AIR LOCKSIMPLEX OFFERS SOLUTIONSENCLOSURE SYSTEMSOne Source Environmental LLCCleanroom Consulting/Testing107 Catamount DriveMilton, VT ey will expand, change or reconfigure easily to accommodateevolving requirements.you can assemble a functional 10’ x 10’ cleanroom in lessthan one hour.They adapt to a variety of filtration systems and lighting configurations.They accept a wide variety of wall materials including soft clearvinyl, colored and anti-static vinyl, rigid ABS sheets, acrylic, screensand even aluminum panels.Our cleanrooms can be completely disassembled and stored, expanded orreconfigured by adding or subtracting latch-together, lightweight modularsections.modular cleanrooms meet the ISO 14644-1 classifications for ISOClass 8 (Class 100,000) to ISO Class 4 (Class 10) and can be customdesigned to meet your particular application.Offers Many UsesHospitals and Health Care - Use for infectious disease control, inhalation andtreatment rooms, in both positive and negative pressure environments. ultra-violetvinyls protect light-sensitive laboratory experiments.Semiconductor Manufacturing - From mini-environments to large, selfcontained cleanrooms, can provide a room of any size and classification. isdesigned to keep assembly areas free of contaminants and dust. Static-free andnon-outgassing materials are also available.Hospitals andHealth CareMedical lsSemiconductorManufacturingIndustrial andManufacturingFood and BeveragePreparationIndustrial and Manufacturing - Use to create machinery enclosures. Excellent forwelding operations, laser procedures, paint operations and sound booths.Medical Device and Pharmaceutical Manufacturing - Use for processisolation to prevent cross contamination and control humidity andtemperature. can be adapted for ISO Class 8 (Class 100,000) to ISO Class 4(Class 10) cleanrooms with positive or negative pressure.Hazardous Materials - Set up area isolation for emergency toxic waste cleanupand HazMat handling.Food and Beverage Preparation - adapts to virtually any configuration,including assembly lines and packaging. walls and anodized aluminum frames washdown quickly and easily.TM1CALL 1 800 854-7951 TODAY FOR A QUOTE, SPECIFICATIONS OR FREE DESIGN HELPwebsite: simplexisolationsystem.come-mail: sales@simplexis.net

ENCLOSURE MODELS 150/250Foam Seal - NEClosed-Cell PoronFoam Gasket1”1”Lock-inSplineVinyl Inserts AreTaut and Tight Cleans Like AnyRigid Material1”x 1” Tubing1”Vinyl InsertLocks IntoFrame2”Lock-inSplineClosed-CellFoam SealBillet AluminumCompressionLatchE1”x 2” Tubingfor taller roomsA Neoprene closed-cell foam gaskets sealframe-to-frame connections.B Insert materials lock into frame with an airtightseal; inserts cannot be knocked loose fromaccidental impacts. Cleaning is quick and easy.DC Frame construction with knock-togethercorners allows for replacement of individualparts.FBACD Numerous door options to accommodateindividual uses; pre-hung for quick assembly. E Ceiling frames with integrated 2” T-grid in 2’x4’standard openings latch into position in thesame manner as the walls. The 2’x 4’ openingscan accommodate various types of filtrationand lighting units.nFLightweight aluminum frames are available inanodized clearcoat. Epoxy powder-coatedframes are available.Basic Construction Featurescleanrooms assemble quickly with minimal use of tools! Manyapplications can be assembled in less than one hour. The latch-together system provides strong, positive connection at walls, corners, ceilings virtually every connection. Because of the modular design, enclosuresare equally effective in both permanent and temporary applications. Theycan be easily expanded or reconfigured to meet ever-changing demands.Wall Panel Insert Optionswall panels are available in many types of materials in manycombinations.OPTIONS: 50-50 walls feature clear tops with opaque color bottoms. Thicknesses include .040, .060, .080 and .120 mils. Panel options include standard vinyl, static dissipative andnon-outgassing, static dissipative vinyl. Colors include clear, frosted, amber tint, grey smoke tint, and opaquecolors - blue, grey, white, black and tan. 1/8” thick acrylic and polycarbonate panels available in clear and manycolors, as well as scratch resistant and anti-static coatings. Rigid PVC and ABS panels in various textures and colors.simple locking system means thatpanels install and remove easily. Laminated aluminum panels come in 1/8” and 1/4” thicknesses withvarious coating options. Polycarbonate thermo-insulated 1/4” insulated panels. insulated vinyl panels.TMCALL 1 800 854-7951 TODAY FOR A QUOTE, SPECIFICATIONS OR FREE DESIGN HELPwebsite: simplexisolationsystem.come-mail: sales@simplexis.net2

