ROOM AIR CONDITIONER

3y ago
46 Views
3 Downloads
6.54 MB
39 Pages
Last View : 6d ago
Last Download : 3m ago
Upload by : Luis Wallis
Transcription

Before using your air conditioner, please readthis manual carefully and keep it for future reference.ROOM AIR CONDITIONERMulti-Zone Mini SplitHEAT PUMP AIR CONDITIONERBefore using your air conditioner, please readthis manual carefully and keep it for future reference.Please read this installation manual completelybefore installing the product.If the power cord is damaged, replacement workshall be performed by authorised personnel only.Installation work must be performed in accordancewith the national wiring Standards by authorisedpersonnel only.Contact an authorised service technician forrepair, maintenance or installation of this unit.

CONTENTSSAFETY PRECAUTIONSWarning .2Caution .2INSTALLATION INSTRUCTIONSSelecting installation place.3Wall-mounted type .3Accessories .4Four-way cassette type .9Duct & Ceiling type .15Ceiling and Floor type .21Floor and Standing type(Console).24Outdoor unit installation .28REFRIGERANT PIPE CONNECTIONRefrigerant pipe connection .29ELECTRICAL WORKElectrical work . .30AIR PURGINGAir purging with vacuum pump .35Safety and leakage check .36TEST RUNNINGTest running .37Read This ManualInside you will find many helpful hints on how to install and test the air conditioner properly.All the illustrations and specifications in the manual are subject to change without prior notice for productimprovement. The actual shape should prevail.CAUTIONContact an authorised service technician for repair or maintenance of this unit.The appliance shall be installed in accordance with national wiring regulations.This appliance is not intended for use by persons(including children) with reducedphysical, sensory or mental capabilities, or lack of experience and knowledge, unlessthey have been given supervision or instruction concerning use of the appliance by aperson responsible for their safety.Young children should be supervised to ensure that they do not play with the air conditioner.Do not operate your air conditioner in a wet room such as a bathroom or laundry room.Installation work must be performed in accordance with the national wiring standards byauthorised personnel only.1

SAFETY PRECAUTIONSRead the follow SAFETY PRECAUTIONS carefully before installation.Electrical work must be installed by a licensed electrician. Be sure to use the correct ratingof the power plug and main circuit for the model to be installed.Incorrect installation due to ignoring of the instruction will cause harm or damage.The seriousness is classified by the following indications.WARNINGThis symbol indicates the possibility of death or serious injury.CAUTIONThis symbol indicates the possibility of injury or damage to property.The items to be followed are classified by the symbols:Symbol with background white denotes item that is PROHIBITED from doing.WARNING1) Engage dealer or specialist for installation. If installation done by the user is defective, it will cause waterleakage, electrical shock or fire.2) Install according to this installation instructions strictly. If installation is defective, it will cause waterleakage, electrical shock or fire.3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall,water leakage, electrical shock or fire.4) Install at a strong and firm location which is able to withstand the set ,s weight. If the strength is not enoughor installation is not properly done, the set will drop and cause injury.5) For electrical work, follow the local national wiring standard, regulation and this installation instructions. Anindependent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect foundin electrical work, it will cause electrical shock or fire.6) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted onthe terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.7) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board coveris not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock.8) When carrying out piping connection, take care not to let air substances other than the specifiedrefrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressurein the refrigeration cycle, explosion and injury.9) Do not modify the length of the power supply cord or use of extension cord, and do not share thesingle outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.CAUTION1) This equipment must be earthed and installed with earth leakage current breaker. It may cause electricalshock if grounding is not perfect.2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks andaccumulates at surrounding of the unit, it may cause fire.3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, watermay enter the room and damage the furniture.4) The appliance shall be installed in accordance with national wiring regulations.5) Do not operate your air conditioner in a wet room such as a bathroom or laundry room.6) An all-pole disconnection device which has at least 3mm clearances in all poles , and have aleakage current that may exceed 10mA, the residual current device (RCD) having a rated residualoperating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiringin accordance with the wiring rules.2

