Ultra-high-performance Fiber Reinforced Concrete: An .

3y ago
31 Views
2 Downloads
971.49 KB
12 Pages
Last View : 1d ago
Last Download : 3m ago
Upload by : Olive Grimm
Transcription

Computational Methods and Experiments in Materials Characterisation IV273Ultra-high-performance fiber reinforcedconcrete: an innovative solution forstrengthening old R/C structures and forimproving the FRP strengthening methodA. G. TsonosDepartment of Civil Engineering, Aristotle University of Thessaloniki,GreeceAbstractIn this study a new innovative method of earthquake-resistant strengthening ofreinforced concrete (R/C) structures is presented for the first time. Strengtheningaccording to this new method consists of the construction of steel fiberultra-high-strength concrete jackets without conventional reinforcement, whichis usually applied in the construction of conventional reinforced concrete jackets.An innovative solution is also proposed for the first time that ensures asatisfactory seismic performance of existing reinforced concrete structures,strengthened by using composite materials. The weak point of the use of suchmaterials in repairing and strengthening old R/C structures is the area ofbeam-column joints. According to the proposed solution, the joints can bestrengthened with a steel fiber ultra-high-strength concrete jacket, whilestrengthening of columns can be achieved by using CFRPs. The experimentalresults showed that the performance of the subassemblage strengthened with theproposed mixed solution was much better than that of the subassemblageretrofitted completely with CFRPs.Keywords: steel fiber ultra high-strength concrete, reinforced concrete jackets,fiber reinforced polymers, beam-column joints, columns, cyclic loads.1IntroductionDamage incurred by earthquakes over the years has indicated that manyreinforced concrete (R/C) buildings, designed and constructed during the 1960sWIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)doi:10.2495/MC090261

274 Computational Methods and Experiments in Materials Characterisation IVand 1970s, were found to have serious structural deficiencies today. Thesedeficiencies are mainly due to lack of capacity design approach and/or poordetailing of the reinforcement. As a result, lateral strength and ductility of thesestructures were minimal and hence some of them collapsed [1–3]. One of themost popular pre-and post-earthquake retrofitting methods for columns, beamcolumn joints and walls is the use of reinforced concrete jacketing. In retrofittingbuilding columns, b/c joints and walls with outer R/C jackets, the usual practiceconsists of first assembling the jacket reinforcement cages, arranging theformwork and then placing the concrete jacket [4–7]. Shotcrete can be used inlieu of conventional concrete in the repair works and, in some cases, offersadvantages over it, the choice being based on convenience and cost.The wrapping of reinforced concrete members (usually columns, b/c jointsand walls) with fiber-reinforced polymer (FRP) sheets including carbon (C),glass (G) or aramid (A) fibers, bonded together in a matrix made of epoxy,vinylester or polyester, has been used extensively through the world in numerousretrofit applications in reinforced concrete buildings. These are recognized asalternate strengthening systems to conventional methods such as plate bondingand shotcreting [8, 9].The best choice of the appropriate retrofitting method highly depends on thefeasibility of the method, on the cost and on the simplicity of the application. Ofcourse, it is well known that the works related to strengthening of buildings havehigher difficulties and cost compared to the usual construction works related tothe construction of new reinforced concrete buildings.According to the above conception it would be very interesting to create andintroduce in the marketing a new method of retrofitting old reinforced concretestructures, as effective as the other methods of retrofitting but simpler inapplication and more economical. An earthquake strengthening system with theaforementioned qualifications would be very competitive among the others.Henager [10], successfully replaced all the hoops of the joint region and partof the hoops of the critical regions of the adjacent beam and column of anearthquake-resistant beam-column subassemblage, by steel fibers (1.67% fibervolume fraction is used). This replacement involved 50% reduction in buildingcosts.Fiber Reinforced Concrete or Shotcrete has been successfully applied in manyconstruction applications eliminating or significantly reducing the conventionalreinforcement of R/C structures and reducing the construction costs.The advantages of Fiber Reinforced Concrete has been worldwiderecognized, however has not been found yet a reliable way of application of thismaterial in the retrofitting of old reinforced concrete structures, by eliminating orsignificantly reducing the conventional reinforcement of the R/C jacketings andgenerally by reducing the cost of retrofitting compared to that involved by theuse of other strengthening methods as plate bonding and FRPs. A relatively newprocess called SIMCON (Slurry Infiltrated Mat Concrete) developed byHackman et al. [11], seems to be very effective in strengthening applications.SIMCON is made by infiltrating continuous steel fiber-mats, with speciallydesigned cement-based slurry. Nevertheless, SIMCON technique has the sameWIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)

