DL8000Product Data SheetD301255X012April 2020DL8000 PresetThe DL8000 Preset is a rugged electronic preset thatprovides precise custody transfer batches for petroleum,industrial chemicals, and other products. It acceptsvolumetric and mass inputs from turbine, Coriolis,ultrasonic, or other flow measurement devices using singleor linearized meter factors. (Pulse-generating meters arerecommended for improved valve closure accuracy.)The DL8000 also performs density, temperature, andpressure corrections using the latest standards andaccurately calculates delivered volumes at standardconditions (60 F, 15 C, 20 C, or user-selectable) usingdouble precision math. The DL8000 can control and blendup to four products sequentially or simultaneously (ratioblending). It can control up to 10 additives through meteredinjection and can store up to 30 recipes for blending.Density CorrectionThe DL8000 accepts density signals as a frequency, 4–20mA, or through a communications device. It accepts inputsfrom a flowing density meter (such as a Micro Motion frequency densitometer or a Micro Motion Coriolis meter).The DL8000 corrects observed density to standardconditions and calculates the temperature and pressurevolume correction factors.DL8000 Preset(Class I, Zone 1 Version)Remote Automation SolutionsTemperature CompensationThe DL8000 can accept an input from an Analog Input orRTD device. It then calculates a temperature volumecorrection factor in accordance with the followingstandards:Hydrocarbon Standards API MPMS Chapter 11.1 (1980) / API2540 (1980) /ASTM D1250 / ANSI D1250 / IP200Tables: 5A, 5B, 5D, 6A, 6B, 6C, 6D, 23A, 23B, 23D, 24A,24B, 24C, 24D, 53A, 53B, 53D, 54A, 54B, 54C, 54DAPI MPMS 11.1 (2004) / ASTM D1250-04 / IP200/04ISO 91.1 (1992)ISO 91.2 (1991) / IP3 (1988)Tables: 59A, 59B, 59D, 60A, 60B, 60DGPA TP27 (2007) (supersedes TP-25) / API MPMSChapter 11.2.4Tables: 23E, 24E, 53E, 54E, 59E, 60EAPI ASTM-IP 1952Tables: 53, 54Ethanol Standards ABNT NBR 5992:2009OIML R22 (1973)DL8000 Preset(Class I, Div. 2 Version)

