S4 Lapneaks InguagesOwner’s Manual

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterDear Prodigy Meter Owner:Thank you for choosing the Prodigy AutoCode meteras your blood glucose monitoring system. Pleaseread this manual carefully as it contains importantinformation about your new Prodigy system. Awarranty registration card is included with your system.Please return the completed card to us or completewarranty online at www.prodigymeter.com.Prodigy meters: Require No Coding, allowing you to save timeand avoid human error due to improper coding. Allow you to perform Alternate Site Testing (AST). Have memory and data management capabilities.Prodigy’s free software gives you and yourhealthcare professionals powerful graphic tools tomanage your diabetes.Prodigy meters are designed to help you and yourhealthcare professionals monitor your blood glucoselevels. This owner’s manual will help you learn how touse your Prodigy meter effectively. Customer Care isavailable 24 hours, 7 days a week by calling toll free1.800.243.2636. All questions concerning test resultsshould be directed to your healthcare professional.Prodigy meters have the latest technology forblood glucose monitoring and are made with qualitycomponents. All Prodigy meters are easy to use, giveyou fast, accurate test results with a minimal sample ofblood, have large, easy-to-read display screens, and arelightweight and portable for your convenience.Owner’s Manual2Owner’s Manual3

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterTable of ContentsUsing the Meter Memory.47-49Specifications.50Viewing Results on a Personal Computer.51Caring for your Prodigy Meter.52-56Cleaning your System. 52Lancing Device . 52Disinfecting your System. 52-53Storing your System. 53Battery . 54Low Battery. 54-55Battery Replacement. 55-56System Troubleshooting.57-63Special Messages. 57-58Error Messages. 58-59Troubleshooting Guide. 60-63Information About your Prodigy Meter.64-72Comparing Meter and Laboratory Results. 64-66Performance Characteristics. 66Expected Test Results. 67Unexpected Test Results. 68-69Accuracy of Meter Measurements. 70-72Symbols Information.73Warranty Information.74Limited Lifetime Warranty. 74Letter to Meter Owner.2-3Table of Contents.4-5Important Safety Instructions.6-8Important Health-Related Information. 9-10Alternate Site Testing (AST).11-13About Prodigy Test Strips.14-16Key Functions of the Test Strip. 14Important Test Strip Information. 15-16Introduction to Prodigy Meters.17-18Intended Use. 17Test Principle. 17-18Contents of the Prodigy AutoCode Meter.18Setting up the Prodigy AutoCode Meter.19-28Key Functions of the Meter. 19Meter Display . 20-21Speaking Function. 22Setup Steps. 23-28Control Solution Testing.29-36Performing a Control Solution Test . 32-36Performing a Blood Glucose Test.37-46Preparing the Lancing Device. 37-39Getting a Blood Sample. 39-41Tips for Applying Blood without Sight. 41-43Applying Blood to the Test Strip. 44-46Owner’s Manual4Owner’s Manual5

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterImportant Safety InstructionsRead this before using your Prodigy meter. Thefollowing basic safety precautions should alwaysbe taken. Your Prodigy meter, test strips, lancets andlancing device are for single patient use only.Do not share them with anyone, includingother family members. Do not use onmultiple patients. Close supervision is necessary when thedevice is used by, on, or near children,handicapped persons or invalids. Use the device only for the intended usedescribed in this manual. Do not use test strips and control solutionswith your Prodigy meter that are notsupplied by Prodigy . Do not use the device if it is not workingproperly, or if it has suffered any damage. Before using any product to test your bloodglucose, read all instructions thoroughlyand practice the test. Do all quality controlchecks as directed and consult with adiabetes healthcare professional.Owner’s Manual6 Keep the test strip vial away from children;the vial cap and the test strips can be apotential choking hazard. Never chew or swallow a test strip. If thisoccurs, please seek medical assistanceimmediately. All parts of this kit are consideredbiohazardous and can potentially transmitinfectious diseases, even after you haveperformed cleaning and disinfection. These devices are intended to be used forpatient self-monitoring and should not beused to collect blood from more than oneperson as this poses a risk of transmittingblood-borne pathogens such as Hepatitis Bor HIV.For further information, please refer to:“FDA Public Health Notification: Use of FingerstickDevices on More than One Person Poses Riskfor Transmitting Blood-borne Pathogens: InitialCommunication” (2010) Notices/ucm224025.htmOwner’s Manual7

