N1091BSCA IEEE 802.3bs/cdMeasurement and Debug ApplicationCharacterize IEEE 50/100/200/400 Gb/s Electrical TX Designsusing N1000A/86100D DCA-X and N109X DCA-M OscilloscopesFind us at www.keysight.comPage 1Pag

Table of ContentsIntroduction. 3Transform Complexity into Simplicity . 4Select Industry-leading Hardware . 5Select the Desired Software Test Suite . 5Configure Your Measurements . 7Automated Return Loss Measurements . 8Guided Connection Diagrams for Easy Setup . 9More Features Streamline Development . 9Control Your Device or Other Equipment . 10Configure Your Solution in Three Ways . 11Oscilloscope Compatibility . 11Ordering Information . 17Required Software Options . 17Keysight Oscilloscopes . 17Find us at www.keysight.comPage 2Pag

IntroductionSeveral industry and standards bodies have adopted pulse amplitude modulation4-level (PAM4) technology to increase throughput within a given bandwidthcompared to Non-Return-to-Zero (NRZ) technology. As an example, PAM4technology is used in 50/100/200 Gb/s designs defined by IEEE 802.3cd, and in200/400 Gb/s designs defined in IEEE 802.3bs.The Keysight N1091BSCA IEEE 802.3bs/cd software is a measurementapplication for the DCA-X/DCA-M equivalent-time sampling oscilloscopesdesigned to save you time and money by automating the task of performingPAM4 and NRZ transmitter (TX) test measurements.Keysight N1091BSCAIEEE 802.3bs/cdsoftwareThe KeysightN1091BSCA IEEE802.3bs/cd software isa measurementapplication for theDCA-X/DCA-Mequivalent-timesampling oscilloscopesdesigned to save youtime and money byautomating the task ofperforming PAM4 andNRZ transmitter (TX)test measurementsFind us at www.keysight.comPage 3Pag

Transform Complexity into SimplicityThe N1091BSCA is an easy-to-use TX test application that: Saves time in understanding details of standards Reduces the time it takes to characterize your PAM4 and NRZ design fromhours to minutes Helps debug your device using custom configurations Allows you to quickly generate HTML reports that summarize theperformance of your deviceFind us at www.keysight.comPage 4Pag

Select Industry-leading HardwareConfigure your oscilloscope for single or multi-channel capability. The N1091BSCA application supports avariety of digital communication analyzer (DCA) oscilloscope configurations, including theN1000A/86100D DCA-X wide-bandwidth oscilloscope platform, and the N109X DCA-M family ofoscilloscopes. For return loss, the software controls an N1055A TDR module (or an economy orperformance network analyzer) and performs S-parameter measurements. For more hardwareconfiguration details, refer to the Ordering Guide in this document.Select the Desired Software Test SuiteThe N1091BSCA IEEE 802.3bs/cd TX test application covers PAM4 and NRZ transmitter measurementsoutlined in IEEE 802.3bs and IEEE 802.3cd specifications. The tests are sorted conveniently by clause.Click on the desired test group, and the appropriate tests are offered in Select Tests (factory-installedoptions shown).The N1091BSCA test application covers most TX tests outlined in the tables below. For acomprehensive and up-to-date list of specific tests covered by the application, download the N1091BSCAapplication from www.keysight.com, install it on a PC, and run the application in “Demo Mode”. Nolicense (or hardware) is required to run the software application in “Demo Mode”.Find us at www.keysight.comPage 5Pag