INSTALLATION INSTRUCTIONS1. Wall-mounted typeSelecting installation placeMore than 15cmRead completely, then follow step by step.Indoor unitMore than 12cmDo not expose the indoor unit to heat or steam.More than 12cmSelect a place where there are no obstaclesin front or around the unit.Make sure that condensation drainage canbe conveniently routed away.More than 2.3mDo not install near a doorway.Fig.1Ensure that the space on the left and rightof the unit is more than 12cm.Use a stud finder to locate studs to prevent unnecessary damage to the wall.The indoor unit should be installed on the wall at a height of 2.3 metres or more from the floor.The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.Any variations in pipe length will/may require adjustment to refrigerant charge.There should not be any direct sunlight. Otherwise, the sun will fade the plastic cabinet andaffect its appearance. If unavoidable, sunlight prevention should be taken into consideration.Outdoor unitMore than 30cmIf an awning is built over the outdoor unit toprevent direct sunlight or rain exposure,More than 30cmmake sure that heat radiation from thecondenser is not restricted.Ensure that the clearance around the backMore than 60cmof the unit is more than 30cm and left side ismore than 30cm. The front of the unit shouldhave more than 200cm of clearance and theMore than 200cmconnection side (right side) should have moreFig.2than 60cm of clearance.Do not place animals and plants in the path of the air inlet or outlet.Take the air conditioner weight into account and select a place where noise and vibrationwill not be an issue.Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.Rooftop installation:If the outdoor unit is installed on a roof structure, be sure to level the unit.Ensure the roof structure and anchoring method are adequate for the unit location.Consult local codes regarding rooftop mounting.If the outdoor unit is installed on roof structures or external walls, this may result inexcessive noise and vibration, and may also be classed as a non serviceable installation.3

INSTALLATION INSTRUCTIONSTools needed for installation:Level gaugeScrewdriverElectric drill,Hole core drill ( 65mm)Flaring tool setSpecified torque wrenches: 1.8kgf.m, 4.2kgf.m,5.5kgf.m, 6.6kgf.m(different depending on model No.)Spanner (half union)Hexagonal wrench (4mm)Gas-leak detectorVacuum pumpGauge manifoldUsers manualThermometerMultimeterPipe cutterMeasuring tapeAccessoriesNumberQ ty/one unitName of Accessories15-81Installation Plate2Plastic Expansion Sheath(depending on models)3Self-tapping Screw A ST3.9X25(depending on models)4ConnectingpipeAssemblyLiquid sideGas side5-86.359.529.5212.715.9Parts you must purchaseConsult the technicianfor the proper size.5Remote controller1678Self-tapping Screw B ST2.9X10OptionalpartsRemote controller holderSeal (for cooling& heating models only)29Drain Joint (for cooling& heating models only)Transfer connector ( Packed with the indoor unit or1101112outdoor unit, depending on models )(NOTE: Pipe size differ from appliance to appliance.To meet different pipe size requirement, sometimesthe pipe connections need the transfer connectorto install on the outdoor unit .)Magnetic ring(Hitch it on the connective cable between indoorunit and outdoor unit after installation.)Cord protection rubber ring(If the cord clamp can not fasten the cord for the small sizeof the cord, please use the cord protection rubber ring(supplied with accessories) to wrap on the cord, then fix itwith the cord clamp.)11Optional part(one piece/one indoor unit)Optional part(1-5 pieces for outdoorunit, depending onmodels)Optional part(one piece/one cable)1(on some models)Note: Except the above parts provided, the other parts needed during installation you must purchase.4

INSTALLATION INSTRUCTIONSMor2e t han1 2 cmMore than 15cmM or e th an12 cm1More1 2 c m th a n3M or e th an12 cmAi r fil te rerA ir fi ltAi r fil te rAi r fil te r45 re t han1 2 cmMo10c re thamnAir outMore than 60cmRemotecontroller6thareMo cm03nAerA ir fi ltRemotecontrollerMoretha0n20cMo6 0 r e thcm anmCBLoop g.3CAUTIONSThis illustration is for explanation purposes only.The actual shape of your air condtioner may beslightly different.Copper lines must be insulated independentlyCAUTIONUse a stud finder to locate studs to preventunnecessary damage to the wall.A minimum pipe run of 3 metres is requiredto minimise vibration & excessive noise.Two of the A, B and C directions should befree from obstructions.5