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterImportant Health-Related Information“CDC Clinical Reminder: Use of FingerstickDevices on More than One Person Poses Riskfor Transmitting Blood-borne Pathogens” vicesBGM.htmlSevere dehydration and excessive water lossmay cause false low results. If you believe youare suffering from severe dehydration, consult ahealthcare professional immediately.Under normal blood concentrations andconditions, the following should not significantlyaffect results: Elevated blood triglycerides Reducing substances such as uric acid andascorbic acid Acetaminophen Dopa Methyldopa L-dopa TolbutamideDO NOT CHANGE YOUR TREATMENT BASED ON ASINGLE RESULT THAT DOES NOT MATCH HOW YOUFEEL OR IF YOU BELIEVE THAT YOUR TEST RESULTCOULD BE INCORRECT.If you are experiencing symptoms that are notconsistent with your blood glucose test resultsand you have followed all instructions describedin this owner’s manual, contact your healthcareprofessional.Owner’s Manual8Owner’s Manual9

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterTest results below 60 mg/dL (3.3 mmol/L) indicatelow blood glucose (hypoglycemia). Test resultsgreater than 240 mg/dL (13.3 mmol/L) indicatehigh blood glucose (hyperglycemia). If yourresults are below 60 mg/dL or above 240 mg/dL,repeat the test, and if the results are still below 60mg/dL (3.3 mmol/L) or above 240 mg/dL (13.3mmol/L), consult your healthcare professionalimmediately.Inaccurate results may occur in severelyhypotensive individuals or patients in shock.Inaccurate results may occur for individualsexperiencing a hyperglycemic-hyperosmolarstate. Please refer to the test strip package insertfor additional important information.Alternate Site Testing (AST)There are important limitations to Alternate SiteTesting (AST). Please consult your healthcareprofessional before performing AST.What is AST?Alternate Site Testing (AST)means you can use partsof the body other thanyour fingertips to checkyour blood glucose levels.Prodigy meters allow you totest on your palm, forearm,upper arm, calf or thigh.See Figure 1.What is the Advantage?Fingertips feel pain moreFigure 1readily because they are full ofnerve endings (receptors). At other body sites,nerve endings are not so numerous and you willnot feel as much pain as you will experience atthe fingertip.Owner’s Manual10Owner’s Manual11

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterWhen to use AST?Food, medication, illness, stress and exercise canaffect blood glucose levels. Capillary blood atthe fingertip reflects these changes faster thancapillary blood at other sites. Therefore, if youare testing your blood glucose level during orimmediately after a meal, physical exercise orstressful event, take the blood sample from yourfingertip only.*To increase accuracy when using AST, rubthe puncture site before extracting blood. Analternate site device is required to perform AST. Ifyou do not have an alternate site device but wouldlike to use one, please contact Customer Care at1.800.243.2636.Use AST only:v Two hours or more after your last meal.v Two hours or more after taking insulin.v Two hours or more after exercise.v During a relaxed and calm state.Do not use AST if:v You have reason to believe you havehypoglycemia or hyperglycemia.v Your routine glucose results are oftenfluctuating.v You are pregnant.Owner’s Manual12Owner’s Manual13

