PowerProtect DD Virtual Edition onPremisesVersion DDVE 4.0Installation and Administration GuideREV 05March 2020

Copyright 2016-2020 Dell Inc. or its subsidiaries. All rights reserved.Dell believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS-IS.” DELL MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KINDWITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBEDIN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE.Dell Technologies, Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the propertyof their respective owners. Published in the USA.Dell EMCHopkinton, Massachusetts 01748-91031-508-435-1000 In North America 1-866-464-7381www.DellEMC.com2PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

CONTENTSRevision history57PrefaceChapter 1Introducing DDVE9Introducing DDVE. 10DDVE features .10Chapter 2Deploying DDVE13Managing DDVE .14Supported virtual environments.14Provisioning physical storage.14Raw physical storage capacity requirements . 15Managing SSD cache tiers.15SSD cache tier requirements. 16Best practices and limitations for cache tier storage. 16SSD cache tier considerations. 16Using the DAT tool to meet IOPS requirements for the SSD cache tier.17Using the DD System Manager to manage SSD cache tiers.18Using the CLI to manage SSD cache tiers.18Configuration requirements for DD Cloud Tier support .19Installing DDVE on premises.20Downloading the DDVE software . 20Installing DDVE on a VMware ESXi Server.21Installing DDVE on a VMware vCenter Server.21Installing DDVE in a Microsoft environment. 22Installing the DDVE on Hyper-V using the GUI. 25Configuring the DDVE on Hyper-V using the GUI.25Initial virtual machine configuration. 27Upgrading DD OS for DDVE. 28Powering on the virtual machine . 29Defining the DD system information for your site .29Deploying DDVE on KVM hypervisor.31Configuring other resources for DDVE on KVM. 31Deploying the DDVE on the KVM Hypervisor. 32Deploying DDVE on KVM using a reference script.32Deploying the DDVE on KVM using the Virtual Machine Manager. 34Best Practices for deploying the DDVE on a KVM hypervisor .35Chapter 3Completing Initial DDVE Configuration37Initial System Configuration . 38DDVE storage guidelines. 38Configuring DDVE in DD System Manager. 39Provisioning the storage with the CLI. 42Configuring the system for data access . 44PowerProtect DD Virtual Edition on Premises Installation and Administration Guide3

ContentsMonitoring performance. 44Configuring other resources .44Configuring optional software and internal licenses. 46Configuring optional system settings . 46Chapter 4Administering DDVE49Adding virtual storage . 50Extensions to DDOS for DDVE.50Storage performance evaluation. 50perf. 52system vresource.52DDVE-only commands. 53Modified DD OS commands. 54Unsupported DD OS commands .57Troubleshooting performance issues.624PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

Revision historyTable 1 DDVE 4.0 On Premises Installation and Administration Guide revision historyRevisionDateDescription05March 2020Editorial updates04January 2020Editorial updates03September 2019Editorial updates02March 2019Editorial updates01December 2018Initial Publication (with DD OS 6.2.0.5)PowerProtect DD Virtual Edition on Premises Installation and Administration Guide5

Revision history6PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

PrefaceAs part of an effort to improve its product lines, we periodically release revisions of its softwareand hardware. Therefore, some functions described in this document might not be supported by allversions of the software or hardware currently in use. The product release notes provide the mostup-to-date information on product features.PurposeThis manual describes how to install, configure, and administer DD Virtual Edition (DDVE) systems.AudienceThis manual is intended for use by both system administrators and general users of DD VirtualEdition.Related documentationThe following publications and websites provide additional information:lDD Operating System Release NoteslDD Operating System Initial Configuration GuideThis manual explains configuration steps that are common to hardware and virtual DD systems.lDD Operating System OS Command Reference GuideThis manual explains how to administer DD systems from the command line.lDD Operating System OS Administration GuideThis manual explains how to administer DD systems with the System Manager graphical userinterface.lDD Boost for OpenStorage Administration GuideThis manual explains how to use the DD Boost protocol for data transfer between backupsoftware and DD systems.lAvamar, DD and NetWorker Compatibility Guide: p/This website lists Avamar and NetWorker software support for DDVE.Where to get helpWe support, product, and licensing information can be obtained as follows:Product informationFor documentation, release notes, software updates, or information about products, go toOnline Support at https://support.emc.com.Technical supportFor technical support of this release of DDVE, go to Online Support at https://support.emc.com.Your commentsYour suggestions will help us continue to improve the accuracy, organization, and overall quality ofthe user publications. Send your opinions of this document to DPAD.Doc.Feedback@emc.com.PowerProtect DD Virtual Edition on Premises Installation and Administration Guide7

