Electronic Ballasts

2y ago
24 Views
2 Downloads
4.03 MB
84 Pages
Last View : 10d ago
Last Download : 3m ago
Upload by : Adele Mcdaniel
Transcription

Ballast Technology & Specification GuideSYLVANIA QUICKTRONIC Electronic BallastsSEE THE WORLD IN A NEW LIGHT

OSRAM SYLVANIA,the global leader in lighting systems, iscommitted to providing ballasts & lamps that aresolutionsthat exceed customerexpectations in meetinginnovativetoday’s lighting requirements.A global network ofdesign andmanufacturing brings ballast and lampknowledge together to produceinnovative, cost-effective systems.Complete Peace of MindQuick 60 WarrantyOnce registered, all SYLVANIAQUICKTRONIC ballasts areguaranteed for up to five years.When QUICKTRONIC ballasts arecombined with SYLVANIA lampsto form a SYLVANIA SYSTEMSOLUTION, the lamps are alsocovered under the same warrantyfor up to 36 months. This is theessence of QUICK 60 warranty,the first and most comprehensivesystem warranty in the industry.Exclusive FIXTURESIDE ASSISTANCE OptionThe benefits of the QUICK 60 system warranty can beextended even further. As needed, SYLVANIA LIGHTINGSERVICES, the only dedicated national lighting service company,will back up the warranty with field service calls to resolvewarranty claims. It’s OSRAM SYLVANIA’s version of “road-sideassistance” — we call it FIXTURESIDE ASSISTANCE .2

A focused network of marketing,engineering, and manufacturinggroups identify, design, andproduce some of the leadinginnovations in the market.Munich, GermanyLake Zurich, USADanvers, USAGlobal teams optimize synergieswhile the specific needs of eachlocal market are met.Traunreut, GermanyTreviso, ItalyTokyo, JapanPanyu, ChinaNew Delhi, IndiaCo-development of ballastsand lamps by engineers workingside-by-side ensures that eachsystem provides the best solution.Technology brought to lifePractical screen-based tasksby the Christian Bartenbach Group in Innsbruck/AustriaRecognition of words: correct responsesMAGNETICElectronic ballasts and their high frequency lamp operation havean extremely positive effect on the way we work.100ELECTRONIC11560708090100120Number of correct responses (%)Better PerformanceInput efficiency: text input mistakesMAGNETIC100ELECTRONIC6760708090The system solution has allowed technology to be developedthat greatly improves the quality of life in many ways.100120Recent ergonomic studies have shown that lamps operated athigh frequency reduce the eye stress caused by normal lampflicker, especially for people working with computers.Improvements incomfort, as well assignificant increases inthe quality of work inmany key areas, havebeen identified.Number of typing mistakes (%)Less fatigue and constant high performanceOverview of screen: reaction and processing timeMAGNETIC100ELECTRONIC7760708090100120Reaction and processing time (%)Much faster reaction and processing timeRecognition of details and differences: recognition on time (%)Much less time needed, greater efficiencyThe overallatmosphere ofthe workplace isgreatly enhancedcreating a moreproductiveenvironment.Many new lamps alsohave better colorproperties, longer life,and reduced mercurycontent to furtherimprove theworkplace. Add tothat the efficientoperation of electronic ballasts that use almost 50% lesspower and it’s clearly evident how the system solution helps tocombine ballast and lamp technologies to improve the quality of life.3OSRAM SYLVANIA National Customer Support Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.com