DL8000April 2020Pressure CompensationThe DL8000 can accept a 4–20 mA signal from a pressuretransducer and compensate flow calculations for volumetricdue to pressure in accordance with the following standards: API MPMS 11.1 (2004) / ASTM D1250-04 / IP200/04API MPMS 11.2.1API MPMS 11.2.2API MPMS 11.2.1(M)API MPMS 11.2.2(M)Pulse FidelityThe DL8000 monitors dual pulse inputs for integrity inaccordance with the following standards: ISO 6551-1982 and BS 6439-1983API Petroleum Measurement Standard, Chapter 5.5,level B and Institute of Petroleum Standard, IP 252.76,Part XIII, Section 1, Level B.Meter Factor LinearizationThe DL8000 can perform linearization of meter factors and Kfactors using up to 12 points to ensure accuracy over theentire range of flow.ReportingThe DL8000 generates reports in compliance with NISTHandbook 44 – 2006 Edition and 2003 Update, with NCWMPublication 14, and API MPMS Chapter 12.2.2.Other Features Archival storage of 200 transactions with up to fourbatches each and 450 alarms.Storage of the last 1000 weights & measures events (inaccordance with NIST Handbook 44).Integral Weights & Measures switch.Independent permissive sensing AC power.Digital valve control with automatic high flow raterecovery.Independent temperature compensation methods forindividual products.Automatically sensing or user-entered values forthermal expansion and linear equation.User-entered vapor pressure of light hydrocarbons.OperationsThe DL8000’s user-friendly multi-language display promptsthe operator through the entire loading or unloadingsequence, assuring a safe and reliable operation.2LoadingThe loading sequence starts after the operator connects thesafety circuits, selects a recipe, enters a preset quantity, andpresses the Start button. The DL8000 automatically turns onthe required product pumps and additive injectionequipment and opens the digital flow control valves.A low-flow start sequence can be initiated to reduce staticbuild-up when delivering petroleum products. To keeploading time to a minimum, the DL8000 automaticallymaintains the highest possible flow rate the system candeliver. When additives are present, the maximum flow rateis 2700 units/minute. Three different flow profiles for eachrecipe provide maximum system flexibility regardless of themeter size. When certain recipes require small percentagesof one or more components, you can configure theprogrammable flow profiles to automatically deliver smallpercentage component(s) only during the high flow stage ofthe delivery.As the end of the batch sequence approaches, thecomponent streams slow to a pre-defined low-flow/stopflow rate. The high-speed digital valve control algorithm,working in conjunction with the linear digital control valve,ensures a smooth, repeatable, low-flow/final stop withoutline shock.To assure product quality, you can program an automaticsingle product line-flush sequence at the end of the deliveryto flush the loading arm with a single base product.UnloadingThe unloading process requires that the container (truck orrail car) is completely emptied of its contents. A pumpassisted gravity transfer is often sufficient for the task.However, in unloading applications, custody transfermeasurements can be used to check against the expectedquantity on the bill of lading.The unloading sequence starts after the operator connectsthe safety circuits, selects a recipe, and presses the Startbutton. The DL8000 displays a series of preparatorymessages (“Prebatch Testing” and “Line Pack Delay”). As theunloading begins, the program updates the Unload screen toindicate the quantity of fluid unloaded.The unload process continues until one of the followingevents occurs: The unload reaches the maximum preset quantity, orThe operator presses STOP to pause the unload, orThe container empties (determined by the activation ofa low pressure, low-flow, or no flow alarm).The Start, Pause, Resume, and Stop controls available at theDL8000’s keypad display and are critical to the unloadingprocess. The operator can pause an unload process, allowcrude to drain from the sides of the container and collectnear the outlet, and resume the unload process with a finalStart-Stop cycle.www.Emerson.com/RemoteAutomation

