FlexPod Datacenter with VMware vSphere6.5, NetApp AFF A-Series and FibreChannelDeployment Guide for FlexPod Datacenter with Fibre Channel SAN and VMware vSphere 6.5 and ONTAP 9.1Last Updated: August 30, 20181

2

About Cisco Validated DesignsThe CVD program consists of systems and solutions designed, tested, and documented to facilitate faster,more reliable, and more predictable customer deployments. For more information, visit:http://www.cisco.com/go/designzone.ALL DESIGNS, SPECIFICATIONS, STATEMENTS, INFORMATION, AND RECOMMENDATIONS(COLLECTIVELY, "DESIGNS") IN THIS MANUAL ARE PRESENTED "AS IS," WITH ALL FAULTS. CISCO ANDITS SUPPLIERS DISCLAIM ALL WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTY OFMERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROMA COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BELIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE ORINABILITY TO USE THE DESIGNS, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THEPOSSIBILITY OF SUCH DAMAGES.THE DESIGNS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USERS ARE SOLELY RESPONSIBLE FORTHEIR APPLICATION OF THE DESIGNS. THE DESIGNS DO NOT CONSTITUTE THE TECHNICAL OR OTHERPROFESSIONAL ADVICE OF CISCO, ITS SUPPLIERS OR PARTNERS. USERS SHOULD CONSULT THEIROWN TECHNICAL ADVISORS BEFORE IMPLEMENTING THE DESIGNS. RESULTS MAY VARY DEPENDING ONFACTORS NOT TESTED BY CISCO.CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, CiscoWebEx, the Cisco logo, DCE, and Welcome to the Human Network are trademarks; Changing the Way WeWork, Live, Play, and Learn and Cisco Store are service marks; and Access Registrar, Aironet, AsyncOS,Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, theCisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, theCisco Systems logo, Cisco Unified Computing System (Cisco UCS), Cisco UCS B-Series Blade Servers,Cisco UCS C-Series Rack Servers, Cisco UCS S-Series Storage Servers, Cisco UCS Manager, Cisco UCSManagement Software, Cisco Unified Fabric, Cisco Application Centric Infrastructure, Cisco Nexus 9000Series, Cisco Nexus 7000 Series. Cisco Prime Data Center Network Manager, Cisco NX-OS Software, CiscoMDS Series, Cisco Unity, Collaboration Without Limitation, EtherFast, EtherSwitch, Event Center, Fast Step,Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, iQuick Study,LightStream, Linksys, MediaTone, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, NetworkingAcademy, Network Registrar, PCNow, PIX, PowerPanels, ProConnect, ScriptShare, SenderBase, SMARTnet,Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, andthe WebEx logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States andcertain other countries.All other trademarks mentioned in this document or website are the property of their respective owners. Theuse of the word partner does not imply a partnership relationship between Cisco and any other company.(0809R) 2018 Cisco Systems, Inc. All rights reserved.3

Table of ContentsExecutive Summary . 10Solution Overview . 11Introduction . 11Audience . 11Purpose of this Document . 11What. 11Solution Design . 12Architecture . 12Physical Topology . 13Deployment Hardware and Software . 15Software Revisions . 15Configuration Guidelines . 15Physical Infrastructure . 16FlexPod Cabling . 16Network Switch Configuration . 20Physical Connectivity . 20FlexPod Cisco Nexus Base . 20Set Up Initial Configuration. 20FlexPod Cisco Nexus Switch Configuration . 22Enable Licenses . 22Set Global Configurations . 23Create VLANs . 23Add NTP Distribution Interface . 23Add Individual Port Descriptions for Troubleshooting . 24Create Port Channels . 25Configure Port Channel Parameters . 26Configure Virtual Port Channels . 27Uplink into Existing Network Infrastructure . 29Storage Configuration . 30NetApp All Flash FAS A300 Controllers . 30NetApp Hardware Universe. 30Controllers . 30Disk Shelves . 30NetApp ONTAP 9.1 . 31Complete Configuration Worksheet. 314

