Brecknell PS150 Slimline And PS400 Slimline Digital .

2y ago
157 Views
3 Downloads
311.08 KB
9 Pages
Last View : 21d ago
Last Download : 3m ago
Upload by : Harley Spears
Transcription

Skip to contentManuals User Manuals Simplified.Home » Brecknell » Brecknell PS150 Slimline and PS400 Slimline Digital Receiving Scale InstructionsBrecknell PS150 Slimline and PS400 Slimline DigitalReceiving Scale InstructionsContents [ hide1 PS150 Slimline and PS400 Slimline1.1 Digital Receiving Scale1.2 User Instructions1.3 1 General Information andWarnings1.3.1 1.1 Specifications1.3.2 1.2 Description of Parts1.3.3 1.3 Installation1.3.4 1.4 Battery Installation1.3.5 1.5 Auto Shutoff Feature1.3.6 1.6 Mounting the Indicator1.3.7 1.7 Routine Maintenance1.3.8 1.8 Sharp Objects1.3.9 1.9 Cleaning the Indicator1.4 2 General Operation1.4.1 2.1 Display and Function1.4.2 2.2 Keypad1.4.3 2.3 Functions1.4.4 2.4 Calibrating the Scale1.5 File Downloads1.6 References1.7 Related ManualsPS150 Slimline and PS400 SlimlineDigital Receiving ScaleUser Instructions

AWT 35-100029Issue ABBrecknell is part of Avery Weigh-Tronix. Avery Weigh-Tronix is a trademark of the Illinois Tool Works groupof companies whose ultimate parent company is Illinois Tool Works Inc (“Illinois Tool Works”). Copyright 2020 Illinois Tool Works. All rights reserved.No part of this publication may be reproduced by making a facsimile copy, by the making of a copy in threedimensions of a two-dimensional work and the making of a copy in two dimensions of a three-dimensional work,stored in any medium by electronic means, or transmitted in any form or by any means, including electronic,mechanical, broadcasting, recording or otherwise without the prior written consent of the copyright owner, underlicense, or as permitted by law.All other trademarks, product names, brands, and/or company names are the property of their respective owners.This publication was correct at the time of going to print, however Avery Weigh-Tronix reserves the right to alterwithout notice the specification, design, price or conditions of supply of any product or service at any time.1 General Information and WarningsThe PS150 Slimline is a 150lb Digital Receiving Scale. The PS400 Slimline is a 400lb Digital Receiving Scale. Bothunits can be powered with (4) AA batteries or by using the provided power supply that plugs into the side of theindicator. The scale is equipped with a movable display that can be placed on the work surface or mounted to thewall.1.1 SpecificationsPS150 Slimline 150lb x 0.1lb / 70kg x 0.05kgCapacity (LB):PS400 Slimline 400lb x 0.2lb / 200kg x 0.1kgPS150 Slimline 68kg x 0.1kgCapacity (KG):PS400 Slimline 181kg x 0.2kgPower Source:4 AA batteries with automatic shutoffLCD Display1” digit size displays weight1.2 Description of Parts

41.3 Installation1. Remove the scale and indicator from the box.2. Connect the power supply to the side of the indicator or install batteries.Refer to section 1.4 for information on installing batteries.1.4 Battery InstallationThe Digital Receiving Scale operates with (4) “AA” batteries (Alkaline preferred). The battery compartment is locatedon the underside of the indicator portion of the scale.1. Turn the indicator over to expose the battery compartment.2. Remove battery compartment door and insert batteries into compartment.Make certain to observe the correct polarity.3. Replace compartment door.1.5 Auto Shutoff FeatureThis feature makes the scale shut off after 5 minutes of non-use to conserve battery life. You can disable this featureso the scale will operate continuously.1. With the scale off, press and hold the UNIT button.2. Press and hold ON, while holding the UNIT button down.3. The display will show “ 8888” and then “A of” will appear. The auto-off feature is now de-activated. Release thebuttons.4. To make the auto-off active again, repeat steps 1 and 2 and “ A on” will appear. The auto-off is now enabled.5