The system is the solutionOSRAM SYLVANIA’s unique approach to developingballasts and lamps has created some of the mostinnovative products in the market today. The abilityto combine the inherent knowledge of our lampengineers with the expertise of our electronicsengineers early in the development cycle hasfurthered the state of the art to new heights.GEN IV Innovative QUICKTRONIC GEN IV ballasts use the latest insurface mount electronictechnology, creating a smallerand lighter generation ofelectronic ballasts.The Original SystemSolutionThe first matched T8 lamp andballast systems for optimizedperformance and longer life.PLUS SystemsT8 lamps are run at higher lumenlevels to allow fewer lamps perfixture or higher light levels.QUICKSENSE The patented end-of-lamp-lifesensing technology that helpsprevent lamp overheating andestablished the benchmark forindustry recommendations.SYLVANIA XtremeSystemsQUICKTRONIC PROStart PSXUniversal Voltage ballasts withOCTRON FO32 XPS ECOLOGIC4-foot lamps. Up to 19% energysavings with comparable lightoutput and twice the lamp life ofstandard instant start T8 systems.HELIOS DIMMINGThe ultimate ballast withcontinuous 100- 5% dimmingrange (100-1% for T5HO). Theseballasts can be controlled by awide variety of 0-10 volt DCcontrol devices, including daylightsensors, building automationsystems and compatible wall boxdimming controllers.ICETRON SystemsUnique “Inductively CoupledElectrodeless Fluorescent LampSystems” that provide up to100,000 hour lamp life for use inhigh maintenance cost areas.HVIC MicroprocessorMULTIWATTNew electronic ballasts that offerthe versatility to operate multiplelamp types of various wattages.These models also can vary thenumber of lamps operated(ie 1 or 2 lamps), therefore newmulti-watt and multi-lampmodels reduce the amount ofballast types required.PENTRON HONew T5 high output fluorescentlamp systems provide almosttwice the lumen output of standardlamps and allow new low profilefixtures to be designed.PROStart A programmed starting methodfor fluorescent lamps thatachieves up to 100,000 switchingcycles which allows for increasedused on occupancy sensors.UNIVERSAL VOLTAGEUniversal voltage modelsoperate from 120 - 277 Volts,eliminating "incorrect linevoltage" wiring errors andreducing the number of modelsin inventory by half.High voltage integrated circuitsthat provide added controlfeatures and improve reliability.OSRAM SYLVANIA, the originator of thesystems approach, has led the industry froma collection of products supplied by differentcompanies, that were assumed to worktogether, to a systems approach that definesperformance, assures compatibility, anddelivers the assurance of quality that comesfrom focused, innovative marketing,engineering, and manufacturing efforts.4

Table of ContentsQUICKTRONIC ballasts for OCTRON T8 lampsT8 Instant Start 20%THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7T8 Instant Start 20%THD High BF (PLUS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9T8 Instant Start 20%THD Low BF (LP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11T8 Instant Start 20%THD Normal BF (connectors w/wo leads) . . . . . . . . . . . . . . . . . . . . . . .12T8 Instant Start 20%THD Low BF (connectors w/wo leads) . . . . . . . . . . . . . . . . . . . . . . . . .13Professional T8 Instant Start 10%THD Universal Voltage Normal BF . . . . . . . . . . . . . . . .14-15Professional T8 Instant Start 10%THD Normal BF (connectors w/wo leads) . . . . . . . . . . .16-17Professional T8 Instant Start 10%THD GEN IV Normal BF (Low Profile 0.88” high) . . . .18-19Professional T8 PROStart programmed rapid start 10%THD Normal BF . . . . . . . . . .20-21 R1Professional T8 Rapid Start 10%THD Normal BF (connectors w/wo leads) . . . . . . . . . . . 22 R1Professional T8 Rapid Start 10%THD Low BF (connectors w/wo leads) . . . . . . . . . . . . . 23 R1Professional T8 PROStart PSX 10%THD Universal Voltage Low BF. . . . . . . . . . . . . . . . .24-25Professional HELIOS T8 DIMMING (0-10 volt controllable) . . . . . . . . . . . . . . . . . . . . . . .26-27DIMMING 0-10 V HELIOS T8 and PHO wiring examples & controls list . . . . . . . . . . . . . . .28-29QUICKTRONIC ballasts for 8 foot lamps (T8/T12) & F40T12 SystemsInstant Start 96T8(59W) 20%THD and Professional 10%THD Normal BF . . . . . . . . . . .30-31Instant Start 96T8(59W) 20%THD High BF (PLUS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33Professional 96T8HO(86W) Rapid Start 10%THD Normal BF (connectors w/wo leads) . .34-35Instant Start 96T12 and 96T12HO Rapid Start 20%THD Normal BF . . . . . . . . . . . . . . . . . . .36Professional 40T12 Rapid Start 10%THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37QUICKTRONIC ballasts for T5/T4 lamps & Specialty SystemsProfessional T5 PROStart programmed rapid start 10%THD Normal BF . . . . . . . . . . . . .38-39TrademarksProfessional T5HO PROStart programmed rapid start 10%THD Normal BF . . . . . . . . . . .40-41Professional HELIOS T5HO DIMMING (0-10 volt controllable) . . . . . . . . . . . . . . . . . . . . . .42-43Instant Start DL40 (40WTT5) 20%THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44-45SYLVANIA, OCTRON, ICETRON,CURVALUME, METALARC,PENTRON, QUICKSENSE andQUICK 60 are registered trademarks of OSRAM SYLVANIA Inc.Professional PROStart DL40 (40WTT5) 10%THD Normal BF . . . . . . . . . . . . . . . . . . . . . .46-47Professional T4 Compact 10%THD Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . .48-49Professional T4 Compact 10%THD Dedicated Voltage . . . . . . . . . . . . . . . . . . . . . . . . . .50-51FM T2 Subminiature Compact 15%THD Universal Voltage . . . . . . . . . . . . . . . . . . . . . . .52-53ICETRON 15%THD Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54-55HELIOS, FIXTURESIDE ASSISTANCE, GEN IV, PROSTART andSEE THE WORLD IN A NEWLIGHT are trademarks of OSRAMSYLVANIA Inc.Professional MH Metal Halide 10%THD Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . .56-57QUICK INFORMATIONQUICKSYSTEMS (System Performance Guide) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58-65QUICKSAVINGS (Energy Savings Guide) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66-67QUICKTRONIC and DULUX areregistered trademarks of OSRAMGmbH under license.Information in this guide subjectto change at anytime withoutprior notice.QUICKLENGTH (Lead Lengths) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68-70QUICKSPEC (Sample System Specification) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71QUICKANSWERS (Reference Guide/Ballast Basics) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72-75QUICKCROSS (Manufacturer's Cross Reference) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76-79QUICKINDEX (Product descriptions) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80-81QUICK 60 (Warranty) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82-835OSRAM SYLVANIA National Customer Support Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.com

