Microscopy from Carl ZeissAxioplan 2 imagingThe Universal Microscope SystemMicroscopy withdigital perfection

Axioplan 2imagingAs we start a new millennium, we also enter anew age of microscopy – the age of digital technology. As with many major milestones in thehistory of microscopy, Carl Zeiss is at the forefront, leading the digital revolution. To meet thechallenges of this new age, we have createdAxioplan 2 imaging, a flexible microscope system designed for the future. An exciting singlesolution with infinite flexibility that can be tailored to every application. Computer-controlledor operated manually, this microscope not onlycaptures and stores images digitally and withbrilliant precision, it can also communicate withother systems. Axioplan 2 imaging: the highperformance, high-flexibility microscope systemthat guarantees new heights in success.So: If you want to stay in the lead in the digitalage, you need a reliable partner. One who canalways meet the latest demanding requirementsin research and routine microscopy. One who isalways up to date with the rapid developments intechnology. With more than 150 years of experience in microscope making, with unquestionedleadership in practice-oriented software and withits highly competent sales and service organization, Carl Zeiss is this partner. Turn to Carl Zeissfor solutions that ensure you accomplish thetasks of today and tomorrow – from simpleimage handling to complex image analysis problems.

MilestonesIn 1847, Carl Zeiss sold his first microscope to a scientist.Since then, the company he founded has been a leadingplayer in microscope development worldwide.Time and again, Zeiss innovations have set new standardsin research and routine microscopy.1925The Carl Zeiss company developsthe first reflected-light microscope withinfinity optics.1939LumipanA universal microscope ushersin the modern era in microscopy:the Lumipan stand.1958Sets new standards in microscope design:The Universal Research Microscope,still indispensable in many laboratories.1973AxiomatA completely new stand and legendaryquality: Axiomat. Over and above itsrevolutionary design, it features infinityoptics for all microscopical techniques.1986The infinity optics principle brought toperfection: Axioplan and Axiophot.Technical innovations and unprecedentedAxioplanergonomic advantages set new standards.2000Subject to continuous optimization and updating, thousands ofthese “pyramids” are doing excellent service around the world.Today’s top model: Axioplan 2 imaging.

2

Axioplan 2 imaging –FluorescenceHigh performance in fluorescenceSimply brilliant:must be expected of any micro-The Light Trapscope that claims to meet yourhighest expectations. With itsThe quality of a fluorescence im-optics of high light transmissionage hinges on contrast, or signal-and the precision of its innovativeto-noise ratio. However good themechanisms, the new Axioplan 2light-gathering power of the ob-imaging provides everything thatjective, the quality of the reflectedfluorescence microscopists couldlight beam or the signal selectivityever want: Perfect, high-contrastof the filter set may be, any com-images and maximum system sta-promise at the cost of contrastbility in multichannel fluorescencewould impair the system’s detec-applications.tion sensitivity and consequentlythe identification of image details.Axioplan 2 imaging solves theproblemwiththeproprietary“Light Trap”. This unparalleled CarlZeiss invention with its new filtercubes open at the rear removesstray light from the imaging beampath, thus substantially curtailingbackground noise.Stray radiation passes a dichroicmirror (2), and leaves the filter cube (1)on a direct path via the rear opening (3).The tapered mount (4) of the filter cubethen deflects it out of the beam path (5).The results: Substantially enhancedcontrast, images of greater definitionand brilliance, and higher sensitivityBeam pathwith Light Trap1344Beam pathin a conventional reflector module52

Bright And BrilliantPerfect in everydimension:The new opticsThe superbly corrected optics ofAxioplan 2 imaging guaranteeoptimal chromatically correctedillumination in the image plane.Where light intensities are verylow, an optional 5-element chromatic collector further enhancesthe illumination homogeneity. Improving color correction, it assuresmaximum excitation and, as aresult, maximum emission. Highperformance filters made to veryclose tolerances help avoid pixelshifts. The newly designed reflected-light beam path allows the system to be tailored either for besttransmission or for diffraction-limited imaging of the field diaphragm. Thanks to interchangeable diaphragm sliders, the user Human endothelium cells.Quadruple fluorescence:DAPI, Alexa 350, Alexa 488,Phalloidin-Alexa 594.Plan-Neofluar 63/1.25 oil.J. Zbaeren, Insel Hospital, Berncan select diaphragm formats ormodules.The decisive gain in contrast:FITC fluorescence micrographwithout Light Trap (1),with Light Trap (2)125