AIR LOCKDOOR AND VENTING OPTIONSENCLOSURE SYSTEMSdoors are pre-hung in their frames for quick and easy installation and areavailable in the same material as the walls.Single and Double-framed ABS and Vinyl Swing Doors - Features includecontinuous airtight gear hinges for effortless movement, lever door handles,and foam seals to ensure complete closure. Options include handles withlocking mechanisms and hydraulic closers.Sliding Doors - Available in single and double panels with anodized aluminumroller track, and magnetic and vinyl sweep seals. Option includes automaticclosing device.Strip Door - Available in many widths, thicknesses and colors, clear/frostnon-stick design for easy personnel and equipment passage.Bi-folding Curtain - Available with anodized aluminum or stainless steeltrack. Options include various thicknesses and materials and a choice ofmagnetic or dual lock closers.ABS Single Swing DoorVinyl Single Swing DoorDouble Swing DoorSliding DoorStrip DoorDouble Sliding DoorVenting Optionsseveral different types of air venting and exhaust systems for eitherpositive or negative pressure rooms.ABS Adjustable SlidingGrill - Can be adjustedto accommodate airflow requirements.Screen Mesh - Vinylcoated, non-particulating.screen mesh, as an optionon vinyl inserts only.Open Air Space - Framedopen air space availablewith vinyl flap to sealopening when room isnot pressurized.TM3CALL 1 800 854-7951 TODAY FOR A QUOTE, SPECIFICATIONS OR FREE DESIGN HELPwebsite: simplexisolationsystem.come-mail: sales@simplexis.net

F L O O R A N D W A L L AT TA C H M E N T S / M O D E L S 1 0 0 / 2 0 0 W A L L S Y S T E M STo insure a proper seal and safe operation of your cleanroom allwalls should be attached securely to the floor. features several differentattachment systems, all of which can be installed temporarily usingstructural adhesive foam tape or permanently by bolting to existing floors.FLOOR, WALL & CEILING ATTACHMENTSFloor Cleats secure cleanroom structures firmly tothe floor and ensure a proper seal. These areinstalled at all joints of the walls.U-track - Installs onwalls, holding panels inplace.1”1”Lock-inSplineAngle and Face Plate - Allowswall to be fastened to existingwall with face plate coveringgaps for cleanliness.wall panels can be used to divide existing rooms or create rooms utilizingexisting suspended ceilings. They attach easily and secure to existing ceilings, floors and walls with various wall fastening systems. Thissystem offers an economical and attractive alternative to high costconstruction that often requires permits. walls can also be designed aspermanent or moveable walls for use as safety or privacy screens.Free-stand panels can serveas privacy screens or safetydividers. Black panels confinelaser procedures. Amberconfines weldingprocedures.1”x 1” Tubing1”Foam Seal - NEClosed-Cell PoronFoam GasketAngle Fasteners - Can beinstalled on inside oroutside of walls, or bothif desired.2”Lock-inSplineVinyl Inserts AreTaut and Tight Cleans Like AnyRigid Material1”x 2” Tubingfor taller wallsWall divisions of any size panel can be easilymoved or added for future expansion.TMCALL 1 800 854-7951 TODAY FOR A QUOTE, SPECIFICATIONS OR FREE DESIGN HELPwebsite: simplexisolationsystem.come-mail: sales@simplexis.net4