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterAbout Prodigy Test StripsKey Functions of the Test StripAll Prodigy meters measure the amount of sugarin the blood, commonly referred to as bloodglucose. Blood is applied to the opening of theabsorbent channel on the end of the test stripand is automatically drawn into the test strip.The test strip consists of the following parts:Please refer to the “Performing a Blood Glucose Test”section for complete instructions.Important Test Strip Information Store test strip packages in a cool, dry placebetween 39 F–104 F (4 C–40 C). Keepaway from direct sunlight and heat. Do notrefrigerate. Do not store in your car. Store your test strips in their original vialonly. Do not transfer them to a new vial orany other container.Absorbent ChannelApply a drop of blood and it will bedrawn in automatically. With clean, dry hands you may touch the teststrip anywhere on its surface when removingit from the vial or inserting it into the meter.Confirmation WindowShows whether enough blood has been drawninto the test strip’s absorbent channel. Do not clean the testing site with alcohol.Instead, wash the test site thoroughly withsoap and water only.Test Strip HandleHold this part to insert the test strip into the teststrip port on the meter. Immediately use a test strip after removing itfrom the vial, replace the vial cap and close ittightly to prevent exposure to moisture.Contact BarsInsert this end of the test strip into the meter.Push it in firmly until it will not go any further.Figure 2Owner’s Manual14Owner’s Manual15

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose Meter Only apply a blood sample or a controlsolution sample to the test strip’s absorbentchannel. Applying other substances to thetest strip’s absorbent channel will causeinaccurate results. Record the discard date on the vial labelwhen you first open it. Discard remainingtest strips 90 days after the first openingdate. Do not use test strips beyond the expirationdate printed on the package. After removing the test strip from the vial,insert it directly into the meter. Do not laythe test strip on any other surface.Intended UseProdigy blood glucose monitoring systemsare intended for use outside the body (in vitrodiagnostic use only) and should only be used forblood glucose (blood sugar) testing with freshcapillary whole blood samples.These systems are intended for use in the homeand in clinical settings and should not be usedfor the diagnosis of diabetes or for the testingof newborns. Consult your healthcare provider ifunusual readings occur.Test PrincipleBlood glucose is measured by an electricalcurrent that is produced when a blood samplemixes with the reagent (special chemicals) of thetest strip. The electrical current changes with theamount of glucose in the blood sample. Prodigy meters measure the strength of the electricalcurrent, calculate your blood glucose leveland then display your result in either mg/dL ormmol/L.Warning: Keep the test strip vial away fromchildren; the vial cap and the test strips canbe a potential choking hazard. Never chew orswallow a test strip. If this occurs, please seekmedical assistance immediately.Owner’s ManualIntroduction to Prodigy Meters16Owner’s Manual17

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterProdigy meters, test strips and control solutionshave been designed, tested and proven to worktogether as a system to produce accurate bloodglucose test results.Important: Use only Prodigy control solutionsand test strips with your Prodigy meter. Usingother test strips and control solutions with thismeter can produce inaccurate results.Contents of the Prodigy AutoCode Meter The Prodigy AutoCode meter is available as ameter only or as a meter kit. Please check the“REF” number marked on the outside of thebox to see if you have purchased a “Meter” or a“Meter Kit.” Please review the contents of yourpurchase to confirm that all the components areincluded as listed on the side of your meter box.Owner’s Manual18Setting up the Prodigy AutoCode Meter Key Functions of the MeterTest Strip SlotInsert the test strip here.The meter will turn onautomatically.LCD DisplayGuides you through thetest using symbols andsimple messages.Main ButtonTurns the meter on or performs otherfunctions described in this manual.Data PortPort for USB cable connection toyour computer.Figure 3Set ButtonLocated on the back of the meter,inside the battery compartment;used to setup the meter.Owner’s Manual19

PRODIGY AutoCode Blood Glucose MeterMeter DisplayTimePRODIGY AutoCode Blood Glucose MeterMeter DisplayDateDay AverageIndicates that thedisplayed test resultis an average.Test Result AreaDisplays test results.Test Strip SymbolAppears whenthe meter is intesting mode.Blood DropSymbolFlashes whensample shouldbe applied.TemperatureSymbolAppears whentemperatureis outside ofoperatingrange.Figure 4Low BatterySymbolAppears whenthe batterypower is low.Figure 5Unit of MeasureIndicates what unitof measure the testresult is displayed in.Voice SymbolShows if audiofunction is on.Control SolutionTest SymbolShows that you are in control solution mode.Owner’s ManualMemorySymbolAppears whenyou review thememory.20Owner’s Manual21