Axioplan 2 imaging –FluorescenceMultichannel fluorescence is play-With 8 positionsing an increasingly important rolein the lead :in research, whether used alone orFilters and filter turretin combination with other opticalmethods. There is a current trend,Eight filter places, easily accessiblefor example, from single channelin a compact turret without com-FISH (fluorescence in-situ hybridi-promising the full 25 mm field ofzation) to multicolor FISH, whereview: This is top performance com-combinations of up to seven fluo-bined with unequalled flexibility.rochromes yield 24 colors for auto-You can insert a wide range ofmatic chromosome analysis. Indichroic mirror-emission filter com-many research labs, different mu-binations, Optovar modules andtants of fluorescent proteins area DIC analyzer for convenientcombined with standard fluores-change. If you install the optionalcent dyes. So it is becoming moreexternal filter changer, you can useand more important to have six orup to eight excitation filters asmore positions on the filter turret.well.With Axioplan 2 imaging, youhave eight.With the Push&Clickmechanism, filter cubes arechanged within seconds.Fast access to the right filter set:the filter wheel with 8 positionsfor Push&Click filter cubes6

Number One InPerformanceAnd FlexibilityFast changeover :High-resolution four-colorbanding of human chromosomes.Dr. I. Chudoba,Institute of Human Genetics, Jena,and MetaSystems, AltlussheimPush&ClickWith so many options to choosefrom, flexibility is the key. The new,cube-mounted filter sets can bequickly removed or added to theAxioplan 2 imaging filter turret.No more screws, no problems withalignment: The practical Push&Clickmechanism ensures the filters are Metaphase. Left to right:Inverted and band-enhanced DAPIcounterstaining;RGB presentation;classified pseudocolor presentationcorrectlypositionedandheldsecurely in place. Chart of chromosome karyotypes.Comparison of DAPI counterstainingand classified chromosomes.Dr. Köhler,Applied Spectral Imaging7

Axioplan 2 imaging –FluorescenceResearch assignments pose formi-Turn minimum signalsdable challenges to both peopleinto maximum results :andZeiss opticsequipment.Axioplan2imaging brilliantly satisfies theSuppose you want to observe sig-workplace. It is the researcher’snals at a cell membrane or flowsideal partner when it comes toinside a cell, or investigate thegetting the best results.presence of GFP in, or GFP trans- demands placed on a microscopyDevelopment stadiaof C. elegans. DIC.Prof. Schnabel, BraunschweigUniversity of Technologyport between, specific cell compartments. No matter whether the1–5C. elegans. GFP-labeledneurons.H. Hutter, MPI Heidelbergemission signal comes from a fluo-1Differentiation bybetter contrast :DIC with a memoryFor studies in developmental biology using DIC microscopy, the maxi-2mum in resolution and contrast isonly just good enough. To achievethis, all parts of the instrumentmust be perfectly tuned to eachother – as is the case withAxioplan 2 imaging. For everyobjective, there is a speciallyrescence-labeled antibody, an ion-matched DIC slider, including onedepicting dye or another specificwith Sénarmont contrasting. Oncemarker, it is too faint to be detec-the DIC slider has been set, thetable with optics of any but theobjective will keep the setting inhighest performance. Objectivesmind.from Carl Zeiss feature highest NAAxioplan 2 imaging comes with(limited only by the laws ofan extensive range of ICS objec-physics), ideal chromatic correctiontives of renowned, continuouslyand image flattening, and the veryoptimized Zeiss quality, with su-best transmission properties forperb contrast and resolution. Onevisible light, UV and IR imaging. Inof them will be ideally suited toshort: maximum performance foryour current application, whateverevery application.it may be.834

