Siqura A-80Firmware Version 3.2User Manual8-channel audio and contact closure card

Note: To ensure proper operation, please read this manual thoroughly before using the product and retain theinformation for future reference.Copyright 2013 Siqura B.V.All rights reserved.A-80 v3.2User Manual v1.1 (102105-1a)AIT55MW10Nothing from this publication may be copied, translated, reproduced, and/or published by means of printing,photocopying, or by any other means without the prior written permission of Siqura.Siqura reserves the right to modify specifications stated in this manual.Brand namesAny brand names mentioned in this manual are registered trademarks of their respective owners.LiabilitySiqura accepts no liability for claims from third parties arising from improper use other than that stated in thismanual.Although considerable care has been taken to ensure a correct and suitably comprehensive description of allrelevant product components, this manual may nonetheless contain errors and inaccuracies. We invite you to offeryour suggestions and comments by email via t.writing@tkhsecurity.com. Your feedback will help us to furtherimprove our documentation.More informationIf you have any comments or queries concerning any aspect related to the product, do not hesitate to contact:Siqura B.V.Zuidelijk Halfrond 42801 DD GoudaThe NetherlandsGeneralFaxE-mailWWW:::: 31 182 592 333 31 182 592 123sales.nl@tkhsecurity.comwww.siqura.comFor a full list of TKH Security Solutions sales offices, see the last page of this manual.Page 2

Contents1INTRODUCTION . 52SAFETY INFORMATION . 72.13SAFETY INFORMATION . 7PRODUCT DESCRIPTION . 113.13.24PRODUCT OVERVIEW . 11FRONT PANEL . 12INSTALLATION . 134.14.24.34.44.55POWERING THE UNIT . 13CONNECTING CABLES . 13STARTUP . 14CONNECTOR PIN ASSIGNMENTS . 14UPDATING DEVICE DEFINITIONS . 15CONNECTIONS . 175.15.26ESTABLISHING A NETWORK CONNECTION . 17MAKING AUDIO AND CONTACT CLOSURE CONNECTIONS . 19INTERFACES . 216.16.26.36.46.57WEB USER INTERFACE . 21MX/IP . 21SNMP . 21OPEN STREAMING ARCHITECTURE (OSA). 22SAP . 22ACCESSING THE INTERNAL WEB SERVER . 237.17.2SYSTEM REQUIREMENTS . 23LOGIN PROCEDURE . 238WEB PAGE FEATURES . 259WORKING WITH THE WEB PAGES . 279.1OVERVIEW . 279.2STATUS. 289.2.1 Status . 289.2.2 Measurements . 299.3NETWORK . 299.3.1 Advanced Settings . 309.4AUDIO # . 319.4.1 Advanced Settings . 339.4.2 FloodGuard . 399.5CONTACT CLOSURES. 399.5.1 Making Contact Closure Connections . 419.5.2 Advanced Settings . 419.6DEVICE MANAGEMENT . 439.6.1 General . 439.6.1.19.6.29.6.39.6.4Advanced Settings .44SNMP . 44MX . 46Auto Discovery. 47Page 3

Contents9.6.5 Firmware . 499.6.6 Reboot . 519.7USER MANAGEMENT . 529.7.1 Web Access. 529.7.2 Linux . 539.8DATE AND TIME . 549.8.1 Advanced Settings (Date and Time) . 5410APPENDIX: MULTICASTING, MULTI-UNICASTING, PORT NUMBERS. 5511APPENDIX: ENABLING JAVASCRIPT . 5712APPENDIX: TECHNICAL SPECIFICATIONS . 59Page 4

