Concealed Ceiling Units - UK Daikin

2y ago
13 Views
2 Downloads
1.59 MB
16 Pages
Last View : 17d ago
Last Download : 3m ago
Upload by : Samir Mcswain
Transcription

Concealedceiling units

Daikin concealedceiling unitsan invisible improvement to any spaceWhy choose Daikin?Daikin is a world leader in air conditioning andheating. So no matter what your needs, you will findthe ideal solution in our wide range of products,both for heating and cooling. As an environmentallyresponsible company, all our products are designedto be highly efficient all year round with featureslike intelligent eye and weekly timer. Their low energyconsumption is also reflected in lower energy bills.Our expertise makes life easier for you too, allowingyou to control your system via a user-friendly remotecontrol. Our units are whisper quiet and, with theperfect airflow pattern, they will create your idealindoor climate. Daikin products are renowned fortheir reliability and efficiency and you can rely onservice to match.Why choose Daikinconcealed ceiling units?L-shapedFlexibility and comfort›› Daikin concealed ceiling units offer maximumflexibility and performance in rooms with limitedspace or with irregular shape (L-shaped, U-shapedor long rooms).›› Ideal for use in small and large areas: External staticpressure (ESP) is a deciding factor when choosing atype of duct.›› Flexible installation, as the air suction direction canbe altered from rear to bottom suction.›› Their automatic air flow adjustment means thatthey are draught-free and can quickly reach thetemperature you require.›› They are whisper quiet, operating at sound levelslower than 25 decibels.U-shapedLongUnobtrusive designConcealed ceiling units offer an extremelyunobtrusive solution as they are compact and onlythe discharge and intake grilles are visible.Energy efficient›› Daikin concealed units have energy efficiencyratings of up to A and a low consumption DCmotor.2A

75%ambient yWhat is an air-to-air heat pump?Complete controlDaikin heat pumps are silent and discreet, and usestate-of-the-art technology to keep energy bills aslow as possible. With a Daikin heat pump, 75% of theenergy used to heat your premises comes fromthe outside air even in cold weather, A free andinfinitely renewable resource. Only 25% is comingfrom electricity. For cooling, the system is reversed,extracting heat from the indoor air.Every system comes with user-friendly controls so thatyou can manage your internal climate and airflow.›› Individual›› Centralised›› Building management systemFlexible scheduling control adapts to differentseasons, it can monitor an entire building throughan app or connect your controls to a buildingmanagement system.Inverter control optimises efficiencyDaikin’s inverter technology is a true innovationin the field of climate control. The principle is simple:inverters adjust the power used to suit the actualrequirement. This technology provides two clearbenefits:›› Comfort: an inverter continuously regulates theheating and cooling output to adjust a room’stemperature, thus improving comfort levels. Theinverter reduces start-up time, reaching requiredroom temperature more quickly. Once reached, theinverter ensures that it is maintained.›› Energy efficient: by monitoring and adjusting theambient temperature, energy consumption dropsby 30% compared to a traditional on/off system.with inverterwithout inverter3

NEWARGUE CARDConcealed ceiling unitwith medium ESPSlim, silent and discrete solutionSlimmest unit on the market in its rangeNEW ›› With only 245mm height, ceiling voids are nochallenge any more. These units can swiftly beintegrated in narrow ceiling voidsEasy to install and to set-up›› Unique Automatic air flow adjustment functionselects the most appropriate fan curve to achievethe best comfort. With these concealed ceilingunits, over 10 fan curves can be selected to selectthe most appropriate fan curve for your application›› Bottom & rear suction allow installation both at lowdepth and low height ceiling voids›› Up to 150Pa external static pressure (ESP) to copewith most of duct & grille setupsNEWEnhanced comfortNEW ›› Sound level down to 25dBA (FBQ) comparable to abedroom at night timeEnergy efficient solutionNEW ›› Top efficiency in the market!* For FBQ50D RXS50L4A *Benefits›› Unnoticeable in operation›› Outstanding reliability›› Easy installation, even in the smallest of ceiling spaces›› Extremely efficientFBQ-D/FXSQ-A