20% THD Electronic T8 Fluorescent SystemsQUICKTRONIC T8 Instant StartNormal Light OutputLamp/Ballast Guide32W T8 - OCTRON1-lamp QT1x32 IS-SC2-lamp QT2x32 IS-SC3-lamp QT3x32 IS4-lamp QT4x32 IS3-lamp QT3x32T8 ISN-SC4-lamp QT4x32T8 ISN-SCPrimary Lamp TypesFO32, FBO32, FBO31Also operates:FO17, FO25, FO40FBO16, FBO24F40T8 operation:1 lamp on 2L ballast2 lamps on 3L ballast3 lamps on 4L ballastKey System Features Standard enclosure size(3, 4-Lamp) New small enclosure size optionSYLVANIA QUICKTRONIC 32IS,32ISN-SC operates OCTRON T8lamps with maximum efficacyand high lumen output, andprovides 30-40% energy savingswhen compared to F40T12magnetic systems.New small can enclosure optionallows for low profile fixturedesign and application. New sizealso provides transportation,inventory and ergonomic benefits.Parallel circuitry is utilized tokeep the remaining lamps lit ifone or more should go out.Setting the standard for quality,SYSTEM 32IS, 32ISN-SC is alsocovered by our QUICK 60 warranty, the first and mostcomprehensive lamp & ballastsystem warranty in the industry. 89-90% Ballast factor 30-40% Energy savings 0 F StartingSystem InformationSYSTEM 32IS, 32ISN-SC isavailable in one through fourlamp models in 120V and 277V(and two lamp 347V) to cover awide range of applications.System Type2-lamp ISN-SC High power factor Low harmonic distortion Low in-rush current* Lightweight9686579557956067QUICKTRONIC 32IS, 32ISN-SCuses instant start operation toprovide the highest systemefficacy and to assure lowtemperature starting capability.Instant start also provides formaximum remote wiringdistances.F34T12 -Std. Magnetic BallastE.S. Magnetic Ballast8272475047505866F32T8/700 - Magnetic71532075F32T8/800 - R.S. Electronic62519084FO32/XP59540092QUICKTRONIC 32IS, 32ISN-SCelectronic ballasts have lowharmonic distortion with corresponding low in-rush current*for optimal system performance. UL, CSA, FCCApplication InformationSYLVANIAQUICKTRONIC 32ISN-SCis ideally suited for: Commercial Retail Hospitality Institutional Schools New Construction Retrofit Direct Lighting Indirect Lighting Surface Mount Cove Lighting6SystemLPWStd. Magnetic BallastE.S. Magnetic Ballast Virtually eliminates lamp flicker Quiet operationInitialLumensF40T12 - High luminous efficacy Compatible with mostpowerline carrier systems.*InputWattageQUICKTRONIC 32IS, 32ISN-SCelectronic circuitry is designedto be compatible with powerlinecarrier systems.*A complete OSRAM SYLVANIASystem Performance Guideshowing performance characteristics for all combinations oflamps and ballasts is availableupon request.* 1, 2 & 3 lamp models and4 lamp std enclosure- QT2x32IS-SCSystem Type4-lamp ISNInputWattageInitialLumensSystemLPWF40T12 - Std. Magnetic BallastE.S. Magnetic Ballast19217211590115906067F34T12 - Std. Magnetic BallastE.S. Magnetic Ballast164144950095005866F32T8/700 - Magnetic1421064075F32T8/800 - R.S. Electronic1221038085FO32/XP - QT4x32IS1141080095500 PC Pallet Packs – IS49555 QT3x32/120IS-PAL49556 QT3x32/277IS-PAL49228 QT3x32/347IS-PALWeight: 2.8 lbs each (approx)49557 QT4x32/120IS-PAL49558 QT4x32/277IS-PAL49229 QT4x32/347IS-PAL840 PC Pallet Packs – ISN-SC49951 QT1x32/120IS-SC-PAL49953 QT2x32/120IS-SC-PAL49955 QT3x32T8/120ISN-SC-PAL49957 QT4x32T8/120ISN-SC-PAL49242 QT2X32/347IS-SC-PALWeight: 1.6 lbs ea. (approx.)49952 QT1x32/277IS-SC-PAL49954 QT2x32/277IS-SC-PAL49956 QT3x32T8/277ISN-SC-PAL49958 QT4x32T8/277ISN-SC-PAL