Computational Methods and Experiments in Materials Characterisation IV275disadvantages as FRPs. Their strengthening layers wrap usually horizontally thecolumns and the walls increasing their shear strength and ductility, but theselayers are terminating in the slabs of the strengthening reinforced concretebuildings. The strengthening layers could not effectively pass through the slabs,thus these layers could not increase the flexural strength of the columns andwalls and could not effectively retrofit the beam-column joint regions. Theexisting experimental results related to the retrofitting of beam-columnsubassemblages of reinforced concrete structures demonstrated significantdamage concentration in the joint regions, although the subassemblages usedwere of planar-type, without slabs and the retrofitting works related to SIMCONapplication were easy [12].2The proposed new innovative strengthening methodAn important experiment was conducted by Tsonos [13]. An exterior beamcolumn subassemblage L3 poorly detailed in the joint region was subjected tounidirectional reversed cyclic lateral loading. The joint region of thissubassemblage was representative of the joint regions of old structures builtduring the 1960s and 1970s. The subassemblage was reinforced in the jointregion by one hoop of diameter 8mm instead of the five hoops of the samediameter required by the ACI-ASCE Committee 352 (ACI 352R-02) [14]. Thejoint shear stress of the specimen was higher than the maximum allowable jointshear stress by the same Committee (τjoint 1.36 f c τpermitted 1.0 f c ). Asexpected, this specimen failed in pure and premature joint shear failure from theearly stages of the seismic-type loading. The removal and replacement of thedamaged concrete in the joint by a non-shrink, non-segregating steel fiberconcrete of high-strength with only 0.5% fiber volume fraction and the removaland replacement of the damaged concrete cover of part of the columns’ criticalregions with the same steel fiber high-strength concrete, resulted in a pure beamfailure, when the repaired subassemblage RL3 was imposed to the same loadingas the original control subassemblage L3.The above experiment led us to the idea of using the same non-shrink, nonsegregating steel fiber high-strength concrete for the strengthening of oldreinforced concrete buildings, by jacketing not with the use of conventionalreinforcement, longitudinal bars or hoops [15]. For this purpose and for bestresults, it was decided to increase the fiber volume fraction and to increase thecompressive and tensile strengths of the steel fiber concrete. The following largeexperimental program was implemented. Four identical exterior beam-columnsubassemblages were constructed, using normal weight concrete and deformedreinforcement. The test specimens were 1:2 scale models of the representative40cm 40cm square columns and beam-column joints which are usually found inbuilding constructions within Greece and Europe in general. The columns andb/c joints of these specimens were poorly detailed in order to represent columnsand b/c joints of old buildings built in 1960s and 1970s. In figure 1 are shown thedimensions and cross-sectional details of these specimens. Their columns hadWIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)

276 Computational Methods and Experiments in Materials Characterisation IVless longitudinal and transverse reinforcement than the modern columns andtheir joint regions had not joint hoops, the joint shear stress were 2.20 f c MPa 1.0 f c MPa, and the flexural strength ratios of these specimens were lowerthan 1.0. The concrete compressive strength of these original specimens wasapproximately 8.50MPa. Thus, a premature joint shear failure is expected for allthese subassemblages during a seismic type loading. All these original specimenswere subjected to cyclic lateral load histories so as to provide the equivalent ofsevere earthquake damage. In figure 2 is shown the failure mode of therepresentative specimen O3 and its hysteresis loops. The failure of O3 wasconcentrated mainly in the joint which lost almost all of the core’s concrete.In the following are described in brief the retrofitting works for specimens O3,W2, M1, and M3.N Vb0.95H4 6 6/152 14 8/20VbB0.301.402 144 6HB3 80.60Figure 1: 14SECTION Α-Α2 14 8/7cm 6/15cmN0.20SECTION B-BVb0.30 8/7AA0.20 6/15Load points0.20 142 140.20Dimensions and cross-sectional details of original subassemblagesO3, W2, W3, M1, and M3.Specimen O3120Applied shear Vb (kΝ)804010-402 3984 5 6 7 897 6 54 3 21-80-120-7 -6 -5 -4 -3 -2 -1 0 1 2Drift angle R (%)Figure 2:34567Plots of applied shear versus drift angle and failure mode of theoriginal subassemblage O3.WIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)