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterSpeaking FunctionThe Prodigy AutoCode meter talks you througheach step of your testing procedure.When does themeter speak?What does themeter say?When the meter isturned on.Your Prodigy meter is on.Please wait. Please insertthe test strip.Temperature isWhen room temperatureout of range.is outside operating range;which is 50 F–104 F (10 C–40 C).When the meter is readyto test ( appears on display).Please apply blood intothe test strip.When the test is completed(the result appears on thedisplay).Blood glucose (number)milligrams per deciliter/millimoles per liter.When you turn off the meter.Goodbye.When a used test strip isinserted.Test strip has been used.When blood is applied tothe test strip.Testing.Owner’s Manual22Setup StepsThe Prodigy AutoCode meter has several differentsettings that may need to be adjusted before usingthe meter. You should check the time and dateeach time the batteries are replaced.STEP 1: Insert the BatteriesOpen the battery cover located on the backsideof the meter. Insert two (2) AAA Alkaline batteriesand align them properly. The meter will turn onand enter Setting Mode.STEP 2: Enter Setting ModeIf your meter is off, press the “SET” button locatedin the battery compartment. The meter is now inthe setting mode.Voice Speaks: “Your Prodigy meter is on.Please wait. Setting mode. English.”STEP 3: Select LanguageThe language option appears first with “L-1” onthe LCD. By default, “L-1” indicates the defaultlanguage (English); “L-2” indicates the secondlanguage (Spanish); “L-3” indicates the thirdlanguage (French); and “L-4” indicates the fourthOwner’s Manual23

PRODIGY AutoCode Blood Glucose Meterlanguage (Arabic). See Figure 6.Press the “M” button to selecta language. With the correctlanguage selected, press the“SET” button and a numberwill appear.STEP 4: Setting Volume Level Numbers 1 to 3 indicatespeaking volume from low tohigh, where “ ”is displayed on the LCDduring testing. See Figure 7. Number 0 indicates that thespeaking function is turnedoff. See Figure 8.Press the “M” button to selectthe speaking volume. Then pressthe “SET” button and the yearsegment will appear and startflashing. See Figure 9.Owner’s ManualPRODIGY AutoCode Blood Glucose MeterSTEP 5: Set the YearPress and release the “M”button to advance the year.With the correct year on thedisplay, press the “SET” buttonand the date will appear onthe display with the monthsegment flashing. Figure 10.Figure 6STEP 6: Set the MonthPress and release the “M”button to advance the month.With the correct month on thedisplay, press the “SET” buttonand the date segment will startflashing. See Figure 11.Figure 7STEP 7: Set the DatePress and release the “M”button to advance the date.With the correct date on thedisplay, press the “SET” buttonand the time will appear on thedisplay with the hour segmentflashing. See Figure 12.Figure 824Owner’s ManualFigure 9Figure 10Figure 1125

PRODIGY AutoCode Blood Glucose MeterSTEP 8: Set the HourPress and release the “M”button to advance the hour.With the correct hour on thedisplay, press the “SET” buttonand the minutes segment willstart flashing. See Figure 13.STEP 9: Set the MinutesPress and release the “M”button to advance the minutes.With the correct minutes on thedisplay, press the “SET” buttonand the current unit ofmeasurement will start flashing.PRODIGY AutoCode Blood Glucose MeterSTEP 10: Select Unit ofMeasurement See Figure 14.Press and hold the “M” buttonfor (4) seconds until the unit ofmeasurement you are choosingappears on the display. Pressthe “SET” button and thememory segment will startflashing. See Figure 15.To skip this step, press the “SET”button.Figure 12Your meter can display testresults in milligrams perdeciliter (mg/dL) or millimolesFigure 15per liter (mmoL/L). The mg/dL unit is standardin the United States. The mmol/L unit is standard in Canada.Figure 13Important: Day averages are calculated fromresults obtained during the 7, 14 and 28 dayspreceding the current date and time settings.Owner’s ManualFigure 14STEP 11: Delete MemoryWhen the “dEL” symbol and the flashing “ ”symbol appear on the display, you can choose toclear the memory. If you do not want to clear thememory, press the “SET” button again to skipthis step.26Owner’s Manual27

