Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKCharacteristicsThe series of pilot operated servo proportional valvesD*1FP transfers the advantages of the Parker patentedVoice Coil Drive (VCD ) to larger frame sizes and thushigh flow rates. The high dynamics / high precision driveof the pilot valve allows the optimum control of the mainspool and results in servo class performance of thecomplete valves.The D*1FP series is available in 5 sizes:D31FP NG10 (CETOP 05)D41FP NG16 (CETOP 07)D81FP NG25 (CETOP 08) for port diam. up to 26 mmD91FP NG25 (CETOP 08) for port diam. up to 32 mmD111FP NG32 (CETOP 10)The safety concept works with a safe 4th position at theD1FP pilot valve. This ensures that the main stage ishydraulically balanced at power down and allows to havethe main spool spring centered (for overlapped spools)or approximately 10 % spring offset to spool position Aor B (for zerolap spools).The innovative integrated regenerative function into theA-line (optional) allows new energy saving circuits fordifferential cylinders. The hybrid version can be switchedbetween regenerative mode and standard mode at anytime.Features High dynamics High flow Defined spool positioning at power-down - optionalP-A/B-T or P-B/A-T or center position(for overlapped spools) Onboard electronics Energy saving A-regeneration Switchable hybrid versionA B0aGGbP TD41FP StandardA Ba03Standard D*1FPEGA BG0abGGbP TP TA-regeneration D*1FPRHybrid D*1FPZFurther literature about the opportunities of energysavings and more functional details of the integratedregeneration is available on request.D41FPE52 (Standard)ABGa0bGaP0bX YD 1FP UK.indd RH 22.03.20163-107Parker Hannifin CorporationHydraulics GroupT

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKRegenerative and Hybrid FunctionD*1FPR and D*1FPZARegenerative valve D*1FPRBGabG0a3bX YPHybrid valve D*1FPZTABGabGaPD*1FPR (regenerative valve)Cylinder extendingAAABQ PumpQ PumpQ RegenerationQ RegenerationTTCylinder extendingin standard mode (high force)BQ PumpbX YD*1FPZ (hybrid valve)Cylinder extendingin regenerative mode (high speed)B0PTTPPFlow rate in % of nominal flowSize 31/32/61PortA-TP-AP-BB-A (R-Valve)B-A (Hybrid)B-T (Hybrid)100 %100 %100 %50 %50 %50 %100 %100 %100 %50 %50 %50 %40 %50 %50 %20 %25 %20 %D31FP: For size NG10 please refer solution with sandwich- and adaptor plates "A10-1664 / A10-1665L / H10-1662 / H10-1666L" in chapter 12.D 1FP UK.indd RH 22.03.20163-108Parker Hannifin CorporationHydraulics Group

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKOrdering CodeDDirectional SizecontrolvalveCode3489 1)111FNG06pilotProportionalcontrolPVCD FunctionperformanceFlowSpoolPilot Seals Command Electronicposition connecsignaloptionson power tionsdownSizeNG10 / CETOP 05NG16 / CETOP 07NG25 / CETOP 08NG25 / CETOP 08NG32 / CETOP 100L 7)Regenerativefunction 4) 5)StandardCode Spool typeoverlapCodeCodeE01R31E02R32Spool typeoverlapSpool typeoverlapB32DEFHLBZ32QB QA /2E52CodeValve optionStandard forspool code B, E, RHybrid valve 24 Vnormally closed forspool code ZSignalFunction0. 10 V0. 10 VP - BQB QA /2zerolapzerolapB61(not requiredfor ordering)Z31CodeB31DesignseriesCode Electronic options6 PE acc.0EN175201-80411 PE acc.5EN175201-80476 PE enableHybridfunction 5) 6)CodeValveoptionzerolapR61E0. 20 mA0. 20 mAP - BK0. 10 V0. 10 VP - AS4.20 mA12.20 mAP - AZ61CodeNVHQB QA /2Flow [l/min]at Dp 5 bar per metering edgeD31D41D81D91 r HFC ernalexternalinternalinternalCode Spool pos. on power downPlease order connector separately. See chapter 3 accessories.Parametrizing cable OBE - RS232, item no. 409829231)2)3)4)5)For enlarged connections Ø 32 mm.Approx. 10 % opening, only zero lapped spools.For overlapped spools.Not for D81FP.For regenerative and hybrid function at D31FP (NG10) please refer to solutionswith sandwich and adaptor plates "A10-1664 / A10-1665L / H10-1662 / H101666L" in chapter 12.A BD31FP spooltype: R31T1 P T26)7)A B,R32A 2)B 2)A BR61T1 P T2C 3)T1 P T2Not for valve D31FP and D81FP.See page "Regenerative and hybrid function" (not for D31FP).D 1FP UK.indd RH 22.03.20163-109Parker Hannifin CorporationHydraulics Group3