Computational Methods and Experiments in Materials Characterisation IV1.277Specimen O3 was retrofitted by reinforced concrete jacket in the columnsand beam-column joint region. The compressive strength of the jacket’sconcrete was 31.70MPa. Deformed bars were used for the construction ofthe steel cage of the jacket. After the interventions this specimen wasdesignated SO3. In figure 3 is shown the jacketing of column and beamcolumn connection of subassemblage SO3.2. Specimen W2 was strengthened by a high-strength fiber jacketing in the jointregion and on the columns (see figure 3). The damaged concrete of the jointregion of specimen W2 was removed and replaced by a premixed, nonshrink, rheoplastic, flowable and non-segregating concrete of high-strength.The repaired and subsequently strengthened specimen was named FW2. Thedesign for the retrofit process with carbon fiber-reinforced polymer sheets(CFRPs) was based on Ef 235GPa, tf 0.11mm (tf layer thickness) andεfu 1.5% (εfu ultimate FRP strain).3. Subassemblage M1 was strengthened by jacketing with ultra high-strengthsteel fiber-reinforced concrete (UHSFC) with 1.5% fiber volume fraction inthe columns and in the joint region. The thickness of the jacket was only4.0cm. The repaired and subsequently retrofitted specimen was namedHSFM1 (see figure 3).4. Subassemblage M3 was retrofitted by jacketing with UHSFC with 1.0%fiber volume fraction, in the columns and in the joint region. The thicknessof the jacket was 6.0cm. The repaired and strengthened specimen wasnamed HSFM3 (see figure 3).The compressive strengths of the UHSFC used for the strengthening ofHSFM1 and HSFM3 were 106.33MPa and 102.30MPa respectively. The tensilestrength of the UHSFC used, was approximately equal to 12MPa. The steelfibers used were Dramix ZP 30/0.6.All the above strengthened subassemblage SO3, FW2, HSFM1 and HSFM3were imposed to the same loading as that of their original subassemblages. Allstrengthened specimens demonstrated increased strength, stiffness and energydissipation capacity as compared to those of their original specimens (comparehysteresis loops between the original and the upgraded subassemblages infigures 2 and 4 e.g. O3 – HSFM1). However, the failure mode of SO3 and FW2was quite different from that of all upgraded specimens by the new proposedjackets HSFM1 and HSFM3. Thus although, the beams of both SO3 and FW2yielded, the majority of the damage was concentrated in their joint regions, seefailure modes of specimens in figure 4. On the contrary, the failure mode of bothspecimens HSFM1 and HSFM3 was the optimum one. Formation of plastic hingein their beams was observed from the first cycles of loading, while the followingcycles resulted in damage concentration only in the critical regions of theirbeams near their joints. A mixed flexural – shear failure mode was observed intheir beams at the end of the tests, which was accompanied by severe buckling ofthe longitudinal beam reinforcement. The joints and the columns of both thesespecimens were intact at the conclusion of the tests. This excellent seismicperformance of both the HSFM1 and HSFM3 subassemblages was demonstratedboth in their failure modes (figure 4) and in their hysteresis loops (figure 4).WIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)

278 Computational Methods and Experiments in Materials Characterisation IVDetail (1)AddedreinforcementDetail (2)Existing columnreinforcementWeldsSteel flat bar5 2 cmf y 315 MPaCollar stirrup10 cm 14 f y 500 MPaBar segment of 14N Vb0.95HWeldsSECTION B-BAdded reinforcement0.32Reinforced concretejacketBVbBDetail (1)A 8/7cm 14VbA0.20SECTION Α-ΑAdded reinforcement 2 140.06ExistingcolumnreinforcementExisting column0.20HLoad points0.300.301.40Added steel collarstirrups 14NAdded ties 8/7cm0.060.20Reinforced concretejacket0.060.200.06Added reinforcement2 14Specimen SO3N Vb0.95HSECTION B-B3423 cmanchoragelength510 cm4B6 1415 cm anchorage length3N0.201 , 25VbSECTION Α-Α4H 8/7cm4AALoad points 14B0.202 14 6/15cm0.2050.301.40110 cm5Vb0.30230.202 1441 2 layers of CFRPs for increasing the horizontal shear strength of the joint2 5 layers of CFRPs at the front side and 5 layers at the back side forincreasing the vertical shear strength of the joint3 5 layers of CFRPs for increasing the flexural strength of columns4 2 layers of CFRPs for increasing the shear strength of columns5 4 layers of CFRPs, 100mm in width, to prevent premature debondingof column strengthening layers6 4 layers of CFRPs, 100mm in width, to secure the anchorage lengthof the joint layersSpecimen FW2Figure 3:Jacketing of column and beam-column connectionsubassemblages SO3, FW2, HSFM1, and HSFM3.WIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)of

