GE LED Tubes DataSheet LEDL046

3y ago
19 Views
2 Downloads
3.24 MB
18 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Farrah Jaffe
Transcription

LED TubesComplete. Innovative. Trusted

Why switch to LED tubes?LED Tubes are the fast and easy way to upgrade to LED. With Current's UL Type A,Type B and UL Type C options, you can choose the best solution for your needs.2.3X longer life(70K vs. 30K hrs.)Uses 43% less energy(18W and 2600 lumens vsLFL 32W and 2800 lumens)Better quality of light(Instant-On)Which LED tube is right for you?Integrated LED Tube(UL Type A)Ballast Bypass LED Tube(UL Type B)Remote Driver LED Tube(UL Type C)Easy Plug & Play PerformanceSimplest system directwiring to mainsBest PerformanceUses no external driver or ballastQuickest installationEliminates compatibility issuesLowest installation costExcellent efficacy and additionalmaintenance savingsControllable dimming systemHighest install costRequires LED driverRequires in-line fuse & socket kitAdditional safety precaution requiredMedium installation costLimited dimmingSystem compatibilitydepends on LFL ballast2Uses external driver, providingexpanded performance capabilitiesUses existing ballastExcellent efficacy

Complete OfferingInnovative DesignsTrusted ExperienceCurrent offers a broader anddeeper LED Tubes assortmentthan leading competitiors.High-performance solutions fordemanding market needs.GE invented the first linear fluorescentin 1938, and Current has transferredthat leadership to LED tubes.What features does Current offer versus the leading competitors?MoreMoreCurrent offerstotal tubeoptionsglass tubesProductsAssembled in USANoCompromiseWider BeamAngleSpecialprojects &Shorter leadtimesRight brightness,type, and materialper applicationDistributes lightbetter and eliminatesdark spotsHighestLumenoptions in T8 & T5Bright LightProvides high lightoutput for high-bayor demandingapplicationsStatements based on product information on leading competitor public USA websites.3

Current makes updating SimplerRefit Solutions from Current.It’s never been easier to upgrade from linear fluorescents toCurrent’s LED tubes. With Current’s expanding offering, there areefficient solutions for many popular applications.Integrated, ballast bypassand remote driver technology in2, 3, 4 & 8 ft lengths and U-tubes(UL Type A)(UL Type B)Shatter-resistant plasticoption to prevent breakageand downtimeGlass options fullyilluminate fixture with 270 light distribution(UL Type C)Linear Fluorescent lighting is the most prevalent light source among Commercialand Industrial buildings. LED Tube conversions are the perfect fit for any onCommercialOfficeRetail