1.6 Mounting the Indicator1. Mount bracket to wall using (2) screws that are appropriate anchors for the surface being mounted to.2. Using the grooves in the rear of the indicator, slide indicator onto mounted bracket.1.7 Routine MaintenanceIMPORTANT: This equipment must be routinely checked for proper operation and calibration.Application and usage will determine the frequency of calibration required for safe operation.Always turn off the machine and isolate from the power supply before starting any routine maintenance to avoid thepossibility of electric shock.1.8 Sharp ObjectsDo not use sharp objects such as screwdrivers or long fingernails to operate the keys.1.9 Cleaning the IndicatorTable 1.1 Cleaning DOs and DON’Ts

DODO NOTAttempt to clean the inside of the indicatorWipe down the outside of standard products with aclean cloth, moistened with water and a small amountof mild detergentUse harsh abrasives, solvents, scouring cleaners oralkaline cleaning solutionsSpray the cloth when using a proprietary cleaning fluid Spray any liquid directly on to the display window672 General Operation2.1 Display and Function2.2 KeypadTare ButtonWhen pressed one time, the scale will tare (zero out) the load on the platform.Unit ButtonPress to change between the following units of measure: kg, lb, lb-oz.ON/OFF ButtonPress to turn the scale “ON” or “OFF”.By default, the scale turns off automatically after 5 minutes of inactivity.

82.3 Functions2.3.1 Power onTo turn the scale on, press the ON/OFF button. The display will turn on and automatically zero theweight. This indicates that the scale is ready for use.2.3.2 WeighingIf the scale does not show zeros, verify that nothing is on the scale and press TARE to zero thescale.1. When the display shows “0” it is ready to weigh an object.2. Place the item to be weighed on the scale base.The weight appears on the indicator.2.3.3 Tare OperationWhen weighing an item in a box or container, use the TARE function to zero out the weight of thecontainer.1. Place the box or container on the platform.2. Press TARE.The display will show “0”.3. Place the item to be weighed in the container.The weight on the display is the weight of the item and does not include the box or container.92.4 Calibrating the ScaleThe PS150/400 Slimline can be calibrated using either kilograms or pounds, depending on the unit of measure youwill be using the scale in.Before beginning the calibration procedure, be sure to have the necessary weights available.For calibration, the following weights are allowed:

Calibration in kilogramsCalibration in pounds10 kg20 lb20 kg50 lb30 kg100 lb75 kg150 lb100 kg200 lb150 kg300 lb200 kg400 lbValues in bold italics (above) are for the PS400 Slimline, only.1. With the scale on and the display showing zeros, press and hold the UNIT key until the maximum capacity of thescale is displayed. The display will also indicate which unit of measure (lb or kg).2. Press the UNIT key again to display the units of measure for calibration.

3. Press the TARE key to change the calibration unit of measure if necessary.104. Press the UNIT key to accept the calibration unit.The calibration span weight is displayed.5. Press TARE to change the calibration span weight. Available span weights are shown below.Calibration in kilogramsCalibration in pounds10 kg20 lb20 kg50 lb30 kg100 lb75 kg150 lb100 kg200 lb150 kg300 lb200 kg400 lbValues in bold italics (above) are for the PS400 Slimline, only.6. With the correct span weight displayed, press UNIT to accept.The display flashes.7. Place the calibration weight on the scale and press UNIT to accept.8. The display flashes showing either PASS or FAIL.