Computational Methods and Experiments in Materials Characterisation IVN Vb0.95H4 6 6/15 8/202 14VbB0.301.402 82 8 6/15 8/7A4 6SECTION B-B3 8Vb 6/15cm0.040.20 142 140.20HN0.28SECTION Α-Α0.04AB0.60Load points0.04Jacket by steel fiberultra high strength concretewith 1.5% fiber volume fraction0.200.040.302 14 8/7cm2 14 140.20ExistingcolumnSpecimen HSFM1N Vb0.95H4 6 6/15 8/202 14VbB0.302 82 8 8/7AAB4 60.32 142 140.20 6/15cm0.060.20SECTION B-BVbSECTION Α-ΑHN3 80.60Load points0.06Jacket by steel fiberultra high strength concretewith 1.0% fiber volume fraction0.200.06 8/7cm2 14 14ExistingcolumnSpecimen HSFM3Figure 3:0.30 6/150.061.402 14Continued.WIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)0.20279

280 Computational Methods and Experiments in Materials Characterisation IVSpecimen SO3120Applied shear Vb (kΝ)802 3 5 6471400891111-4010-80101976 5 483 2-120-7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7Drift angle R (%)Specimen FW2120Applied shear Vb (kΝ)8012 3 5464087910011-4010 9118 76 5-8043 21-120-7 -6 -5 -4 -3 -2 -1 0 1 2 3Drift angle R (%)567Specimen HSFM112080Applied shear Vb (kΝ)43 4562140780-40-80817 6 54 3 2-120-7 -6 -5 -4 -3 -2 -1 0 1 2Drift angle R (%)34567Specimen HSFM3Applied shear Vb (kΝ)120802 4365140707-401-806 5 4 3 2-120-7 -6 -5 -4 -3 -2 -1 01234567Drift angle R (%)Figure 4:Plots of applied shear versus drift angle and failure mode of thestrengthened subassemblages SO3, FW2, HSFM1 and HSFM3.WIT Transactions on Engineering Sciences, Vol 64, 2009 WIT Presswww.witpress.com, ISSN 1743-3533 (on-line)

Computational Methods and Experiments in Materials Characterisation IV281The seismic behavior of both these subassemblages was superior to those ofspecimens SO3 and FW2 retrofitted by reinforced concrete jackets and FRP-jackets.A patent No 1005657 was awarded to Professor Tsonos [16] by the GreekIndustrial Property Organization for the above invention.3An innovative new solution for improving the FRPstrengthening methodAn innovative solution is proposed also for the first time. This solution ensures asatisfactory and perhaps perfect seismic performance of existing old reinforcedconcrete buildings strengthened by using composite materials FRPs. The weakpoint in using such materials in repairing and strengthening reinforced concretestructures is the area of beam-column joints. Indeed, all the strengthenedsubassemblages in the beam-column region with composite materials FRPs ofthe literature demonstrated in the best case a mixed type failure during seismictype loading. Thus, during the first cycles of loading their beams yielded,however during the following cycles a large part of damage of these strengthenedsubassemblages was concentrated in their joint regions. Of course, this failuremode is highly dangerous for the people who live in old buildings which wereretrofitted in post-earthquake or pre-earthquake cases. The representative failuremode of subassemblage FW2 clearly demonstrates this critical situation, figure 4.The whole strengthened beam-column joint region of FW2 not only failed butalso was removed (i.e. leaving a hole in this position) during the last cycles ofloading. This exactly is the reason why the Greek Code of the Repair andStrengthening of Reinforced Concrete Buildings [17] does not allow the use ofcomposite materials for the strengthening of reinforced concrete beam-columnjoints.The second innovative solution presented in this study consists ofstrengthening the joint regions of subassemblages with a local jacket of ultrahigh-strength steel fiber concrete with 1.5% fiber volume fraction, whileretrofitting the columns can be achieved by using composite materials FRPs. Inorder to investigate the effectiveness of the proposed solution of mixed typestrengthening a new beam-column subassemblage W3 identical with the otherfour (O3, W2, M1 and M3, figure 1), was constructed and was imposed to seismictype loading as the other original subassemblages. The failure mode of W3 wasthe same as that of O3 previously described. The subassemblage was retrofittedby the new mixed type technique shown in figure 5. After the interventions thisspecimen was designated FHSFW3. The columns of FHSFW3 and FW2 wereretrofitted exactly in the same way with composite materials CFRPs, while thejoint region was retrofitted with ultra high-strength steel fiber concrete with1.5% fiber volume fraction. Specimen FHSFW3 was imposed to the same typeloading as that of the original specimen W3. The seismic performance ofFHSFW3 was optimal. The damage was concentrated only in the critical regionof the beam, while the columns and the joint region were intact at the conclusionof the tests. This optimal performance was demonstrated also in the hysteresisloops of the subassemblage FHSFW3. The hysteresis loops of