Focus On ResearchPerfect specimenCorrect excitation :protection :AttoArc 2The high-speed shutterWith AttoArc 2 you can control theThe microscopy of live objects isintensity of the excitation light viaparticularly demanding. In order tothe brightness of the lamp source.get the best images, specimensAs a result, you automatically getmust be treated with the leastsignals of the intensity needed forpossible damage. The motorizeddocumentation. In computer-con-high-speed shutter of Axioplan 2trolled multichannel fluorescenceimaging provides a superb advan-work, the light intensity will betage in fluorescence work. Withautomatically adjusted from chan-shutter speeds down to a fewnel to channel. Whether with man-microseconds, it is the perfect so-ual or digital control, AttoArc 2lution for GFP images of living sys-will always provide signals of opti-tems. Simply leave the light sourcemum strength. And this meanson and control exposure time withperfect results.the shutter. This reduces bleachingand phototoxicity of the specimen.Fast but gentle :The SoftStop functionWith the new SoftStop function,you can change reflector modulesand objectives within fractions of asecond. This will save valuabletime, especially in automated processes. In addition, a special algorithm prevents switching oscillations otherwise inevitable at suchspeeds – a feature that is easy on5your microscope and your specimens.Electronic dimmerfor high-pressure lamps:AttoArc 29

Axioplan 2 imaging –ICS OpticsInfinity optics were designed in theearly 1930s on the basis of AugustPlan-NeofluarobjectivesKöhler’s concepts and calculations.But it took the invention of ICS(Infinity Color-corrected System) in1986 to make this type of opticsthe core of a complete range ofinstruments.ICS optics aim at achieving thebest possible performance withthe least possible number of optical elements. As every optical element contributes to limiting theFluarobjectivessystem’s light transmission, minimizing the number of optical components means maximizing theoverall optical performance.ICS optics and SI (System Integration) stand design have broughtabout visible improvements inoptical performance with regard toimage contrast, brightness anddetail resolution. Today, after morethan a decade, the ICS concept isC-Apochromatobjectivesstill unsurpassed. With continuedupgrading of the imaging elements and advanced manufacturing processes, ICS optics have become indispensable for providingthe high apertures and long working distances needed for the applications of today and tomorrow.Plan-Apochromatobjectives10

Limited OnlyBy The Laws Of Physics1) Mycelia.Grocott silvering.Prof. Höfler, MunichUniversity of Technology2) Salivary gland of a drosophila.GFP labeling3) Cell nuclei and mitosis.Triple fluorescence.Dr. Beensen,Friedrich Schiller University, Jena4) Embryo of C. elegans. DIC.Prof. Schnabel, BraunschweigUniversity of Technology1AllroundersIf flexibility and a wide range of techniques are required, universalsemi-apochromatic Plan-Neofluar objectives are the answer. Withtransmission from the near UV, semi-apochromatic correction, excellent image flattening, optimum working distances, low strain and highnumerical apertures, they are ideal for brightfield, darkfield, phasecontrast, DIC, polarization and fluorescence. High contrast makesthem perfect for capturing sharp, clear images for post processing andsubsequent analysis.2Photon countersThe Fluar range is designed for maximum transmission and photon collection. Constructed from special optical glass, these objectives featurehigh numerical apertures and high contrast, ensuring the best lighttransmission throughout the visible spectral range down to the nearUV. Fluar objectives are your best choice if you want to capture eventhe faintest fluorescence signal.3Immersion specialistsFor the examination of living organisms and immersion preparations,you need high-performance objectives capable of optically compensating differing refractive indices and volumes of the media involved.These requirements are best met by the special family of MultiImmersion Plan Neofluar objectives or the apochromatically correctedC-Apo family for the most demanding applications. Both will alwaysgive you brilliant images.4Top performersThanks to the combination of best color correction with highestnumerical apertures, Plan-Apochromat objectives provide the ultimatein resolution, image definition, and rendition of subtlest color differences. With their large apertures, they deliver outstanding brightfieldand DIC images and perform brilliantly in fluorescence microscopy.11