DL8000April 2020Data CommunicationsBlend RecipesMemory allows up to 30 blend recipes. Each recipe hasindividual totalizers and is highly configurable, providingmaximum flexibility.LinearizationMulti-point linearization is programmable with up to 12points. The DL8000 automatically interpolates between the12-meter factor setpoints to assure system accuracy overthe required flow ranges.Vapor RecoveryMeasures the amount of returned or recovered vapor duringthe loading of light hydrocarbons, and computes the Netdelivered for billing purposes. This feature is available formass delivery only and the delivered quantity will be equal tothe preset amount.In addition, GPA TP-15 allows the DL8000 to calculate andmaintain the back pressure above the vapor pressure duringloading. This reduces vapor pressure loss and emissions.Metered Additive InjectionMeasures and controls the additive amount injected into theproduct stream for up to ten additives. The injection site canbe selected as either upstream or downstream, and theadditive amount can be included in total or in addition to thedelivered quantity.DanLoad 6000 Protocol SupportThe DL8000 supports all terminal automation commandsnecessary for terminal operation and some for terminalautomation configuration. This allows you to multi-dropyour existing DanLoad 6000s with the DL8000 withoutchanges to the host.Swing Arm Position DetectionThe DL8000 allows swing arm safety circuit operation, andyou have the option to select which side (one, two, or both)is applicable per circuit.AlarmsThe DL8000 offers comprehensive alarms for blendingsystems. You can define each alarm action for no action,display only, close relay contact, stop loading process, orlock the unit. Built-in programmable alarm conditions arealso user-selectable. You can also configure the referencebase temperature for compensation corrections.Data SecurityData is secured with a 4-digit user-defined access code. Allcalibration data is secured with the access code and a wiresealable mechanical security switch that is integrallymounted in the DL8000 keypad.www.Emerson.com/RemoteAutomationThe DL8000 has three built-in communication ports. Theunit can support up to three additional ports (via optionalcommunications cards) for a total of six ports. The built-incommunication ports are: Local Operator Interface (RS-232D) – LOI.Ethernet – Comm1.EIA-232 (RS-232) – Comm2.The Local Operator Interface (LOI) port’s standard RJ-45connector provides an EIA-232 (RS-232D) link between theCPU and a PC. Use ROCLINK 800 Configuration software toconfigure the CPU, extract data, and monitor its operation.All DL8000 ports support Modbus slave protocol; masterprotocol is supported on all but the LOI and Ethernet ports.Communications ModulesYou can install up to three additional communicationmodules in the DL8000 to provide ports for communicatingwith a host computer or other devices. The DL8000accommodates the following module types, in anycombination: EIA-232 (RS-232).EIA-422/EIA-485 (RS-422/RS-485).Dial-up modem.I/O ModulesThe DL8000 supports a variety of I/O modules. You can addup to nine optically isolated I/O modules as needed to satisfya wide variety of field I/O requirements. Available modulesinclude: Alternating Current Input/Output (AC I/O)Advance Pulse Module (APM) with densitometerprocessingAnalog Inputs (AI)Analog Outputs (AO)Discrete Inputs (DI)Discrete Outputs (DO)Discrete Output Relay (DOR)HART Input/Output (a maximum of 5 modules)Pulse Inputs (PI) – High or Low speedRTD Inputs (RTD)Note:CE approved I/O configurations are shown in theApprovals section of the specifications table.Product OptionsThe DL8000 product options consist of a Class I, Zone 1flameproof version and a Class I, Division 2 Type 4 version.Both versions contain the same keypad and display.The Class I, Zone 1 version includes a cast aluminum casingwith sixteen stainless steel front cover bolts (M10 – 1.5metric) that secure the lid to the housing. With the frontcover bolts removed, the lid hinges down to reveal theelectronic compartment. It is flame-proof (in accordancewith Class I, Zone 1, Groups IIB) and weatherproof (rated3

DL8000April 2020IP66). The viewing window in the enclosure lid is made fromnon-glare glass.Measurement CanadaThe Class I, Division 2 version includes a 14-gauge stainlesssteel box with 12-gauge stainless steel mounting flanges.The door is made of .090-inch-thick aluminum and is securedto the box via a stainless-steel piano hinge and two stainlesssteel spring latches. The latches include features forpadlocking or installing wire seals. The assembly includes adoor stop that locks the door in position at approximately120 degrees from the closed position. The viewing windowin the enclosure door is made from scratch / UV resistantpolycarbonate/acrylic blend (PC/PMMA). The keypad bezel ismounted to the front of the door and is made from UVresistant polycarbonate. The assembly is rated by CSA as aType 4 enclosure.Measurement Canada approves the following firmware anduser program versions:The operator keypad is the same for both versions andprovides 18 rugged, Hall-effect push keys which areimpervious to chemicals commonly associated withpetroleum applications. A sealable Weights and Measuresswitch provides security to flow measurement parameters.The keypad accepts alphanumeric characters.Measurement Canada is available for the DL8000. TheMeasurement Canada version of the DL8000 consists of aCPU loaded with a Measurement Canada-approvedfirmware, a power module, and 9 communications and/orI/O modules housed in either cast aluminum casing orstainless-steel box with keypad and LCD display. DL8000 firmware version 2.52Liquid Calcs version 2.32Transaction History version 2.36Printer version 2.33Additives version 2.30Batching version 2.36Keypad Display Version 2.36Note:This approval does not include API 1952 – Tables53 and 54.The liquid crystal display (LCD) is the same for both versionsand provides an 8-line by 40-column message area foroperator interface. The display uses a photo sensor andtemperature sensor which can be set to automatically adjustcontrast and backlighting for optimal viewing.Light-emitting diodes (LEDs) display the status of alarms,operating mode, and permissive powers. LEDs are located tothe right of the display on both versions.4www.Emerson.com/RemoteAutomation