PRODIGY AutoCode Blood Glucose MeterIf you want to clear ALLmemory, press the “M” buttonfor (4) four seconds.See Figure 16.The “- - -” will appear to indicateall memory has been deletedand the meter will turn off.PRODIGY AutoCode Blood Glucose MeterControl Solution TestingIf your Prodigy control solution did not come witha Prodigy Control Solution Insert, the followinginformation shall take the place of the insert.Product Numbers:Figure 16990310 (Low) 53310 (Low) 53350 (High)Setup is now complete. “OFF”is displayed and the meter willturn off. See Figure 17.Intended Use:Prodigy control solution is a red liquid thatcontains glucose that will react with test strips andproduce a test result. You can use either high orlow Prodigy control solution with your Prodigy system.Figure 17Summary:Prodigy control solutions contain certainamounts of glucose that can be tested with allProdigy brand glucose meters. Test resultsshould fall within the control ranges printed onthe back of your Prodigy test strip vial.Owner’s Manual28Owner’s Manual29

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterCaution: The control solution ranges arelocated on the back of the Prodigy test stripvial. They are not recommended target rangesfor your blood glucose. When you begin using a new vial of test strips When test strips have been exposed to extremeenvironmental conditions. If you drop the meter. If you change the battery in the meter.Important Information: Use only Prodigy control solutions with yourProdigy meter. Check the expiration date on the bottle.Do not use if expired. Use within a period of 90 days from the datethat you first open it. Record thediscard date on the control solution bottlewhen you first open it to serve as a reminderto discard after 90 days. For in vitro diagnostic use.Storage and Handling: Store the control solution tightly closed attemperatures below 86 F (30 C). Do not refrigerate. Do not store in your car.Composition:Glucose(% w/v)Low Solution 0.05High Solution 0.19Why Perform a Control Solution Test: To ensure that your meter and test strips areworking properly together. To allow you to practice testing without usingyour own blood.Nonreactive Ingredients(% w/v)99.9599.81When to use: Once a week (to ensure that you continue tohave accurate results).Owner’s Manual30Owner’s Manual31

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterImportant: Be sure that you are in controlPerforming a Control Solution Testsolution mode so that the test result will not bestored in the meter memory.Start with the meter off.STEP 1: Wash your HandsWash your hands with mild soap and waterbefore performing any test. Be sure to drythem thoroughly.STEP 2: Insert Test StripInsert a test strip with the contact bar endentering into the test strip slot first. Push thetest strip as far as it will go without bending it.The meter turns on automatically.STEP 3: Mark as a Control Solution TestAfter the “ ” symbol appears on the display,press the “M” button and a “ ” symbol appearson the display. With the “ ” symbol on thedisplay, the meter will not store your test resultin the memory. If you decide not to performa control solution test, press the “M” buttonagain and the “ ” symbol will disappear.Owner’s Manual32STEP 4: Apply Control Solution1. Check the expiration and discard dates onyour control solution and test strip vials.2. Shake the control solution bottle well, thenremove cap.3. Squeeze the bottle and discard the first dropthen wipe the dispenser tip with clean tissuepaper or cotton.4. Squeeze the bottle again toget a second drop onto aclean, non-absorbent surfaceor on your clean fingertip.See Figure 18.5. Bring the tip of the test stripto touch the drop of solutionFigure 18until the meter beeps.Owner’s Manual33