Axioplan 2 imaging –The Digital ImagingPlatformtor, this allows you to expand yoursystem with video cameras, digitalcompact cameras or other advanced imagers – meaning thatyour system is one hundred percent future-safe.Digital micrography :Image quality withAxioCam perfectionAxioCam Axioplan 2 imaging –12the ideal combination of high-endFor top-quality digital images,camera and microscope – providewhether in color or black&white,you with a digital imaging work-AxioCam is the optimum imagerstation unparalleled in perfectionfor Axioplan 2 imaging. A cameraand convenience. No films, no timedesigned by Carl Zeiss to meet thelost with processing – the imagesrequirements of microscopy oneare available immediately on a PChundred percent. Perfect imagescreen, perfectly resolved with upquality is ensured by a sophisticatedto 3900 x 3090 non-interpolatedelectronic system composed ofpixels per color channel.first-grade devices, including a 14-The programmable resolution ofbit analog-to-digital converter. TheAxioCam not only ensures perfectcamera is connected via glass fiberdocumentation but also allows youcable so as to be isolated fromto digitize the maximum availableambient interferences. Cooled by aoptical resolution without anyPeltier element, the CCD imagelosses. This produces brilliant digi-sensor is kept free from disturbingtal image files with the resolutioneffects, so that even long expo-of traditional transparencies – idealsures needed for very faint fluores-for printed publications and yourcences produce images of excel-notes, workbooks or records. Oflent quality. AxioCam is the perfectcourse, they can be incorporateddigital choice for brightfield andinto your web site or sent by e-DIC micrography. It is amazingmail.how well it performs with single-AxioCam can be used with a wideand multichannel fluorescence; inrange of tubes and adapters forthe black&white configuration, itmicrography. Together with a use-satisfies even the most exactingful device called the port replica-demands.Overall viewSelective enlargement

Brilliant CapturesDual capabilityAdded flexibility:with many benefits :The dual video adapterThe multi-imaging tubeIn addition to the binocular orWant to use a video camera and amulti-imaging tube, the dual videodigital camera in parallel? Split upadapter provides another opticalfluorescence signals according toport. For wavelength selection, youwavelength and document thecan easily replace the neutral beamimage at the same time? The newsplitter with a dichroic mirror, usingmotorized multi-imaging tube,the Push&Click mechanism just aswith ports for two cameras, makeswith the multi-imaging tube.it possible. Equipped with a soft-That means that you can assembleware control interface, with XYthe exact system you need for yourcamera positioning to ensure per-specific application.fect image overlay and with a neutral beam splitter mirror in thePush&Click module, which youcan replace with a dichroic mirror,the multi-imaging tube opens upany documentation road you wantto go – with full automation.Cat's cerebellum.Silver staining.J. Zbaeren,Insel Hospital, BernTop:Axioplan 2 imagingwith motorized multiimaging tube anddual video adapterBottom:Axioplan 2 imagingwith motorizedmulti-imagingtube13

Dual TV tubeAxioplan 2 imaging –MotorizationReflector turretWhether manually controlled orPrecisely in focus :motorized, Axioplan 2 imagingThe third dimensionlets you decide precisely whichRevolving nosepiececonfiguration suits your routine orMaximum resolution governs theresearch tasks best.third dimension as well: Axioplan 2imaging combines minute, dis-Simple and clever :crete focusing steps with motor-SmartContrastized speed, satisfying the mostCondensersZ conexacting requirements of 3D imagPrecise images require precise mi-ing. Manual focusing is supportedcroscope settings. Every time youby programmable step sizes andchange an objective or a contrast-separate coarse and fine focusinging technique, you need to read-knobs – a first for a motorizedjust the light source, brightness,microscope. Precision and repeata-filters and diaphragms. Axioplan 2bility at their finest!Filter wheels andfield diaphragmimaging saves you much of theeffort and time involved: The newAutomated convenience :SmartContrast feature and theMotorizedmotorized DIC condenser allow youscanning stagesto save your favored settings andautomatically retrieve them timeMotorized scanning stages openand again – for every objective andup almost unlimited possibilities:every contrast technique. For ex-Let Axioplan 2 imaging scanample, change from 40 x DIC toyour specimens overnight; detect,40 x FITC – at the touch of a singleselect, locate and group prede-button!fined patterns with the intelligentimage processing software; effectchromosome karyotyping; producea high-resolution scan of yourspecimen, control the microscoperemotely, or automatically track thegrowth of live cells beyond themargin of the visual field. Microscopy unlimited in time and space!14The graphic operator interface of AxioVision Control