IEEE 802.3bs 200 Gb/s and 400 Gb/s OperationIEEE ReferenceDescription 1,2120B.3.1200GAUI-8 and 400GAUI-16 C2C transmitter characteristics120C.3.1200GAUI-8 and 400GAUI-16 C2M host output characteristics120C.3.2200GAUI-8 and 400GAUI-16 C2M module output characteristics120D.3.1200GAUI-4 and 400GAUI-8 C2C transmitter characteristics120E.3.1200GAUI-4 and 400GAUI-8 C2M host output characteristics120E.3.2200GAUI-4 and 400GAUI-8 C2M module output characteristicsIEEE 802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s OperationIEEE ReferenceDescription 1,2136.9.3Transmitter characteristics, 50GBASE-CR, 100GBASE-CR2, and 200GBASE-CR4137.9.2Transmitter characteristics, 50GBASE-KR, 100GBASE-KR2, and 200GBASE-KR4Annex 135B, 135B.3.1LAUI-2 C2C transmitter characteristicsAnnex 135C, 135C.3.1LAUI-2 C2M host output characteristicsAnnex 135C, 135C.3.2LAUI-2 C2M module output characteristicsAnnex 135D, 135D.3.150GAUI-2 C2C and 100GAUI-4 C2C transmitter characteristicsAnnex 135E, 135E.3.150GAUI-2 C2M and 100GAUI-4 C2M host output characteristicsAnnex 135E, 135E.3.250GAUI-2 C2M and 100GAUI-4 C2M module output characteristicsAnnex 135F, 135F.3.150GAUI-1 C2C and 100GAUI-2 C2C transmitter characteristicsAnnex 135G, 135G.3.250GAUI-1 C2M and 100GAUI-2 C2M module output characteristicsAnnex 135G, 135G.3.150GAUI-1 C2M and 100GAUI-2 C2M host output characteristicsFind us at www.keysight.comPage 6Pag

Configure Your MeasurementsCustomize parameters that are specific to your setup, such as signaling rate and CTLE setting. Usedefault values or enter your own settings including number of waveforms taken, type of pattern, andpattern symbol length. Choose Normal mode to test within limits or choose Debug mode to test to yourcustom limits and adjust other test parameters. Choose Your TestsThe N1091BSCA IEEE 802.3bs/cd TX test application provides comprehensive coverage of most PAM4and NRZ tests that are specific to the clause you are testing. You may click on all available tests, a groupof tests, or select individual tests to run. The full test name appears in the test list and is also shown in thetest results and reports. A description of the test and reference to the Standard is shown for each test.Find us at www.keysight.comPage 7Pag

Automated Return Loss MeasurementsWhen used in conjunction with an N1055A TDR module or vector network analyzer (ENA or PNA), theN1091BSCA IEEE802.3bs/cd compliance application performs differential and common mode return lossmeasurements.Find us at www.keysight.comPage 8Pag

Guided Connection Diagrams for Easy SetupSimply follow the steps to connect and configure your device under test and click Run Tests. TheN1091BSCA IEEE 802.3bs/cd TX test application automatically configures and controls your supportedDCA-X or DCA-M oscilloscope.More Features Streamline DevelopmentGenerate ReportsYour team members and your customers are interested in the performance of your device. Share a testresults report with them that shows the test conditions, summary of pass/fail, summary of all tests, anddetails for each test. Many include a test-specific screen shot of the measured parameter.Find us at www.keysight.comPage 9Pag

Control Your Device or Other EquipmentThe Automation tab enables you to enter commands to control external devices or equipment, and tofurther sequence your tests or to control timing.Find us at www.keysight.comPage 10Pag

Configure Your Solution in Three WaysThe hardware and software architecture provides wide flexibility. The N1091BSCA TX test applicationmay be run as follows:1. N1000A/86100D DCA-X runs the N1091BSCA application locally and controls remote ENA/PNA viaLAN2. PC runs the N1091BSCA application and controls remote N1000A/86100D DCA-X, ENA/PNA viaLAN3. PC runs both the N1091BSCA and N1010A FlexDCA software applications and controls remoteN1000A/86100D DCA-X and ENA/PNA via LAN, or a DCA-M via USB connection.This lets you use your PC for more processing power and other applications, or you can have allmeasurement capability consolidated into a compact solution. For return loss measurements, theN1091BSCA application can control an N1055A TDR or ENA/PNA vector network analyzer to performmeasurements automatically.Oscilloscope CompatibilityKeysight offers a wide range of electrical and optical test solutions to address current and emergingcommunications standards. For IEEE 802.3bs/cd testing, you may choose a hardware combination thataddresses your test needs for today, and into the future:1. N1000A/86100D DCA-X with N1060A/86108B (Integrated “One-Box” solution) - recommended2. N1000A/86100D DCA-X with DCA module and external clock recovery3. N109X Electrical DCA-M with external clock recoveryFind us at www.keysight.comPage 11Pag

