Modular Endo Heads - Alfaxa

2y ago
13 Views
2 Downloads
743.59 KB
5 Pages
Last View : 7d ago
Last Download : 3m ago
Upload by : Lee Brooke
Transcription

ORDERINGSelf-Centering Bipolar Clinically proven since 1984Ease of assemblyPositive eccentricityAvailable for 28 or 22.225mm femoral headsAccurate fit with sizes ranging from 39-65mm*Modular CathcartUnipolar ImplantsSelf-CenteringBipolar ImplantsModular Endo HeadTrialsCat. No.Cat. No.Cat. No.SizeUnipolar 60-00060mm1*39, 40, 63 and 65mm sizes are available by special orderPositive Eccentricity and Its Effect on WearNot all bipolars work like the Self-Centering Bipolar. The difference is positiveeccentricity. As downward force is applied, the centers align themselves to theproper anatomic position and proper load distribution. In terms of wear, thebipolar’s dual articulation uses primary internal articulation to help reducesecondary acetabular articulation and associated acetabular wear.1 Inner head center of rotation2 Outer head center of rotationF Force of patient weightF1 Reaction forceModular Cathcart Unipolar Clinically proven since 1990 1Neck length adjustment with tapered sleevesEase of assemblyOrthocentric design helps preserve acetabular cartilageAccurate fit with sizes ranging from 41- 60mmI N F O R M AT I O NModular CathcartUnipolar Tapered SpacersCat. No.SizeTapered Spacers,12/14 Articul/eze 1363-08-000-3mm1363-10-000 0mm1363-12-000 5mm1363-14-000 10mmTapered Spacers,10/12 Taper1363-34-000 0mm1363-35-000 5mm1363-36-000 10mmOrthocentric DesignThe design of the Modular Cathcart Unipolar was derived from an anatomic studySize28mm I.D. Bipolar Heads1035-39-000* 39mm1035-40-000* * 63mm1035-65-000* 65mm22.225mm I.D. Bipolar 55-00055mm1037-56-00056mm1037-57-00057mmCat. No.SizeTrial 1mm2055-63-000*63mm2055-65-000*65mmSizeHead Sizers2055-18-00041 - 46mm2055-20-00047 - 51mm2055-22-00052 - 56mm2055-24-00057 - 61mmCat. -0002055-14-0002055-16-000Liner Release ForcepsInstrument CaseTrial Handle, StraightTrial Handle, AngledAdapter Removal Inst.Bipolar RetainingClip, 28mmBipolar RetainingClip, 22.225mm2055-17-000Modular Endo HeadsS E LF- C E NTE R I NG B I P O L AR / MO D U L AR CATHCART U N I P O L ARTrial Spacers, 12/14 Articul/eze2038-16-000-3mm2038-18-000 0mm2038-20-000 5mm2038-22-000 10mmTrial Spacers,2038-04-0002038-06-0002038-08-000of the femur.2 Since the natural femoral head is nonspherical, the Modular CathcartUnipolar design features material added to the apex of the sphere, creating anModular Endo HeadInstruments10/12 Taper 0mm 5mm 10mm*Special order onlyReferences1. Data on file at DePuy Orthopaedics, Inc.2. Cathcart, R.F.: AAOS, 1972.For more information about Modular Endo Heads, visit our web site at www.jnjgateway.com/endoheads.QUALITYorthocentric geometry. This design is intended to mimic normal femoral head anatomyWITHOUTand help maintain the circulation of the synovial fluid. This circulation helps toCOMPROMISElubricate and nourish the articular cartilage during normal weightbearing activities.1M09050601-97-050 (Rev. 2)Printed in USA. 2000 DePuy Orthopaedics, Inc. All rights reserved.