T8 Instant StartNormal Ballast Factor 20% THD Electronic T8 Fluorescent o. .90540059922770.22FO32/XP300020.9054005992QT 3x32/120 IS1200.77FO32/XP300030.9081008793QT 3x32/277 IS2770.33FO32/XP300030.908100879349517QT 4x32/120 IS1200.98FO32/XP300040.90108001149549518QT 4x32/277 IS2770.43FO32/XP300040.90108001149549915QT 3x32T8/120 ISN-SC1200.74FO32/XP300030.898010879249916QT 3x32T8/277 ISN-SC2770.32FO32/XP300030.898010879249917QT 4x32T8/120 ISN-SC1200.96FO32/XP300040.89107001149449918QT 4x32T8/277 ISN-SC2770.42FO32/XP300040.89107001149449240QT 2x32/347 IS-SC3470.18FO32/XP300020.905400599249593QT 3x32/347 IS3470.26FO32/XP300030.908100879349594QT 4x32/347 iption49911QT 1x32/120 IS-SC12049912QT 1x32/277 IS-SC27749913QT 2x32/120 IS-SC49914QT 2x32/277 SystemLumensSystemEfficacy(lm/W)Performance GuideData shown based uponSYLVANIA OCTRON FO32/XPlamp(s). QUICKTRONIC 32ISand 32ISN-SC are alsocompatible with other lampmanufacturers equivalentlamp types that meet ANSIspecifications.All models will also operate F17,F25 and F32 (and the U-Bendequivalent) T8 lamps. Completeperformance data is available inthe QUICKSYSTEMS section ofthe SYLVANIA Electronic BallastCatalog.Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards.Rated lamp lumens and performance data based on OCTRON XP series cifications1BlueBlueRedLAMPLAMPLAMPNote: For one lamp application, cap any blue lead. Insulate to 600 volts.QUICKTRONIC 2x32QUICKTRONIC AMPLAMPNote: For two lamp application, cap any blue lead. Insulate to 600 volts.Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.QUICKTRONIC 3x32QUICKTRONIC 4x32Starting Method: Instant StartBallast Factor: 0.89-0.90Circuit Type: ParallelLamp Frequency: 20KHz3 & 4 lamp SC models: 40KHzLamp CCF: Less than 1.7Starting Temp.: 0 F min.1Input Frequency: 60 HzLow THD: 20%Power Factor: 97%Voltage Range: /-10% ofRated InputUL Listed Class P, Type 1 OutdoorCSA Certified70 C Max Case TemperatureFCC 47CFR Part 18 Non-ConsumerClass A Sound RatingANSI C62.41 Cat. A Transient ProtectionRemote Mounting up to 18 feet1Dimensions Standard Enclosure:Overall: 9.5” L x 2.38” W x 1.6” HMounting: 8.90"Dimensions "SC" Small Enclosure:Overall: 9.5" L x 1.68" W x 1.18" HMounting: 8.90"HeightWiring:WidthLeads only(no connectors provided)Item NumberMountingLengthLengthHeightPackaging:10 pieces49915 QT 3 x 32T8 / 120 ISN-SCQUICKTRONICNumber of Lamps (1, 2, 3, 4)OSRAM SYLVANIA National Customer Support Center1-800-LIGHTBULB thWidthCase SizeStarting/Ballast FactorLine VoltageOperation below 50 F may affect light output orlamp operation – see “Low Temp. Starting”definition.System Life / WarrantyQUICKTRONIC products are coveredby our QUICK 60 warranty, acomprehensive lamp and ballastsystem warranty. For additionaldetails, refer to our QUICK 60 warranty bulletin.Ordering GuideSpecifications subject to changewithout notice.Primary Lamp Wattage7