C1hapter1IntroductionDocument scopeThis manual applies to A-80 v3.2, Siqura's 8-channel audio and contact closure card.It offers detailed information on: HowHowHowHowHowtototototoinstall the unitestablish connectionscommunicate with the unitoperate the unitconfigure the unit's settingsIntended audienceThis manual is aimed at network engineers, technicians, and operators involved in theinstallation and operation of network devices, such as the A-80.Assumed skills and know-howTo work with a A-80 unit, a technician or operator must have adequate knowledge and skills inthe fields of: Installing electronic devices Ethernet network technologies and Internet Protocol (IP) Windows environments Web browsers Audio and contact closure transmissionsSpecificationsThe information given in this manual was current when published. Siqura reserves the right torevise and improve its products. All specifications are subject to change without notice.Important informationBefore proceeding, please read and observe all instructions and warnings in this manual. Retainthis manual with the original bill of sale for future reference and, if necessary, warranty service.When unpacking your product, check for missing or damaged items. If any item is missing, or ifdamage is evident, do not install or operate this product. Contact your supplier for assistance.Page 5

C2hapter2Safety InformationThis chapter contains the A-80 safety instructions.In This ChapterSafety Information . 72.1Safety InformationGeneralThe safety information contained in this section, and on other pages of this manual, must beobserved whenever this unit is operated, serviced, or repaired. Failure to comply with anyprecaution, warning, or instruction noted in the manual is in violation of the standards of design,manufacture, and intended use of the module. Siqura assumes no liability for the customer'sfailure to comply with any of these safety requirements.Trained PersonnelInstallation, adjustment, maintenance, and repair of this equipment are to be performed bytrained personnel aware of the hazards involved. For correct and safe use of the equipment andin order to keep the equipment in a safe condition, it is essential that both operating andservicing personnel follow standard safety procedures in addition to the safety precautions andwarnings specified in this manual, and that this unit be installed in locations accessible to trainedservice personnel only.Safety RequirementsThe equipment described in this manual has been designed and tested according to theUL/IEC/EN 60950-1 safety requirements.Warning: If there is any doubt regarding the safety of the equipment, do not put it intooperation.This might be the case when the equipment shows physical damage or is stressed beyondtolerable limits (for example, during storage and transportation).Important: Before opening the equipment, disconnect it from all power sources.The equipment must be powered by a SELV* power supply. This is equivalent to a Limited Powersource (LPS, see UL/IEC/EN 60950-1 clause 2.5) or a "NEC Class 2" power supply. When thismodule is operated in extremely elevated temperature conditions, it is possible for internal andexternal metal surfaces to become extremely hot.*SELV: conforming to IEC 60950-1, 60VDC output, output voltage galvanically isolated from mains. Allpower supplies or power supply cabinets available from Siqura comply with these SELV requirements.Page 7

Siqura A-80Optical Safety (A-80 /SFP)This optical equipment contains Class 1M lasers or LEDs and has been designed and tested tomeet IEC 60825-1:1993 A1 A2 and IEC 60825-2:2004 safety class 1M requirements.Warning: Optical equipment presents potential hazards to testing and servicing personnel, owingto high levels of optical radiation.When using magnifying optical instruments, avoid looking directly into the output of anoperating transmitter or into the end of a fiber connected to an operating transmitter, or therewill be a risk of permanent eye damage. Precautions should be taken to prevent exposure tooptical radiation when the unit is removed from its enclosure or when the fiber is disconnectedfrom the unit. The optical radiation is invisible to the eye.Use of controls or adjustments or procedures other than those specified herein may result inhazardous radiation exposure.The installer is responsible for ensuring that the label depicted below (background: yellow;border and text: black) is present in the restricted locations where this equipment is installed.EMCThe equipment has been tested and found to meet the CE-regulations relating to EMC, andcomplies with the limits for a Class B device, pursuant to Part 15 of the FCC rules. These limitsare designed to provide reasonable protection against interference to radio communications inany installation. The equipment generates, uses, and can radiate radio frequency energy;improper use or special circumstances may cause interference to other equipment or aperformance decrease due to interference radiated by other equipment. In such cases, the userwill have to take appropriate measures to reduce such interactions between this and otherequipment.Any interruption of the shielding inside or outside the equipment could make the equipmentmore prone to fail EMC requirements.Non-video signal lines must use appropriate shielded Cat 5 cabling (S-FTP), or at least anequivalent. Ensure that all electrically connected components are carefully earthed andprotected against surges (high voltage transients caused by switching or lightning).ESDElectrostatic discharge (ESD) can damage or destroy electronic components. Proper precautionsshould be taken against ESD when opening the equipment.Care and MaintenanceThe encoder will normally need no maintenance. In order to keep the module operating reliably,please observe the following. Page 8Prevent dust from collecting on the module.Do not expose the equipment to moisture.Keep the module within the appropriate temperature range as described in the TechnicalSpecifications section.