DL8000April 2020DL8000 Common SpecificationsProcessorType32-bit microprocessor based on the Motorola MPC862 Quad Integrated CommunicationsController (PowerQUICC ) PowerPC processor running at 65 MHzMemoryBoot Flash256 KB for system initialization and diagnosticsFlash16 MB for firmware imageSRAM2 MB for historical data logs and configurationBattery BackupSynchronous DRAMUser-replaceableTypeSanyo 3 V CR2430 lithiumNormal use life10 years while power is applied to unitBackup life1 year minimum while maintaining SRAM and RTCdata and no power is applied to unitShelf life10 years (jumper disengaged)32 MB for firmware execution and execution memoryTime FunctionsClock Type32 KHz crystal oscillator with regulated supply, battery-backed, Year/Month/Day andHour/Minute/SecondClock Accuracy0.01%Watchdog TimerHardware monitor expires after 3 seconds and resets the processorCommunicationsOn BoardEIA-232 (RS-232)PortEthernet PortLOI PortModules (optional)EIA-232 rson.com/RemoteAutomationTypeSingleMaximum DataRate115.2 k bps10BASE-T twisted pair. IEEE multi-segment 10 MB/second basebandEthernet.MaximumSegment100 m (330 ft)TypeEIA-232D (RS-232D) StandardMaximum DataRate115.2 k bpsTypeSingleMaximum DataRate115.2 k bpsTypeSingleMaximum DataRate115.2 k bps5

DL8000April 2020Dial-Up ModemModuleNote:TypeSingleMaximum DataRate115.2 k bpsFor more information about optional communications modules, refer to ProductData Sheet ROC800: COM.Inputs/OutputsOn BoardModules (optional)Board TemperatureAccuracy1% typical, 2% maximumVoltage MonitorAccuracy0.75% typical, 1% maximumAnalog Input-124 channels, 12 bits of resolution. For more information, refer toProduct Data Sheet ROC800: AI.Analog Input-164 channels, 16 bits of resolution. For more information, refer toProduct Data Sheet ROC800: AI.Alternating CurrentI/O6 channels. For more information, refer to Product Data Sheet ROC800:ACIO.Advance PulseModule4 channels, 4 single or 2 dual (one configurable as a densitometerinput and one as a pulse output). For more information, refer toProduct Data Sheet ROC800: APM.Analog Output4 channels. For more information, refer to Product Data SheetROC800:AO.Discrete Input8 channels. For more information, refer to Product Data Sheet ROC800:DI.Discrete Output5 channels. For more information, refer to Product Data SheetROC800:DO.Discrete OutputRelay5 channels. For more information, refer to Product Data Sheet ROC800:DOR.HART Input/Output4 channels, each capable of communications with up to 5 HARTdevices (when in input multi-drop mode). Supports up to 5 HARTmodules in slots 1-5. For more information, refer to Product Data SheetROC800: HART2.Pulse Input2 channels, user-selectable high speed or low speed per channel. Formore information, refer to Product Data Sheet ROC800: PI.RTD Input2 channels. For more information, refer to Product Data Sheet ROC800:RTD.PowerRequirements115 to 240 V ac ( 10%/– 15%), 50 to 60 Hz, 1-phase 30-watt nominalPhysicalKeypad18 rugged, Hall-effect push keys which are impervious to chemicals commonly associatedwith petroleum applications. A sealable Weights & Measures switch is incorporated into thefront panel to provide security to flow measurement parameters.DisplayA single, 8-line by 40-column super-twist LCD display. Status LEDs identifying alarm,permission power, and operational mode (Auto or Manual).WiringSize 12 to 22 AWG for terminal blocks6www.Emerson.com/RemoteAutomation

