QUALITROL 505 ITM Intelligent transformer monitorAdvanced, accurate and intelligentmonitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal modeling of winding temperatures Superior temperature control for increased transformer loadingProduct SummaryDescription Advanced transformer monitor, easyto configure, control and track accurately allaspects of your power transformer. Dynamicloading analysis to optimize loading and maximizeasset life.Application Industry leader in remote and localmonitoring of oil-filled transformer and load tapchanger parameters. Advanced control of coolingsystems and alarms through intuitive ITMmanager interface.

QUALITROL 505 ITM intelligent transformer monitorImprove asset protection and utilization In addition to traditional mechanical monitoring and protection,electronic transformer monitoring improves reliability, safety,and the availability of key decision making information.Expanded capabilities and features are now available in one single device.Avoid installation, maintenance and capital cost on additional devices. Immediately know your transformer health with TransLife TransLife feature provides a dashboard of required critical information.Computes loss of asset life rate, life consumption and remaining asset lifeCritical Forecast feature determines the time remaining until a criticaltemperature is reached based on current conditionsMonitor your windings with TransLife Temperature Profiler feature provides the history of thetransformer’s temperatureOptimize loading and equipment life Improved accuracy gained by use of advanced calculated windingtemperature measurement permit safe operation at higher loads Automatic cooling bank switching normalizes fan and pump usagefor maximum life Pre-cooling functionality reduces damaging high temperatures producedby overloads. Adaptive setback improves cooling system efficiency by measuringambient temperature and then adapting cooling and alarm set pointsbased on temperature trends Low temperature lock-out insures oil pumps remain off at coldtemperatures, this prevents static electrification and arcing Seasonal setback allows for customized cooling schemes depending onthe time of the yearSimplify root cause analysis Continuous information of all important transformer operating parametersfor condition-based maintenance aids in “drilling down” to the root, fundamental cause of the problem Relay control contacts and “go/no-go” alarms serve as economicalmethod for remotely determining status of a transformerFlexibility Flexible modular inputs (compatible with RTDs, CTs, voltages, currentloops & switch contacts) enable all parameters of transformers to bemonitored in one integrated device.New matrix relays can be set to alarm based on set points, a matrix ofset points and difference calculations. Improves identification oftransformer issues and reduces false trips0-1mA or 4-20mA outputs provide information toSCADA systemsMultiple mounting options: control panel configurations; self-containedcorrosion/weatherproof enclosure configurations; 19 inch mountrack configurationsUtilizes digital protocols over RS-232 or RS-485Field upgradeable for future monitoring inputs

505 ITM intelligent transformer monitor capabilitiesMonitor and measureOil levelLoad currentPressureCooling systemLTCLoad tap changerThird party devicesTemperatureAnalyze and communicate ControlCooling system optimizationLocal and remote alarmsProgrammable relaysCooling system exerciserSeasonal set pointsAmbient forecasti InformationTransLife Predictive loadingSCADA outputs (0-1mA or 4-20mA)Digital communication (RS 485, RS 232)Protocols (DNP 3.0, MODBUS)Email info@qualitrolcorp.comwww.qualitrolcorp.com

QUALITROL 505 ITM intelligent transformer monitorTransLife , the report card for transformersGeneral Description TransLife feature provides a dashboard ofcritical information needed to effectively managetransformer operation ITM manager is an intuitive helpful toolto manage transformers, to provide data forcondition-based maintenance and to plancapital expenditures effectively Critical forecast feature estimates the time toreach critical temperature based on the presenttransformer load Temperature profiler records the time at varioustemperatures that relate to asset life, this informationis displayed graphically for quick identification of timespent at peak temperatures Monitoring a winding, the QUALITROL 505 ITMreceives inputs from oil, winding and ambienttemperature to report loss of life rates, lifeconsumption (daily and hourly), total loss of life andremaining asset lifeTransLife Monitoring awindingTransLife ControlContains all theselections of inputmeasurements forTransLife Consumed LifeComputes loss ofasset life rate, lifeconsumed, remainingasset life and hoursin operationCritical ForecastDetermines the timeremaining until acritical temperatureis reached based oncurrent conditionsTemperatureProfilerLogs the durationthat the transformeris at eachtemperature rangeTemperatureProfiler GraphGraphical representationof the transformer’shistorical temperatureRed bars provide quickindication of time spentat accelerated lifeconsumption

QUALITROL 505 ITM intelligent transformer monitor series505intelligent transformer monitorFor general transformer control Monitors and reports on important parameters such as liquidtemperature, winding temperature, load current, oil level,and mechanical alarms. The 505 ITM uses the same accessories and software as the biggerand very successful brother, the 509 ITM. This minimizes any retrainingto operate the 505 ITM.Email info@qualitrolcorp.comwww.qualitrolcorp.com

QUALITROL 505 ITM intelligent transformer monitorComponents and accessoriesPt and Cu resistant temperature devices (RTDs) Provides transformer temperature measurementsMany varieties available to custom fit hundredsof transformer applications with easy upgradeto different types of equipmentMagnetic RTDs available for easy retrofit whenwells are not availableAmbient RTD (103-047) For ambient temperature measurement within substation (close to transformer) Includes sun shield to prevent false readingsCurrent transformers (CTs) Measures current flow needed to calculatewinding temperature, monitor cooling systemsand suppport advanced functions Clip-on design simplifies installationPressure transducers (TRN-603-1) Monitors static tank pressure and can providesudden pressure protection(requires QUALITROL 930)

