LiebertLiebert Liqui-tect Leak Detection and ReportingMonitoring SolutionsCOMPREHENSIVE DETECTION OFWATER BASED LEAKS IN CRITICAL SPACESAccurate, Reliable Systems ForDetecting, Locating And ReportingLeaks In Computer Rooms,Telecommunications CentersAnd Other Facilities HousingSensitive Electronic Equipment.

WATER DAMAGE CAN BE A CATASTROPHICEVENT FOR COMPUTERS AND NETWORKSYour critical computing, communications or process control facility could be exposed to water — and you may not even knowabout it until it's too late. Water damage due to leaking pipes, sprinkler systems, leaking roofs and other causes is far morecommon than realized.What risks exist in your facility?2Leaking RoofCan allow substantialamounts of water to enterthe shelter over time.Unattended FacilityRemote communicationsshelters require monitoringto protect against damagingwater leaks.FloodingWater from the outsidecould flood the insideof the structure.Flat Roof Water PenetrationStanding water can make itsway into the critical space,causing water damage.Clogged DrainDrainage systems designed toremove water can become aserious liability if blocked orotherwise closed.

PlumbingAny water piping located nearcritical equipment poses a riskif leaks develop. sprinkler systems waste systems condensate piping chilled water piping condenser water pipingLiebert is theone source thatcan help youavoid theseproblems witha full range ofleak detectionand reportingsystems.UPStationGXT ACINPUTBATTERYUPSONBYPASSUPStationGXT ACINPUTBATTERYUPSONBYPASSUPStationGXT ACINPUTBATTERYUPSONBYPASSUPStationGXT ACINPUTBATTERYUPSONBYPASSRoom Located Below GradeAreas located below ground level aresubject to water seepage from outsideas well as leaks from the floor above.HumidifierDrip pans for humidifiers or airconditioning units can overflowif not regularly checked.3

LIEBERT LIQUI-TECT — YOUR BESTSOLUTION FOR LEAK DETECTIONLiebert leak detection systems deliver quick and accurate notification at the first sign of trouble. They also offer the ability tointerface with your monitoring and building management systems to provide the broadest possible range of communication.Liebert Liqui-tect leak detectionsystems provide accurate reporting4of leaks below the floor, above theceiling or at the perimeter of a roomin critical facilities. These reliablesystems provide immediate warningand precise location, allowing you tofind and correct a leak beforemoisture can damage computers,wiring connections or othersensitive electronics.Liebert Liqui-tect leak detectionsystems are ideal for a variety oflocations, including: Computer rooms.Liebert Liqui-tect Monitoring SystemTwo Channel Direct-Read Leak DetectionLiebert brings you the ultimate in leak detection and reporting capabilities.The Liebert Liqui-tect Monitoring System provides two channels for monitoringdifferent areas with direct-read at the control unit location, as well as the abilityto communicate with Liebert's SiteScan Web enterprise monitoring system or abuilding management system. Large-scale networkcontrol centers. Telecommunications facilities. Satellite ground stations andother specialized datacommunications nodes.User-Friendly — The Liebert Liqui-tect Monitoring System features aneasy-to-use liquid crystal display (LCD) panel with readout of normal andalarm conditions, as well as leak location. Display and measurement modulesare contained in a single compact package.Installation Flexibility — The slim profile of the monitoring panel enables Industrial process control rooms.the Liebert Liqui-tect Monitoring System to be mounted on a wall or Any location where water canrecess-mounted within a wall. A choice of two different panels sizes providescause problems.flexibility to meet application needs. The panels are made of metal toApplications:accommodate secure conduit fittings and protect components against Glycol, condenser water andenvironmental debris.chilled water cooling piping leak. Humidification feed water piping. Condensate pumps and drains. Unit and ceiling auxiliary drip pans. Overhead piping.Two Channel Capability with Accurate Sensing — The Liebert Liqui-tectMonitoring System has two independent channels to monitor two differentareas. Each channel can monitor up to 5000 feet of Liebert LT500Y leak cable.Single-person mapping makes it easy to configure within the critical space.The system determines the location of water on the detection cable andreports the distance from the Liqui-tect Monitoring System, in feet or meters.Within seconds of detection, the measurement is flashed on the displaypanel, allowing you to take prompt action to correct the leak and preventdamage. To ensure proper protection, the system continuously monitorsoperation, signaling system normal, leak detected and cable fault.