DL8000April 2020EnvironmentalTemperatureOperating–20 C to 65 C (–4 F to 149 F)Certified by NMI–25 C to 55 C (–4 F to 131 F)Note:Storage(non-operating)Class I, Zone 1 version only–30 C to 80 C (–22 F to 176 F)Relative Humidity5 to 95 %, non-condensingRadiated/Conducted ImmunityMeets requirements of IEC 61326 Electrical Equipment for use in industrial locationsClass I, Zone 1 Version SpecificationsPhysicalConstructionCast aluminum enclosure with sixteen stainless steel front cover boltsDimensionsHeight330 mm (13 inches)Width355 mm (14 inches)Depth366 mm (14.4 inches)Weight34 kg (75 pounds)Wiring AccessCenter50 mm (2 in.) female NPSM; normally used for all DC signal (meter pulse, RTD,analog, communication, or status/control) cablingLeft25 mm (1 in.) female NPSM; normally used for AC power input and ACstatus/control signalsRight25 mm (1 in.) female NPSM; normally used for meter pulse, RTD,communication, or analog signals when separate signal routing is requiredCSA CUSCertified by CSA as Models W40161 per CSA certification number 1859870ApprovalsProduct Markings forHazardous LocationsProduct Markings: Ex db IIB T6 Gb (Ta 40 C to 65 C) IP66Class I, Zone 1, AEx db IIB T6 GbEvaluated per ApprovalStandardsCCOEANSI/IEC 60529:2004ANSI/UL 60079-0-2013ANSI/UL 60079-1-2005-2015CAN/CSA-C22.2 No 0-M91CAN/CSA-C22.2 No 94-M91CAN/CSA-C22.2 No. 60079-0-15CAN/CSA-C22.2 No. 60079-1-16CAN/CSA-60529:05CSA Std C22.2 No 142-M1987CSA Std C22.2 No 213-M1987UL 50 (11th Ed.)UL 916 (3rd Ed.)UL Std. No. 1604 (3rd Ed.)Certified by Government of India as Model W40176 per certification numberP386710/1. Valid from 17-Oct-2016 to 17-Oct-2021Product Markings: Ex d IIB T6 Gb (Ta -40 C to 65 C)www.Emerson.com/RemoteAutomation7

DL8000April 2020KTLEvaluated per ApprovalStandardsAnnouncement No. 2019-15 of Ministry ofEmployment and LaborIEC 60529No. 2015-021902-01Certified by KTL: (Korea Testing Laboratory)Model: W40176Certification Number: 15-KA4BO-0207XShall be used with Certification Number: IECEx SIR08.0019X Issue No. 5Product Markings:Ex d IIB T6-40 C Ta 65 C (-20 C Ta 65 C for LCD Display)IP66CE / ATEXEvaluated per ApprovalStandardsAnnouncement No. 2013-54Certified by SIRA as Model W40176 per certification number IECEx SIR08.0019XCertified by SIRA as Model W40176 per certification number SIRA08ATEX1063XProduct Markings: Ex db IIB T6 Gb IP66(Ta -40 C to 65 C)II 2 GNote:0081Temperature range for LCD Display is -20 C T 65 CEvaluated per ApprovalStandardsProduct Marking forMetrologyMeasurement(Industry)CanadaCertified by Measurement Canada as Model W40161 per certification numberAV-2426CProduct Markings: Class I, Zone I, Group IIB IP66 (-40 to 65 C)NTEPCertified by NTEP as Model W40161 & W40201 per certificate number 08056A1Evaluated per ApprovalStandards8IEC 60079-0:2011 Ed. 6IEC 60079-l :2014-06 Ed. 7EN 60079-0:2012EN 60079-1:2014NIST Handbook 44 (2010)NCWM Publication 14 (2010)www.Emerson.com/RemoteAutomation