Preface8PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

CHAPTER 1Introducing DDVEThis chapter includes the following topics:llIntroducing DDVE. 10DDVE features . 10PowerProtect DD Virtual Edition on Premises Installation and Administration Guide9

Introducing DDVEIntroducing DDVEDD Virtual Edition (DDVE) is a software-only protection storage appliance: a virtual deduplicationappliance that provides data protection for entry, enterprise and service provider environments.Like any DD system, DDVE is always paired with backup software.DDVE runs the DD Operating System (DD OS), and includes the DD System Manager graphicaluser interface (GUI) and the DD OS command line interface (CLI) for performing systemoperations.DDVE includes the following features:lHigh-speed, variable length deduplication for a 10 to 30 times reduction in storagerequirementslUnparalleled data integrity to ensure reliable recovery, and seamless integration with leadingbackup and archiving applicationslDD Boost to speed backups by 50 percentlDD Encryption for enhanced security of datalDD Replicator for network efficient replication that enables faster time-to-DR readinessDDVE runs on two types of platforms:lOn premises, DDVE supports VMware, Hyper-V, KVM, and VxRail.lIn the cloud, DDVE also runs in the Amazon Web Services (AWS) (cloud and gov cloud), Azure(cloud and gov cloud), VMware Cloud (VMC) on AWS cloud platforms, and Google CloudPlatform (GCP).For more information about the features and capabilities of DD systems (both physical and virtual),see the DD Operating System Administration Guide.DDVE featuresResource configurations depend on your DDVE configuration. For features for cloud configurationswithin the admin guide for your specific cloud provider, see .lUp to 500 GB (evaluation version only)lUp to 8 TBlUp to 16 TBlUp to 32 TBlUp to 48 TBlUp to 64 TBlUp to 96 TBDDVE capacity is available in 1 TB increments starting at 1 TB, and up to 96 TB. The followingsections list supported DD protocols and features in DDVE.Supported DD protocolslCIFSlNFSlDD Boost (DD Boost) over IPlDD Boost (DD Boost) FSSupported DD features10PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

Introducing DDVElDD Boost managed file replication (MFR)lEncryptionlDD System Manager GUI for DDVE managementlSecure multitenancy (SMT) with Network Isolation Support in 6.0lDD Cloud Tier (supported in 16 TB, 64 TB, and 96 TB configurations)lHadoop Application AgentlKMIPlMore restricted IPtables settingslManaged file replication and MTree replicationlInstant access (supported on 16 TB and larger configurations only)lRetention Lock Governance Edition is supported on DDVE (both on premises and in the cloud)The DD OS Administration Guide, DD Boost OST Guide, and DD Boost for Partner IntegrationAdministration Guide provide additional information about the supported protocols and features.Unsupported DD featureslDD Boost over FClExtended retentionlDD High Availability (HA)--however, VMware and Hyper-V HA are supportedlNDMPlVTLlCollection replicationlDirectory replicationlInstant access (not supported on configurations smaller than 16 TB)lRetention Lock Compliance EditionlNet aggregationDD OS commands that are related to these unsupported features, and commands for hardwarefeatures that are not applicable to a virtual machine, are not supported on the DDVE platform.PowerProtect DD Virtual Edition on Premises Installation and Administration Guide11