PerfectionThe Automatic WayHigh-speedshutter,integratedPersonalized settings :8-place filter wheelThe function keysTo facilitate setting, you, as well asThe motorizedcomponents ofAxioplan 2 imaging Motany other user, can store up totwenty individual, frequently usedsettings in separate user menusand activate them when needed.trolSelect the field diaphragm setting,the phase annulus, the objective,and the intensity of illumination,and save the information behind ascreen button or – with even fasteraccess – behind a key of your keyboard. Simply strike this key toSupports yourFlexible choice :reproduce the settings in next tosuccess :Manual or motorizedno time. In micrography, with everyRepeatabilityfunctionsshot you can save the exact set-The brilliance of images is one ofIt is up to you to decide whichmicroscope mechanisms in a data-the two decisive quality criteria infunctionsbase. Reproducibility at a key-microscopy. Reliable repeatabilityshould be motorized or coded.is the other. With its coded andWhatever you decide or set ismotorized stands and compo-saved by the software – whethernents, Axioplan 2 imaging notyou make manual settings on aonly ensures exact documentationmotorized component or select aof your experiments but alsofunction on the graphic user inter-allows all settings made to beface and see the microscope homeexactly reproduced.in on the selected position. Here isAxioVisionControl, a basic soft-a concept p

Fluorescence Multichannel fluorescence is play-ing an increasingly important role in research, whether used alone or in combination with other optical methods. There is a current trend, for example, from single channel FISH (fluorescence in-situ hybridi-zation) to multicolor FISH, where combinations of up to seven fluo-rochromes yield 24 colors .

Related Documents:

ZEISS GT2 3D 1.4 ZEISS GT2 3D Short 1.5 ZEISS Individual Single Vision 1.6 ZEISS 3DSingle Vision 1.7 SOLA HDV 1.8 SOLA Elan HDV 1.9 SOLA Elan HD 1.10 SOLA Elan Short 1.11 SOLAOne HD 1.12 Compact ULTRA HD 1.13 AO Easy HD 1.14 SOLA ATL HD Single Vision 1.15 Customized Wrap Rx Only Lenses ZEISS Individual

Carl Zeiss Sports Optics User Manual Gebrauchshinweise Mode d’emploi Modo de empleo Carl Zeiss Sports Optics 711 Moorefield Park Drive, Bldg. E . The key to this system is the Optimal Power Setting as determined by the ZEISS Ballistic Calculator. This will provide you with the ideal

ZEISS provides a broad spectrum of precision lenses for better vision; from endless-frame and easy-to-handle options with high visual performance to optimally individualised solutions. GT2 3D Gradal Individual EyeFit Gradal Plus ZEISS Progressive Superb ZEISS Progressive Individual 2 ZEISS Progre

fluorescence microscope (Zeiss Axiovert 40 CFL; Carl Zeiss Inc). Images were captured on a cooled CCD camera. Image acquisition and analysis were performed and visualized by fluorescence, and images were obtained on a PC computer using a Zeiss Axiovert 40 CFL fluorescence microscope with Zeiss Zhen microscope soft-ware (Zeiss Inc).

new age of microscopy - the age of digital tech-nology. As with many major milestones in the history of microscopy, Carl Zeiss is at the fore-front, leading the digital revolution. To meet the challenges of this new age, we have created Axioplan 2 imaging, a flexible microscope sys-tem designed for the future. An exciting single

MULTIPHOTON LASER SCANNING MICROSCOPY Introduction to Multiphoton Laser Scanning Microscopy Carl Zeiss LSM 510 NLO 8-6 B 40-055 e 09/02 8.2 Introduction to Multiphoton Laser Scanning Microscopy Multiphoton laser scanning microscopy (MPLSM) has become an important technique in vital and deep tissue fluorescence imaging.

Course Catalog. ZEISS Training and Education Expand Your Possibilities Practical microscopy training has a long tradition at ZEISS. The first courses were . Coffee Grounds, 750x Crossbeam, Todd Simpson, Western University, Canada, tsimpson@uwo.ca. 10. Introduction to Scanning Electron Microscopy (SEM)

BEST Zeiss Individual PAL Zeiss Individual SV BETTER Zeiss GT2 3DV Zeiss 3D SV GOOD Zeiss GT2 3D / short Electronic Measuring The wave of the future All dispensaries will have one As common as the corneal reflex pupillometer Takes frame measurements Takes POW measurements High degree