LED replacement tubesIntegrated Plastic Tubes - Type ABaseOrderCase MOL LumensTypeType WattsCodeDescriptionVolts Qty** (In)InitialIntegrated 4ft LED Plastic Tubes (operates on Instant Start or Program Start 9LED12ET8/4/86525481900Integrated 3ft LED Plastic Tubes (operates on Instant Start or Program Start Ballast)T8InitialColorTempWattageCRI K4000K5000K6500K80 80 80 80 80 80 80 80 80 80 80 *RatedLifeL70 00070,00070,00070,000DLC YesYesYesYesYesYesYesYesYesYes-UL#Location AdditionalRating mpDampDampDampDampDampDampDampDampDampInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF Rated26544LED12ET8/3/835253615503500K80 70,000YesYesDampInstant or PRS Ballast, NSF Rated26625LED12ET8/3/840253615504000K 80 70,000YesYesDampInstant or PRS Ballast, NSF Rated26627LED12ET8/3/850253616505000K80 70,000YesYesDampInstant or PRS Ballast, NSF RatedIntegrated2ft LED Plastic Tubes (operates on Instant Start or Program Start 24135014003500K4000K80 80 70,00070,000YesYesYesYesDampDampInstant or PRS Ballast, NSF RatedInstant or PRS Ballast, NSF Rated26676LED9ET8/2/850252414005000K80 70,000YesYesDampInstant or PRS Ballast, NSF RatedIntegratedU6 Plastic TubesG131343120LED13ET8/U6/8301222.518003000K 80 50,000YesYesDampInstant or PRS Ballast43125LED13ET8/U6/8351222.518503500K80 50,000YesYesDampInstant or PRS Ballast43129LED13ET8/U6/8401222.519004000K 80 50,000YesYesDampInstant or PRS Ballast43130LED13ET8/U6/8501222.519005000K80 50,000YesYesDampInstant or PRS BallastIntegrated PET Plastic Coated Glass Tubes - Type 0 50,000-YesDampInstant or PRS Ballast, NSF Rated4820003500K80 50,000YesYesDampInstant or PRS Ballast, NSF Rated204820004000K80 50,000YesYesDampInstant or PRS Ballast, NSF Rated204820505000K80 50,000YesYesDampInstant or PRS Ballast, NSF RatedCaseQty**MOL(In)93107394 LED14ET8/G4/830CT2093107506 LED14ET8/G4/835CT2093107507 LED14ET8/G4/840CT93107510 LED14ET8/G4/850CTBaseOrderTypeType WattsCodeDescription4ft T8 LED Tube- Plastic Coated GlassVoltsWattage *Rated LifeReplacement L70 (Hrs) DLC UL#Location AdditionalRating InformationUpdated / New ProductInformation provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured underlaboratory conditions, and GE makes no warranty or guarantee, expressed or implied, that such performance will be obtained under end-use conditions.* The life rating is based on the hours of operation the lamp will provide before reaching 70% of its original rating (L70)** Minimum order quantity 6ENERGY STAR status: ENERGY STAR certified. Lamps without a “ ” are not ENERGY STAR certified.# UL 1993 Environmental Requirements for LED LAMPSLocation, damp – Exterior or interior location that is normally or periodically subject to condensation of moisture in, on, or adjacent to, electrical equipment,and includes partially protected locations.Location, dry– Location not normally subject to dampness, may include a location subject to temporary dampness, i.e., building under construction,provided ventilation is adequate to prevent an accumulation of moisture.Location, wet – Location in which water or other liquid can drip, splash, or flow on or against electrical equipment.Notes:1) Product descriptions ending in “/TP” indicate a carded blister or clamshell package nested in a tray for shelf display. Cards also designed for hook display.Get more information atwww.gecurrent.com5

