Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200AEnclosed,Indoor applicationVAPrimaryH2120 V0VX112 VH10V200120(Volts)Secondary (Volts)12Input /Output Amps1.67 / 16.67X2WIRING CONNECTIONFrequencyPolarity60HzadditivePRIMARY :Noise levelWindingless than 40DBCopperApprovalsUL listedCSA approvedVOLTSCONNECT LINES TO :120H1-H2SECONDARY :CONNECT LINES TO :VOLTS12LETTERX1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200BEnclosed,Indoor applicationVAPrimaryH2120 V0VX124 VH10V200120(Volts)Secondary (Volts)24Input /Output Amps1.67 / 8.33X2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :120H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :24X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONCONNECTION DIAGRAMMODELTypeMC200CEnclosed,Indoor applicationVAPrimary200120(Volts)120 VH20VX1Secondary (Volts)120Input /Output Amps1.67 / 1.67H10V120 VX2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :120H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :120X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200DEnclosed,Indoor applicationVAPrimaryH2208 V0VX124 VH10V200208(Volts)Secondary (Volts)24Input /Output AmpsX20.96 / 8.33WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :208H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :24X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200EEnclosed,Indoor applicationVAPrimaryH2208 V0VX1120 VH10V200208(Volts)Secondary (Volts)120Input /Output Amps0.96 / 1.67X2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :208H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :120X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMH4MC200FEnclosed,Indoor applicationVAPrimaryH2H3H10VX2X4200120 / 240(Volts)Secondary (Volts)Input /Output Amps12 / 240VX11.67 , 0.83 / 16.67 , 8.33WIRING CONNECTIONFrequencyPolarity50 / 60HzadditiveNoise levelless than 40DBWindingPRIMARY :INTERCONNECT:VOLTSCopperUL listedCSA approvedApprovalsX3CONNECT LINES TO :120H1-H3 AND H2-H4H1-H4240H2-H3H1-H4SECONDARY :VOLTSX1-X4X1-X3 AND X2-X41224LETTERCONNECT LINES TO :INTERCONNECT:X1-X4X2-X3EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMH4MC200GH2H3H10VX2X4Enclosed,Indoor applicationVAPrimary200120 / 240(Volts)Secondary (Volts)Input /Output Amps16 / 320VX11.67 , 0.83 / 12.5 , 6.25WIRING CONNECTIONFrequencyPolarity50 / 60HzadditiveNoise levelless than 40DBWindingPRIMARY :INTERCONNECT:VOLTSCopperUL listedCSA approvedApprovalsX3CONNECT LINES TO :120H1-H3 AND H2-H4H1-H4240H2-H3H1-H4SECONDARY :VOLTSX1-X4X1-X3 AND X2-X432LETTERCONNECT LINES TO :INTERCONNECT:16X1-X4X2-X3EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200HEnclosed,Indoor applicationVAPrimaryH2240 V0VX124 VH10V200240(Volts)Secondary (Volts)24Input /Output Amps0.83 / 8.33X2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :240H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :24X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200IEnclosed,Indoor applicationVAPrimaryH2240 V0VX1120 VH10V200240(Volts)Secondary (Volts)120Input /Output Amps0.83 / 1.67X2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :240H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :120X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200JEnclosed,Indoor applicationVAPrimaryH10V277 VH2200277(Volts)0VX1Secondary (Volts)120 / 240Input /Output Amps0.72 / 1.67 , 0.83X2X3X4WIRING CONNECTIONFrequencyPolarityNoise levelPRIMARY :60Hzadditiveless than 40DBWindingCONNECT LINES TO :277H1-H2SECONDARY :CopperINTERCONNECT:VOLTSUL listedCSA approvedApprovalsVOLTSLETTERCONNECT LINES TO :X1-X3 AND UNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200KEnclosed,Indoor applicationVAPrimaryH10V347 VH2200347(Volts)0VX1Secondary (Volts)120 / 240Input /Output Amps0.58 / 1.67 , 0.83X2X3X4WIRING CONNECTIONFrequencyPolarityNoise levelPRIMARY :60Hzadditiveless than 40DBWindingCONNECT LINES TO :347H1-H2SECONDARY :CopperINTERCONNECT:VOLTSUL listedCSA approvedApprovalsVOLTSLETTERCONNECT LINES TO :X1-X4X1-X3 AND GSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200LEnclosed,Indoor applicationVAPrimaryH10V380 VH2200380(Volts)0VX1Secondary (Volts)120 / 240Input /Output Amps0.53 / 1.67 , 0.83X2X3X4WIRING CONNECTIONFrequencyPolarityNoise levelPRIMARY :50 / 60Hzadditiveless than 40DBWindingCONNECT LINES TO :380H1-H2SECONDARY :CopperINTERCONNECT:VOLTSUL listedCSA approvedApprovalsVOLTSLETTERCONNECT LINES TO :X1-X3 AND UNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMH4MC200MH2H3H10VX2X4Enclosed,Indoor