Outstanding Features And Monitoring VersatilityLiebert Liqui-tect 460 (zone sensor)Liebert Liqui-tectZone And Point LeakDetection SensorsLiebert Liqui-tect 410 (point sensor)Liebert Liqui-tect zone and point leakdetection systems install quickly andwork simply for reliable warning ofpotentially hazardous water leaks.Liqui-tect leak detection sensors offer5many outstanding features, including:Standard Dry-Contact OutputSensors are easily monitored byLiebert LT500Y LeakDetection Cable offersdurable design for accuratesensing and the ability to readand report the exact position of theleak. Liebert leak detection cables have amulti-wire design for precise identification ofmoisture and signaling. Rugged, durable materials resistcorrosion and abrasion for long cable life. The cable's non-kinkdesign makes it easy to position around equipment. After a leakis corrected, the cable sheds liquid quickly for an easy returnto normal conditions.numerous monitoring systemsand equipment such as Liebertenvironmental equipment via localalarm contact. Also compatible withLiebert's SiteScan Web enterprisemonitoring system and thirdparty equipment.Dual Output RelaysLiebert LT500Y leak detection cable is designed for easyinstallation and unlike other sensing cables does not exhibitmemory. This means that the installation goes in easier and doesnot require additional attention to how flat the cable is laying onthe floor. Likewise, mating connectors on each end makeinstallation and removal simple.Two independent outputs provideadded flexibility to signal a localalarm panel, a remote buildingmanagement system or externalequipment such as a waterExtra lengths of cable can be added to the end of the cable or anyspot along the length of the cable where mating connectors arefound. The thermally bonded cable is rated at 176 F (80 C) and isplenum rated. UL-listed for safe operation, LT500Y leak detectioncable is available in 15, 35 and 50 feet lengths.shut-off valve.Supervised OperationSensors constantly monitor for leaks,internal fault and power failure,warning of any abnormal conditions.Easy InstallationSeparate power and signal wiressimplify circuitry needs. Mountingbrackets allow for sensor heightadjustment and leveling (Liqui-tect410). Convenient kits are availablepre-packaged with sensor, cable andhold down clips (Liqui-tect 460).Liebert Liqui-tect 410 sensor offersleak detection at critical points undera raised floor. Two corrosion-resistantgold-plated probes detect moistureand immediately signal the monitoringsystem, allowing fast action to be takenbefore mission-critical equipmentis damaged.Liebert Liqui-tect 460 sensor provideszone detection of leaks up to 100 feet.Designed for use with Liebert LT500Y leakdetection cable, the Liqui-tect 460 is theideal solution for perimeter sensing orserpentine coverage of small areas.Selectable modes of operation provideflexible alarming options and protectionfor the cable. Selectable alarm delaysminimize false-positive conditions. Topcover LEDs primarily provide statusindication, but the LEDs also ensure thesensor is easily located under raised floors.If obtained in a kit, cables are available inlengths of 20, 25, 30, 35 and 45 feet.

THERE IS A LIEBERT LEAK DETECTIONSYSTEM TO MEET THE NOTIFICATIONNEEDS OF ANY SITEChannelOneLiebert Liqui-tect MonitoringSystem — Two Channel Direct-ReadLeak Detection Cable LayoutChannel OneLIQUI-TECTPANELAC - 5ChannelTwoChannelTwo6COMPUTERAC1COMPUTERWhen used with the Liebert Liqui-tect panel, LiebertLT500Y leak detection cable is laid in a continuousAC4pattern around potential leak points located throughoutthe room. Up to 5,000 feet of leak detection cable canbe connected to each channel.ChannelTwoAC - 2Channel OneAC - 3Liebert Leak Detection Systems can beconfigured to match the protectionneeds of any site.Liebert LT500Yleak detection cableLiebert Liqui-tect 410 Point LeakDetection ConfigurationTypical installation of a Liebert Liqui-tect 410 leakLiebert Liqui-tect 460 Zone LeakDetection ConfigurationThe Liebert Liqui-tect 460 uses flexible cable for zonedetection system used to monitor the space surroundingmonitoring. Here the system is shown connecteda Liebert Deluxe System /3 precision air conditioning unit.directly to a Liebert Deluxe System/3 precision airconditioning unit. Cable should be placed 2 to 6 feetaway from the equipment being monitored. Two holddown clips should be used every 6 to 8 feet.

Leak Detection:Just Part Of An Overall Critical Facility Monitoring StrategyLiebert Liqui-tect leak detection systems are designed to work seamlesslywith Liebert's SiteScan Web enterprise monitoring system, a web-based sitemonitoring and control solution for computer support equipment and othercritical facility applications. Liebert interface hardware allows connection ofthe leak detection controls to the enterprise monitoring system.7SiteScan Web Server(Windows Platform)TCP/IP(Ethernet)SiteScan Web Clients(Web Browsers)The Liebert Liqui-tect Monitoring System'scontrol unit incorporates a built-in liquidcrystal display (LCD) panel which providesa readout of operating conditionsincluding alarms and leak locations.SiteGate-ESiteLink4 Liebert to LiebertIGM UnitsLiqui-tectLiebert's SiteScanWeb monitoringsystem cangraphicallyrepresent your leakdetection layout in2-dimensional and3-dimensionalfloorplans.