LED replacement tubesIntegrated Glass Tubes - Type ABaseOrderCaseMOL LumensType Type WattsCodeDescriptionVolts Qty**(In)InitialIntegrated 4 ft LED Glass Tubes (operates on Instant Start or Program Start Ballast)T8G13181510InitialColorTempCRI*Rated LifeWattageReplacement L70 (Hrs)DLC*UL#Location AdditionalRating Information35767LED18ET8/G/4/830204824003000K80 70,000YesYesDampInstant or PRS 000K5000K80 80 80 stant or PRS BallastInstant or PRS BallastInstant or PRS Ballast35773LED18ET8/G/4/865204826006500K80 70,000-YesDampInstant or PRS Ballast35790LED15ET8/G/4/830204821003000K80 70,000YesYesDampInstant or PRS Ballast35791LED15ET8/G/4/835204822003500K80 70,000YesYesDampInstant or PRS Ballast35793LED15ET8/G/4/840204822004000K80 70,000YesYesDampInstant or PRS Ballast35797LED15ET8/G/4/850204823005000K80 70,000YesYesDampInstant or PRS Ballast35798LED15ET8/G/4/865204823006500K80 70,000-YesDampInstant or PRS Ballast34277LED10ET8/G/4/830204815503000K80 70,000YesYesDampInstant or PRS Ballast34279LED10ET8/G/4/835204816003500K80 70,000YesYesDampInstant or PRS Ballast34280LED10ET8/G/4/840204816004000K80 70,000YesYesDampInstant or PRS Ballast34282LED10ET8/G/4/850204816505000K80 70,000YesYesDampInstant or PRS BallastIntegrated 4 ft 50K Value LED Glass Tubes (operates on Instant Start or Program Start Ballast)G1311.51493107390 LED11ET8/G/4/830204816003000K80 50,000-YesDampInstant or PRS Ballast93107391 LED11ET8/G/4/835204816003500K80 50,000YesYesDampInstant or PRS Ballast93107392 LED11ET8/G/4/840204816504000K80 50,000YesYesDampInstant or PRS Ballast93107393 LED11ET8/G/4/850204817005000K80 50,000YesYesDampInstant or PRS Ballast34283LED14ET8/G/4/830204819503000K80 50,000YesYesDampInstant or PRS Ballast34289LED14ET8/G/4/835204820003500K80 50,000YesYesDampInstant or PRS Ballast34291LED14ET8/G/4/840204820004000K80 50,000YesYesDampInstant or PRS Ballast34300LED14ET8/G/4/850204820505000K80 50,000YesYesDampInstant or PRS BallastIntegrated 3 ft LED Glass Tubes (operates on Instant Start or Program Start Ballast)G131135783LED11ET8/G/3/830203614503000K80 70,000YesYesDampInstant or PRS Ballast35784LED11ET8/G/3/835203615003500K80 70,000YesYesDampInstant or PRS Ballast35788LED11ET8/G/3/840203615004000K80 70,000YesYesDampInstant or PRS Ballast35789LED11ET8/G/3/850203616005000K80 70,000YesYesDampInstant or PRS BallastIntegrated 2 ft LED Glass Tubes (operates on Instant Start or Program Start Ballast)G13835775LED8ET8/G/2/830202413003000K80 70,000-YesDampInstant or PRS Ballast35776LED8ET8/G/2/835202413503500K80 70,000YesYesDampInstant or PRS Ballast35778LED8ET8/G/2/840202413504000K80 70,000YesYesDampInstant or PRS Ballast35779LED8ET8/G/2/850202414005000K80 70,000YesYesDampInstant or PRS BallastIntegrated Glass Tubes with reveal TriGain Technology - Type ABaseOrderCaseMOL LumensInitial*Rated LifeWattageTypeType Watts Code DescriptionVolts Qty**(In)Initial Color Temp CRIReplacement L70 (Hrs) DLC Integrated 4 ft High CRI with reveal TriGain Technology LED Glass Tubes (operates on Instant Start or Program Start Ballast)G1315UL#Location AdditionalRating Information34307 tant or PRS Ballast34313 tant or PRS Ballast34316 LED15ET8/G/4/950204822505000K9070,000Integrated 3 ft High CRI with reveal TriGain Technology LED Glass Tubes (operates on Instant Start or Program Start Ballast)YesYesDampInstant or PRS BallastG131134323 nt or PRS Ballast34326 nt or PRS Ballast34332 nt or PRS BallastIntegrated 2 ft High CRI with reveal TriGain Technology LED Glass Tubes (operates on Instant Start or Program Start Ballast)G13934337 t or PRS Ballast34341 t or PRS Ballast34342 t or PRS BallastUpdated / New ProductInformation provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured underlaboratory conditions, and GE makes no warranty or guarantee, expressed or implied, that such performance will be obtained under end-use conditions.* The life rating is based on the hours of operation the lamp will provide before reaching 70% of its original rating (L70)** Minimum order quantity 6ENERGY STAR status: ENERGY STAR certified. Lamps without a “ ” are not ENERGY STAR certified.# UL 1993 Environmental Requirements for LED LAMPSLocation, damp – Exterior or interior location that is normally or periodically subject to condensation of moisture in, on, or adjacent to, electrical equipment,and includes partially protected locations.Location, dry– Location not normally subject to dampness, may include a location subject to temporary dampness, i.e., building under construction,provided ventilation is adequate to prevent an accumulation of moisture.Location, wet – Location in which water or other liquid can drip, splash, or flow on or against electrical equipment.Notes:1) Product descriptions ending in “/TP” indicate a carded blister or clamshell package nested in a tray for shelf display. Cards also designed for hook display.6Get more information atwww.gecurrent.com