Solution 1: Keysight N1000A DCA-X Mainframe N1060A “MegaModule” (Recommended) Highest accuracy Easy setup Integrated solutionMainframe Model No.Mainframe Hardware OptionsRequired: STR, PLK (N1000A), ETR(86100D)Required: N1010100A or 200, 201,9FP/9TP (for PAM4 analysis)Optional: LOJ/PTB (not used withN1060A/86108B)Optional: SIM (for de-embeddingcables)TX test using digital communications analyzer (DCA)N1000A DCA-X (or 86100D DCA-X)Plug-In Module Model No.N1060A (or 86108B)Mainframe Software Options(Fixed or Transportable Licenses)Plug-In Module Options232/050 (N1060A)232/HBW (86108B)Max # of Modules/Diff Channels1/1SoftwareN1091BSCAIEEE 802.3bs/cd Measurement and Debug ApplicationN1010AFlexDCA FW Rev 5.8 or later (included with N1000A/86100D mainframe)Keysight IO librariesRev 16.3 or later, automatically installed with FlexDCA installationAccessoriesN1060A86108B-PT2 or N1027A-PT2N1060A: No accessories are required (all modules include integrated de-skew)86108B: Phase trimmers (Qty 2), for modules with 2.4 mm connectors (86108B)N1060A-DC2, 86108B-DC2, N9399F, orN9399FDC blocks, 50 GHz (Qty 2)N1060A-CA2 or 86108B-CA2Matched cable set (Qty 1)Model No. (Pick TDR or PNA)DescriptionN1055A TDR/TDT35/50 GHz 2/4 Port TDR/TDT Remote Sampling Head for the N1000A/86100DDCA-X (any option) equipped with one of the following SW licenses: N1010200A,N1010300A or 202.Network analyzer (ENA/PNA)N5224A, N5244A or other 4-port PNA’s greater than 32 GHzN1930B PLTS SoftwaressFind us at www.keysight.comPage 12Pag

Solution 2: Keysight N1000A/86100D DCA-X Mainframe with DCA Module External ClockRecovery Highest flexibility Scalable solution High fidelity – remote heads minimize loss between DUT and oscilloscopeFind us at www.keysight.comPage 13Pag

Equipment Configuration for Solution 2:Keysight N1000A/86100D DCA-X Mainframe with DCA module External Clock RecoveryMainframe Model NoN1000A DCA-X (or86100D DCA-X)Mainframe Hardware OptionsRequired: PLK/LOJ/PTB (N1000A), ETR/PTB (86100D)Required: N1010100A or 200, 201,9FP/9TP (for PAM4 analysis)Optional: SIM (for de-embedding cables)Plug-In Module ModelNo (Pick ONE)TX test using digital communications analyzer (DCA)Mainframe Software Options(Fixed or Transportable Licenses)Plug-In Module OptionsMax # of Modules/Diff 5AAny4/8N1046A12F, 14F, 72F, 74F, 82F, 84F (any 2 or 4 channel config)4/8Clock Recovery ModelNo (Pick ONE)Clock Recovery Options (Pick 232/264SoftwareN1091BSCAIEEE 802.3bs/cd Measurement and Debug ApplicationN1010AFlexDCA FW Rev 5.8 or later (included with N1000A/86100D mainframe)Keysight IO librariesRev 16.3 or later, automatically installed with FlexDCA installationReturn LossMeasurementsAccessories*N1027A-76B (rec.)Clock Recovery Phase Matching Kit for use with N104XA remote head and N4877A/N107X CRN1027A-76AClock Recovery Phase Matching Kit for use with N104XA remote head and N4877A/N107X CRN1027A-MC1Clock Recovery Phase Matching Kit for use with N104XA remote head and N4877A CRN1027A-2P2Pick-Off Tees (Qty 2), for remote head modules with 1.85 mm/2.4 mm connectors (N1045A/B,N1046A, N1055A), (included in N1027A-76A/76B Kit)N1027A-PT2Phase trimmers, 50 GHz (Qty 2), for 861XX DCA modules with 2.4 mm connectors (86117A)N9399F or N9399FDC block, 50 GHz (Qty 2)Mode (TDR or PNA)DescriptionN1055A TDR/TDT35/50 GHz 2/4 Port TDR/TDT Remote Sampling Head for the N1000A/86100D DCA-X (any option)equipped with one of the following SW licenses: N1010200A, N1010300A or 202.Network analyzer(ENA/PNA)4-port ENA/PNA’s greater than 19 GHz (e.g. N5230C 140/145, N5224A, N5244A) N1930B PLTSsoftware* For more information on clock-to-data delay matching, refer to the Keysight N1076A/B, N1077A, and N1078A Clock Recovery DCA-M User Guide.Find us at www.keysight.comPage 14Pag