applicationVAPrimary200208 / 416(Volts)Secondary (Volts)Input /Output Amps12 / 240VX10.96 , 0.48 / 16.67 , 8.33WIRING CONNECTIONFrequencyPolarity50 / 60HzadditiveNoise levelless than 40DBWindingPRIMARY :INTERCONNECT:VOLTSCopperUL listedCSA approvedApprovalsX3CONNECT LINES TO :208H1-H3 AND H2-H4H1-H4416H2-H3H1-H4SECONDARY :VOLTSX1-X3 AND X2-X41224LETTERCONNECT LINES TO :INTERCONNECT:X1-X4X1-X4X2-X3EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMH4MC200NEnclosed,Indoor applicationVAPrimaryH2H3H10VX2X4200208 / 416(Volts)Secondary (Volts)Input /Output Amps120 / 2400VX10.96 , 0.48 / 1.67 , 0.83WIRING CONNECTIONFrequencyPolarity50 / 60HzadditiveNoise levelless than 40DBWindingPRIMARY :INTERCONNECT:VOLTSCopperUL listedCSA approvedApprovalsX3CONNECT LINES TO :208H1-H3 AND H2-H4H1-H4416H2-H3H1-H4SECONDARY :VOLTSX1-X3 AND X2-X4120240LETTERCONNECT LINES TO :INTERCONNECT:X1-X4X1-X4X2-X3EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMH4MC200OEnclosed,Indoor applicationVAPrimaryH2H3H10VX2X4200240 / 480(Volts)Secondary (Volts)Input /Output Amps120 / 2400VX10.83 , 0.42 / 1.67 , 0.83FrequencyPolarityWIRING CONNECTION60HzadditiveNoise levelPRIMARY :CopperUL listedCSA approvedApprovalsINTERCONNECT:VOLTSless than 40DBWindingX3CONNECT LINES TO :240H1-H3 AND H2-H4H1-H4480H2-H3H1-H4SECONDARY :VOLTSX1-X4X1-X3 AND X2-X4120240LETTERCONNECT LINES TO :INTERCONNECT:X1-X4X2-X3EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONCONNECTION DIAGRAMMODELTypeMC200PEnclosed,Indoor applicationVAPrimary200480(Volts)Secondary (Volts)24Input /Output Amps0.42 / 8.33H2480 V0VX124 VH10VX2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :480H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :24X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200QEnclosed,Indoor applicationVAPrimaryH2480 V0VX1120 VH10V200480(Volts)Secondary (Volts)120Input /Output Amps0.42 / 1.67X2WIRING CONNECTIONFrequencyPolarity60HzadditivePRIMARY :Noise levelWindingless than 40DBCopperApprovalsUL listedCSA approvedVOLTSCONNECT LINES TO :480H1-H2SECONDARY :LETTERVOLTSCONNECT LINES TO :120X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200REnclosed,Indoor applicationVAPrimaryH10V600 VH2200600(Volts)Secondary (Volts)0VX112 / 24Input /Output AmpsX2X3X40.33 / 16.67 , 8.33WIRING CONNECTIONFrequencyPolarityPRIMARY :60HzadditiveNoise levelless than 40DBWindingCONNECT LINES TO :600H1-H2SECONDARY :CopperINTERCONNECT:VOLTSUL listedCSA approvedApprovalsVOLTSLETTERCONNECT LINES TO :X1-X3 AND NGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMMC200SH2600 V0VX124 VH10VEnclosed,Indoor applicationVAPrimary200600(Volts)Secondary (Volts)24Input /Output Amps0.33 / 8.33X2WIRING CONNECTIONFrequencyPolarity60HzadditiveNoise levelWindingPRIMARY :less than 40DBCopperCONNECT LINES TO :600H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :24X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONCONNECTION DIAGRAMMODELTypeMC200TEnclosed,Indoor applicationVAPrimary200600(Volts)Secondary (Volts)120Input /Output Amps0.33 / 1.67H2600 V0VX1120 VH10VX2WIRING CONNECTIONFrequencyPolarityNoise level60Hzadditiveless than 40DBWindingPRIMARY :CopperCONNECT LINES TO :600H1-H2SECONDARY :UL listedCSA approvedApprovalsVOLTSLETTERVOLTSCONNECT LINES TO :120X1-X2EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONCONNECTION DIAGRAMMODELTypeMC200VEnclosed,Indoor applicationVAPrimary200600(Volts)0VX1Secondary (Volts)120 / 240Input /Output Amps0.33 / 1.67 , 0.83H10V600 VH2X3X2X4WIRING CONNECTIONFrequencyPolarityNoise levelPRIMARY :60Hzadditiveless than 40DBWindingCONNECT LINES TO :600H1-H2SECONDARY :CopperINTERCONNECT:VOLTSUL listedCSA approvedApprovalsVOLTS240120/240LETTERCONNECT LINES TO :X1-X3 AND SINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONSINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERDESCRIPTIONMODELTypeCONNECTION DIAGRAMH4MC200WH2H3H10VX2X4Enclosed,Indoor applicationVAPrimary200120 / 240(Volts)Secondary (Volts)Input /Output Amps120 / 2400VX11.67, 0.83 / 1.67 , 0.83WIRING CONNECTIONFrequencyPolarity50 / 60HzadditiveNoise levelless than 40DBWindingPRIMARY :INTERCONNECT:VOLTSCopperUL listedCSA approvedApprovalsX3CONNECT LINES TO :120H1-H3 AND H2-H4H1-H4240H2-H3H1-H4SECONDARY :VOLTSX1-X3 AND X2-X4120240LETTERCONNECT LINES TO :INTERCONNECT:X1-X4X1-X4X2-X3EDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbaDIMENSIONS INCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

