INSTALLATION MANUALof an Underground Waterproofing SystemBased on PVC Membrane LOGICBASE V-SLKNOWLEDGE. EXPERIENCE. СRAFTSMANSHIP.www.technonicol.com

ForewordThis instruction manual was developed to improve the skills ofcontractors involved in waterproofing the PVC membranes forunderground structures.Objectives:—— describe waterproofing processes;—— provide visual aids for installing PVC membranes;—— improve the design quality and waterproofing constructionsfor underground structures, buildings and facilities;—— provide support for compliance with the requirements oftechnical regulationsMoscow City Business Centre,MoscowUnderground WaterproofingArea 32,600 m2LOGICBASE V–SL 2.0 mm2008–2012The tunnel of Federal Highway M27 Dzhubga–Sochi tothe border with Georgia on theAdler–Veseloye section, SochiWaterproofing of tunnelArea 8,500 m2LOGICBASE V–SL 2.0 mm20101Foreword

ContentsForeword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.1 General71.2 Designations and Scope71.3 Specifications of LOGICBASE V–SL Membranes81.4 Marking, Rules of Membrane Storage and Transportation 91.5 Description of a Waterproofing System Basedon the LOGICBASE V-SL PVC Membrane101.6 General Guidelines141.7 Safety142. Materials and Equipment. . . . . . . . . . . . . . . . . . . . . . . . .2.1 Main Materials for System Installation2.2 Auxiliary Materials for System Installation2.3 Equipment for Membrane Installation2.4 Tools and Devices17192325273. Hot-Air Welding of Membranes . . . . . . . . . . . . . . . . . .3.1 Seam Preparation3.2 Manual Welding3.3 Automatic Welding3.3.1 Selection of Welding Parameters3.3.2 Seam Forming2931323535384. Seam Quality Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.1 Visual Quality Inspection434.2 Instrumental Quality Control445. Waterproofing System Installation. . . . . . . . . . . . .5.1 Foundation Slab Waterproofing5.1.1 Base Preparation5.1.2 Geotextile Laying5.1.3 Installation of LOGICBASE V–SL WaterproofingMembrane5.1.4 Waterproofing Compartmentalization5.1.5 Installation of an Injection System5.1.6 Installation of Protective LayersContents249515152535557595.2 Installation of a Waterproofing Systemon a Diaphragm Wall5.2.1 Geotextile Laying5.2.2 Installation of LOGICBASE V–SL WaterproofingMembrane5.2.3 Installation of Protective Layers5.3 Vertical Installation of Waterproofingfor Excavation with Backfilling5.3.1 Compartmentalization of Waterproofingwith Profiled Waterstops5.3.2 Waterproofing Compartmentalizationwith an Adhesive Waterstop5.3.3 Installation of TechnoNICOL PVC Strips5.3.4 Installation of an Injection System5.3.5 Laying of Geotextile on Walls5.3.6 Installation of LOGICBASE V–SL WaterproofingMembrane5.3.7 Waterproofing Membrane Termination Options5.3.8 Waterproofing Protection616263666768697073747476796. Welding of Waterstops. . . . . . . . . . . . . . . . . . . . . . . . . .6.1 End Connections6.1.1 Welding with Special Equipment6.1.2 Welding with a Hot Air Hand Tool6.2. Angular and Cross-Shaped Elements6.2.1 Fabrication of Corner Elements6.2.2 Fabrication of Cross-Shaped Elements6.2.3 Fabrication of T-Shaped Elements6.2.4 Fabrication of a Right Angle6.2.5 A 90 Angle at the Point of Transition froma Horizontal Surface to a Vertical One838585868787888991967.Connection of Vertical and HorizontalWaterproofing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 977.1 Membrane Transition from the Foundation Slab to theRetaining Walls in Excavation Pits with Retaining Structures 997.2 Membrane Transition to Foundation Walls in anExcavation Pit with Backfilling1028. Corners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.1 An Inner Corner with a "Pocket"8.2 An Outer Corner8.3 Inner Corner in an Excavation with Backfilling1051071081119. Waterproofing of Expansion Joints. . . . . . . . . . . .9.1 Waterproofing of an Expansion Joint on a Foundation Slab9.2 An Alternative Method for Waterproofingof an Expansion Joint9.3 Waterproofing of an Expansion Joint on the Foundation Walls1151173118121Contents