Introducing DDVE12PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

CHAPTER 2Deploying DDVEThis chapter includes the following topics:llllllllllManaging DDVE . 14Supported virtual environments. 14Provisioning physical storage. 14Managing SSD cache tiers. 15Configuration requirements for DD Cloud Tier support . 19Installing DDVE on premises. 20Defining the DD system information for your site . 29Deploying DDVE on KVM hypervisor. 31Configuring other resources for DDVE on KVM.31Deploying the DDVE on the KVM Hypervisor.32PowerProtect DD Virtual Edition on Premises Installation and Administration Guide13

Deploying DDVEManaging DDVEUse the VMware vSphere client software, the VMware vSphere Web client, or Hyper-V Managerto install a DDVE instance and define its virtual hardware, including CPUs, memory, networkinterfaces, and virtual disks.The DD System Manager provides a configuration wizard to guide you through the steps requiredto configure DD OS after the virtual appliance is installed.Once DDVE is configured and running, you can access the system console to run DD OScommands by using the VMware vSphere Web client or Hyper-V Manager. You can also administerthe DDVE by using a terminal emulator or ssh command to use the CLI.The default login credentials for the DDVE instance are:lUsername: sysadminlPassword: changeme or the password specified during deploymentNote: The system sends an alert if an RSA DPM client certificate is within 15 days of expiring.Supported virtual environmentsDDVE is supported in the following virtual environments:lMicrosoft Windows Server 2012 R2 with Hyper-V.lKVM hypervisor on supported Linux distributionslVMware ESXi servers, either standalone or managed by VMware vCenter, versions 5.5, 6.0,and 6.5 with the corresponding versions of the VMware vSphere client application.Note: DDVE supports virtual hardware versions of virtual machines up to the latest version ofthe ESXi in use, and minimum of version 10. Consult VMware latest documentation for anyvirtual hardware version upgrades.Table 2 Supported Virtual HardwareESXi VersionUp to Virtual Hardware versionESXi 6.513ESXi 6.011ESXi 5.510Note: The OpenVMTools are pre-installed on the DDVE image. When you update the DD OSsoftware on the DDVE from within the DD OS environment, any necessary updates to theOpenVMTools are installed automatically. It is not possible to update OpenVMTools on thevirtual machine from outside DD OS.The hypervisor user needs read-only privileges on the data center object where the server orcluster hosting the DDVE instance resides.For information about compatibility with VMware or Microsoft products, visit the support portal athttps://support.emc.com.Provisioning physical storageYou can provision storage on an ESXi or Windows Hyper-V server to host the DDVE instance.14PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

Deploying DDVENote: Ensure that the disks provisioned in VMware are configured as "Independent PersistentDisks."Raw physical storage capacity requirementsThe following table shows the raw storage capacity required to provide the net usable capacity.For raw capacities not listed, use the same raw capacity in TiB as the usable capacity.For example:lTo net 40 TB usable capacity, provision 40 TiB.lFor 5 TB capacity with 8 TB configuration, provision 5 TiB.Note: The capacity in vCenter or Hyper-V manager is listed in TiB. When you create a 1 TBvirtual disk in vCenter, a storage capacity of 1 TiB is allocated.This table does not apply to configurations with DD Cloud Tier.Table 3 Raw physical capacity requirementsUsable Capacity (TB)Raw Capacity (GiB) at each 921692169216Table 4 Conversions for raw physical capacityGiBTB10.001074TBTiB10.909495Managing SSD cache tiersThe SSD cache tier for DDVE systems uses flash technology to create cache tiers for file systemmetadata. The SSD cache is a low latency, high input/output operations per second (IOPS) cacheto accelerate metadata and data access.Note: The minimum software version required for HyperV and KVM is DD OS 6.2.x.x.PowerProtect DD Virtual Edition on Premises Installation and Administration Guide15