Marcus Transformer LTDPhone: 1-800-267-7376Fax: 1-866-205-7526Email: Info@marcustransformer.comMARCUSTECHNICAL DATASINGLE PHASE CONTROL TRANSFORMERPrimary TabsDESCRIPTIONMODELTypeMC200XEnclosed,Indoor ION DIAGRAM200347 / 380(Volts)Secondary (Volts)Input /Output AmpsH3H1H20V12 / 240.58 , 0.53 / 16.67 , 8.330VX3X1WIRING CONNECTIONFrequencyPolarity50 / 60HzadditiveNoise levelless than 40DBWindingPRIMARY :VOLTSCONNECT LINES TO :347H1-H2380H1-H3CopperUL listedCSA approvedApprovalsX4X2SECONDARY :X1-X3 AND X2-X412X1-X4X1-X4X2-X324LETTERCONNECT LINES TO :INTERCONNECT:VOLTSEDMOUNTINGSLOTSINCHES / MMabS0.25 x 0.5006.4 x 12.7T0.25 x 0.6256.4 x 15.9I HbDIMENSIONSaINCHES / 9.5FGH3.25(T)82.6I5.00(S)127.9JKLMSHIPWEIGHTLBS / KG7.003.2

CONNECTION DIAGRAM H2 H1 X1 0V 0V X2 120 V 12 V 0.25 x 0.500 MOUNTING INCHES / MM . 0.25 x 0.625 6.4 x 15.9 T a b a b H D E I TECHNICAL DATA MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: Info@marcustransformer.com. VA 200 . DESCRIPTION Type Enclosed,Indoor application Winding .

Related Documents:

WIRING DIAGRAM DIRECTORY WARNING: Wiring direct to battery not recommended. Install actuator after ignition switch, or master power switch. Diagram 1 Diagram 2 Diagram 3 Diagram 4 Diagram 5 Diagram 6 Diagram 7 Diagram 8 Diagram 9 Diagram 10 Diagram 11 Diagram 12 Diagram 13 Diagram 14 Diagram 15 On/Off, 12VDC, 3-wire/3-pin, SPST On/Off, 12VDC, 3 .

3. Instrument transformer: Used in relay and protection purpose in different instruments in industries . . Current transformer (CT) . Potential transformer (PT) . Open circuit and Short circuit Test on transformer . These two transformer tests are performed to find the parameters of equivalent circuit of transformer and losses of the transformer.

Transformer Design & Design Parameters - Ronnie Minhaz, P.Eng. Transformer Consulting Services Inc. Power Transmission Distribution Transformer Consulting Services Inc. Generator Step-Up Auto-transformer Step-down pads transformer transformer 115/10 or 20 kV 500/230 230/13.8 132 345/161 161 161 230/115 132 230 230/132 115 345 69 500 34 GENERATION TRANSMISSION SUB-TRANSMISSION DISTRIBUTION .

Transformer Lab 1. Objectives: 1.1 Comparison of the ideal transformer versus the physical transformer 1.2 Measure some of the circuit parameters of a physical transformer to determine how they affect transformer performance. 1.3 Investigate the ideal transformer and ca

transformer there are hysteresis and eddy current losses in transformer core. Theory of transformer on no-load, and having no winding resistance and no leakage reactance of transformer Let us consider one electrical transformer with only core losses. That means it has only core losses but no copper lose and no leakage reactance of transformer.

Step 13: Now click on the 2-Winding Transformer icon . Place the 2-winding transformer in the same way that you placed the previous two components. Join the primary of the transformer to the Main Bus. Double click the transformer icon and set the following properties: On the Info Tab o Change the transformer ID to "Main Transformer".

the distribution magnetic flux in the transformer. It has been used ANSYS Package Version 11 to model the distribution transformer.Table (1) shows the data of distribution transformer. 3.1 Transformer Geometry (Building and meshing): The transformer study is 250 kVA, three phase distribution core type "stacked core" transformer.

Alex’s parents had been killed shortly after he was born and he had been brought up by his father’s brother, Ian Rider. Earlier this year, Ian Rider had died too, supposedly in a car accident. It had been the shock of Alex’s life to discover that his uncle was actually a spy and had been killed on a mission in Cornwall. That was when MI6 had