110. Waterproofing of Utility Passageways. . . . . . . .10.1 Membrane Installation at Pipe Passageways10.2 Connection to a Pipe10.3 Connection to a Pipe with a Prefabricated Element11.125127127132Waterproofing of Piles. . . . . . . . . . . . . . . . . . . . . . . . . 13312. Well Waterproofing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13913. General Installation Requirements . . . . . . . . . . . . 1431.IntroductionContents45

111. Introduction1.1 GeneralRoki Road Tunnel, Republic ofNorth Ossetia–AlaniaTunnel WaterproofingArea 40,000 m2LOGICBASE V–SL 1.5 mm2015This instruction manual was developed to be used at constructionsites when waterproofing underground structures of buildings andfacilitiesThis manual includes recommendations from TechnoNICOL forinstalling LOGICBASE V-SL PVC membrane. It is based on membranelaying technology and only contains general rules for installing waterprooofing, so should be considered as a short reference book.TechnoNICOL LOGICBASE V-SL membranes are produced ona state-of-the-art AMUT line (Italy) from high-quality raw materials(PVC, plasticizer and specialized additives) using the extrusionmethod.LOGICBASE V-SL membranes fully meet a number of requirements for strength, fire safety and resistance to external impacts(chemical aggressiveness of groundwater, other types of aggression and impact of microorganisms) and durability, and emit notoxic substances during construction and use of facilities.The membranes have all the necessary certificates required bylaw confirming their high quality.1.2 Designations and ScopeDesignationLOGICBASE V-SL waterproofing PVC membranes are produced inrolls with a standard width of 2.05 m, length of 20 m and thicknessof 1.5 and 2.0 mm. Rolls may be custom-made with a length up to35 m and thickness of up to 3.0 mm.The designation of membranes includes:—— material name—— V-SL index—— thickness in millimeters—— number of the company standard for material productionAn example of marking of a 1.5 mm-thick LOGICBASE water proofing PVC membrane:Museum Complex of the StateTretyakov Gallery, MoscowBasement WaterproofingArea 10,000 m2LOGICBASE V–SL 2.0 mm2015LOGICBASE V–SL 1.5 mm STO 72746455-3.4.3-201512341 Material name2 The V-SL index partially describes the base and specifications: V — polyvinylchloride (PVC); S — signal; L — layer3 Material thickness in millimeters4 Regulatory document reference number for production of the material.Designations and Scope7introduction

11Field of applicationLOGICBASE V–SL Waterproofing PVC Membranes are used for:—— rotecting bearing and retaining structures that are in contactwith soil against the impact of ground and surface water, including water under pressure;—— waterproofing underground structures, underground parkinglots, basements and other underground parts of civil construction facilities;—— waterproofing underground pedestrian crossings;—— waterproofing subway stations;—— waterproofing road and railway tunnels constructed by anymethod, including the trenchless method;—— waterproofing underground tanks.1.3 Specifications of LOGICBASE V–SLMembranesLOGICBASE V–SL waterproofing PVC membrane is a homogeneous, watertight sheet folded into rolls.The membranes have high performance parameters essentialfor waterproofing of both small low-risk structures constructed insimple geological conditions and highly critical buildings and facilities in complex geological conditions.The use of LOGICBASE V–SL membranes for underground waterproofing is based on the following properties:—— absolute water-tightness at water pressure of up to 1.0 MPa;—— tensile strength over 16 MPa;—— ability to stretch by over 400 % without loss of water-tightness;—— resistance to rupture by a nail over 150 N;—— cold-bending at -35 С max;The material is classified as a thermoplastic polymer, membranesheets are easily welded with hot air, without using an open flame.Welded seams have a high tensile strength and are absolutelywatertight.Advantages of LOGICBASE V–SL Membranes—— High durability;—— High resistance to mechanical impact;—— High strength and flexibility;—— High elasticity at low temperatures;—— Possibility of use in aggressive or acidic environment;—— Resistance to root penetration;—— Microbiological stability;—— High chemical resistance;—— Possibility of laying on a damp underground structure;—— High speed installation;introduction8Specifications of LOGICBASEV–SL membranes—— Loose laying without gluing to the base, which allows easy compensation of movements and deformations of structures and soildue to the strength and elasticity of the membrane;—— Possibility of instrumental quality control of performed work;—— Easy quality control of complete waterproofing.1.4 Marking, Rules of Membrane Storageand TransportationLOGICBASE V–SL PVC membranes are supplied on wooden pallets; rolls are stockpiled on pallets in three rows with one roll shiftin each row.Rolls are additionally wound with a polyethylene film andbound on a pallet with a polymer strip with lining.Each roll is packed in a non-transparent polyethylene film forprotection against contamination and UV light.Each pallet with products has a properly marked packing list.The marking contains the following information:—— manufacturer’s name and address;—— trademark;—— product name;—— designation of the polymer membrane;—— number of the company standard;—— product issue date;—— type of upper and lower surfaces;—— color of upper and lower surfaces.The rolls shall be stored horizontally in one tier in height on palletsor without pallets, at least 1 m away from any heating appliances.Membranes at the construction site shall be protected againstan impact of direct sunlight, rain, snow, ice, etc. If stored in dry,clean and moderately cold conditions, preparation for welding isminimized.IMPORTANT! DO NOT store pallets with membrane on surfaces with a slope greater than 3%.Rolls of material shall be transported in covered vehicles andstacked horizontally on pallets in no more than two rows.Other means of transportation that ensure the integrity of thematerial are possible with the customer‘s approval.Material shall be loaded and transported in accordance withthe Cargo Transportation Rules applicable to the means of transport used.Marking, Rules of Membranes Storageand Transportation9introduction