Solution 3: Keysight N109X Electrical DCA-M External Clock Recovery Flexible configuration Lowest cost ScalableFind us at www.keysight.comPage 15Pag

Equipment Configuration for Solution 3:Keysight N109X Electrical DCA-M External Clock RecoverySoftware Model No.(For User-Supplied PC)N1010A FlexDCASoftware Options(Install On PC, Or Purchase Fixed SW Licenses for the DCA-M)Required: N1010100A or 200, 201, 9FP/9TP (for PAM4 analysis)Optional: SIM (for de-embedding cables)Dca-M Model No.(Pick One)N1092CDca-M Options# Of Diff ChannelsRequired: LOJ, PLK1Optional: FS1N1092ERequired: LOJ, PLK1TX test using digital communications analyzer (DCA)Optional: FS1N1094ARequired: LOJ, PLK, 030 or 0501Optional: FS1N1094BRequired: LOJ, PLK, 030 or 0502Optional: FS1Clock Recovery Model No.(Pick ONE)Clock Recovery Options(Pick 232/264SoftwareN1091BSCAIEEE 802.3bs/cd Measurement and Debug ApplicationN1010AFlexDCA FW Rev 5.8 or later (included with N1000A/86100D mainframe)Keysight IO librariesRev 16.3 or later, automatically installed with FlexDCA installationReturn LossMeasurementsAccessories 1, 2N1027A-2P2Pick-Off Tees (Qty 2), for remote head modules with 1.85 mm/2.4 mm connectors(N1045A/B, N1046A, N1055A), (included in N1027A-76A/76B Kit)N9399F, N9399FDC block, 50 GHz (Qty 2)Model No. (Pick TDR or PNA)DescriptionN1055A TDR/TDT35/50 GHz 2/4 Port TDR/TDT Remote Sampling Head for the N1000A/86100D DCA-X(any option) equipped with one of the following SW licenses: N1010200A, N1010300A or202.Network analyzer (ENA/PNA)4-port ENA/PNA’s greater than 19 GHz (e.g. N5230C 140/145, N5224A, N5244A) N1930BPLTS softwareFind us at www.keysight.comPage 16Pag

Ordering InformationThe N1091BSCA IEEE 802.3bs/cd TX test application is available as a standalone license that isassigned by the user to a single DCA oscilloscope or PC (-1FP), or it may be ordered as a transportablelicense (-1TP) that can be moved by the user from one oscilloscope, or PC, to another.If a user has previously purchased an N1085A-1TP PAM4 “Pre-Compliance” SW Application, users maypurchase the N1091BSUA upgrade option. In this case, both N1085A-1TP and N1091BSUA-1TPlicenses must reside on the same instrument or PC.SW Model No.DescriptionFixed LicenseTransportable LicenseN1091BSCAElectrical TX Test AutomationSW for IEEE ires N1085A-1TP)Electrical TX Test AutomationSW for IEEE 802.3bs/cd,N1085A UpgradeN/AN1091BSUA-1TPRequired Software OptionsThe N1091BSCA software requires that N1010100A, or 86100D/N1010A-200/201/9FP (JitterAnalysis/Advanced Waveform Analysis/PAM4 Analysis), also be licensed on the platform.N1010100A SW license also allows users to perform optional features such as de-embedding ofcables/fixtures. Alternatively, users may also install 86100D/N1010A-SIM InfiniiSim WaveformTransformation Toolset licenses to enable de-embedding on an DCA-X/DCA-M platform. SeeOscilloscope compatibility section for more details.Keysight OscilloscopesMultiple form factors from 20 MHz to 110 GHz Industry leading specs Powerful applicationLearn more at: www.keysight.comFor more information on Keysight Technologies’ products, applications or services,please contact your local Keysight office. The complete list is available at:www.keysight.com/find/contactusFind us at www.keysight.comThis information is subject to change without notice. Keysight Technologies, 2018, Published in USA, July 09, 2019, 5992-3195ENPage 17Pag