20% THD Electronic T8 Fluorescent SystemsQUICKTRONIC T8 Instant Start (PLUS)High Light OutputLamp/Ballast Guide32W T8 - OCTRON2-lamp QT2x32PLUS3-lamp QT3x32PLUSPrimary Lamp TypesFO32, FBO32, FBO31"A" can models (BF 1.13) alsooperate FO25, FO17, FBO24and FBO16 T8 lamps.Key System Features 120% Ballast factor* (118, 113%) 30% More light output thanstandard T8 systems 0 F StartingSYLVANIA QUICKTRONIC32 ISH (PLUS) operates OCTRON FO32, FBO32 and FBO31 T8lamps with increased lumen outputand high system efficacy.SYSTEM 32 ISH provides 20%more lumen output than F40T12magnetic systems while savingnearly 20% in energy. Comparedto standard T8 systems, 32PLUSprovides 30% more light output.High light output and multi-lampcapability for up to three lampsallows fewer ballasts to be usedin a fixture and provides tandemwiring options. Also, parallelcircuitry is utilized to keep theremaining lamps lit if one ormore should go out.Setting the standard for quality,SYSTEM 32 ISH is also coveredby our QUICK 60 warranty, thefirst and most comprehensivesystem warranty in the industry.SYSTEM 32 ISH is available intwo and three lamp models in120V and 277V (and two lamps347V) to cover a wide range ofapplications. Full lamp life High luminous efficacySystem Information Virtually eliminates lamp flicker Compatible with mostpowerline carrier systems Quiet operation High power factor Low harmonic distortion Low in-rush current Lightweight UL, CSA, FCCApplication InformationSYLVANIAQUICKTRONIC 32ISHis ideally suited for: Commercial Retail Hospitality InstitutionalF40T12SYSTEM 32 ISH uses instantstart operation to provide thehighest system efficacy and toassure low temperature startingcapability. Instant start alsoprovides for maximum remotewiring distances. Lamps areoperated at their rated current,but a higher frequency toprovide maximum light outputwhile ensuring rated lamp life.SYSTEM 32 ISH electronicballasts have low harmonicdistortion with correspondinglow in-rush current* for optimalsystem performance.SYSTEM 32 ISH electroniccircuitry is designed to becompatible with powerlinecarrier systems.* Schools New Construction Retrofit Direct Lighting Indirect LightingA complete OSRAM SYLVANIASystem Performance Guideshowing performance characteristics for all combinations oflamps and ballasts is availableupon request. Surface Mount Cove Lighting8System Type(2-lamp)* Except “A” can . Magnetic BallastE.S. Magnetic BallastE.S. Magnetic 720092FB40T12/D41 E.S. Mag. BallastF40T5ISElectronic Ballast8675579560006780FBO32/XP78696089QT2x32PLUS

