R&S ATS1500CANTENNA TEST CHAMBER FORAUTOMOTIVE RADAR SENSORSSpecificationsData SheetVersion 03.00

Version 03.00, July 2020CONTENTSDefinitions . 3Specifications . 4Environmental conditions . 4Product conformity. 4R&S ATS1500C antenna test chamber . 4R&S ARC-TTP1 3D tilt-tilt positioner . 5R&S CATR-REFL1 CATR reflector, large size . 5R&S CATR-ALIC1 alignment structure, for CATR systems in selected chambers . 5R&S ARC-HARFM holder for R&S AREG100A monostatic frontend . 5R&S ATS-F230V power filter. 5R&S ARC-VENT1 ventilation 1 for R&S ATS1500C . 6R&S ARC-VENT2 ventilation 2 for R&S ATS1500C . 6R&S ARC-FARFM feedthrough for R&S AREG100A monostatic frontend . 6R&S TS-F1ETRR1 Ethernet feedthrough . 6R&S TS-F1SD259 D-Sub feedthrough . 6R&S TS-F1POBB2 banana plugs feedthrough . 6R&S TS-F1BCBB1 BNC feedthrough . 6R&S TS-F1U2BA1 USB 2.0 feedthrough . 6R&S ARC-DUTH1 universal DUT holder plate for R&S ATS1500C . 6R&S AREG100A automotive radar echo generator, frontend . 7Ordering information . 7Basic configuration . 7Additional options . 72Rohde & Schwarz R&S ATS1500C Antenna Test Chamber For Automotive Radar Sensors

Version 03.00, July 2020DefinitionsGeneralProduct data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operationSpecified environmental conditions metRecommended calibration interval adhered toAll internal automatic adjustments performed, if applicableSpecifications with limitsRepresent warranted product performance by means of a range of values for the specified parameter. These specifications aremarked with limiting symbols such as , , , , , or descriptions such as maximum, limit of, minimum. Compliance is ensured bytesting or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, driftand aging, if applicable.Non-traceable specifications with limits (n. trc.)Represent product performance that is specified and tested as described under “Specifications with limits” above. However, productperformance in this case cannot be warranted due to the lack of measuring equipment traceable to national metrology standards. Inthis case, measurements are referenced to standards used in the Rohde & Schwarz laboratories.Specifications without limitsRepresent warranted product performance for the specified parameter. These specifications are not specially marked and representvalues with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance isensured by design.Typical data (typ.)Characterizes product performance by means of representative information for the given parameter. When marked with , or as arange, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents themean value.Nominal values (nom.)Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast totypical data, a statistical evaluation does not take place and the parameter is not tested during production.Measured values (meas.)Characterize expected product performance by means of measurement results gained from individual samples.UncertaintiesRepresent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has beencalculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into accountenvironmental conditions, aging, wear and tear.Device settings and GUI parameters are designated with the format “parameter: value”.Non-traceable specifications with limits, typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.In line with the 3GPP/3GPP2 standard, chip rates are specified in million chips per second (Mcps), whereas bit rates and symbol ratesare specified in billion bits per second (Gbps), million bits per second (Mbps), thousand bits per second (kbps), million symbols persecond (Msps) or thousand symbols per second (ksps), and sample rates are specified in million samples per second (Msample/s).Gbps, Mcps, Mbps, Msps, kbps, ksps and Msample/s are not SI units.Rohde & Schwarz R&S ATS1500C Antenna Test Chamber For Automotive Radar Sensors3