Ultra-high-performance fiber reinforced concrete: an innovative solution for strengthening old R/C structures and for improving the FRP strengthening method A. G. Tsonos Department of Civil Engineering, Aristotle University of Thessaloniki, Greece Abstract In this study a new innovative method of earthquake-resistant strengthening of

Related Documents:

behringer ultra-curve pro dsp 24 a/d- d/a dsp ultra-curve pro ultra- curve pro 1.1 behringer ultra-curve pro 24 ad/da 24 dsp ultra-curve pro dsp8024 smd (surface mounted device) iso9000 ultra-curve pro 1.2 ultra-curve pro ultra-curve pro 19 2u 10 ultra-curve pro ultra-curve pro iec . 7 ultra-curve pro dsp8024 .

TABLE OF CONTENTS: XPRESS ULTRA FIELD TERMINATION CONNECTORS SC Xpress Ultra Fiber Connectors Page 2 LC Xpress Ultra Fiber Connectors Page 3 ST Xpress Ultra Fiber Connectors Page 3 CLEANING & INSPECTION Optical Connector Contamination Pages 5 - 6 Xpress Ultra Cleaner Pages 7 - 8 Xpress Ultra Cleaner Replaceable Cartridge Page 8 Xpress Ultra

Properties of strain hardening ultra high performance fiber reinforced concrete (UHP-FRC) under direct tensile loading. Cement and Concrete Composites, 48, 53-66. Applications of Fiber Reinforced Concrete Fiber reinforced concrete are primarily used for applications that toughness of

Glass Fiber Reinforced Polymer (GFRP) is a fiber reinforced polymer made of a plastic matrix reinforced by fine fibers of glass. Fiber glass is a lightweight, strong, and robust material used in different industries due to their excellent properties. Although strength properties are somewhat lower than carbon fiber and it is less stiff,

fiber-reinforced concrete using ASTM C1018 (1998) standard test. The performance of the specimens reinforced with fibers are compared with that of the specimens reinforced with welded-wire fabric (WWF), with the purpose of determining if fiber-reinforced

Jun 01, 2020 · FIBER TYPE The first step to choosing the right fiber is to understand the type of fiber required for your application. The main standards for fiber reinforced concrete are ASTM C 1116 and EN14889. ASTM C 1116, Standard Specification for Fiber Reinforced Concrete, outlines four (4) classifications of fiber reinforced concrete;

Recommended Practice for Glass Fiber Reinforced Concrete Panels - Fourth Edition, 2001. Manual for Quality Control for Plants and Production of Glass Fiber Reinforced Concrete Products, 1991. ACI 549.2R-04 Thin Reinforced Cementitious Products. Report by ACI Committee 549 ACI 549.XR. Glass Fiber Reinforced Concrete premix. Report by ACI .

such as Ultra High Performance Fiber Reinforced Concrete (UHPFRC), for the strengthening of existing Reinforced Concrete (RC) structures. For this reason, an extensive experimental study on the properties of the material and the application for strengthening of RC beams has been conducted. More specifically, parameters such the