INSTALLATION INSTRUCTIONSIndoor unit installation(wall-mounted type)Correct orientationof Installation Plate1. Fit the Installation Plate1. Fit the installation plate horizontallyon structural parts of the wall withspaces around the installation plate.2. If the wall is made of brick, concreteor the like, drill five or eight 5mm diameterholes in the wall.Insert Clip anchor forappropriate mounting screws.3. Fit the installation plate on the wallwith five or eight type “A” screws.Fig.4Note:Fit the Installation Plate and drill holes in thewall according to the wall structure and indoorunit dimensions and the correspondingmounting points on the installation plate. TheInstallation Plate may be slightly differentaccording to the different models of indoorunit. See Fig.5 for example.(Dimensions are in “mm” unless otherwisestated.)RInstallation plate45Left rear siderefrigerantpipe hole 6545H120mm ormore to wallW120mm ormore to wallRight rear siderefrigerantpipe hole 65Model AMounting 0100115LRH160WModel BIndoor unit outlineL150mm or more to ceilingInstallation plateR120mm ormore to wall120mm ormore to wallLeft rear siderefrigerantpipe hole 6545R(Right)10045L(Left)710x250HIndoor unit dimensionmm(WxH)150mm or more to ceilingLIndoor unit outlineWModel CFig.56Right rear siderefrigerantpipe hole 65

INSTALLATION INSTRUCTIONS2. Drill a hole in the wallWall1. Determine hole positions according to thediagramdetailed in Fig.5. Drill one (1) hole( 65mm) slanting slightly to outdoor side.2. Always use wall hole conduit whendrilling metal grid, metal plate or the like.Outdoor5-7mmIndoorFig.63. Connective Pipe and DrainageInstallationDrainage1. Run the drain hose sloping downward. Donot install the drain hose as illustrated inFig.7.Do not put the end ofdrain hose into water.Do not block water flow by a rise.2. When connecting extension drain hose,insulate the connecting part of extensiondrain hose with a shield pipe, do not letthe drain hose slack.Fig.7Connective pipe installation1. For the left-hand and right-hand piping,remove the pipe cover from the side panel.2. For the rear-right-hand and rear-left-handpiping, install the piping as shown in Fig.10.3. Fix the end of the connective pipe. (Referto Tightening Connection in REFRIGERANTPIPING CONNECTION)Fig.8Rear-right pipingRight-hand piping4. Piping and wrappingBundle the tubing, connecting cable, and drainhose with tape securely, evenly as shown in Fig.11.Because the condensed water from rear of theindoor unit is gathered in ponding box and ispiped out of room. Do not put anything else inthe box.CAUTIONConnect the indoor unit first, then theoutdoor unit.Do not allow the piping to let out fromthe back of the indoor unit.Be careful not to let the drain hose slack.Heat insulated both of the auxiliary piping.Be sure that the drain hose is located atthe lowest side of the bundle. Locatingat the upper side can cause drain panto overflow inside the unit.Never intercross nor intertwist the powerwire with any other wiring.Run the drain hose sloped downward todrain out the condensed water smoothly.Rear-left pipingLeft-hand pipingFig.9Fig.10Indoor unitConnectivecablePonding boxPipe roomConnectivepipeWrapping beltDrain hoseFig.117

INSTALLATION INSTRUCTIONS4. Indoor unit installation1. Pass the piping through the hole in thewall.2. Put the upper claw at the back of theindoor unit on the upper hook of theinstallation plate, move the indoor unitfrom side to side to see that it is securelyhooked (see Fig.12).3. Piping can easily be made by lifting theindoor unit with a cushioning materialbetween the indoor unit and the wall.Get it out after finish piping.4. Push the lower part of the indoor unit upon the wall, then move the indoor unitfrom side to side, up and down to checkif it is hooked securely.Fig.121 drive 2 1 drive 3 1 drive 4 1 drive 5Max. Length for all roomsMax. Length for one indoor unitMax. height different between OU higher than IUindoor and outdoor unitOU lower than IUMax. height different between indoor m15m10m10m10m10m