Deploying DDVEThe SSD cache tier provides the SSD cache storage for the file system. Caching the file systemmetadata on SSDs improves I/O performance for both traditional and random workloads.When the cache tier is first created, a file system restart is required if the cache tier is added whenthe file system is running. You can add cache to a live system without disabling the file system. Ifthe file system does not been exist or if the file system is not enabled, creating or enabling the filesystem after adding the cache tier activates the SSD cache.Note:lIf encryption is enabled for the active tier, data cache and DM cache are not enabled.lWhen the remaining number of spare blocks gets close to zero, the SSD enters a read-onlycondition. DD OS treats the drive as read-only cache and sends an alert.SSD cache tier requirementsReview the SSD requirements for your specific DDVE model. Note that SSD cache tier is notsupported for configurations less than 16 TB.Table 5 Supported SSD models and requirementsDDVE ModelSSD RequirementDDVE 16 TB160 GBDDVE 32 TB320 GBDDVE 48 TB480 GBDDVE 64 TB640 GBDDVE 96 TB960 GBBest practices and limitations for cache tier storageYou should be aware of the following best practices and limitations when adding storage to thecache tier:lAdding storage to the cache tier requires a CAPACITY license in the system.lAdd only SSD type disks to the cache tier. If the device is not recognized as an SSD disk, usethe force option in the storage add tier cache CLI command. For example, storageadd tier cache dev force.lYou must add at least a 100 GB disk to the cache tier.lIf the tier is under provisioned when the file system is enabled, you must add the requiredcache capacity.lIf the tier is over provisioned, adding the cache tier storage fails.SSD cache tier considerationsBe aware of the following best practices and limitations for SSD cache tiers:16lWhen the number of spare blocks remaining gets close to zero, the SSD enters a read-onlycondition and DD OS treats the drive as read-only cache and sends an alert.lWhen SSDs are deployed within a controller, the SSDs are treated as internal root drives. Theyappear as enclosure 1 in the output of the storage show all command.PowerProtect DD Virtual Edition on Premises Installation and Administration Guide

l VMware ESXi servers, either standalone or managed by VMware vCenter, versions 5.5, 6.0, and 6.5 with the corresponding versions of the VMware vSphere client application. Note: DDVE supports virtual hardware versions of virtual machines up to the latest version of the ESXi in use, and minimum of version 10. Consult VMware latest documentation .

Related Documents:

Microsoft Exchange Backup and Recovery . . 1.1.5 SQLite database . Dell EMC PowerProtect software is the next-generation data management platform that transforms traditional data protection into comprehensive data management. PowerProtect software is defined with

DD series encryption software overview 6 Dell EMC PowerProtect DD Series Appliances: Encryption Software H18559 Easy integration: -Supports leading backup and archive applications -Supports leading enterprise applications for database and virtual environments -Allows simultaneous use of VTL, NAS, NDMP, and DD Boost 1.1 Encryption types offered by DD series encryption software

Command Line Interface for DDMC 155 . n Monitor operational status of configured replications and set thresholds that generate alerts (sent to the alerts log) when replications lag . 10 Dell EMC PowerProtect DD Management Center Installation and Administration Guide.

PowerProtect Data Manager Versi

Please see Dell EMC PowerProtect Data Manager Amazon Web Services Deployment Guide for more details on the different architecture models. 1.3 AWS data-transfer costs Amazon charges the monthly fee based on the amount and types of data transferred by Data Manager and DDVE in AWS cloud.

a Microsoft Hyper-V environment Support for the analyze operation for PowerProtect Data Manager backups (Filesystem, VMware, and Oracle) is enabled . Reference Architecture 11 CyberSense host information in copy details Cyber Recovery provides information about the analysis host which analyzed the copy in

Dell EMC PowerProtect DD Series Appliances: Hardware Assisted Compression . Compatibility DD Boost clients can continue to operate without any changes or performance impact with both DD series appliances and previous generation Data Domain appliances. DD Boost clients are transparent to the compression process within DD series appliances.

backups are compromised. Hence, it becomes crucial to have backup secure if there is any attack. Dell EMC PowerProtect Cyber Recovery software provides this protection by replicating backup data from a production system to a secure air-gapped vault system. This white paper focuses on the steps to recover Dell EMC