LED replacement tubesIntegrated Glass Tubes - Type AInitialBaseOrderCaseMOL LumensColor**TypeType Watts Code DescriptionVolts Qty(In)InitialTempIntegrated 4 ft LED Glass T5 HO Tubes (operates on Instant Start or Program Start Ballast)T5G5 25.5 19203 LED26ET5/G/4/830204636503000KCRI*Rated LifeWattageReplacement L70 (Hrs) DLC UL#Location AdditionalRating Information80 50,000YesYesDampRequires T5 HO BallastLED26ET5/G/4/835204637503500K80 50,000YesYesDampRequires T5 HO Ballast19227 LED26ET5/G/4/840204638004000K80 50,000YesYesDampRequires T5 HO Ballast19348 LED26ET5/G/4/850204639005000K80 50,000YesYesDampRequires T5 HO Ballast19488 LED26ET5/G/4/865204638006500K80 50,000-YesDampRequires T5 HO BallastIntegrated 2 ft LED Glass T5 HO Tubes (operates on Instant Start or Program Start Ballast)G51134413 LED11ET5/G/2/830202215003000K19221580 50,000-YesDampRequires T5 HO Ballast34417 LED11ET5/G/2/835202215503500K80 50,000-YesDampRequires T5 HO Ballast34418 LED11ET5/G/2/840202216004000K80 50,000-YesDampRequires T5 HO Ballast34424 LED11ET5/G/2/850202216005000K80 50,000-YesDampRequires T5 HO BallastIntegrated 4 ft LED Glass T5 HE Tubes (operates on Instant Start or Program Start Ballast)G51334351 LED13ET5G4/830HE204619003000K34354 LED13ET5G4/835HE204619503500K80 80 50,00050,000YesYesYesYesDampDampRequires T5 HE BallastRequires T5 HE Ballast34355 LED13ET5G4/840HE204620004000K80 50,000YesYesDampRequires T5 HE Ballast34367 LED13ET5G4/850HE204620005000K80 50,000YesYesDampRequires T5 HE BallastIntegrated 3 ft LED Glass T5 HE Tubes (operates on Instant Start or Program Start Ballast)G51034371 LED10ET5G3/830HE203415003000K80 50,000-YesDampRequires T5 HE Ballast34376 LED10ET5G3/835HE203415503500K80 50,000-YesDampRequires T5 HE Ballast34401 LED10ET5G3/840HE203416004000K80 50,000-YesDampRequires T5 HE Ballast34402 LED10ET5G3/850HE203416005000K80 50,000-YesDampRequires T5 HE BallastIntegrated 2 ft LED Glass T5 HE Tubes (operates on Instant Start or Program Start Ballast)G5734403 LED7ET5/G2/830HE202210003000K80 50,000-YesDampRequires T5 HE Ballast34404 LED7ET5/G2/835HE202211003500K80 50,000-YesDampRequires T5 HE Ballast34411LED7ET5/G2/840HE202211504000K80 50,000-YesDampRequires T5 HE Ballast34412 LED7ET5/G2/850HE202211505000K80 50,000-YesDampRequires T5 HE BallastUpdated / New ProductInformation provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured underlaboratory conditions, and GE makes no warranty or guarantee, expressed or implied, that such performance will be obtained under end-use conditions.* The life rating is based on the hours of operation the lamp will provide before reaching 70% of its original rating (L70)** Minimum order quantity 6ENERGY STAR status: ENERGY STAR certified. Lamps without a “ ” are not ENERGY STAR certified.# UL 1993 Environmental Requirements for LED LAMPSLocation, damp – Exterior or interior location that is normally or periodically subject to condensation of moisture in, on, or adjacent to, electrical equipment,and includes partially protected locations.Location, dry– Location not normally subject to dampness, may include a location subject to temporary dampness, i.e., building under construction,provided ventilation is adequate to prevent an accumulation of moisture.Location, wet – Location in which water or other liquid can drip, splash, or flow on or against electrical equipment.Notes:1) Product descriptions ending in “/TP” indicate a carded blister or clamshell package nested in a tray for shelf display. Cards also designed for hook display.Get more information atwww.gecurrent.com7

LED replacement tubesType B Double-Ended LED Tubes - XLBaseOrderTypeType WattsCodeBallast Bypass - 4 ft LED XL Glass ase MOL LumensQty** 5502550InitialColorTempWattageCRI alColorTempWattageCRI 70 0070,00070,00070,00070,00070,00070,000 .9 .9 .9 .9 .9 .9 .9 .9 .9 .9 .9 .9*RatedLifeL70 (Hrs)PowerFactor50,00050,00050,00050,000 .9 .9 .9 .9DLC YesYesYesYesYesYesYes#Location AdditionalRating pDampDampDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerDouble-Ended PowerBallast Bypass Glass Tubes - Double Ended - Type BBaseOrderTypeType WattsCodeBallast Bypass - 8 ft LED Glass 3122174Ballast Bypass - 4 ft LED Glass 35LED34BDT8/G/8/840LED34BDT8/G/8/850Case MOL LumensVolts Qty** 696964000400044004400DLC ULYesYesYesYesYesYesYesYes#Location AdditionalRating InformationDampDampDampDampDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerG131693123476LED16BDT8/G4/830120-277 204821003000K 8050,000 .9YesYes DampG131693125618LED16BDT8/G4/835120-277 204821503500K8050,000 .9YesYes DampG131693125620LED16BDT8/G4/840120-277 204822004000K 8050,000 .9YesYes DampG131693125622LED16BDT8/G4/850120-277 204822005000K8050,000 .9YesYes DampG131439493LED14BDT8/G4/830120-277 204817003000K 8050,000 .9YesYes DampG131439494LED14BDT8/G4/835120-277 204817503500K8050,000 .9YesYes DampG131439498LED14BDT8/G4/840120-277 204818004000K 8050,000 .9YesYes DampG131439519LED14BDT8/G4/850120-277 204818505000K8050,000 .9YesYes DampG131193117212LED11BDT8/G4/830120-277 204816003000K 8050,000 .9Yes DampG131193117213LED11BDT8/G4/835120-277 204816503500K8050,000 .9YesYes DampG131193117214LED11BDT8/G4/840120-277 204816504000K 8050,000 .9YesYes DampG131193117215LED11BDT8/G4/850120-277 204817005000K8050,000 .9YesYes DampBallast Bypass- 3 ft LED Glass TubesG131239525LED12BDT8/G3/830120-277 203614503000K 8050,000 .9YesYes DampG131239547LED12BDT8/G3/835120-277 203615003500K8050,000 .9YesYes DampG131239554LED12BDT8/G3/840120-277 203615504000K 8050,000 .9YesYes DampG131239557LED12BDT8/G3/850120-277 203615505000K8050,000 .9YesYes DampBallast Bypass- 2 ft LED Glass TubesDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended 0Ballast Bypass - 4 ft LED Tube - PET Plastic Coated 0CTDouble Ended PowerDouble Ended PowerDouble Ended PowerDouble Ended 0,00050,00050,000 .9 .9 .9