T8 Instant StartHigh Ballast Factor 20% THD Electronic T8 Fluorescent PS)Lamp1Type49523QT 2x32/120 PLUS1200.6749524QT 2x32/277 PLUS27749525QT 3x32/120 PLUS4952649226ItemNumberRated2Lumens No. O32/XP300031.181060011295QT 3x32/277 PLUS2770.42FO32/XP300031.181060011295QT 2x32/347 PLUS3470.23FO32/XP300021.2072007892Ballast Factor: 1.131.1367807788Lighter WeightWiretrap connectors (with or without leads)50080QT 2x32T8/120 ISH-A1200.64FO32/XP30002InputSystemWattage Efficacy(W)(lm/W)Formerly: M2-IH-T8-GP-A-12050090QT 2x32T8/277 8Formerly: M2-IH-T8-GP-A-277New product check with OSRAM SYLVANIA for availability.New Small Can Enclosures49923 QT 2x32T8/120-ISH-SC49924 QT 2x32T8/277-ISH-SCBlackWhiteRedPerformance GuideData shown based uponSYLVANIA OCTRON FO32/XP lamp(s). QUICKTRONIC32PLUS is also compatible withother lamp manufacturers equivalent lamp types that meet ANSIspecifications.All models will also operateF32 (and the U-Bend equivalent) T8 lamps. Completeperformance data is availablein the QUICKSYSTEMSsection of the SYLVANIAElectronic Ballast Catalog.Specifications1LAMPStarting Method: Instant StartBallast Factor: 1.18-1.20(1.13 "A" can)Circuit Type: ParallelLamp Frequency: 20KHzLamp CCF: Less than 1.7Starting Temp.: 0 F minimum2Input Frequency: 60 HzLow THD: 20%Power Factor: 97%Voltage Range: /- 10% ofRated InputLAMPQUICKTRONIC 2x32 PNeutralLineLAMPLAMPRedBlueLAMPLAMPUL Listed Class P, Type 1, OutdoorCSA Certified70 C Max Case TemperatureFCC 47CFR Part 18 Non-ConsumerClass A Sound RatingANSI C62.41 Cat. A Transient ProtectionRemote Mounting up to 18 feet("A" enclosure remote up to 10 feet)QUICKTRONIC ISH-A 2 LAMPQUICKTRONIC 3x32 PLUSDimensions Standard Enclosure:Overall: 9.5" L x 2.38" W x 1.6" HMounting: 8.90"Dimensions "A" Enclosure:Overall: 9.5” L x 2.38” W x 1.5” HMounting: 8.91”LengthWiring:Leads only(no connectors provided)Data based on FO32/XP lamp. See the SYLVANIAQUICKTRONIC Electronic Ballast Technology andSpecification Guide (ECS-ELECTRONIC) for othersystem combinations.2Operation below 50 F may affect light output orlamp operation – see “Low Temp. y: 10 piecesWeight: 2.8 lbs ea. (approx.)MountingLengthLengthWidthMounting LengthPackaging:Quantity: 20 piecesWeight: 1.3 lbs ea. (approx.)Wiring/Packaging Configurations: All ISH-A products are available in the following packaging/wiring configurations:Item Code1Last Digit of Item Code01235008(#) QT 2ConfigurationDist. Pack, Leads Pre-InsertedDist. Pack, Connectors Only (No Leads)OEM Pack, Leads Pre-InsertedOEM Pack, Connectors Only (No Leads)x 32T8 / 120 ISH -A (suffix)Description SuffixNone (no suffix)NLOEMOEM NLQUICKTRONICEnclosure Type (A)Number of Lamps (2)Starting Type/Ballast FactorPrimary Lamp Type (FO32/XP)Line VoltageOSRAM SYLVANIA National Customer Support Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.comSystem Life / WarrantyQUICKTRONIC products are coveredby our QUICK 60 warranty, acomprehensive lamp and ballastsystem warranty. For additionaldetails, refer to our QUICK 60 warranty bulletin.Ordering GuideSpecifications subject to changewithout notice.9

20% THD Electronic T8 Low Power Fluorescent SystemsQUICKTRONIC T8 Instant Start (LP) Low PowerLamp/Ballast Guide32W T8 - so operates:FO17, FO25, FO40FBO16, FBO24SYLVANIA QUICKTRONIC32 ISL (LP) Instant Start LowBallast Factor Ballast operatesOCTRON T8 lamps at lowerpower levels for increased energysavings when reduced light isacceptable, and provides 35-45%energy savings when compared toF40T12 magnetic systems, and isperfectly suited to replace F34T12energy saving lamp systems.F40T8 operation:1 lamp on 2L ballast2 lamps on 3L ballast3 lamps on 4L ballastMulti-lamp capability for up tofour lamps allows fewer ballaststo be used in a fixture and provides tandem wiring options.Primary Lamp TypesFO32, FBO32, FBO31Key System Features 77% Ballast factor 30-40% Energy savings 0 F Starting High luminous efficacy Virtually eliminates lamp flicker Compatible with mostpowerline carrier systems Quiet operation High power factor Low harmonic distortion Low in-rush current LightweightParallel circuitry is utilized tokeep the remaining lamps lit ifone or more should go out.Setting the standard for quality,SYSTEM 32LP is also coveredby our QUICK 60 warranty, thefirst and most comprehensivesystem warranty in the industry.System InformationSYSTEM LP combined withOCTRON XP T8 lamps providesequivalent maintained light levels ofstandard IS ballasts and 700 seriesT8 lamps and saves more than 1per lamp per year in energy! UL, CSA, FCCApplication InformationSYLVANIAQUICKTRONIC 32 ISLis ideally suited for: Commercial Retail Hospitality Institutional SchoolsSYSTEM 32LP uses instant startoperation to provide the highestsystem efficacy and to assure lowtemperature starting capability.Instant start also provides for maximum remote wiring distances.SYSTEM 32LP electronic ballastshave low harmonic distortion withcorresponding low in-rush currentfor optimal system performance.SYSTEM 32LP electronic circuitryis designed to be compatible withpowerline carrier systems. New Construction Retrofit Direct Lighting Indirect Lighting Surface Mount Cove Lighting10A complete OSRAM SYLVANIASystem Performance Guide showing performance characteristicsfor all combinations of lamps andballasts is available upon request.SYSTEM 32LP is available intwo, three and four lamp modelsin 120V, 277V and 347V to covera wide range of applications.System 12 - Std. Magnetic BallastE.S. Magnetic Ballast19217211590115906067F34T12 - Std. Magnetic BallastE.S. Magnetic Ballast164144950095005866F32T8/700 - Electronic (88BF)112985088FO32/XP - QT4x32LP98924094