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKTechnical DataGeneralDesignActuationSizeMounting InterfaceMounting positionAmbient temperatureMTTFD value 1)Weight3[ C][years][kg]Vibration resistance[g]HydraulicMax. operating pressure[bar]FluidFluid Nominal flow at Dp 5 bar per control edge 2)Max. recommended flow (standard)Regenerative B-A / B-TLeakage at 100 bar Overlapped spoolZerolapped spoolPilotOpening pointPilot supply pressurePilot flow during step response at 210 barStatic / DynamicStep response at 100 % stroke 3)Frequency responseAmplitude 5 % at 210 barPhase 5 % at 210 barHysteresisSensitivityTemperature drift of center positionElectricalDuty ratioProtection classSupply voltage / rippleCurrent consumption max.Pre-fusingInput signal Code K (B) VoltageImpedanceCode ECurrentImpedanceCode SCurrentImpedanceInput Capacitance typ.Differential input max.Enable signalDiagnostic signalEMCElectrical connectionWiring min.Wiring length max.1)2)3)Code 0Code 5Code 7Code 5/7Code 0/7Code 5Code 0/7Code 5[ [ml/min][ml/min][%][bar][l/min]Pilot operated servo proportional DC valveVCD -actuatorNG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10)D31D41D81 / D91D111DIN 24340 / ISO 4401 / CETOP RP121 / NFPAunrestricted-20. 507511.314.223.564.510 Sinus 5.2000 Hz acc. IEC 68-2-630 Random noise 20.2000 Hz acc. IEC 68-2-3615 Shock acc. IEC 68-2-27Internal pilot drain P, A, B, X 350; T, Y 35External pilot drain P, A, B, T, X 350; Y 35Hydraulic oil according to DIN 51524 . 535, other on request-20. 60 (NBR: -25. 60)20.40030.80ISO 4406 (1999); 18/16/13120200400 / 4502506001000depending on application, see flow curves2002006009009001000 500set to 10 command signal (see flow 10131945[Hz]128[Hz]118[%] 0.1[%] 0.05[%/K] 0.025959595904075[%] 100IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)[V] 22.30, ripple 5 % eff., surge free[A] 3.5[A] 4.0 A medium lag[V] 10.0.-10, ripple 0.01 % eff., surge free, 0. 10 V P– A (P– B)[kOhm] 100[mA] 20.0.-20, ripple 0.01 % eff., surge free, 0. 20 mA P– B[Ohm] 250[mA] 4.12.20, ripple 0.01 % eff., surge free, 12.20 mA P– A[Ohm] 250 3.6 mA enable off, 3.8 mA enable on acc. NAMUR NE43[nF] 1[V] 30 for terminal D and E against PE (terminal G)11 for terminal D and E against 0V (terminal B)[V] 30 for terminal 4 and 5 against PE (terminal W )11 for terminal 4 and 5 against 0V (terminal 2)[V] 30 for terminal D and E against PE (terminal G)[V] 5.30, Ri 8 kOhm[V] 10.0.-10 / 12.5 V (overload), rated max. 5 mAEN 61000-6-2, EN 61000-6-46 PE acc. EN 175201-80411 PE acc. EN 175201-804[mm²] 7 x 1.0 (AWG16) overall braid shield[mm²] 8 x 1.0 (AWG16) overall braid shield[m] 50If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability. px pNom.Measured with load (210 bar pressure drop/two control edges).Flow rate for different p per control edge: Qx QNom. ·D 1FP UK.indd RH 22.03.20163-110Parker Hannifin CorporationHydraulics Group