Solution forcommercial applicationsThe solutionfor the light commercialsectorThe solution for everymedium to largecommercial applicationSky Air is Daikin’s industry-leading range for lightcommercial applications. It has been designed tooffer optimum seasonal energy efficiency. The SkyAir range offers complete comfort solutions for allkinds of commercial spaces.Daikin has over 90 years of expertise in heat pumpsand has been market leader in VRV (VariableRefrigerant Volume) systems since the companyinvented them in 1982. VRV offers you the ultimatein customised comfort, intelligent control andmaximum energy efficiency.Three complementary outdoor unitsVRV for all climate conditions and needsDepending on your requirements, you can choosebetween three complementary outdoor units,each designed to offer the ideal solution for differentsituations.Depending on where you live or the solution yourequire, you can choose between different VRVoutdoor units, each designed to offer the idealsolution for different situations.Seasonal Smart units offer you advancedtechnologies and the highest seasonal efficiencyvalues, as well as providing flexible installation andoptimum comfort in all weather conditions.Heat pumpBoth cooling and heating can be supplied by thesame unit, with 75% of the heat coming from theoutside air and only 25% from the electricity supply.Seasonal Classic units are highly efficient outdoorunits which offer an excellent combination oftechnology and comfort in commercial applicationsand can operate at temperatures as low as -15 C.Heat recoveryBoth cooling and heating can be provided by thesame unit, with only 25% coming from the electricitysupply as 75% of the heat comes from the outsideair. Heat can also be transferred from one place toanother in the same building thus reducing energycost even more!.Siesta Sky Air indoor units provide basic cooling andheating solutions for shops, offices and restaurants,leaving maximum floor space for furniture,decoration and fittings.ReplacementUpdate your older R-22 or R-407C system quickly,economically and efficiently with minimal downtime.Water cooledThe VRV IV water cooled series offers an ideal solutionfor high rise buildings using water as a heat source.Kan niet aders dan metgradient, want vloeistofwarmt op en koelt af.Kan niet aders dan metgradient, want vloeistofwarmt op en koelt af.Optimised for heatingWhere heating takes priority without compromising onefficiency, with guaranteed operation down to -25 C.Mini VRVSpace saving solution for residential and lightcommercial applications without compromising onefficiency.-5 C43 CCooling mode-25 C15.5 CHeating mode5

Indoor unitsProducts overview concealed ceiling unitsSmall concealed ceiling unitFDBQ-B / FXDQ-M9Designed for hotel bedrooms›› Compact dimensions enable installation in narrow ceiling voidsleaving only the grilles visible›› No disturbing sound to ensure a good night rest›› Flexible installation as the the air suction direction can be alteredfrom rear to bottom suctionConcealed ceiling unit with high ESPFDQ-C / FXMQ-P7ESP up to 200Pa, ideal for large sized buildings Optimum comfort guaranteed no matter the length of ductwork ortype of grilles, thanks to automatic air flow adjustment›› Discretely concealed in the ceiling: only the grilles are visible›› Flexible installation as the air suction direction can be altered fromrear to bottom suction›› Easy mounting: drain pan can be located left or right of the unitSlim concealed ceiling unitFDQ-B / FXMQ-MA9FDXS-F(9) / FXDQ-AESP up to 250Pa (FDQ-B), ESP up to 270Pa ( FXMQ-MA9),ESP up to 44Pa, slim design for flexible installation›› Discretely concealed in the ceiling: only the suction and dischargeIdeal for extra large sized spaces›› Compact dimensions enable installation in narrow ceiling voidsleaving only the grilles visiblegrilles are visible›› Up to 26.4kW (FDQ-B), up to 31.5kW (FXMQ-MA9) in heating mode›› Medium external static pressure up to 40Pa (FDXS-F), up to 44Pa(FXDQ-A)›› Small capacity unit developed for small of well insulated roomsSiesta Concealed ceiling unitABQ-CNEW Concealed ceiling unit with medium ESPFBQ-D / FXSQ-AESP up to 150Pa, optimum comfort guaranteed no matter thelength of ductwork or type of grilles›› Amongst the slimmest concealed ceiling units in the market:a height of only 245mm›› Assuring comfort at all times: flexibility to set the required fancurve manually or automatically selecting the correct fan curveA ›› Top efficiency in the market!›› 15 class unit especially developed for small or well-insulatedrooms, such as hotel bedrooms, small offices etc.›› Sound levels down to 25dB(A)›› Flexible installation, as the air suction direction can be atered fromrear to bottom suction›› Standard built-in drain pump increases flexibility and installationspeed6ESP up to 150Pa, ideal for medium sized shops with false ceilings›› Discretely concealed in the ceiling: only the grilles are visible›› Air filter ensures steady supply of clean air›› Easy installation and maintenance›› Exclusively offered for pair applications