AIR LOCKCEILING SYSTEMSENCLOSURE SYSTEMSGreater Strength, Larger RoomsThe standard ceiling is a fully integrated 2” T-bar. When assembling prefabricated modules, simply set the ceiling assembly onto the room andlatch it down. Ceiling accepts standard 2’ x 4’ ceiling tiles and components.Ceiling options include all-vinyl ceilings in both clear and colored materials,as well as framed openings for HEPAs and lights.Pre-assembledCeiling FrameModules2” Aluminum T Grid,Pre-gasketedThe standard suspended ceiling structure canaccommodate limited, medium and heavy ceiling loadneeds. The module frame components are structurallydesigned for easy assembly and able to adapt to variousroom configurations.Openings AcceptStandard 2’x4’Ceiling ComponentsPre-assembledOuter PerimeterFrameCeiling Support OptionsMedium-duty aluminum supportstruts measuring 2”x 4” areintegrated between ceiling panelsfor room widths up to 16 feetwide with limited ceiling loads.Stiffeners can be added toaluminum struts measuring 2”x 4”to accommodate larger rooms upto 18 feet wide with larger ceilingloads.Ceiling to Strut Connectoris used to connect existingceiling frames to standardstruts.Heavy-duty truss systems canbe added to standard struts toaccommodate spans up to 21 feetwide and heavier ceiling loads.Threaded rod suspenders supportceiling frames or struts fromany existing structure above forlarger rooms of any size. Ceilingloads are limited only by thenumber of attachments and thestrength of the existing ceiling.Ceiling Tile Hold Down isused to keep ceiling tilesfrom lifting and breakingthe seal from the ceilingframes.TM5CALL 1 800 854-7951 TODAY FOR A QUOTE, SPECIFICATIONS OR FREE DESIGN HELPwebsite: simplexisolationsystem.come-mail: sales@simplexis.net

D U A L - PA N E T E L E S C O P I N G / O P T I O N S A N D A C C E S S O R I E STelescopes Easily To Fit Existing Ceilings.telescoping walls are designed for temporary isolation enclo-sures anddividers. They are ideal for maintenance work within functioningcleanrooms. They are lightweight and set up in seconds. Doublesweep seals between sliding frames and closed-cell gasketing ensureadditional seals. Custom heights, frame finishes, gasketing and latches areavailable for different applications.FEATURES: Quarter-inch closed-cell foam conforms to ceiling for airtight fit. Chemical resistant neoprene seal creates airtight seal on sides. Vinyl sweep maintains seal between panes.Dual-Pane telescoping windows allow you to build a qualitycleanroom in a minimal amount of space.Standard Sizes: Height 7’- 9’, 8’- 12’ Easy-to-operate compression latches secure panes. A simple twist of locking knobs adjusts panels from 7’ to 9’ high in seconds. Vinyl panels snap into frame for an airtight seal (other materials available). Durable, lightweight, anodized aluminum frame.Standard Sizes: Width 2’, 3’, 4’, and 5’DDoor Modules With Strips, Bi-fold Curtains and FrameSwing Doors are available. The Dual-Pane telescopingpanels expand from seven to aslarge as nine feet in seconds,using a compression latch lockingmechanism. Custom widths andheights are also available.Corner SealFoot with LevelerC-Channel CeilingAttachmentT-Grid CeilingAttachmentOptions And Accessories For ProjectsWALL ACCESSORIES OPTIONS: Glove ports Pass-throughs Sliding or swinging access panels Shelving Equipment access ports Portable transportation carts Strip conveyor openings Epoxy powder-coated framingFlange glove or exhaust ports can be easilyadapted to system.transportation carts, designedfor safe and easy transportationof panels, can be custom sizedto fit your factory doorways.TMCALL 1 800 854-7951 TODAY FOR A QUOTE, SPECIFICATIONS OR FREE DESIGN HELPwebsite: simplexisolationsystem.come-mail: sales@simplexis.net6