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKTechnical Data / ElectronicsElectrical characteristics hybrid optionDuty ratioProtection classSupply voltageTolerance supply voltageCurrent consumptionPower consumptionSolenoid connectionWiring min.Wiring length max.[V][%][A][W][mm²][m]100 %IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)D41D91D111242424 10 10 101.210.961.29292331Connector as per EN 175301-8033 x 1.5 recommended50 recommendedWith electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.WiringCode 0, 6 PE acc. EN 175201-804Code 5, 11 PE acc. EN 175201-804Code 7, 6 PE acc. EN 175201-804 enable1)Do not connect with supply voltage zero.D 1FP UK.indd RH 22.03.20163-111Parker Hannifin CorporationHydraulics Group3

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKInterface Program3ProPxD interface programThe ProPxD software allows quick and easy setting ofthe digital valve electronics. Individual parameters as wellas complete settings can be viewed, changed and savedvia the comfortable user interface. Parameter sets savedin the non-volatile memory can be loaded to other valvesof the same type or printed out for documentation purposes.The PC software can be downloaded free of charge atwww.parker.com/euro hcd – see page “Support" or directly at www.parker.com/propxd.Features Comfortable editing of valve parameters Saving and loading of customized parameter sets Executable with all Windows operating systems fromWindows XP upwards Simple communication between PC and valve electronics via serial interface RS232CThe valve electronics cannot be connected to a PC witha standard USB cable – this can result in damages of PCand/or valve electronics.The parametrizing cable may be ordered under itemno. 40982923.D 1FP UK.indd RH 22.03.20163-112Parker Hannifin CorporationHydraulics Group

Characteristic CurvesPilot Operated Servo Proportional DC ValveSeries D*1FPFrequency response 5 % / 25 % / 90 % command signalDynamics at 210 bar pilot supply pressureD31FPD41FPCatalogue HY11-3500/UK3D81/91FPD111FPFlow curves D*1FPB/E(Overlapped spool set to opening point 10 %)at Dp 5 bar per metering edgeD31FPspool type E01/02/52, B31/32/61D41FPspool type E01/02/52, B31/32/61All characteristic curves measured with HLP46 at 50 C.D 1FP UK.indd RH 22.03.20163-113Parker Hannifin CorporationHydraulics Group

Characteristic CurvesPilot Operated Servo Proportional DC ValveSeries D*1FPFlow curvesD81/91FPSpool type E01/02/52, B31/32/61D111FPSpool type E01/02/52, B31/32/61Flow curves D*1FPR/Z(Overlapped spool set to opening point 10 %)at Dp 5 bar per metering edgeD31FPSpool type R31/32/61D41FPSpool type R/Z 31/32/61Catalogue HY11-3500/UK3D91FP spool type R/Z 31/32/61D111FPspool type R/Z* on requestDetail:Standard, regenerative and hybrid flow curves001020Command signal [%]Flow Q[% of nominal flow]Zerolap spools:E52,B/R/Z61Overlap spools:E01,E02,B/R/Z31,B/R/Z32D 1FP UK.indd RH 22.03.20163-114Parker Hannifin CorporationHydraulics Group

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKPilot FlowPilot oil inlet (supply) and outlet (drain)open,closedPilot oilDrainInletinternalABGBCa0bexternalGexternal externalinternala0binternalexternal internalPD31FPB/Ex yCT3D31FPRD41FPB/EPBD41FPRD41FPZXTYXB 1/16"NPTFC M6 DIN906B 1/16"NPTFC 1/16"NPTFB 1/16 NPTFC 1/16"NPTF(drawn offset) P(drawn offset) TD91FPB/ED91FPRD91FPZD111FPB/ED111FPRD111FPZD 1FP UK.indd RH 22.03.20163-115Parker Hannifin CorporationHydraulics Group