Version 03.00, July 2020SpecificationsThe R&S ATS1500C is a compact and accurate antenna test chamber for RF testing and validation of 77 GHz/79 GHz automotiveradar sensor modules. It is based on the principle of a compact antenna test range (CATR) with a reflector, alignment structure andfeed antenna.The R&S ATS1500C operates with the R&S AREG100A automotive radar echo generator as measurement instrument. Its monostaticfrontend module is mounted into the chamber as the feed antenna. Further measurement instruments such as power sensors, signalanalyzers and signal generators can be attached to the chamber via the R&S AREG100A.Environmental conditionsTemperature rangeoperating temperature rangestorage temperature range 20 C to 30 C–10 C to 50 C75 % relative humidity,noncondensing at 10 C to 30 CElectromagnetic compatibilityin line withEU – EMC Directive 2004/108/ECElectrical safetyin line withEU – Machine Directive 2006/42/ECRestriction of the use of hazardoussubstances in electrical and electronicequipmentin line withEU – RoHS Directiveapplied harmonized standards:EN 61326-1EN 55011, group I, class B equipmentapplied harmonized and nonharmonizedstandards:EN ISO 12100EN 61010-1EN 61010-2-120applied harmonized standard:EN 50581Damp heatProduct conformityR&S ATS1500C antenna test chamberFrequency range 1Absorber 2Shielding effectivenessWeightDimensions (W H D) 3chambertypeattenuation of first order reflectionschamberWheelsDoor operation12346 GHz to 110 GHzpyramidal and flat55 dB 90 dB (typ.)approx. 500 kg (1102.31 lb)0.90 m 1.99 m 1.61 m(2.95 ft 6.5 ft 5.28 ft)4manually operated, electrical closingmechanismLimited by feeding structure, e.g. R&S AREG100A-B177S.From 40 GHz to 110 GHz.Dimensions include all mounts and handle bars attached with the chamber.Rohde & Schwarz R&S ATS1500C Antenna Test Chamber For Automotive Radar Sensors

Version 03.00, July 2020R&S ARC-TTP1 3D tilt-tilt positionerPositioner typeAngular resolutionStandard deviation positioner errorTilt angleMaximum tilt speedDUT load capabilityMaximum DUT sizeDUT fixture plateHardware triggeringApplication programming interfacesControlController communications interfaceInterfaces on inner axisresolution of feedbackmeasure of repeatabilityouter axisinner axisouter axisinner axisdimensionsthread sizeadjustable heightstepped manual rotation (orientation ofDUT polarization)connectionright side: communications with DUTleft side: power supply via controllerleft side: power supply via external powersupplyPower supply on inner axis via controllerPower supply on inner axis via externalpower supply2 axis, tilt-tilt0.03 (nom.)0.02 (meas.) 180 45 120 /s15 /s2.0 kg, centered40 cm 40 cm7.3 cm 7.3 cmM3 and M45 cm22.5 optional (requires BNC feedthrough)yes (C / C / C# / VB.NET / Python /MATLAB , )web interfaceEthernet1 Ethernet, 1 D-Sub 9-pole, 1 USB(optional)banana jacks (internal supply)banana jacks (optional)12 V, 2.5 A48 V, 5 AR&S CATR-REFL1 CATR reflector, large sizeFrequency range 4Quiet zone 5Surface roughnessSurface materialDimensionsreflectorØaverage amplitude taperaverage amplitude rippleRMS6 GHz to 90 GHz30 cm 1.5 dB (meas.) 0.5 dB (meas.) 1 µmgold plated54 cm 56 cmR&S CATR-ALIC1 alignment structure, for CATR systems in selectedchambersReflector tiltsAdjustment boltsAdjustment rangeAdjustment resolutionFeed goniometer rangeFeed goniometer resolutionleft-right and front-back3 2 0.1 30 0.1 R&S ARC-HARFM holder for R&S AREG100A monostatic frontendStepped manual rotationorientation of DUT polarization45 R&S ATS-F230V power filterPower ratingConnector typeInternal power outlet45rated voltagerated frequencyrated currentpower rating100 V to 230 V (AC) (–5 %/ 10 %)50 Hz to 60 Hz13 AC20100 V to 230 V (AC) (–5 %/ 10 %),50 Hz to 60 Hz, 2 AHigher/lower frequencies are possible with higher mean error inside the quiet zone.Measured at 76.5 GHz.Rohde & Schwarz R&S ATS1500C Antenna Test Chamber For Automotive Radar Sensors5