TECHNICAL SPECIFICATIONSPower supplyTypeUniversal; 90 to 264 watts VAC; 47-63 Hz, 40-290 VDCInput moduleparametersConsumption 30 watts AC IN; 15 watts DC INNumber of inputsAccepts up to 4 input modules, 2 fixed, 2 configurableAccuracy 0.5% full-scale input rangeRTD10 ohm copper & 100 ohm platinum-40 F to 248 F range (-40 C to 120 C)CT, winding temperatureUses clamp-on sensor; range 0 to 5, 10, 20 ampsAC voltage0 to 140 and 0 to 360 VAC rangesPotentiometerAccepts potentiometers from 5K to 15KDry switch contactMeasures a dry switch contact as either open or closedPowered switch contactOptically isolated; detects AC or DC from 120 to 250 voltsNumber of relays4 programmable, 1 system status, 1 relay for heater controlTypeForm C, 10 amps @ 120/240 VAC, 10 amps @ 30 VDCNumber of loops2 magnetically-isolated current loopsOutput relaysOutput currentloopTypeCustomer configurable in software to choose between 0-1 mA(max load 10,000Ω) and 4-20 mA (max load 450Ω)Communications RS232 port1 port for set-up communications located on the front panel;varying baud ratesRS485 port1 port, 4-wire optically isolated for digital protocolsUSB port1 type B (slave) for local setupProtocolsDNP 3.0 level 3 slave, Modbus RTU, ASCIIUser interfaceControl8 pushdown buttons located on front panelLocal display2 x 16 character backlit LCDEnvironmentalOperating temperature-40 F to 161.6 F (-40 C to 72 C)(-60 C when a heater is used)Storage temperature-58 F to 185 F (-50 C to 85 C)Humidity5% to 90% non-condensingShock10 G’s half-sine, in three orthogonal planesVibration60/120 Hz @ .004 inch displacement; 10/150 Hz at 1GImmunityDielectric strength2500 VAC, 60 seconds to groundSurge withstand capabilityIEEE C37.90.1Cond./radiated emissionsIEC 61000-6-1Cond./radiated RFIIEC 61000-6-2SafetyIEC 61010-1CE approvedYesEmail info@qualitrolcorp.comwww.qualitrolcorp.com

QUALITROL 505 ITM intelligent transformer monitorWeatherproof enclosurePanel mount19” rack mount 2010 QUALITROL Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice.All trademarks are properties of their respective companies, as noted herein. AP-M09-08A-01EN.Email: info@qualitrolcorp.comwww.qualitrolcorp.com

intelligent transformer monitor series. 505 intelligent transformer monitor For general transformer control Monitors and reports on important parameters such as liquid temperature, winding temperature, load current, oil level, and mechanical alarms. The 505 ITM uses the same accessories and software as the bigger

Related Documents:

QUALITROL 505 ITM Intelligent transformer monitor Advanced, accurate and intelligent monitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal modeling of winding temperatures Superior temperature control for increased transformer loading Product Summary

problems in medical health monitoring. This will ultimately help to protect people's health. Key Words: Intelligent filming, Medicine, Health, Monitoring. Introduction With the advent of cloud platforms and the Internet of Things (IoT) era, intelligent med-ical treatment has been developed by leaps and bounds. The emergence of various intelligent

telemetry 1.24 Service P threshold_migrator 2.11 Monitoring P tomcat 1.30 Monitoring P trellis 20.30 Service P udm_manager 20.30 Service P url_response 4.52 Monitoring P usage_metering 9.28 Monitoring vCloud 2.04 Monitoring P vmax 1.44 Monitoring P vmware 7.15 Monitoring P vnxe_monitor 1.03 Monitoring vplex 1.01 Monitoring P wasp 20.30 UMP P .

What is Media Monitoring and How Do You Use it Monitoring: a history of tracking media What is monitoring? Getting started with monitoring The Benefits and Uses of Monitoring Using media monitoring to combat information overload Tools to maximize monitoring and measurement efforts Using media monitoring to develop media lists

intelligent vehicles in recent years. Intelligent vehicles tech-nologies are based on the information of the ego vehicle and its surroundings, such as the lanes, roads, and other vehicles, using the sensors of intelligent vehicles [4], [5]. The sensors in intelligent vehicles can be divided into internal and external sensors.

Advanced metering for SMEs The Impact of advanced metering for SMEs 0 Executive summary 02 Introduction to advanced metering 7.06 The potential benefits 06 .2 Use of advanced metering in businesses 06 .3 SupplierPrinciples of advanced metering 07 .4 Analysing advanced metering data 07 .5 Sources of energy savings 08 .6 Advanced metering technology 08 .7 Advanced metering services 09

SIRIUS monitoring relays: Perfect protection of machines and systems Monitoring relays 3UG451 / 461 / 463 monitoring relays for line and single-phase voltage monitoring – as 3UG481 / 483 also for IO-Link 10 6* 3RR21/22 monitoring relays for direct mounting on contactors for multi-phase current monitoring – as 3RR24 also for IO-Link 12 7 .

The American Revolution Part One: The events leading up the Revolutionary War (1750 – 1775) Background Historically speaking, right now “we” are British. The Colonies are an extension of Britain, so we share their government, their identity, their pride, and also their enemies. There is NO United States of America. Taunton Flag, flown by colonists to show unity with the British crown .