Q-C2520-2525 6015 6335 14015 14012550 125200-250200-25071 140use of energySeasonal efficiency gives a more realistic indication on how efficient airconditioners operate over an entire heating or cooling season. Inverter technologyIn combination with inverter controlled outdoor units. Home leave operationDuring absence, the indoor temperature can be maintained at a certain level. Fan onlyThe air conditioner can be used as fan, blowing air without cooling orheating. Whisper quietDaikin indoor units are whisper quiet. Also the outdoor units areguaranteed not to disturb the quiet of the neightbourhood. changeoverAutomatically selects cooling or heating mode to achieve the settemperature. Air treatmentFXDQ-M9Air filterRemoves airborne dust particles to ensure a steady supply of clean air. HumiditycontrolFDBQ-BDry programmeAllows humidity levels to be reduced without variations in roomtemperature. AirBenefits overviewFan speed stepsAllows to select up to the given number of fan speed.22333332223Weekly timerTimer can be set to start operation anytime on a daily or weekly basis. dependingon controller Infrared remote controlInfrared remote control with LCD to start, stop and regulate the airconditioner from a ired remote controlWired remote control to start, stop and regulate the air conditioner froma ptionaloptionaloptionaloptionalCentralised controlCentralised control to start, stop and regulate several air conditionersfrom one central onaloptionaloptionaloptionalAuto-restartThe unit restarts automatically at the original settings after power failure. Self-diagnosisSimplifies maintenance by indicating system faults or operatinganomalies. Drain pump kitFacilitates condensation draining from the indoor ardMulti tenantThe indoor unit’s main power supply can be turned off when leavingthe hotel or office building. Other funtionsRemote control & timerComfortWe care iconsSeasonal efficiency - SmartAuto cooling-heatingTwin/triple/double twinapplicationMulti model applicationVRV for residentialapplicationoptional 2, 3 or 4 indoor units can be connected to only 1 outdoor unit even ifthey have different capacities. All indoor units operate within the samemode (cooling or heating) from one remote control. Up to 9 indoor units (even different capacities and up to 71 class) can beconnected to a single outdoor unit. All indoor units can individually beoperated within the same mode. optional Up to 5 indoor units (even different capacities) can be connected to asingle outdoor unit. All indoor units can individually be operated withinthe same mode. optionalstandardoptional 7