Safety InformationRoHS StatementGlobal concerns over the health and environmental risks associated with the useof certain environmentally-sensitive materials in electronic products have ledthe European Union (EU) to enact the Directive on the Restriction of the use ofcertain Hazardous Substances (RoHS) (2002/95/EC). Siqura offers productsthat comply with the EU’s RoHS Directive. The full version of the Siqura RoHSstatement can be viewed at www.siqura.com.Product DisposalThe unit contains valuable materials which qualify for recycling. In the interestof protecting the natural environment, properly recycling the unit at the end ofits service life is imperative.When processing the printed circuit board, dismantling the lithium battery callsfor special attention. This kind of battery, a button cell type, contains so littlelithium, that it will never be classified as reactive hazardous waste. It is safe fornormal disposal, as required for batteries by your local authority.Page 9

C3hapter3Product DescriptionSiqura A-80 is an eight-channel audio and I/O card for IP applications. This chapter introducesthe unit to you by presenting its main features.In This ChapterProduct Overview . 11Front Panel . 123.1Product OverviewGeneralThe Siqura A-80 eight-channel audio and contact closure card offers a compact solution formultiple audio and contact closure channels over IP. The A-80 can be included in almost anyexisting and new CCTV solution to add audio and contact closures to the system.ModelsThe A-80 is to be used in MC 11 or similar Siqura power supply cabinets, but it is also availableas a stand-alone module (/SA version). The /SFP version of the A-80 has a pluggable SFP slot forconnections via fiber optic cable. A range of multimode or single-mode XSNet SFP devices fitthe empty SFP slot. Front panel LEDs indicate network status, stream status (sync), and DCpower. All models have backup battery power for their clocks.AudioThe A-80 adds eight separate bidirectional audio channels to the CCTV system. The audio inputssupport either line-level or microphone–level with additional biasing to power electretmicrophones. By using RTP/RTCP in combination with network time synchronization (NTP) theaudio streams can be made lip-sync with almost any video stream.Contact ClosuresEight contact closure inputs can be configured to ‘stream’ contact closure signals to the Siqurai-NVR, for example, or to activate a signal in the API. In addition, the A-80 offers four contactclosure outputs to connect with third-party PLCs or other telemetry systems. The CC output canbe activated through the API or received CC streams.Web InterfaceConfiguration and management are simplified by the access-controlled web interface. Fullin-band control is available through Siqura ’s MX Configuration Tool Kit or the HTTP API. TheSiqura A-80 is field-upgradeable.Page 11

Siqura A-80Open Streaming Architecture (OSA)The A-80 is designed to comply with the worldwide adopted standards for streaming audio. OSAoffers standardized streaming audio and remote control. All streaming protocols are based onproven standards and tested with different vendors. A comprehensive HTTP API gives access toall controls, which makes integration with third-party equipment easy. The API is available athttp://www.siqura.com/. In addition to OSA, the A-80 supports Siqura’s unique MX protocol.CompatibilityThe A-80 is part of Siqura , a complete collection of video surveillance equipment and solutions.As such, the A-80 is compatible with Siqura video codecs/servers, IP cameras, videomanagement, network storage, and configuration software. For more information, refer tohttp://www.siqura.com/.3.2Front PanelFeatures and indicationsThe front panel of the A-80 has the following features.A-80A, B, C, DRJ-45 socket orSFPEthernet I/O, electrical or fiber12-pole combiconconnectorper connector: 2x audio input/output,2x cc input,1x cc outputStatus indicator LEDs*DCgreenDC power OK; blinks onidentification and er

Siqura A-80 Firmware Version 3.2 8-channel audio and contact closure card . Page 2 Note: To ensure proper operation, . Siqura reserves the right to modify specifications stated in this manual. . 3.2 FRONT PANEL .