ORDERINGSelf-Centering Bipolar Clinically proven since 1984Ease of assemblyPositive eccentricityAvailable for 28 or 22.225mm femoral headsAccurate fit with sizes ranging from 39-65mm*Modular CathcartUnipolar ImplantsSelf-CenteringBipolar ImplantsModular Endo HeadTrialsCat. No.Cat. No.Cat. No.SizeUnipolar 60-00060mm1*39, 40, 63 and 65mm sizes are available by special orderPositive Eccentricity and Its Effect on WearNot all bipolars work like the Self-Centering Bipolar. The difference is positiveeccentricity. As downward force is applied, the centers align themselves to theproper anatomic position and proper load distribution. In terms of wear, thebipolar’s dual articulation uses primary internal articulation to help reducesecondary acetabular articulation and associated acetabular wear.1 Inner head center of rotation2 Outer head center of rotationF Force of patient weightF1 Reaction forceModular Cathcart Unipolar Clinically proven since 1990 1Neck length adjustment with tapered sleevesEase of assemblyOrthocentric design helps preserve acetabular cartilageAccurate fit with sizes ranging from 41- 60mmI N F O R M AT I O NModular CathcartUnipolar Tapered SpacersCat. No.SizeTapered Spacers,12/14 Articul/eze 1363-08-000-3mm1363-10-000 0mm1363-12-000 5mm1363-14-000 10mmTapered Spacers,10/12 Taper1363-34-000 0mm1363-35-000 5mm1363-36-000 10mmOrthocentric DesignThe design of the Modular Cathcart Unipolar was derived from an anatomic studySize28mm I.D. Bipolar Heads1035-39-000* 39mm1035-40-000* * 63mm1035-65-000* 65mm22.225mm I.D. Bipolar 55-00055mm1037-56-00056mm1037-57-00057mmCat. No.SizeTrial 1mm2055-63-000*63mm2055-65-000*65mmSizeHead Sizers2055-18-00041 - 46mm2055-20-00047 - 51mm2055-22-00052 - 56mm2055-24-00057 - 61mmCat. -0002055-14-0002055-16-000Liner Release ForcepsInstrument CaseTrial Handle, StraightTrial Handle, AngledAdapter Removal Inst.Bipolar RetainingClip, 28mmBipolar RetainingClip, 22.225mm2055-17-000Modular Endo HeadsS E LF- C E NTE R I NG B I P O L AR / MO D U L AR CATHCART U N I P O L ARTrial Spacers, 12/14 Articul/eze2038-16-000-3mm2038-18-000 0mm2038-20-000 5mm2038-22-000 10mmTrial Spacers,2038-04-0002038-06-0002038-08-000of the femur.2 Since the natural femoral head is nonspherical, the Modular CathcartUnipolar design features material added to the apex of the sphere, creating anModular Endo HeadInstruments10/12 Taper 0mm 5mm 10mm*Special order onlyReferences1. Data on file at DePuy Orthopaedics, Inc.2. Cathcart, R.F.: AAOS, 1972.For more information about Modular Endo Heads, visit our web site at www.jnjgateway.com/endoheads.QUALITYorthocentric geometry. This design is intended to mimic normal femoral head anatomyWITHOUTand help maintain the circulation of the synovial fluid. This circulation helps toCOMPROMISElubricate and nourish the articular cartilage during normal weightbearing activities.1M09050601-97-050 (Rev. 2)Printed in USA. 2000 DePuy Orthopaedics, Inc. All rights reserved.

RESPONDINGTOTHEA S S E M B LYSURGEONSelf-Centering Bipolar1Step 1The Self-Centering Bipolar and Modular CathcartAfter cleaning and drying the femoral neck trunnion, impactthe appropriate femoral head onto the stem with the femoralhead impactor.Unipolar Endo Heads add versatility to DePuy’ship fracture line. You asked for ease of assemblyand flexibility in using the heads with a variety ofStep 2stems, and we responded.2Snap the polyethylene liner over the implanted femoral head.Ease of Use in SurgeryWe also added simple modular endo headVery little pressure is required to snapinstrumentation with a varietythe bipolar insert over the femoralof trialing options to helphead. This easy assembly does notprovide the best fit. “Qualityaffect separation strength because theWithout Compromise” is the hallmark of our hipSelf-Centering Bipolar exhibits superiorfracture line and, together with exceptionalpullout strength (2180 Newtons).1service, it’s proof that we are committed toStep 33Place the shell over the liner and snap it into its locked position.An audible click will be heard when the locking ring snaps into place.Step 4meeting your orthopaedic needs.When combined with the wide rangeof DePuy femoral components andCheck the interlock of the components, and reduce the bipolarhead into the acetabulum.the surgeon’s preferred technique,the Self-Centering Bipolar can be acost-effective and efficient approachto femoral neck fractures andavascular necrosis.Modular Cathcart UnipolarStep 11After cleaning and drying the femoral neck trunnion, placethe tapered spacer onto it using firm manual pressure.Modular Tapered SpacersNeck length adjustment is achievedPatented trial heads alloweasy intraoperative trialing.*Step 22with the use of tapered spacers.The tapered spacers make theClean and dry the outer portion of the tapered spacer andplace the unipolar head onto it.Modular Cathcart Unipolar a cost-The Self-Centering Bipolar and Modular Cathcarteffective option with no compromiseUnipolar Heads are compatible with a widein patient fit.range of DePuy cemented and cementlessStep 3Impact the unipolar head onto the tapered spacer using thefemoral head impactor.hips, including the Excel Fracture Systemand ULTIMA , ULTIMA Fx, P.F.C. , Endurance and AML stems.Step 4Check the interlock of the components, and reduce the unipolarhead into the acetabulum.* Patent #5,888,2113