DL8000April 2020NMi(MID Standards)Certified by NMi as DL8000 per certificate number TC7661Valid I/O Configurations for MID Approval: To maintain CE approval, you can only use the following I/O modulesconnected to the valid I/O types as shown in the table below.Review the corresponding certificates to ensure full compliance.I/O ModulesI/O Type 1I/O Type 2AI-12PressureDensityDIFeedback SignalsRS 485CommunicationRTDTemperatureDOControl SignalsAPMPulse In (level B)HARTTemperatureAC I/OControl Signals(output)Evaluated per ApprovalStandardsMiscellaneous ApprovalsFeedback Signals(input)OIML R117-1 Edition 2007 (E)WELMEC guide 8.8EACCertified by EAC per certificate number TC RU C-US.GB05.B.01094 Valid from17-04-2015 to 17-04-2020INMETROCertified by UL do Brasil as Model 40176 per certification number UL-BR17.0354X Valid from 13-Jun-2017 to 12-Jun-2020Product

API MPMS 11.1 (2004) / ASTM D1250-04 / IP200/04 API MPMS 11.2.1 API MPMS 11.2.2 API MPMS 11.2.1(M) API MPMS 11.2.2(M) Pulse Fidelity The DL8000 monitors dual pulse inputs for integrity in accordance with the following standards: ISO 6551-1982 and BS 6439-1983 API Petroleum Measurement Standard, Chapter 5.5,

Related Documents:

Enter Project Name / User Guide Preset Browser The Preset Browser lets you search for and load presets. Open the Preset Browser from the Preset Menu. S EARCH FOR A PRESET BY NAME Type any part of a preset's name. Search results appear in a list below. Click the small arrow to expand or collapse a folder in the list. To expand or

Use the following procedures to get started with presets. Create a PDF preset 1. Click the Preset. tab. FrameMaker Publishing Server Reusable publishing through presets 8 2. Click Add New PDF Preset. The PDF Preset dialog appears. 3. Configure options as needed. 4. Click . Save. Modify a preset 1.

another inReach device. Each message you send includes your location details. Sending a Preset Message. Preset messages are messages that you created at inreach.garmin.com. Preset messages have predefined text and recipients. 1 Select Preset. 2 Choose a preset message, and select Send. 2 Bluetooth Connected Features. inreach.garmin.com. inreach .

calibrate ROC800-Series Remote Operations Controllers, DL8000 Preset, FloBoss 103 & 104, FloBoss 107, and FloBoss 500-Series Flow Managers. ROCLINK 800 is designed for ease of use. Dropdown menus simplify accessing the functions provided by the software. Dialog boxes and dropdown lists help to direct selections and data entry.

This paper demonstrates Emerson’s capabilities to deploy secure, reliable and robust wireless solutions for both field instrumentation and plant applications. 2 Technical Note 00840-0200-6129, Rev AA Emerson Wireless Security September 2017 Emerson Wireless Security 1.0 Introduction This purpose of this document is to fully describe the Emerson Wireless Security Defense in Depth strategy for .

This instruction manual includes installation, adjustment, maintenance, and parts ordering information for the Fisher L2 liquid level controller. Do not install, operate or maintain an L2 Liquid Level Controller without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personalFile Size: 324KBPage Count: 16Explore furtherFisher L2 and L2sj Liquid Level Controllers Emerson USwww.emerson.comFisher 2500 Pneumatic Level Controller Emerson USwww.emerson.com4150K and 4160K Series Wizard II Pressure Controllers and .gco-llc.comRecommended to you b

10 Micro Motion ProLink III. www.emerson.com. f) Select a storage location [CD-RW, DVD, USB Flash, or Floppy (real or image file)]. ProLink III writes a system transfer file to the storage device. g) Insert the storage device when requested. A success message pops up when the transfer is complete.File Size: 1MBPage Count: 48Explore furtherProLink III Configuration & Service Tool for Flow Meters .www.emerson.comMicro Motion ProLink III Configuration & Service Tool for .www.spartancontrols.comRosemount Radar Master - Software Emerson USwww.emerson.comRecommended to you based on what's popular Feedback

Based on the results obtained, it can be concluded that learning by using guided inquiry-based chemistry module is effective in improving students' character and concept understanding. Keywords: T. he effectiveness of learning ,Character Guided Inquiry Module Concept Understanding Classical Completeness Criteria . 1. Introduction . Chemistry is one of the subjects that is closely related to .