Version 03.00, July 2020R&S ARC-VENT1 ventilation 1 for R&S ATS1500CNominal voltage rangeOperating temperature rangeVentilation rateVentilation directionNoise levelRF shielding12 V to 28 V–20 C to 75 C140 m3/hinto the chamber38 dB(A)honeycombR&S ARC-VENT2 ventilation 2 for R&S ATS1500CNominal voltage rangeOperating temperature rangeVentilation rateVentilation directionNoise levelRF shielding12 V to 28 V–20 C to 75 C140 m3/hout of chamber38 dB(A)HoneycombR&S ARC-FARFM feedthrough for R&S AREG100A monostatic frontendFeedthrough typesLink cablesFunctionalityDSUBSMADSUBSMA4 SMA,1 D-Sub 9-pole,1 D-Sub 25-pole2 digital links4 coaxial RF cablescontrol interface between R&S AREGfrontend and R&S AREG base unitRF interfaces between R&S AREGfrontend and R&S AREG base unitR&S TS-F1ETRR1 Ethernet feedthroughFeedthrough typeFunctionalityrear sideside panel1 Ethernetto control 3D positionerDUT communicationsR&S TS-F1SD259 D-Sub feedthroughFeedthrough typeFunctionalityside panel1 D-Sub 9-pole,1 D-Sub 25-poleDUT communicationsR&S TS-F1POBB2 banana plugs feedthroughFeedthrough typeFunctionalityPower supplymaximum voltagemaximum current1 banana plugsDC power supply for DUT48 V5AR&S TS-F1BCBB1 BNC feedthroughFeedthrough typeFunctionalityrear side1 BNCtriggerR&S TS-F1U2BA1 USB 2.0 feedthroughFeedthrough typeFunctionalityside panel1 USB 2.0DUT communicationsR&S ARC-DUTH1 universal DUT holder plate for R&S ATS1500CMaximum DUT sizeMaterialThickness6Ø30 cmcolorless polycarbonate6 mmRohde & Schwarz R&S ATS1500C Antenna Test Chamber For Automotive Radar Sensors

Version 03.00, July 2020R&S AREG100A automotive radar echo generator, frontendPolarizationwith R&S AREG100A-B177Swith R&S AREG100A-B181Sfeed antennaAntenna type and gainwith R&S AREG-B177SIn-band frequency rangewith R&S AREG-B181Swith R&S AREG100A-B177Swith R&S AREG100A-B181SFor complete specifications, see R&S AREG100A data sheet (PD 3607.7057.22)RF instantaneous bandwidth76.0 GHz to 77.0 GHz76.0 GHz to 81.0 GHzlinear, vertical polarization, horizontalpolarization possible by rotating frontendmoduleWR12 rectangular horn antenna10 dBi (nom.)WR12 rectangular horn antenna10 dBi (nom.)1 GHz4 GHzOrdering informationBasic configurationDesignationAntenna test chamberAntenna test chamber3D tilt-tilt positionerCATR reflector, large sizeAlignment structure, for CATR systems inselected chambersHolder for R&S AREG100A monostaticfrontendPower filter, 230 VVentilation 1 for R&S ATS1500CVentilation 2 for R&S ATS1500CFeedthrough for R&S AREG100Amonostatic frontendEthernet feedthroughD-Sub feedthroughTypeR&S ATS1500CR&S ATS1500CR&S ARC-TTP1R&S CATR-REFL1R&S CATR-ALIC1Order 21534.2007.02R&S ARC-HARFM1536.1095.02R&S ATS-F230VR&S ARC-VENT1R&S ARC-VENT2R&S 9790.02R&S TS-F1ETRR1R&S TS-F1SD2591525.8729.021525.8835.02TypeR&S TS-F1POBB2R&S TS-F1BCBB1R&S TS-F1U2BA1R&S ARC-DUTH1Order 2Additional optionsDesignationBanana plugs feedthroughBNC feedthroughUSB 2.0 feedthroughUniversal DUT holder plate forR&S ATS1500CRohde & Schwarz R&S ATS1500C Antenna Test Chamber For Automotive Radar Sensors7