RESPONDINGTOTHEA S S E M B LYSURGEONSelf-Centering Bipolar1Step 1The Self-Centering Bipolar and Modular CathcartAfter cleaning and drying the femoral neck trunnion, impactthe appropriate femoral head onto the stem with the femoralhead impactor.Unipolar Endo Heads add versatility to DePuy’ship fracture line. You asked for ease of assemblyand flexibility in using the heads with a variety ofStep 2stems, and we responded.2Snap the polyethylene liner over the implanted femoral head.Ease of Use in SurgeryWe also added simple modular endo headVery little pressure is required to snapinstrumentation with a varietythe bipolar insert over the femoralof trialing options to helphead. This easy assembly does notprovide the best fit. “Qualityaffect separation strength because theWithout Compromise” is the hallmark of our hipSelf-Centering Bipolar exhibits superiorfracture line and, together with exceptionalpullout strength (2180 Newtons).1service, it’s proof that we are committed toStep 33Place the shell over the liner and snap it into its locked position.An audible click will be heard when the locking ring snaps into place.Step 4meeting your orthopaedic needs.When combined with the wide rangeof DePuy femoral components andCheck the interlock of the components, and reduce the bipolarhead into the acetabulum.the surgeon’s preferred technique,the Self-Centering Bipolar can be acost-effective and efficient approachto femoral neck fractures andavascular necrosis.Modular Cathcart UnipolarStep 11After cleaning and drying the femoral neck trunnion, placethe tapered spacer onto it using firm manual pressure.Modular Tapered SpacersNeck length adjustment is achievedPatented trial heads alloweasy intraoperative trialing.*Step 22with the use of tapered spacers.The tapered spacers make theClean and dry the outer portion of the tapered spacer andplace the unipolar head onto it.Modular Cathcart Unipolar a cost-The Self-Centering Bipolar and Modular Cathcarteffective option with no compromiseUnipolar Heads are compatible with a widein patient fit.range of DePuy cemented and cementlessStep 3Impact the unipolar head onto the tapered spacer using thefemoral head impactor.hips, including the Excel Fracture Systemand ULTIMA , ULTIMA Fx, P.F.C. , Endurance and AML stems.Step 4Check the interlock of the components, and reduce the unipolarhead into the acetabulum.* Patent #5,888,2113

ORDERINGSelf-Centering Bipolar Clinically proven since 1984Ease of assemblyPositive eccentricityAvailable for 28 or 22.225mm femoral headsAccurate fit with sizes ranging from 39-65mm*Modular CathcartUnipolar ImplantsSelf-CenteringBipolar ImplantsModular Endo HeadTrialsCat. No.Cat. No.Cat. No.SizeUnipolar 60-00060mm1*39, 40, 63 and 65mm sizes are available by special orderPositive Eccentricity and Its Effect on WearNot all bipolars work like the Self-Centering Bipolar. The difference is positiveeccentricity. As downward force is applied, the centers align themselves to theproper anatomic position and proper load distribution. In terms of wear, thebipolar’s dual articulation uses primary internal articulation to help reducesecondary acetabular articulation and associated acetabular wear.1 Inner head center of rotation2 Outer head center of rotationF Force of patient weightF1 Reaction forceModular Cathcart Unipolar Clinically proven since 1990 1Neck length adjustment with tapered sleevesEase of assemblyOrthocentric design helps preserve acetabular cartilageAccurate fit with sizes ranging from 41- 60mmI N F O R M AT I O NModular CathcartUnipolar Tapered SpacersCat. No.SizeTapered Spacers,12/14 Articul/eze 1363-08-000-3mm1363-10-000 0mm1363-12-000 5mm1363-14-000 10mmTapered Spacers,10/12 Taper1363-34-000 0mm1363-35-000 5mm1363-36-000 10mmOrthocentric DesignThe design of the Modular Cathcart Unipolar was derived from an anatomic studySize28mm I.D. Bipolar Heads1035-39-000* 39mm1035-40-000* * 63mm1035-65-000* 65mm22.225mm I.D. Bipolar 55-00055mm1037-56-00056mm1037-57-00057mmCat. No.SizeTrial 1mm2055-63-000*63mm2055-65-000*65mmSizeHead Sizers2055-18-00041 - 46mm2055-20-00047 - 51mm2055-22-00052 - 56mm2055-24-00057 - 61mmCat. -0002055-14-0002055-16-000Liner Release ForcepsInstrument CaseTrial Handle, StraightTrial Handle, AngledAdapter Removal Inst.Bipolar RetainingClip, 28mmBipolar RetainingClip, 22.225mm2055-17-000Modular Endo HeadsS E LF- C E NTE R I NG B I P O L AR / MO D U L AR CATHCART U N I P O L ARTrial Spacers, 12/14 Articul/eze2038-16-000-3mm2038-18-000 0mm2038-20-000 5mm2038-22-000 10mmTrial Spacers,2038-04-0002038-06-0002038-08-000of the femur.2 Since the natural femoral head is nonspherical, the Modular CathcartUnipolar design features material added to the apex of the sphere, creating anModular Endo HeadInstruments10/12 Taper 0mm 5mm 10mm*Special order onlyReferences1. Data on file at DePuy Orthopaedics, Inc.2. Cathcart, R.F.: AAOS, 1972.For more information about Modular Endo Heads, visit our web site at www.jnjgateway.com/endoheads.QUALITYorthocentric geometry. This design is intended to mimic normal femoral head anatomyWITHOUTand help maintain the circulation of the synovial fluid. This circulation helps toCOMPROMISElubricate and nourish the articular cartilage during normal weightbearing activities.1M09050601-97-050 (Rev. 2)Printed in USA. 2000 DePuy Orthopaedics, Inc. All rights reserved.