FDBQ-B / FXDQ-M9Small concealed ceiling unitDesigned for hotel applications›› Compact unit (230mm high & 652mm deep), can easily bemounted in narrow ceiling voids›› Discretely concealed in the ceiling: only the suction and dischargegrilles are visible›› Whisper quiet operation: down to 28dBA sound pressure level›› Flexible installation, as the air suction direction can be alteredfrom rear to bottom suction›› For easy mounting, the drain pan can be located to the left orright of the unitFDBQ25B / FXDQ-M9BRC1E52A/BBRC4C62 (FXDQ-M9)Fully integrated solutions for medium to large commercial environmentsIndoor unitCooling capacityHeating capacityPower input - 50HzDimensionsRequired ceiling void WeightCasingFan-Air flow rate - 50HzAir filterSound power levelSound pressure levelRefrigerantPiping connectionsPower supplyCurrent - 50HzControl systemsIndoor igh/LowType / m fuse amps (MFA)Infrared remote controlSimplified wired remote control for hotel applicationsWired remote controlUnitHeightxWidthxDepthCoolingSound power levelHeatingCoolingHigh/LowSound pressure levelHeatingHigh/LowControl systemsWired remote control(1) Contains fluorinated greenhouse ised steel7.4/5.87.4/5.8Resin net with mold resistance5037/3237/32R-410A / 2.087,56.3512.7I.D. 21.6, O.D. 27.21 /50/23016BRC4C62BRC2E52C (heat recovery type) / BRC3E52C (heat pump type)BRC1D52 / D52 / BRC1E52A/BCombination with multi outdoor units is ideal for smaller applications such as retail or residential applicationsOutdoor unit8only available in multi model application

FDXS-F(9) / FXDQ-ASlim concealed ceiling unitSlim design for flexible installation›› Compact dimensions, can easily be mounted in a ceiling void ofonly 240mmFDXS25-35F / FXDQ15-32A›› Medium external static pressure up to 40Pa (FDXS) and 44Pa(FXDQ) facilitates unit use with flexible ducts of varying lengths›› Discretely concealed in the ceiling: only the suction and dischargegrilles are visible›› 15 class unit especially developed for small or well-insulatedrooms, such as hotel bedrooms, small offices, etc. (FXDQ)BRC1E52A/BBRC4C65›› Standard drain pump with 750mm lift increases flexibility andinstallation speed (FXDQ)Fully integrated solutions for medium to large commercial environmentsIndoor unitCooling capacityHeating capacityPower input - xDepthDimensionsRequired ceiling void WeightUnitFan-Air flow rate - 50HzCoolingHigh/Nom./LowFan-External static pressure - 50HzHigh/Nom.Air filterTypeSound power levelCoolingNom.Sound pressure levelCoolingHigh/Nom./LowRefrigerantType / GWPLiquidODPiping connectionsGasODDrainPower supplyPhase/Frequency/VoltageCurrent - 50HzMaximum fuse amps (MFA)Infrared remote controlControl systemsSimplified wired remote control for hotel applicationsWired remote control(1) Contains fluorinated greenhouse 2/6.410.5/9.5/8.512.5/11.0/10.044/1530/10Removable / washable / mildew proof515233/31/2734/32/28R-410A / 2.087,59.5212.7VP20 (I.D. 20/O.D. 26)1 /50/60/220-240/22016BRC4C65BRC2E52C (heat recovery type) / BRC3E52C (heat pump type)BRC1D52 / 33/295436/34/3015.9Indoor unitDimensionsSound power d pressure 30Control systemsWired remote controlBRC1E52A/BBRC1E52A/BBRC1E52A/BOperating sound is based on the rear side suction inlet and ESP 40Pa. Operating sound for under side suction inlet: (operation sound for rear side suction inlet) 5dB. However, when installation to which the ESP becomes low is carriedout, 5dB or more may go upCombination with split outdoor units is ideal for smaller applications such as retail or residential applicationsEfficiency dataCooling capacityHeating capacityFDXS RXSkWkWkWkW25F 25L335F 35L32.403.403.204,00Nom.0.651.15Power inputNom.0.801.15Energy labelA APdesignkW2.43.40CoolingSeasonal efficiencySEER5.635.21(according to EN14825)Annual energy consumptionkWh149228Energy labelA APdesignkW2.602.90Heating (Averageclimate)SCOP4.243.88Annual energy ual energy consumptionkWh321574Nominal efficiencyEnergy labelCooling/HeatingA/AC/BEER/COP according to Eurovent 2012, for use outside EU only Nominal efficiency: cooling at 35 /27 nominal load, heating at 7 /20 nominal loadOutdoor unitDimensionsSound power levelOperation rangeRefrigerantPower Cooling/HeatingCoolingAmbientMin. Max.Min. ltageRXSmmdBA CDB CWBkgkg/TCO2EqHz/V25L335L3550x765x28559/5961/61-10 46-15 18R-410A/2,087.51/2.1R-410A/2,087.51.2/2.51 /50/220-24050F9 50L1.7/5.0/5.31.7/5.8/6.01.6501.870A 5.005.72306A4.003.931,4253.03/3.10825B/D60F -10 46-15 18R-410A/2,087.5R-410A/2,087.51.7/3.51.5/3.11 /50/220-230-240Contains fluorinated greenhouse gases9