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterCaution: To avoid contaminating the controlsolution with the content of the test strip,DO NOT DIRECTLY APPLY CONTROL SOLUTIONONTO THE TEST STRIP. See Figures 19 and 20.Questionable Results:If the test result falls outside the range printedon the test strip vial, check the “Trouble-ShootingGuide” located in the “System Troubleshooting”section of this manual and repeat the test.Results that fall outside of the expected controlranges may indicate: An error in performing the test Control solution bottle not shaken wellFigure 19 Expired or contaminated control solutionFigure 20 Control solution that is too warm or too coldSTEP 5 : Check if the Test Result is in Range.After the meter counts down from 6 to 1, the controlsolution test result appears on the display.Compare the test result withthe range printed on the teststrip vial.Each vial of Prodigy No Coding Test Strips mayhave a different controlsolution range. The resultshould fall within the printedrange on the test strip vial.See Figure 21.Figure 21Owner’s Manual Test strip deterioration Meter malfunction Test strips expired34Owner’s Manual35

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterPerforming a Blood Glucose TestCaution: Do not use test strips or controlsolution that have exceeded the discard date,are expired or have been damaged.Your results may be inaccurate.Preparing the Lancing DeviceSTEP 1: Remove the cap of thelancing device by twisting it off.See Figure 22.Contact Customer CareIf your test strips have been damaged or if youcontinue to get out-of-range results, it meansthat the system or the control solution may notbe working properly. DO NOT use the system totest your blood glucose level. If you are unable toresolve the problem, contact Customer Care at1.800.243.2636.STEP 2: Insert a sterile lancet into thelancet holder of the lancingdevice and push down firmly untilthe lancet is fully seated. Do nottwist the lancet. See Figure 23.Figure 22STEP 3: Remove the protective capfrom the lancet by twisting it andthen save it for later use.See Figure 24.Figure 23STEP 4: Replace the cap onto thelancing device. Screw the capuntil it is snug but not too tight.STEP 5: Set the lancing level.The adjustable tip offers five (5)levels of skin penetration. Toselect the desired depth, twist theOwner’s Manual36Owner’s ManualFigure 24Figure 2537

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose Meteradjustable tip in either direction until the numberlines up with the arrow. Choose from the followingdepths: 1-2 (least penetration) for soft or thin skin, 3(average penetration) for average skin, 4-5 (deepestpenetration) for thick or calloused skin. See Figure 25.Warning: To reduce the risk of infection: Never share a lancet or lancing device. Always use a new, sterile lancet. Lancets are for single use only, do not reuse. Avoid getting hand lotion, oils, dirt ordebris in or on the lancets and the lancingdevice. These devices are intended to be used forpatient self-monitoring and should not beused to collect blood from more than oneperson as this poses a risk of transmittingblood-borne pathogens such as HepatitisB or HIV.STEP 6: Cock the lancing device.Slide the cocking control backuntil it clicks. If it does not click,the lancing device may havebeen cocked when the lancet wasinserted. See Figure 26.Owner’s Manual*The lancing device is prepared and ready tolance your finger for a blood sample.Getting a Blood SampleSTEP 1: Wash Your Hands and Puncture SiteUse warm, soapy water. Rinse and dry your handsthoroughly.STEP 2: Select and Lance a Puncture Site FingertipHold the lancing devicefirmly against the side ofyour finger. Press the releasebutton. You will hear a click,indicating that the puncture isFigure 27complete. See Figure 27. Sites other Than Your FingertipPlease refer to the “About Alternate SiteTesting (AST)” Section. Please consult yourhealthcare professional before obtainingblood from sites other than your fingertip.Figure 2638Owner’s Manual39

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose MeterSTEP 3: Obtain a Blood SampleDo not smear the blood sample. See Figure 28. Toobtain the most accurate results, wipe off the firstdrop of blood and gently milk the finger to obtainanother drop of blood. See Figure 29.Figure 28Figure 29STEP 4: Remove the LancetRemove the cap of the lancingdevice by twisting it off. Place theprotective cap back on theexposed tip of the lancet bypushing the lancet into it.Eject the lancet by sliding theeject button forward.See Figure 30.*Always use caution whenremoving the lancet. Discard thelancet according to your localsafety regulations.Owner’s ManualWarning: The first drop of blood usuallycontains tissue fluid and serum, which mayaffect the test result. It should be discarded.Tips for Applying Blood Without SightUsing the following four (4) tips may helpyou place a blood sample into the test stripsuccessfully if you have little or no vision. Theexample describes a way to bring the sampleand the test strip together. Other techniques maywork just as well. Keep experimenting until youfind a technique that consistently works for you.Tip One —Smaller has its AdvantagesBecause the Prodigy AutoCode meter is soeasy to move around, you can experiment withmany different approaches to determine whichworks best for you. Get comfortable holding themeter in one hand while testing. The meter canbe moved towards your finger as easily as yourfinger can be moved to the test strip.Tip Two — Aim for the TipThe tip of the test strip contains an opening to theabsorbent channel in the center where the bloodshould be applied. The absorbent channel drawsFigure 3040Owner’s Manual41