Rohde & SchwarzWorldwideLocal und personalizedCustomized and flexibleUncompromising qualityLong-term dependabilityThe Rohde & Schwarz electronics group offers innovativesolutions in the following business fields: test and measurement, broadcast and media, secure communications,cybersecurity, monitoring and network testing. Foundedmore than 80 years ago, the independent company whichis headquartered in Munich, Germany, has an extensivesales and service network with locations in more than70 countries.www.rohde-schwarz.comSustainable product design Environmental compatibility and eco-footprintEnergy efficiency and low emissionsLongevity and optimized total cost of ownershipCertified Quality ManagementISO 9001Certified Environmental ManagementISO 14001Rohde & Schwarz trainingwww.training.rohde-schwarz.comRohde & Schwarz customer supportwww.rohde-schwarz.com/support3608206522 R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KGTrade names are trademarks of the ownersPD 3608.2065.22 Version 03.00 July 2020 (sk)R&S ATS1500C Antenna Test Chamber For Automotive Radar SensorsData without tolerance limits is not binding Subject to change 2019 - 2020 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany3608.2065.22 03.00 PDP 1 enService that adds value

R&S ARC-FARFM 1537.9790.02 Ethernet feedthrough R&S TS-F1ETRR1 1525.8729.02 D-Sub feedthrough R&S TS-F1SD259 1525.8835.02 Additional options Designation Type Order No. Banana plugs feedthrough R&S TS-F1POBB2 1536.0353.02 BNC feedthrough R&S TS-F1BCBB1 1533.4070.02 R&S ATS1500C R&S

Related Documents:

numerology ıNetwork Slicing ı . ıEvolución de las tecnologias existentes y adiciones revolucionarias (cm- / mm-wave) . La Continuidad y Latencia son claves . Rohde & Schwarz 0506 07 INTERACTIVITY TEST 26 5G NR Mobile Network Testing

Rohde & Schwarz White paper Signal model based approach to joint jitter and noise decomposition 5 Additionally, we provide deep system insight through the introduction of new mea-surements, such as what-if signal reconstructions

Rohde & Schwarz White paper Power saving methods for LTE-M and NB-IoT devices 3 In the past decades, the internet has been booming and connecting people with each other. Nowadays, technology trends tell us that not only people, but also machine type devices, e.g. house equipment

Rohde & Schwarz CE Test software EMC 32 V8.53.0 NCR NCR . Radiated Emission Test . HP Amplifier HP8447E 1937A01046 2016-11-12 2017-05-13 Rohde & Schwarz EMI Test Receiver ESCI 101120 2016-12-07 2017-12-07 Sunol Sciences Bi-log Antenna JB1 A040904-2 2014-12-17 2017-12-16 TDK Chamber Chamber A 2# 2016-12-05 2019-12-05

Version 30.01, December 2021 2 Rohde & Schwarz R&S RTO Oscilloscope CONTENTS Definitions . 5

Rohde & Schwarz R&S FSC Spectrum Analyzer 3 Base unit Frequency Frequency range model .03/.13 9 kHz to 3 GHz model .06/.16 9 kHz to 6 GHz Frequency resolution 1 Hz Reference frequency, internal, nominal Aging per year 1 10 -6 Temperature drift 0 C to 30 C 1 10-6 30 C to 50 C 3 10-6

4 Rohde & Schwarz R&S FSVR Real-Time Spectrum Analyzer Specifications Operating modes signal and spectrum analyzer real-time spectrum analyzer Specifications for all operating modes Frequency Frequency range R&S FSVR7 DC-coupled 10 Hz to 7 GHz AC-coupled 1 MHz to 7 GHz R&S FSVR13 DC-coupled 10 Hz to 13.6 GHz AC-coupled 10 MHz to 13.6 GHz

MINISTRY OF COMMERCE AND INDUSTRY (Department of Industrial Policy and Promotion) NOTIFICATION New Delhi, the 11th April, 2018 G.S.R. 364(E).—This notification is being issued in supersession of Gazette Notification No. G.S.R. 501(E) dated May 23, 2017. Definitions 1. In this notification,— (a) An entity shall be considered as a Startup: i .