9. If FAIL is displayed, repeat the calibration process.11Brecknell USA1000 Armstrong Dr.Fairmont MN 56031Tel:507-238-8702Fax:507-238-8271Email: s.comBrecknell UKFoundry Lane,Smethwick, West Midlands,England B66 2LPTel: 44 (0) 8452 46 6717Fax: 44 (0) 8452 46 6718Email: les.comFile DownloadsInstructionsDownload [optimized]PS150 Slimline, PS400 Slimline, Digital Receiving Scale DownloadReferencesbrecknellscales.comco.ukRelated Manuals1. marantz Slimline Stereo Network Receiver Instructions NR1200 SLIM LINE STEREO NETWORK RECEIVER Indulgein high-resolution.2. Digital Luggage Scale User Manual Thank you for purchasing the Sharper Image Smallest Digital.3. ONYX Digital Kitchen Scale Manual 11lb x 0.1oz 5000g x 1g ONYX Manual Thank you.4. ACCURITE Digital Kitchen Scale Instruction Manual ACCURITE Digital Kitchen Scale Questions? Contact CustomerSupport at (877).5. Fiziom Professional Digital Scale User Manual Fiziom Professional Digital Scale User Manual Instructions Thank you for.6. Letsfit Digital Bathroom Scale EB5636H User Manual Digital Bathroom Scale EB5636H User Manual Note: Two 1.5VAAA.

Home » Brecknell » Brecknell PS150 Slimline and PS400 Slimline Digital Receiving Scale Instructions Brecknell PS150 Slimline and PS400 Slimline Digital Receiving Scale Instructions Contents [ hide 1 PS150 Slimline and PS400 Slimline 1.1 Digital Receiving Scale 1.2 User Instructions 1.3 1

Related Documents:

Founded in 1761, under Salter Brecknell, Brecknell has grown to become a global leader in weighing solutions. Brecknell products are designed and constructed with focus on high-value solutions and accuracy for easy operation for all your weighing applications. Today, Brecknell products can be found for most weighing applications.

Avery Weigh-Tronix Brecknell PS150, PS400 corresponds to the requirements of the following EC directives: EMC Directive 2004/108/EC The applicable harmonised standards are: EN61000-6-1:2007 EN61000-6-3:2007 A1:2011 ITW Ltd trading as Avery Weigh-Tronix Foundry Lane, Smethwick, West Midl

Avery Weigh-Tronix Brecknell PS150, PS400 corresponds to the requirements of the following EC directives: EMC Directive 2004/108/EC The applicable harmonised standards are: EN61000-6-1:2007 EN61000-6-3:2007 A1:2011 ITW Ltd trading as Avery Weigh-Tronix Foundry Lane, Smethwick, West Midl

167 NLN4211A Optional Deck (Tone PL) (Omni Extended, Slimline Extended) 169 NLN4961A Optional Deck (Selective Call) (Omni Extended, Slimline Extended) 92 0905677D03 Receptacle 93 0300139684 Screw (0-80 x 1 8 Fill Hd) 94 4105197G03 Contact 95 4605072E01 Block (Slimline Extended, Sli

Wicker: Madrid, Palma modular Slimline and beautiful! S-LINE represents the new slimline range of KETTLER’s latest generation of leisure furniture. Sleek, elegant and supremely comfortable – these are the characteristics that make a KETTLER garden chair so recognisable. The furniture labe

Part No. 62055 Slimline Model SL-3 Set-Up and Installation Guide IMPORTANT SAFETY INSTRUCTIONS a. Read these instructions. b. Keep these instructions. c. Follow all instructions. d. Do not use this apparatus near water. e. Clean only with dry cloth. f. Do not block any ventilation openings. Install in accordance with the manufacturer’s .

NOTE If replacing a Slimline assembly with a DISH assembly, remove the four bolts from the adaptor plate, and remove the adaptor plate. NOTE If replacing a Slimline assembly with a DISH assembly, align the small post on the back of the DISH 1000 adaptor plate with the small groove on the skew assembly hub. Fit the small post into the groove. Secure

erosion rate of unmasked channels machined in borosilicate glass using abrasive jet micro-machining (AJM). Single impact experiments were conducted to quantify the damage due to the individual alumina particles. Based on these observations, analytical model from the an literature was modified and used to predict the roughness and erosion rate. A numerical model was developed to simulate the .