EA003OPTICAL TACHOMETER CALIBRATION ADAPTERÜOPERATION MANUAL

EA003Optical Tachometer Calibration AdapterOperation ManualVersion 1.00April 2007All product names are trademarks of their respective companies

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALGuarantee and serviceTransmille Ltd. guarantees this instrument to be free from defects under normal useand service for a period of 1 years from purchase. This guarantee applies only tothe original purchaser and does not cover fuses, or any instrument which, inTransmille’s opinion, has been modified, misused or subjected to abnormalhandling or operating conditions.Transmille’s obligation under this guarantee is limited to replacement or repair of aninstrument which is returned to Transmille within the warranty period. If Transmilledetermines that the fault has been caused by the purchaser, Transmille will contactthe purchaser before proceeding with any repair.To obtain repair under this guarantee the purchaser must send the instrument in itsoriginal packaging (carriage prepaid) and a description of the fault to Transmille atthe address shown below. The instrument will be repaired at the factory andreturned to the purchaser, carriage prepaid.Note :TRANSMILLE ASSUMES NO RESPONSIBILITY FOR DAMAGE IN TRANSITTHIS GUARANTEE IS THE PURCHASER’S SOLE AND EXCLUSIVE GUARANTEEAND IS IN LEIU OF ANY OTHER GUARANTEE, EXPRESSED OR IMPLIED.TRANSMILLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIALOR CONSEQUENTIAL DAMAGES OR LOSS.Transmille Ltd.Unit 4, Select Business CentreLodge RoadStaplehurstKentTN12 0QWUnited KingdomTel :Fax : 44 0 1580 890700 44 0 1580 890711EMail : sales@transmille.comWeb : www.transmille.comTransmille Ltd.Page 2

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALTABLE OF CONTENTSGUARANTEE AND SERVICE . 2EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER . 4INTEGRATED RPM MODE FOR DIRECT CONTROL . 4EXTERNAL ADAPTER TO PROVIDE OPTICAL TRIGGERING OF TACHOMETER INSTRUMENTS . 4OPTICAL TACHOMETER CALIBRATION ADAPTER - OPERATION. 5Optical Tachometer Calibration Adapter Connection. 5Starting the Optical Tachometer Calibration Option . 5Optical Tachometer Calibration Option Operation. 6CARE & MAINTENANCE. 8Cleaning the Adapter . 8Handling Precautions . 8Servicing Information . 8Appendix A : SpecificationsTransmille Ltd.Page 3

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALEA003 Optical TachometerCalibration Adapter Complete solution calibrates optical tachometers up to 60,000 RPMComplete with adapter unit incorporating high intensity LEDEasy to useWorks with ProCal & 3000 Series Virtual Front Panel SoftwareSimply connect the adapter to the feature connector on the 3000 series calibrator, selectthe RPM mode and value and point the tachometer at the high intensity LED to performaccurate and repeatable calibration, removing the need for ad-hoc setups and de-skillingcalibration of these instrument types.Integrated RPM Mode for direct controlThe 3000 Series calibrators incorporate adedicated RPM mode to control the opticaltachometer adapterExternal Adapter to provide optical triggering oftachometer instrumentsConnects directly to the adapter interface connector on the 3000 seriescalibrator. Incorporates high intensity LED.Transmille Ltd.Page 4

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALOptical Tachometer Calibration Adapter OperationOptical Tachometer Calibration Adapter ConnectionUsing the supplied adapter connection lead (9 way ‘D’ type to 9 way ‘D’ type), connect theoptical tachometer calibration adapter to the feature connection on the front panel of the3000 series calibrator.Starting the Optical Tachometer Calibration OptionTo start the oscilloscope calibration option, press the softkey below theRPMmenu itemThermocouple simulationmode softkeyTIP : If theRPMmenu item is not displayed, press theNEXTsoftkey togo to the next menu level.Transmille Ltd.Page 5

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALOptical Tachometer Calibration Option OperationThe optical tachometer calibration option allows the user to enter a value directly in RPMand use the calibrator to control the optical tachometer adapter. The integrated LED ispulsed at the required frequency to simulate the RPM value entered.RPM SettingOutput status(On / Standby)1.Use the calibrator keypad to key in the required RPM, for example 3500 :3500ENTERNote : Valid RPM settings are from 240 RPM to 60,000 RPMEnsure the calibrator output is turned ON by pressing theOutputONkey.Note : The LED in the top left hand corner of the Output ON key will illuminate andthe display will indicate ON in the left hand corner.Transmille Ltd.Page 6

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUAL2.The optical tachometer should be pointed at the LED on the adapter with no morethan 20 angle to ensure consistent detection by the tachometer. Distance from theLED should also be restricted to within 5cm, again, for consistent detection.Distance5cm max.Optical tachometer calibration times can be significantly reduced by using the ProCalcalibration software available from Transmille which allows a pre-defined sequence of tests(known as a procedure) to be set up. This allows the computer to automatically stepthrough these tests, control the calibrator, set the correct outputs and record the amount ofdeviation in relation to the instrument’s specifications.Transmille Ltd.Page 7