11.5 description of a waterproofingsystem Based on the logicBase V-sl pVcmemBranetn-foundation prof diaphragm wall – reparablewaterproofing systemApart from waterproofing, TN-Foundation Prof Diaphragm Wallsystem includes a repair system that allows easy and quick elimination of leaks if they appear.In this system, a PVC membrane is loosely laid in one layeron the horizontal surface of the foundation slab and is attachedmechanically with PVC disk fixing elements or strips of PVC membrane on a vertical retaining wall.121231341456157168917101811191. soil2. excavation pit enclosure – diaphragm wall3. Leveling plaster4. PLanter geo drainage membrane5. technoniCoL needle-punchedgeotextile6. LoGiCBase V–sL waterproofingPVC membrane7. technoniCoL needle-punchedgeotextile8. Polyethylene film9. PVC disk fixing elementintroduCtion1PVC membranes shall be covered with geotextile before layingthem on concrete surfaces to prevent any possible damage.If the removal of water, coming through the retaining wall isrequired, a Planter Geo dimpled membrane should be placedbetween the diaphragm wall and the waterproofing system.The waterproofing is compartmentalized into isolated sectionsto monitor its integrity and to enable its repair.compartmentalization of waterproofingThe PVC membrane waterproofing system is loose-laid, i.e. it isnot attached to a base. In theevent of damage to the waterproofing, it can be compartmentalized into isolated sections toavoid water spreading alongthe entire structure. ProfiledPVC strips, waterstops, are usedfor compartmentalization.One of the waterstop surfaces has anchor elements along its entirelength. Waterstops are welded using hot air, with the smooth sidefacing towards the waterproofing membrane, thereby forming closedrectangular outlines. The maximum recommended size of one sectionis 150 m2. Waterstop anchors are embedded in concrete duringconcrete casting.Having such a system means that if waterproofing is damaged, water penetrating under the membrane does not spreadalong the whole structure, but is confined to a section bounded bywaterstops.The design includes a repair injection system to eliminatea leak in the TN-FOUNDATION–Diaphragm Wall waterproofingsystem.10. PVC injection flange11. technoniCoL eC-220-3 PVCwaterstop12. technoniCoL iC-240-2 PVCwaterstop13. niche for collection of injectionhoses14. a reinforced concrete structure15. Protective screed16. Concrete bed17. strengthening layer18. Compensator19. drainage pipe10desCriPtion oF a waterProoFinG systeMBased on the LoGiCBase V-sL PVC MeMBranedesCriPtion oF a waterProoFinG systeMBased on the LoGiCBase V-sL PVC MeMBrane11introduCtion