TOTAL CONFIDENCE INTHE DECISION YOU'VE MADELiebert Liqui-tect Leak Detection and ReportingNo organization in the world today has a better understanding of exactly what it takes to keep criticalinformation and industrial processes operating continuously than Liebert.It starts with your local Liebert Representative, Distributor or Reseller. We are the onlycompany in this business that maintains such a strong local presence on a national andinternational basis. This resource, coupled with our broad product line, gives Liebert the abilityMonitoring SolutionsL I E B E R T CO R P O R AT I O N1050 DEARBORN DRIVEP.O. BOX 29186COLUMBUS, OHIO 43229800.877.9222 PHONE (U.S. &CANADA ONLY)614.888.0246 PHONE (OUTSIDE U.S.)614.841.6022 FAXto create a "tailored solution" that will meet your protection needs precisely and efficiently.With your purchase of a Liebert product, you are buying into a company that stands behind itsproducts. You are also aligning yourself with an organization that has a reputation for qualityand reliability that is second to none.In the systems protection business it's when you need someone to count on that you find outwhether you’ve made the right choice. Liebert customers — many of them with us for over threedecades — already know how good their decision was.VIA LEONARDO DA VINCI 8ZONA INDUSTRIALE TOGNANA35028 PIOVE DI SACCO (PD)ITALY39 049 9719 111 PHONE39 049 5841 257 FAXEMERSON NETWORK POWER ASIA PACIFIC7/F., DAH SING FINANCIAL CENTRE108 GLOUCESTER RD, WANCHAIHONG KONG852 25722201 PHONE852 28029250 FAXLIEBERT WEB SITEhttp://www.liebert.com24X7 TECH SUPPORT800 222 5877 PHONE614 841 6755 (OUTSIDE U.S.)The day your critical operations arethreatened by excessive heat, powerproblems or other risks is no time tofind out if a "simple" solution tosystem protection will work. LetLiebert help you make the smartdecision about assuringreliability in your highavailability facilities.While every precaution has been taken to ensure accuracy andcompleteness in this literature, Liebert Corporation assumes noresponsibility, and disclaims all liability for damages resultingfrom use of this information or for any errors or omissions. 2003 Liebert Corporation. All rights reserved throughoutthe world. Specifications subject to change without notice.All names referred to are trademarks or registered trademarksof their respective owners. Liebert and the Liebert logo are registered trademarksof the Liebert Corporation.The Emerson logo is a trademark and service markof Emerson Electric Co.SL-31500 (R10/04)Printed in USA

a Liebert Deluxe System /3 precision air conditioning unit. THERE IS A LIEBERT LEAK DETECTION SYSTEM TO MEET THE NOTIFICATION NEEDS OF ANY SITE 6 Liebert Liqui-tect 460 Zone Leak Detection Configuration The Liebert Liqui-tect 460 uses flexible cable for zone monito

Related Documents:

Liebert GXT 10kVA, Liebert GXT2U and Liebert Nfinity Liebert IntelliSlot Web Card-LB - compatible with: Liebert NX and Liebert Hinet UPS models Liebert IntelliSlot Web Card-LBDS - compatible with these Precision Cooling units: Liebert DS , Liebert X

Liebert HPC L . Liebert HPC S . Emerson’s Thermal Management Data Centre Product Portfolio . Liebert CRV Liebert XDV . Liebert PCW Liebert PDX Digital Scroll XDH. Evaporative Air Handlers/Room . Cooling . Knürr DCD Knürr DCL . 35 . Liebert DM . Liebert HPS . Rack and . In Row . Liebert DSE . Room/Perimeter

Liebert Nform Software Frequently Asked Questions Yes, by adding the Liebert MultiLink shutdown license, Liebert Nform can be setup to send shutdown commands to Liebert MultiLink 1.5 clients. Yes. Liebert can custom build templates for your UPSs to work with Liebert Nform. No, Liebert Nform c

Liebert PDX Floor-Mount Unit Liebert MC Microchannel Condenser Liebert EconoPhase Economizer The Liebert EconoPhase pumped refrigerant economizer is compatible with the Liebert PDX and Liebert MC to improve thermal management and control, while drastically cutting energy costs and lowering p

Liebert NXr Series 30KVA to 200KVA (380V) 2 Today, you need a power infrastructure . Liebert NXr to provide the same level of reliability you have come to expect from the Liebert NX UPS series. 4 The best investment you can make in a UPS system: Efficiency, . Liebert NXr Liebert NXr Li

The Liebert DSE direct expansion cooling system comprises four primary components: the Liebert DSE indoor computer room air conditioning (CRAC) unit, the Liebert MC micro-channel outdoor condenser, the Liebert EconoPhase pumped refrigerant economizer and Liebert iCOM control with thermal syste

The Liebert GXT3-5000RT208, Liebert GXT3-6000RT208 and the Liebert GXT3-6000RTL630 contain no user-serviceable parts except the internal battery pack. The Liebert GXT3-10000RT208 and the Liebert GXT3-8000RT208 contain no user-serviceable parts except the internal battery pack and the Power Module.

Compatible with Liebert DS, Liebert CW, Liebert Challenger 3000 and Liebert XD precision cooling systems (downflow and upflow) Challenges Indirect piping and control are more complex Higher initial capital costs Added water use for cooling tower Atlanta Chicago Seattle Fluid Economizer liebert CW or Ds with Air Economizer