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKDimensionsD31FP3Regenerative and hybrid function with additional plate "A10-1664 / A10-1665L / H10-1662 / H10-1666L", see chapter 12.Surface finishBK3854x M6x40ISO 4762-12.913.2 Nm 15 %NBR: SK-D31FPFPM: SK-D31FP-VBK3202x M6x554x M10x60ISO 4762-12.913.2 Nm 15 %63 Nm 15 %NBR: SK-D41FPFPM: SK-D41FP-VD41FPSurface finishD 1FP UK.indd RH 22.03.20163-116Parker Hannifin CorporationHydraulics Group

Pilot Operated Servo Proportional DC ValveSeries D*1FPCatalogue HY11-3500/UKDimensionsD81/91FP3Surface finishBK3606x M12x75ISO 4762-12.9108 Nm 15 %NBR: SK-D81/D91FPFPM: SK-D81/D91FP-VBK3866x M20x90ISO 4762-12.9517 Nm 15 %NBR: SK-D111FPFPM: SK-D111FP-VD111FPSurface finishD 1FP UK.indd RH 22.03.20163-117Parker Hannifin CorporationHydraulics Group

The series of pilot operated servo proportional valves D*1FP transfers the advantages of the Parker patented Voice Coil Drive (VCD ) to larger frame sizes and thus high flow rates. The high dynamics / high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.

Related Documents:

Pilot Operated Pressure Relief Valves Series R4V / R6V 4-21 R4V-R6V UK.indd 30.05.2018 4 Catalogue HY11-3500/UK Parer Hannifin Corporation . 9 R6V Y-port G 1/8" Code Vent valve 09 Solenoid not activ. unpress. circulation 11 Solenoid activated unpress. circulation Pilot oil Code Drain line 0 internal 1 1) external from subplate

Directional Control Valve Series D3W Catalogue HY11-3500/UK Parer Hannifin Corporation Hydraulics Group 2 Shift Limits / Response Times Measured with HLP46 at 50 C, 90 % U nom and warm solenoids. For even softer shifting, the proportional spools 081, 082, 101 and 102 can be used. Code Orifice size Energize De-energize

Maserati- 3500 GT Coupe Touring- Engine 9 Maserati- 3500 GT Coupe Touring- Exhaust 11 Maserati- 3500 GT Coupe Touring- Fuel System 12 Maserati- 3500 GT Coupe Touring- Glass and Seals 13 Maserati- 3500 GT Coupe Touring- Interior 18 Maserati- 3500 GT Coupe Touring- Lights 20 Maserati- 3500 GT Coupe Touring- Luggage Compartment 22

125 crf125f/fb je03e 3500 3500 3500 3500 3500 trx250tm/te te21e, te48e 3250 3250 3250 3250 150 CRF150F KE02E 4250 4250 4250 4250 400 TRX400X TE23E 3500 CRF150R*/ RB* KE03E 6250 6250 6250 6250 6250 420 TRX420FA/FPA TE37E 3250

Bently Nevada* Asset Condition Monitoring 3500/05 System Rack . Description . The 3500 System rack design holds all 3500 monitor modules and rack power supplies. It allows the various 3500 modules to communicate with one another and the power supplies to distribute power to each mod ule as required. 3500 Racks are available in two sizes: 1.

3500/61E & 3500/67E Temperature Monitor . Bently Nevada* Asset Condition Monitoring . 3300/35 6. with the I/O modules used for the 3300/36 2. Description . The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors can be ordered to accept Resis tance

Catalyst 3500 XL Cisco Cisco Catalyst 3500 XL 2900 XL Catalyst 1900 & &' IP 380 &' Gigabit Ethernet&' &' Catalyst 3500 XL&' Cisco IOS( Cisco Visual Switch Manager (CVSM) &' Web Cata-lyst 3500 XL&' * &' * 802.1Q ISL VLAN TACACS Uplink Fast Catalyst 3500 XL 3 Cisco GigaStack( Gigbit Interface Converter (GBIC)

pembelajaran sejarah melalui model active learning everyone is a teacher here kelas x sma kelas fitra abdi palembang tahun ajaran 2018/2019 skripsi oleh andini damarwulan 352014017 universitas muhammadiyah palembang fakultas keguruan dan ilmu pendidikan program pendidikan sejarah februari 2019 . ii upaya meningkatkan hasil belajar siswa dalam pembelajaran sejarah melalui model active learning .