Single Controller Air Kit W/ Protection Valve P-53-0177 MPN600177 Name cover Plate for Controller 1 1 1

Aruba 7008 Mobility Controller Aruba 7010 Mobility Controller Aruba 7024 Mobility Controller Aruba 7030 Mobility Controller Aruba 7210 Mobility Controller ArubaOS_72xx_8.1.0.0-1.0.0.0 ArubaOS_72xx_ 8.4.0.0-1.0.6.0 ArubaOS_72xx_8.4.0.0-1.0.5.1 Aruba 7220 Mobility Controller Aruba 7240 Mobility Con

STRYKER CVAHU N4 CONTROLLER 9 31-00088—01 INTRODUCTION Stryker CVAHU Controller is a pre-programmed configurable controller. It can be configured using ‘CVAHU Configuration Wizard’ This configuration wizard is developed under Niagara 4 Workbench. Stryker CVAHU Controller The Honeywell Stryker CVAHU controller is a configurable controller.

Controller Firmware Comment CMMS-ST-. From Version 1.3.0.1.14 Standard motor controller for stepper motors CMMS-AS-. From Version 1.3.0.1.16 Standard motor controller for servo motors CMMD-AS-. From Version 1.4.0.3.2 Standard double motor controller for servo motors Table 1.1 Controller and firmware versions For older versions:

If you just purchased USB Controller board and the software, you may want to refer to the document - Connecting and Wiring AGNI USB Controller for the recommended wiring of the controller board in your system. Make sure and understand which controller you have to follow separate instructions for the 32-bit controller or older 16-bit controller.

Please notice that this controller does not support the following functions of the DUALSHOCK 4 wireless controller: light bar, integrated speaker, integrated speaker, motion sensors or wired support I Switch OFF the controller Press and hold the "PS" button until the controller turns off. To wake up the controller, press the "PS" button.