12/14 Articul/eze 1363-08-000 -3mm . of DePuy femoral components and the surgeon’s preferred technique, the Self-Centering Bipolar can be a . the appropriate femoral head onto the stem with the femoral head impactor. Step 2 Snap the polyethylene liner over the implanted femoral head. Step 3

Related Documents:

exo exo B HA D C H H H A C D B endo B A D C endo B A C D Endo vs. exo selectivity Endo transition state & adduct is more sterically congested thus thermodynamically less stable But it is normally the predominant product The reason is endo transition state is

C4 -exo C4 -endo C1 -exo C3 -exo C2 -endo C4 -endo O4 -exo C1 -endo C2 -exo C3 -endo S N T 3E 3T 4 4 E 0 4 0E 0T 1 1E 2T 2T 2E 1 3 3E 4T 3 4E 4T 0 0E 1T 0 1 1 2 2E T 3 2 FIGURE 3.7 Diagram showing the correlation between the phase angle Pand the ribose con-formation. Conformational angles of Pare divided into two categories, north (N) and south .

Astra Tech Thommen Medical System Implant. system Language Endo*system Ratio Light Footpedal Torque units Contrast Endo steps Endo parameters Implant. system Language Endo*system Ratio Light Footpedal Torque units Contrast System info Restore defaults 128:1 64:1 30:1 27:1

Exo isomer was eluted first closely followed by the endo isomer. Exo isomer exhibited tailing and sometimes continued to elute even after elution of the endo isomer was completed. Thus, the endo isomer was usually contaminated by the exo isomer. Usually, a repeated chromatography was needed to obtain a pure endo isomer. Scaled up experimental .

Figure 1: Endo-Trig vs Exo-Trig Cyclization 2 Figure 2: Baldwin’s Rules for Ring Closure: Classification of Ring-Closure Types 3 Figure 3: 5-Endo vs 5-Exo Trajectory for Ring Closure 4 Figure 4: Iodine Promoted Formal 5-Endo-Dig Cyclization of δ-Alkynyl-α-Ketoesters 5

The integration ratio is about 3:1 for 2.5 ppm vs. 2.3 ppm in the final spectrum. One arrives at this conclusion from noting that there are four possible stereoisomers for the final product, (exo,exo), (exo,endo), (endo,exo), and (endo,endo), where the descriptors refer to the orientation of the methyl

The Toro Company Residential & Commercial Whole Goods Irrigation Products 2019 Suggested List Prices – U.S. & Canada Effective October 15, 2018 Table of Contents SPRAY HEADS 1 LPS Series Low-Profile Spray Heads 1 570Z Series Low Pressure Spray Heads 1 570Z Series Spray Heads 1 570Z-XF Series Spray Heads 1 570Z-PR Series Spray Heads 2

The group work is a valuable part of systematic training and alerts people to other training opportunities. Most have been on training courses provided by a range of early years support groups and charities and to workshops run by individual settings. Some have gained qualifications, such as an NVQ level 3 or a degree in child development and/or in teaching. Previous meetings have focused on .