T8 Instant StartLP 20% THD Electronic T8 Low Power Fluorescent Current(AMPS)Lamp1TypeRated2Lumens(lm)Low Ballast FactorNo. )SystemEfficacy(lm/W)49533QT 2x32/120 LP1200.44FO32/XP300020.774620519149534QT 2x32/277 LP2770.19FO32/XP300020.774620519149535QT 3x32/120 LP1200.66FO32/XP300030.776930769149536QT 3x32/277 LP2770.29FO32/XP300030.776930769149537QT 4x32/120 LP1200.84FO32/XP300040.779240989449538QT 4x32/277 LP2770.37FO32/XP300040.779240989449241QT 2x32/347 LP-SC3470.15FO32/XP300020.774620519149225QT 4x32/347 LP3470.29FO32/XP300040.779240989412Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards.Rated lamp lumens and performance data based on OCTRON XP series lamps.Performance GuideData shown based uponSYLVANIA OCTRON FO32/XPlamp(s). QUICKTRONIC 32 ISLis also compatible with otherlamp manufacturers equivalentlamp types that meet ANSIspecifications.All models will also operate F17,F25 and F32 (and the U-Bendequivalent) T8 lamps. Completeperformance data is available inthe QUICKSYSTEMS section ofthe SYLVANIA Electronic BallastCatalog.New product check with OSRAM SYLVANIA for availability.New Small Can Enclosures49933 QT 2x32T8/120-ISL-SC49934 QT 2x32T8/277-ISL-SC49935 QT 3x32T8/120-ISL-SC49936 QT Note: For one lamp application, cap any blue lead. Insulate to 600 volts.BALLASTRedRedQUICKTRONIC 2x32 MPLAMPNote: For three lamp application, cap any unused blue lead. Insulate to 600 volts.QUICKTRONIC 4x32LAMPLAMPStarting Method: Instant StartBallast Factor: 0.77Circuit Type: ParallelLamp Frequency: 20KHzLamp CCF: Less than 1.7Starting Temp.: 0 F minimum2Input Frequency: 60 HzLow THD: 20%Power Factor: 97%Voltage Range: /–10% ofRated InputUL Listed Class P, Type 1 OutdoorCSA Certified where applicable70 C Max Case TemperatureFCC 47CFR Part 18 Non-ConsumerClass A Sound RatingANSI C62.41 Cat A. Transient ProtectionRemote Mounting up to 18 feet1Data based on FO32/XP lamp. See the SYLVANIAQUICKTRONIC Electronic Ballast Technology andSpecification Guide (ECS-ELECTRONIC) for othersystem combinations.2Operation below 50 F may affect light outputor lamp operation – see “Low Temp. Starting”definition.Note: For two lamp application, cap any blue lead. Insulate to 600 volts.QUICKTRONIC 3x32Dimensions Standard Enclosure:Overall: 9.5" L x 2.38" W x 1.6" HMounting: 8.90"Dimensions "SC" Small Enclosure:Overall: 9.5" L x 1.68" W x 1.18" HMounting: 8.90"System Life / WidthQuantity: 10 piecesWeight: 2.8 lbs ea. (approx.)Item NumberPackaging:MountingLengthLengthWidthQuantity: 10 piecesWeight: 1.6 lbs ea. (approx.)49533 QT 2 x 32 / 120 LPSystem Type – LPQUICKTRONICLine VoltageNumber of Lamps (2, 3, 4)Primary Lamp WattageOSRAM SYLVANIA National Customer Support Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.comQUICKTRONIC products are coveredby our QUICK 60 warranty, a comprehensive lamp and ballast systemwarranty. For additional details, referto our QUICK 60 warranty bulletin.Ordering GuideSpecifications subject to changewithout notice.11