1121345The TN FOUNDATION Prof waterproofing system is used both foran excavation pit with a retaining structure where the diaphragmwall serves as an external formwork, and in the case of excavationwith backfilling.1234561. Diaphragm wall2. Geotextile with a density of 500 g/m23. LOGICBASE V–SL Membrane4. Injection flange5. Waterproofed section bounded by waterstops121310116914The Injection SystemThe injection system servesboth for monitoring ofthe waterproofing conditionand for its repair. The injectionsystem consists of injectionflanges and injection hosesconnected to them by fittings.Each standard section has5 injection flanges installed –4 in the corners and 1 in the center. When calculating the numberof injection flanges, use the following recommendation: 1 flangefor a maximum area of 30 m2, at least 2 flanges per 1 section.The flange is spot-welded to membrane. Injection hoses areconnected to flanges and routed through the reinforcement cageinside the structure directly or get collected in special injectionniches. Each hose is marked according to the section it relates to.If waterproofing is damaged and a leak appears, water normally starts coming through the injection hose, which allows preciselydefining the damaged section.After the damaged section is identified, special injection polymer compounds are pumped through the injection system in liquidform and fill the damaged section by filling the space between thewaterproofing membrane and the structure, and then are polymerized forming a dense watertight gel. In this way, water-tightness ofthe waterproofing system is restored.introduction12Description of a Waterproofing SystemBased on the LOGICBASE V-SL PVC Membrane157841. Soil2. PLANTER geo drainage membrane3. TechnoNICOL CARBON PROF 300extruded polystyrene4. TechnoNICOL needle-punchedgeotextile5. LOGICBASE V–SL waterproofingPVC membrane6. TechnoNICOL EC-220-3 PVCWaterstop7. Corner compensator made of extruded polystyrene TechnoNICOLCARBON PROF 300Description of a Waterproofing SystemBased on the LOGICBASE V-SL PVC Membrane58. Polyethylene film TechnoNICOL200 μm9. PVC injection flange10. TechnoNICOL IC-240-2 PVCWaterstop11. Protective sand-cement screed12. Niche for injection of the repaircompound13. Foundation slab14. Concrete bed15. Drainage pipe13introduction

111.6 General Guidelines—— Always follow the procedures specified in this guidebook;—— Carefully plan the procedure for installation of LOGICBASE V–SLwaterproofing membranes;—— Always consider the weather conditions at the construction site,both current and future;—— Clearly define the scope of work for the current day;—— It is desirable to have a completed section of waterproofing covered by protective layers by the end of a working day, includinggeotextile, polyethylene film and a protective screed. If a protective screed cannot be installed on the same day, it is preferableto leave the membrane unprotected, but fence off the completed work section and not admit any unauthorized persons toit. Before resuming the work, carefully check the unprotectedsection for any membrane damage;—— Seam quality control needs special attention;—— Before commencement of work, perform trial welding on site todetermine optimum welding modes for specific weather conditions;—— All seams made using automatic equipment with formation of adouble seam should be checked instrumentally using the overpressure method (see Section 4);—— Seams made with manual equipment should be spot checked bythe destructive method (see Section 4);—— Carefully check for possible mechanical damage of the laidmembrane (through punctures, cuts, ruptures).IMPORTANT! Preparation for WorkBefore starting waterproofing work, the LOGICBASE V-SLmembrane shall undergo incoming control that consistsin checking for compliance of the material’s quality with regulatory documents and the data sheet.1.7 SafetyDuring waterproofing work using polymer membranes, adhere tothe following requirements:—— Materials and equipment must be stored in areas designatedin the project execution plan.—— The following is prohibited during the work:use of faulty equipment and working without personal protection equipment;allowing unauthorized individuals to perform work;waterproofing works at wind speeds over 15 m/s, in case oficing, rain, snowfall or fog, affecting visibility in the work areaand at ambient air temperatures below –10 С or above 45 С.—— The waterproofing site must be provided with fire extinguishers,a sand box and fire-fighting equipment;introduction14Safety—— Waterproofing should be performed by trained personnel, whohave passed an exam for minimum technical requirements forwaterproofing, using PVC membranes and work safety;—— Welding must be performed by skilled workers with experienceof working with welding machines, including those manufacturedby Leister;—— Before commencement of work, the workers must be familiarized with the project execution plan and safety rules. Workmanagement and quality control must be performed by personswith experience in waterproofing of underground structures;—— Workers must be provided with work clothes, work shoes andpersonal protection equipment;—— Put on your goggles when using liquid detergents and compounds for seam surface preparation. These recommendationsmust be observed before welding of membranes and waterstopsas well as disc fixing elements;—— Welding equipment can be connected only to an earthed electrical outlet. An extension cable with protective ground may beused. When operating the equipment, use a circuit breaker withdifferential protection for safety;—— In order to ensure a continuous and stable welding process, it isrecommended to connect the welding machine to a separatenetwork or use a separate 220/380 V generator set;—— Do not change nozzles when the heating element is on, especially using tools (pliers). In case of incorrect clamping, this willcause nozzle deformation and, consequently, a poor qualityseam, even if work is performed correctly;—— Upon completion of the work and during replacement or cleaning of nozzles, keep the machine turned on for at least 5 minutes with the heating element deactivated in order to avoid itsoverheating;—— Do not operate electrical equipment if the power cable is damaged or reeled. Always completely unroll the reel before startingthe work.—— Upon completion of work with electrical equipment, disconnectthe power supply points from power sources and remove themto a closed room or cover with watertight material;—— Tools must be removed upon completion of ea