PRODIGY AutoCode Blood Glucose MeterPRODIGY AutoCode Blood Glucose Meterthe blood into the test strip, much like a straw,when the tip touches the blood sample. Bloodshould be applied only on the very tip. Bloodapplied to the bottom or sides of the test stripmay cause inaccurate readings. It is important thatthe test strip does not bend at all when applyingthe sample.Tip Three — Using a Sideways ApproachW

PRODIGY AutoCode Blood Glucose Meter PRODIGY AutoCode Blood Glucose Meter Owner’s Manual 16 Owner’s Manual Only apply a blood sample or a control solution sample to the test strip’s a

Related Documents:

PRODIGY Owner’s Manual 23 Prodigy Diabetes Care, LLC 1.800.243.2636 Contents of the Prodigy AutoCode Meter The Prodigy AutoCode meter is available as a meter only or as a meter kit. Please check the “REF” number marked on the outside of the box to see if you have purchased a “Meter

PRODIGY Owner's Manual Prodigy Diabetes Care, LLC www.prodigymeter.com 50 51 Prodigy Diabetes Care, LLC 1.800.243.2636 PRODIGY Owner's Manual Contents of the Prodigy Voice Meter The Prodigy Voice meter is available as a meter kit only. Please review the contents of your purchase to confirm that all the components are included as listed .

PRODIGY AutoCode Blood Glucose Meter PRODIGY AutoCode Blood Glucose Meter Owner's Manual Owner's Manual Test results below 60 mg/dL (3.3 mmol/L) indicate low blood glucose (hypoglycemia). Test results greater than 240 mg/dL (13.3 mmol/L) indicate high blood glucose (hyperglycemia). If your results are below 60 mg/dL or above 240 mg/dL,

PRODIGY AutoCode Blood Glucose Meter PRODIGY AutoCode Blood Glucose Meter Owner's Manual Owner's Manual Test results below 60 mg/dL (3.3 mmol/L) indicate low blood glucose (hypoglycemia). Test results greater than 240 mg/dL (13.3 mmol/L) indicate high blood glucose (hyperglycemia). If your results are below 60 mg/dL or above 240 mg/dL,

Contents of the Prodigy AutoCode Meter The Prodigy AutoCode meter is available as a meter only or as a meter kit. Please check the "REF" number marked on the outside of the box to see if you have purchased a "Meter" or a "Meter Kit." Please review the contents of your purchase to confirm that all the components are

The Prodigy AutoCode meter has the latest technol-ogy for blood glucose monitoring and is made with quality components. It is easy to use, provides fast test results with a minimal sample of blood, has a large, easy-to-read display screen, and is lightweight and portable for your convenience. The Prodigy AutoCode meter is designed to help you

BOX , LTCT METER, HT METER, GRID METER, PRODIGY METER & ABT METER. The bidder must qualify the technical requirements as specified in clause 2.0 stated below.The sealed envelopes shall be duly superscribed as v RATE CONTRACT FOR SUPPLY OF 3 PHASE METER WITH BOX & WITHOUT BOX , LTCT

Petitioner-Appellee Albert Woodfox once again before this Courtis in connection with his federal habeas petition.The district c ourt had originally granted Woodfox federal habeas relief on the basis of ineffective assistance of counsel, but weheld that the district court erred in light of the deferential review affordedto state courts under the Antiterrorism and Effective Death Penalty Act of .