(70K vs. 30K hrs.) Uses 43% less energy (18W and 2600 lumens vs LFL 32W and 2800 lumens) Better quality of light (Instant-On) Which LED tube is right for you? Why switch to LED tubes? LED Tubes are the fast and easy way to upgrade to LED. With Current's UL Type A, Type B and UL Type C options, you can choose the best solution for your needs.

Related Documents:

Aug 21, 2019 · philips lytecaster 344dstx-302mrex-42017-4 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 . recessed white 4" recessed downlight led, 1160 delivered lumens, 3000k, 90 cri cree lighting eaton mcgraw-edison ist-af-350-

TTL and CMOS logic 74 Series 74ls00 datasheet, 74ls02 datasheet, 74ls04 datasheet, 74ls08 datasheet, 74ls11 datasheet, 7414 datasheet, 74ls14 datasheet, 74ls20 datasheet, 74ls30 datasheet, 74ls32

your partner for tubes, pipes and accessories for the oil- and gas industry, chemical and petroche-mical industry, energy and offshore technology, paper, pharma, textile industry and automotive. With this catalogue we like to introduce you our possibilities for: Boiler Tubes / Furnace Tubes / Heat Exchanger Tubes: seamless and welded

A. Drive Bays M. Memory Fault LED B. UID Button N. UID Button C. Optical Disk Drive O. Module Power LED D. System Power LED P. SAFE TO PULL LED E. System Status LED Q. PRIMARY LED F. System FT LED R. IO Module Fault LED G. UID LED S. Fan Fault LED H. USB Connector T. PSU Fault LED I. Pull-out Tab U. DC Power Fault LED J. Power Button V .

Your Home Tube Feeding: PEG Tubes, Gastrostomy Tubes (G‐Tubes) and Jejunostomy Tubes (J‐Tubes) (TJUH) Introduction Good nutrition is an important part of your treatment, recovery, and well‐being. When you are not able to eat enough, it

1 - YUBA UNIT # 1 AIR TEMPERING HEATER, Yuba Heat Transfer Tube S/N 64-G-136-1, Design Pressure PSI Tubes 150 / Shell 150, Design Temp. F Tubes 300 / Shell 650, Test Pressure PSI Tubes & Shell 225 2 - LUMMUS FEEDWATER HEATERS, Working Pressure PSI 250 Shell / 300 Tubes,Test Pressure PSI 500 Shell / 600 Tubes, UNIT # 1 3rd, S/N H-6744-EA-3 .

Tubes-The tubes are made of seamless drawn steel, a popular size being 3 1/4 inch outside diameter which is the way all boiler tubes are measured. When tubes are installed they are pushed in through the holes in the front head which are slightly larger than the outside of the tubes, and back through the water space and

ASTM C 67 Test Method for Sampling and Testing Brick and Structural Tile. 3. ASTM C 150 Standard Specification for Portland Cement. 4. ASTM C 297 Standard Test Method for Flatwise Tensile Strength of Sandwich Constructions. 5. ASTM C 578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. 6. ASTM D 968 (Federal Test Standard 141A Method 6191) Standard Test Methods for .