5.3.1 Compartmentalization of Waterproofing with Profiled Waterstops 68 5.3.2 Waterproofing Compartmentalization with an Adhesive Waterstop 69 5.3.3 Installation of TechnoNICOL PVC Strips 70 5.3.4 Installation of an Injection System 73 5.3.5 Laying of Geotextile on Walls 74 5.3.6 Installation of LOGICBASE V–SL Waterproofing Membrane 74

Related Documents:

WED 12 INDOOR MEETING - We welcome Chris Galvin to talk about 'AROUND THE WORLD IN 80 BIRDS'. Supported by Cameron Hughes, Chartered Accountants. SAT 22 COACH OUTING - RSPB BURTON MERE AND HOYLAKE Price: Adults 16.00, Juniors 8* SUN 30 BIRDWATCHING WALK - SENCE VALLEY AND KELHAM BRIDGE LRWT, LEICS

5.3. STAFInst Uninstall 6. Platform Installation Notes 6.1. Linux installation 6.2. AIX installation 6.3. HP-UX IA64 64-bit installation 6.4. IBM i 32-bit (previously known as i5/OS or OS/400) installation 6.5. z/OS installation 6.6. FreeBSD installation 6.7. Mac OS X installation 6.8. Solaris installation 7. Environment Variable Settings 7.1.

This installation manual is part of and shipped with the unit, and contains information on its safe installation. Read this installation manual completely before installing the unit. This installation manual must be kept available to installers at all times at the installation loca- tion. Keep this installation manual on hand throughout

Manual Part 3, Installation and Commission 1 VTA100004 Manual Part 4, Communication 1VTA100005 Motor Protection with ATEX Certification, Manual 1MRS755862 Operator’s Manual 1MRS755869 Protection Manual 1MRS755860 Technical Catalogue 1MRS755859 Technical Reference Modbus RTU 1MRS755868 Web Manual, Installation 1MRS755865 Web Manual, Operation .

10.0 system installation - roof insulation 10.1-10.4 - ssr work points 10.5-10.6 - panel installation 10.7-10.12 - alternate ice damming weatherseal 10.3 - ssr module strip installation 10.14-10.15 - endlap installation 10.16-10.18 - ridge installation 10.19-10.30 11.0 fascia conditions - eave fascia installation 11.1 - eave gutter installation .

Before installation, be sure to read this installation manual. Mount parts properly according to the directions. Avant l'installation, veuillez bien lire ce manuel d'installation. Montez correctement les pièces conformément aux instructions. Antes de realizar la instalación, asegúrese de leer este manual de instalación.

I9291 Remote Start/Keyless Entry Transmitter Installation I9292 Windshield Washer Solvent Heater Package Installation I9293 Multimedia Player Interface Module Package Installation I9294 Rearview Camera Package Installation I9295 Cellular Telephone Package Installation I9300 Roof Rack/Rail/Panel Installation

Each reference should include everything you need to identify the item. You need to identify the source type (e.g. book, journal article) and use the correct referencing format from this guide to create the reference. If you include items that are not specifically cited but are relevant to the text or of potential interest to the reader, then that is a bibliography. Generally speaking, the key .