Configure ONTAP Nodes . 31Login to the Cluster . 40Zero All Spare Disks . 40Set Onboard Unified Target Adapter 2 Port Personality . 40Set Auto-Revert on Cluster Management . 41Set Up Management Broadcast Domain . 41Set Up Service Processor Network Interface . 42Create Aggregates . 42Verify Storage Failover . 43Disable Flow Control on 10GbE and 40GbE ports . 43Disable Unused FCoE Capability on CNA Ports . 44Configure Network Time Protocol . 44Configure Simple Network Management Protocol . 44Configure AutoSupport . 45Enable Cisco Discovery Protocol . 45Create Jumbo Frame MTU Broadcast Domains in ONTAP . 45Create Interface Groups . 45Create VLANs . 45Create Storage Virtual Machine . 46Create Load-Sharing Mirrors of SVM Root Volume . 46Create Block Protocol (FC) Service . 47Configure HTTPS Access . 47Configure NFSv3 . 48Create FlexVol Volumes . 48Create Boot LUNs . 48Schedule Deduplication . 49Create FC LIFs . 49Create NFS LIF . 49Add Infrastructure SVM Administrator . 49Server Configuration . 51Cisco UCS Base Configuration . 51Perform Initial Setup of Cisco UCS 6332-16UP Fabric Interconnects for FlexPod Environments . 51Cisco UCS Setup . 53Log into Cisco UCS Manager . 53Upgrade Cisco UCS Manager Software to Version 3.1(2f) . 53Anonymous Reporting . 53Configure Cisco UCS Call Home . 545

Configure Unified Ports . 54Add Block of IP Addresses for KVM Access . 56Synchronize Cisco UCS to NTP . 56Edit Chassis Discovery Policy . 58Enable Server and Uplink Ports . 58Acknowledge Cisco UCS Chassis and FEX. 59Create Uplink Port Channels to Cisco Nexus Switches . 60Create a WWNN Pool for FC Boot . 61Create WWPN Pools . 63Create VSAN . 66Create FC Uplink Port Channels . 68Create vHBA Templates . 70Create SAN Connectivity Policy . 73Create MAC Address Pools . 75Create UUID Suffix Pool . 78Create Server Pool . 79Create VLANs . 79Modify Default Host Firmware Package . 82Set Jumbo Frames in Cisco UCS Fabric . 83Create Local Disk Configuration Policy (Optional) . 83Create Network Control Policy for Cisco Discovery Protocol (CDP) and Link Layer Discovery Protocol (LLDP) . 85Create Power Control Policy .

FlexPod Datacenter with VMware vSphere 6.5, NetApp AFF A-Series and Fibre Channel Deployment Guide for FlexPod Datacenter with Fibre Chan-nel SAN and VMware vSphere 6.5 and ONTAP 9.1 Last Updated: August 30, 2018

Related Documents:

o VMware vSphere Web Client o DR to the Cloud services Optional Features: o VMware vSphereSDKs o vSphere Virtual Machine File System (VMFS) o vSphere Virtual SMP o vSphere vMotion o vSphere Storage vMotion o vSphere High Availability (HA) o vSphere Distributed Resource Scheduler (DRS) o vSphere Storage DRS o vSphere Fault Tolerance o vSphere .

1 VMware vSphere and the vSphere Web Services SDK 15 . Introduction to vSphere Clusters 219 VMware DRS 219 VMware HA 220 VMware HCI 220 Creating and Configuring Clusters 221 . 17 vSphere Performance 263 vSphere Performance Data Collection 263 PerformanceManager Objects and Methods 265

1 VMware vSphere and the vSphere Web Services SDK 15 . Introduction to vSphere Clusters 220 VMware DRS 220 VMware HA 221 VMware HCI 221 Creating and Configuring Clusters 222 . 17 vSphere Performance 264 vSphere Performance Data Collection 264 PerformanceManager Objects and Methods 266

15. Create and manage a vSphere cluster that is enabled with VMware vSphere High Availability and VMware vSphere 16. Distributed Resource Scheduler 17. Discuss solutions for managing the vSphere life cycle 18. Use VMware vSphere Lifecycle Manager to perform upgrades to ESXi hosts and virtual machines 備註事項 1.

15. Create and manage a vSphere cluster that is enabled with VMware vSphere High Availability and VMware vSphere 16. Distributed Resource Scheduler 17. Discuss solutions for managing the vSphere life cycle 18. Use VMware vSphere Lifecycle Manager to perform upgrades to ESXi hosts and virtual machines 備註事項 1.

Deviations based on customer requirements from a given CVD or NVA are permitted if these variations do not create an unsupported configuration. The FlexPod program includes two solutions: FlexPod Express and FlexPod Datacenter. FlexPod Express. Offers customers an entry-level solution with technologies from

Flexpod: Cisco NetApp was ist ein Flexpod? Flexpod ist eine gemeinsame Architektur (CVD / NVA) Flexpod ist lösungsortientiert Die Flexpod Architektur ist vollständig dokumentiert: Design Guide Sizing Guide Wiring diagrams Bill of Materials Deployment Guide und, und, und

BREAKOUT TANK INSPECTION FORM Page 1 of 12 Form-10 Breakout Tank Inspection Form (Rev. 03/17/11 through Amdt. 195-95). . API 653 in proper conformance with the stresses, joint efficiencie (a) of withstanding the internal pressure produced by the hazardous liquid to be stored therein and any anticipated external loads. The repair/alteration history includes all data accumulated on a tank from .