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALCare & MaintenanceThe only maintenance instructions for the adapter is periodic cleaning.See below for details on the cleaning procedure and precautions for handling.Cleaning the AdapterTo keep the external enclosure of the adapter in good condition, clean the outer case witha soft cloth. Do not use any liquids in cleaning the enclosure – removal of surface dust isall that is recommended.CAUTIONDo not use cleaning fluids or solvents for cleaning as these may damage theenclosure and affect the plastic materials used in the adapter.Handling PrecautionsThe adapter is designed for mechanical stability, but should not be subjected to excessiveshock or be dropped. Transportation is recommended using the original packaging withavoidance of extreme changes of temperature.Servicing InformationThe adapter is provided certified from the factory, and uses precision components and arenot user repairable. If the adapter is damaged it should be returned to the factory for repairand recalibration.Transmille Ltd.Page 8

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTEROPERATION MANUALEA003Optical Tachometer Calibration AdapterAppendix ASpecificationsTransmille Ltd.Page 9

EA003 Optical Tachometer Adapter SpecificationsGeneral SpecificationsAdaptor connectionIndicatorsBrightnessDuty cycleAdaptor DimensionsConnectionsConnection to CalibratorConnects to male 'D' type adapter interface connector on 3000 Series front panelIncorporates red 8mm 20 Spread Ultra bright LED mounted in the adaptor case1000mcd (wavelength 660nm)20% (5:1)12.5cm x 6.5cm x 2.5cm1 x 9 way male 'D' type connectorVia supplied 9 Way male to female serial lead (straight through connection)Optical Tachometer Adaptor AccuracyRangeResolution240 to 60,000 RPM6 40003200060000180 Day Rel.%0.00291 Year Rel.%0.00302 Year Rel.%0.0036Specifications apply between 17 C and 27 C.Outside this range an allowance of 0.18 x 1 Year Spec. per C should be added.Due to continuous development specifications may be subject to change.EA003 Optical Tachometer AdapterV4.00

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL Transmille Ltd. Page 4 EA003 Optical Tachometer Calibration Adapter Complete solution calibrates optical tachometers up to 60,000 RPM Complete with adapter unit incorporating high intensity LED Easy to use Works with ProCal & 3000 Series Virtual Front Panel Software .

Related Documents:

3825-34, Chrysler 3 Adapter 3825-12, Ford EEC Adapter 3825-16, Ford ABS Adapter 3421-93, Kia Adapter 3825-11, MECS ABS Adapter 3825-13, Geo-Isuzu Adapter 3825-14, Mazda MECS Adapter 3825-15, Universal 9 Pin Adapter 3825-17, Toyota DCL 1/ Adapter 3825-18, Toyota DCL 2/ Adapter 3825-19, Mitsubishi/ Chrysler “Y” Adpater 3825-20, Nissan 1 Adapter

NOTE: If your tachometer does not function correctly when connecting the green wire to an aftermarket ignition box, such as MSD, etc., it may become necessary to use an aftermarket tachometer adapter such as MSD’s 8910 or 8920. Contact MSD for further details on their adapters. INSTALLATION INSTRUCTIONS TACHOMETER KIT

DAM-G 52 Male Adapter DAM-U 53 Male Adapter DAM-UO 53 Female Adapter DAF-N 54 Female Adapter DAF-R 55 Female Adapter DAF-GR 55 Female Gauge Adapter DAF-GG 56 Elbow Adapter DLA 57 Run Tee Adapter DTRA 57 Branch Tee Adapter DTBA 57 All dimensions are in millimeters unless othe

Calibration (from VIM3) Continued NOTE 1 A calibration may be expressed by a statement, calibration function, calibration diagram, calibration curve, or calibration table. In some cases, it may consist of an additive or multiplicative correction of the indication with associated measurement uncertainty. NOTE 2 Calibration should not be .

Host action Target needed * : Timings are given for information only, they can vary depending on the Host capabilities Calibration Data result Calibration data Calibration data Calibration data Calibration data Device initialization SPADs calibration Temperature calibration Offset calibrat

calibration. The vertical comparator was built during the year 2003. The calibration facility is designed to calibrate up to 3-m-long invar rods, both for system calibration of digital levels and for tradi-tional rod calibration. SLAC System Calibration Facility The procedure of system calibration of digital levels is described

1 Manual calibration introduction 3 1.1 Purpose 3 1.2 Manual calibration software 3 2 Manual calibration overview 3 3 Manual calibration process 4 3.1 Setup MCR program 4 3.2 Calibration pattern positioning 9 3.3 Capturing pattern image 14 3.4 Using the Synergy Calibration tool 18 3.5 Fine tuning side images 24

archaeological resource within a particular area or 'site' in order to make an assessment of its merit in context (using the HER, historic maps and other resources) Post-excavation Assessment (PXA) It is fairly unlikely that you will need to produce one of these as they are generally a planning requirement and/or for large sites with lots of finds. A post- excavation assessment report should .