INSTALLATION INSTRUCTIONS2.1Selecting installation site2. Four-way cassette typeWhen the conditions in the ceiling are exceeding 300C/ 860F and a relative humidity of 80%, or when freshair is inducted into the ceiling, an additional insulationis required (minimum 10 mm / 0.4in thickness,polyethylene foam).ACCESSORIESCheck if the following accessories are included withyour unit.211X341X2X1) Select an installation site where the followingconditions are fulfilled and that meets yourcustomer's approval.-2X651X1X 1X71X8-1X9104X-4X1 Remote controller2 Batteries3 Remote controller holder (on some models)4 Tapping screws (M3 10mm) (on some models)5 Installation and owner's manual6 Paper pattern for installation (on some models)7 Metal champ (on some models)8 Drain hose (on some models)9 Expansible hooks (on some models)10 Installation hooks (on some models)-2)Where optimum air distribution can be ensured.Where nothing blocks air passage.Where condensate water can be properly drained.Where the false ceiling is not noticeably on anincline.Where sufficient clearance for maintenance andservice can be ensured.Where there is no risk of flammable gas leaking.The equipment is not intended for use in apotentially explosive atmosphere.Where piping between indoor and outdoor unitsis possible within the allowable limit.(Refer to theinstallation manual of the outdoor unit.)Keep indoor unit,outdoor unit,inter unit wiring andremote controller wiring at least 1 meter awayfrom televisions and radios.This is to preventimage interference and noise in those electricalappliances.(Noise may be generated dependingon the conditions under which the electric waveis generated,even if 1 meter is kept.)When installing the wireless remote controller kit,the distance between wireless remote controllerand indoor unit might be shorter if there arefluorescent lights who are electrically started inthe room.The indoor unit must be installed as faras possible away from fluorescent lights.Ceiling heightInstall this unit where the height of bottom panelis more than 2.5m / 8.2ft so that the user cannoteasily touch.Optional accessories3) Use installation hooks for installation.Checkwhether the ceiling is strong enough tosupport the weight of the indoor unit.If there isa risk, reinforce the ceiling before installingthe unit.Space required for installation see the figurebelow (:air flow direction)This indoor unit requires installation of an optionaldecoration panel.9

INSTALLATION INSTRUCTIONSRelation of ceiling opening to unit andinstallation hook g.133 647/25.47in2523/20.59in1570/22.44in21)Preparations before 0/11.4in2.212545/21.45in570/22.44in3 Unit: mmUnit: mmAir inletAir outlet12345678Fig.14Installation hook pitch dimensionsIndoor unit dimensionsdecoration panel dimensionsRefrigerant pipingInstallation hook ( 4)Ceiling opening dimensionsHanger bracketFalse ceilingAdjust the position to ensure the gaps betweenthe indoor unit and the four sides of falseceiling are even. The indoor unit's lower partshould sink into the false ceiling for 24mm/0.95in.1224mm0.95in12Fig.161210Indoor unitFalse ceilingFig.17

INSTALLATION INSTRUCTIONS2.3NOTE: Installation is possible with a ceiling dimensionof 600 mm / 23.62in(marked with * ) . However,to achieve a ceiling-panel overlapping dimensionof 15 mm / 0.59in, the spacing between theceiling and the unit should be 20 mm / 0.

Multi-Zone Mini Split HEAT PUMP AIR CONDITIONER. 1 CONTENTS . Do not operate your air conditioner in a wet room such as a bathroom or laundry room. 6) An all-pole disconnection device which has at least 3mm clearances in all poles , and have a leakage current that may exceed 10mA, the residual current device (RCD) having a rated residual .

Related Documents:

system room air conditioner. We are sure you will nd your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions. To avoid the risks that are always present when you use an electrical

Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner. After installing, the consumer must operate the air conditioner correctly according to this manual,keep a suitable storage for maintenance and moving of the air conditioner in the future. There must be an air-break switch.

The air conditioner can be easily moved in the room. In the moving process, ensure that the air conditioner is in the upright position and should be placed on a at surface. Do not install and use the air conditioner in the bathroom or other humid environments.

A Word From Haier America Product Registration Thank you for buying a dependable, energy saving and easy-to-operate Commercial Cool air conditioner. This manual contains useful information for you to maintain, operate, install and safely use your air conditioner. Your air conditioner cleans, cools and dehumidifies the air in

Thank you for choosing the Whynter SNO portable air conditioner. You have bought one of the best portable air conditioners available today. Follow the instructions given in this booklet to obtain the very best performance from your portable air conditioner and take full advantage of the many advance features that your portable air conditioner .

to this manual,keep a suitable storage for maintenance and moving of the air conditioner in the future. There must be an air-break switch. Check the connecting cables and pipes carefully, make sure they are correct and firm before connecting the power of the air conditioner. T 3.15A 250V T 20A 250V Properly ground the air conditioner into the .

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATIO N SPLIT-TYPE ROOM AIR CONDITIONER CS78421-548-754 IMPORTANT N OTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. Owner’s Manual Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS78421 .

Creating an economy that harnesses artificial intelligence (AI) and big data is one of the great opportunities of our age. This Sector Deal is the first commitment from government and industry to realise this technology’s potential, outlining a package of up to 0.95bn of support for the sector, which includes government, industry and academic contributions up to 603m in newly allocated .