20% THD Electronic T8 Fluorescent Ballast QUICKTRONIC T8 Instant StartInputVoltage(VAC)Lamp/Ballast GuideItemNumberSpecifications3Starting Method: Instant StartBallast Factor: 0.875Circuit Type: ParallelLamp Frequency: 20KHzLamp CCF: Less than 1.7Starting Temp.: 0 F min.3Input Frequ

F40T12 - Std. Magnetic Ballast 192 11590 60 E.S. Magnetic Ballast 172 11590 67 F34T12 - Std. Magnetic Ballast 164 9500 58 E.S. Magnetic Ballast 144 9500 66 F32T8/700 - Magnetic 142 10640 75 F32T8/800 - R.S. Electronic 122 10380 85 FO32/XP - QT4x32IS 114 10800 95 Weight: 2.8 lbs each (approx) 49555 QT3x32/120IS-PAL 49557 QT4x32/120IS-PAL

Related Documents:

Magnetic Ballast Warranty Info in back of this section 15" LEAD LENGTHS FOR STOCKED BALLASTS. CUSTOM LEAD LENGTHS AVAILABLE. CALL FOR DETAILS. INTER-GLOBAL - 1.800.325.7364 - WWW.INTERGLOBAL-INC.COM BALLAST BLACK BLACK WHITE LAMP STARTER LINE *Ballast Class P Non-stocked, Special Order, Call for details NOTE: All Ballasts Type 1, Outdoor

SECTION 16511 & 16521 - INTERIOR & EXTERIOR LIGHTING Ballasts (Electronic Compact Fluorescent) Advance Smart Mate Aculite Lightolier Lutron Prescolite Ballasts (Electronic Rapid Start T-8 Fluorescent) Advance Optanium Bodine (For emergency lighti

Jun 12, 2018 · EESB Parallel Wired Electronic Ballasts No. of Lamps Catalog Number Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage Wiring Diagram 1 18" 8' EESB-1808-1L 120V 0.85 100 800 1,7 1 to 3 4' 24' EESB-424-13L 120V 1.50 180 750 3,9 1 to 6 8' 32' EESB-832-16L 120V 2.40 282 800 4,10 1 to 4 10' 40

Jul 13, 2016 · EESB Parallel Wired Electronic Ballasts No. of Lamps Catalog Number Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage Wiring Diagram 1 18" 8' EESB-1808-1L 120V 0.85 100 800 1,7 1 to 3 4' 24' EESB-424-13L 120V 1.50 180 750 3,9 1 to 6 8' 32' EESB-832-16L 120V 2.40 282 800 4,10 1 to 4 10' 40

Jul 13, 2016 · EESB Parallel Wired Electronic Ballasts No. of Lamps Catalog Number Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage Wiring Diagram 1 18" 8' EESB-1808-1L 120V 0.85 100 800 1,7 1 to 3 4' 24' EESB-424-13L 120V 1.50 180 750 3,9 1 to 6 8' 32' EESB-832-16L 120V 2.40 282 800 4,10 1 to 4 10' 40

Advance Mark VII 0-10 V Electronic Dimming Ballasts Advance XitaniumR LED Drivers . For a current list of ballast models refer to the Lutron Ballasts Selection Guide. Driver / Ballast Functionality Check: With power OFF, . Check to see that purple and pink * wires are not cross connected in any fixture, conduit, or wallbox.

EESB-832-16L, & EESB-0250-16L (6-LAMP MAGNETIC TO ELECTRONIC) EESB- 424-13L (3-LAMP MAGNETIC TO ELECTRONIC) EESB Magnetic to Electronic Re-Wiring Diagrams For a live demonstration, watch our Magnetic to Electronic Replacement Video. Symbol ind

Type A Instant / Programmed Start Ballasts TCP’s DirecT8 tubes are the perfect replacement for old fluorescent lighting. Remove the existing T8 fluorescent and replace with DirecT8 Type A plug and play tubes. These tubes feature multiple ballast compatibility including Instant Start, Programmed Start, Rapid Start, and Dimmable ballasts.