AIR LOCKENCLOSURE SYSTEMSA P P L I C AT I O N S A N D C O N F I G U R AT I O N S / S P E C I F I C AT I O N Srooms and enclosures can be designed in all shapes and sizes,configured with internal and external anterooms or dividers. The possibilitiesare endless!Plenum RoomsMini-environmentsProduction Showrooms,Tradeshow DisplaysIndustrial ApplicationsArchitectural SpecificationsWarrantyWall and Ceiling PanelsPanels shall be fabricated for fast, clean installation; modular and interchangeablefor future expansion. Frames are extruded 1” tubing clear finished anodized aluminum or epoxy powder-coated white. Frame shall interconnect usingcompression tongue latches unless otherwise specified.Panel inserts are standard .040 mil, optically clear flexible vinyl, installed using afully gasketed bonded hook-bead system to provide an airtight seal. Other types ofwall inserts available. Refer to page 2 for additional information.Flame retardancy meets UL 94 V-O and NFPA 701 flame test criteria. Some insertpanel materials will meet more stringent flame tests. Consult with factory for yourrequirements.Warrantywarranty for products to be free of manufacturing defects and againstproduct failure of any kind for a period of one year from date of ship-ment.This includes premature yellowing or curling of strips (excluding thosecomponents that do not have UV protection - see sales rep for details).This warranty is limited to the repair or replacement of vinyl strips, vinylpanels or softwall materials and/or attaching hardware, and does notinclude damage resulting from accident or malicious misuse. This warrantyfurther applies only when the recommended material thickness andwidth are used for the originally specified application. Further, itapplies only to doors, softwalls or frame systems which are properlyinstalled in accordance with Simplex installation instructions. Additionalextended warranty may be avail-able on certain applications. Seeindividual application sheets or ask your representative. lifetimeguarantee applies to first 3 inches of strip where stress is the greatestand attaches to the mounting hardware. Remainder of strip applies to 1year warranty.Structural PostsShall be extruded 6063-T5 clear finished anodized aluminum. Posts function as cornerconnectors for wall panels and as supports for ceiling joists. Posts also designed toserve as raceways for electrical, computer and telephone cable lines.Doors and FramesShall be pre-hung in frames extruded from 6063-T5 clear finished anodized aluminumand/or epoxy powder-coated finishes. Many types of doors are available. Refer todoor section on page 3.TMSimplex Strip Doors, Inc.14500 Miller Ave.Fontana, CA 92336ISOLATION SYSTEMSToll Free: 800 854-7951FAX: 909 429-0217website: simplexisolationsystem.come-mail: sales@simplexis.netExpect a Full Measure of Quality.Distributed By Copyright Simplex Strips Doors, Inc., 2013.Patent Number 4,312,396 and other patents pending.Specifications subject to change without notice.Lexan is a registered trademark of GE.AES-103-0413-10M

The standard suspended ceiling structurecan accommodate limited, medium and heavy ceiling load . strength of the existing ceiling. Ceiling to Strut Connector is used to connect existing ceiling frames to standard struts. Pre-assembled . Easy-to-operate compression latches secure panes.

Related Documents:

Simplex fire alarm control units can be custom-configured to each facility’s specifications and capacity requirements. As an additional convenient option, Simplex 4100ES control units are custom-built so they are ready t

cubic feet we have, and the enclosure is now 1.79 cubic feet. Since the recommended sealed enclosure for the Punch Power 12" DVC subwoofer is 1.25 cubic feet to 1.75 cubic feet, we're just about right on with the enclosure! However, if we were trying to make a ported enclosure that was 2.0 cubic feet, we'll need to make the enclosure

the enclosure's material and medium of insulation lining. To put this in perspective, a temperature difference of 15 F between the enclosure air and ambient air can contribute to 5.1 BTU/H for every square foot of surface area of your enclosure. Assuming a medium-sized enclosure, this translates to almost 220 BTU/H of additional heat that

Air flow direction 3 Enclosure unit partition design 4 Partition design guide 4 Partitions when installing with an optional . media player 5 Inlet and outlet types 6 Total open area of the ventilation holes and ratio 6 Single enclosure unit 7 1 x N one-side enclosure unit 9 Double-sided enclosure unit 10 Precautions for enclosure unit designing 11

2. Based on the type of enclosure required for the application, locate the minimum enclosure size from table 7 that will dissipate the watts loss of the drive selected in step 1. (Note that NEMA 1 is vented enclosure whereas NEMA 3, 3R, 4, 4X, and 12 are not vented.)1 3. Ensure that the selected enclosure is large enough to house

The heat generated in an enclosure varies and depends on the equipment mounted in the enclosure and the application. In order to calculate Temperature Rise, this heat input or power input must be known. This information can be obtained from the component manufacturers of components to be installed in the enclosure. Enclosure Temperature Rise (DT)

Prices subject to change without notice. Specifications subject to change without notice. Orders subject to acceptance by EcoWater Systems, LLC. Effective 05/01/17 4-2 Form No. 999701-NP VIP 1E Control – Simplex PVC Valve Nest Softener Epoxy Lined Steel Tank – Simplex Features: Simplex delayed or immediate regeneration. Hard water bypass

This Simplex Orifice Plate Holder is designed in 3 - 4 inch line sizes for high pressure measurement in applications such as production wells, injection systems and recycling operations. Heavy-duty construction throughout enables the fitting to handle pressures up to 10,000 P.S.I. The Daniel Simplex Orifice Plate Holder uses universal sizeFile Size: 702KBPage Count: 10