Annex 135G, 135G.3.2 50GAUI-1 C2M and 100GAUI-2 C2M module output characteristics Annex 135G, 135G.3.1 50GAUI-1 C2M and 100GAUI-2 C2M host output characteristics . P a g e Find us at www.keysight.com Page 7 Configure Your Measurements Customize parameters that are specific to your setup, such as signaling rate and CTLE setting. .

Related Documents:

Standards IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1p for Class of Service IEEE 802.1Q for VLAN Tagging IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1X for authentication IEEE 802.3 for 10BaseT IEEE 802.3ab for 1000BaseT(X) IEEE 802.3ad for Port Trunk with LACP IEEE 802.3u for .

IEEE 802.1Q—Virtual LANs with port-based VLANs IEEE 802.1X—Port-based authentication VLAN Support IEEE 802.1W—Rapid spanning tree compatibility IEEE 802.3—10BASE-T IEEE 802.3u—100BASE-T IEEE 802.3ab—1000BASE-T IEEE 802.3ac—VLAN tagging IEEE 802.3ad—Link aggregation IEEE

Mobile Communication Technologies Local wireless networks WLAN 802.11 802.11a 802.11b 802.11i/e/ /w 802.11g WiFi 802.11h Personal wireless nw WPAN 802.15 802.15.4 802.15.1 802.15.2 Bluetooth 802.15.4a/b ZigBee 802.15.3 Wireless distribution networks WMAN 802.16 (Broadband Wireless Access) 802.20 (Mobile Bro

IEEE 3 Park Avenue New York, NY 10016-5997 USA 28 December 2012 IEEE Power and Energy Society IEEE Std 81 -2012 (Revision of IEEE Std 81-1983) Authorized licensed use limited to: Australian National University. Downloaded on July 27,2018 at 14:57:43 UTC from IEEE Xplore. Restrictions apply.File Size: 2MBPage Count: 86Explore furtherIEEE 81-2012 - IEEE Guide for Measuring Earth Resistivity .standards.ieee.org81-2012 - IEEE Guide for Measuring Earth Resistivity .ieeexplore.ieee.orgAn Overview Of The IEEE Standard 81 Fall-Of-Potential .www.agiusa.com(PDF) IEEE Std 80-2000 IEEE Guide for Safety in AC .www.academia.eduTesting and Evaluation of Grounding . - IEEE Web Hostingwww.ewh.ieee.orgRecommended to you b

IEEE 802.1d Spanning Tree Protocol (STP) IEEE 802.1s Rapid Spanning Tree (RSTP) IEEE 802.1w Multiple Spanning Tree (MSTP) IEEE 802.1q VLAN IEEE 802.1x Port-based Network Access Control IEEE 802.1p QoS Network Media 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m) 1000BASE-X: MMF, SMF Interface 8 10/100/1000Mbps RJ45 ports

DS-3E1526P-E Gigabit Web-Managed PoE Switch Key Feature 24 gigabit PoE ports, and 2 gigabit fiber optical ports. IEEE 802.3at/af standard for PoE ports. IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab, and IEEE 802.3z standard. 6 KV surge protection for PoE ports. AF/AT camera can reach up to 300 m in extend mode. PoE watchdog to auto detect and restart the .

CHAPTER 11-1 Enterprise Mobility 8.1 Design Guide 11 802.11r, 802.11k, 802.11v, 802.11w Fast Transition Roaming 802.11r Fast Transition Roaming The 802.11r Fast Transition (

3GPP2 EVDO EVDO Rev. A/B UMB WiMax WiMax 802.16d 802.16e WiMax 802.16m IEEE 2000 GSM&EDGE UMTS HSPA LTE (FDD/TDD) LTE-A 3GPP TD-SCDMA 2010 WiFi 802.11a/g WiFi 802.11ac/ad/af WiFi 802.11n WiFi 802.11b LTE-M 5G WiFi 802.11ax LAA, LWA 2020 802.11ah (IoT)