FBQ-D / FXSQ-AConcealed ceiling unitwith medium ESPOptimum comfort guaranteed no matter thelength of ductwork or type of grilles›› Top efficiency in the market›› Automatic air flow adjustment function selects the mostappropriate fan curve to achieve the best comfort›› Compact unit can easily be mounted in a ceiling void of only285mm, leaving only suction and discharge grilles visible›› Sound levels lower than 29dBA›› Medium external static pressure up to 150Pa facilitates usingflexible ducts of varying lengths›› Flexible installation as the air suction direction can be altered fromrear to bottom suction›› Standard built-in drain pump increases the reliability of the drainsystem›› Standard plug and play connection with intelligent control systemsFBQ35-50D / FXSQ-ABRC1E52A-BBRC4C65Fully integrated solutions for medium to large commercial environmentsIndoor unitCooling capacityHeating capacityNom.Nom.CoolingNom.Power input - ghtUnitCoolingHigh/LowFan-Air flow rate - 50HzFan-External static pressure - 50Hz High/Nom.CoolingNom.Sound power levelCoolingHigh/LowSound pressure levelType / GWPRefrigerantLiquidODGasODPiping connectionsDrainPhase/Frequency/VoltagePower supplyMaximum fuse amps (MFA)Current - 50HzInfrared remote controlSimplified wired remote control for hotel applicationsControl systemsWired remote 06.392958992245x700x80028,52915/12.5/11 7 35/32/29 36/34/31 39/36/33R-410A / 2.087,5Ø 6.35 (FLARE)Ø 9.52 (FLARE)Ø 12.7 (FLARE)Ø 15.9 (FLARE)VP20 (EXTERNAL DIA. 26. INTERNAL DIA. 20), drain height 625 mm50Hz 220-240V16BRC4C65BRC2E52C (heat recovery type) / BRC3E52C (heat pump type)BRC1D52 / BRC1E52A/BContains fluorinated greenhouse gasesIndoor unitDimensionsFan - External static pressureSound power levelSound pressure oolingHigh/Medium/LowdBA35/32/2930/28/25Infrared remote controlBRC4C65Control systemsWired remote controlBRC1D527 / BRC1E52A/BEER/COP according to Eurovent 2012, for use outside EU only Nominal efficiency: cooling at 35 /27 nominal load, heating at 7 /20 nominal 06237/35/32Combination with split outdoor units is ideal for smaller applications such as retail or residential applicationsEfficiency dataCooling capacityHeating capacityFBQ RXSkWkWkWkW35D 35L33.404.00Nom.0.85Power inputNom.1.00Energy labelA PdesignkW3.40CoolingSeasonal efficiencySEER6.17(according to EN14825)Annual energy consumptionkWh193Energy labelA PdesignkW2.90Heating (Averageclimate)SCOP4.07Annual energy consumptionkWh998EER/COP3.99/4.02Annual energy consumptionkWh426Nominal efficiencyC/CEnergy labelCooling/HeatingEER/COP according to Eurovent 2012, for use outside EU only Nominal efficiency: cooling at 35 /27 nominal load, heating at 7 /20 nominal load10Nom.Nom.CoolingHeating50D 50L5.005.501.421.44A 5.006.21282A 4.404.061,5173.52/3.83710A/A60D 60L5.707.001.651.89A 6.805.84408A 6.004.012,0953.45/3.71826A/A

Outdoor unitDimensionsUnitHeightxWidthxDepthCoolingSound power levelHeatingCoolingHigh/LowSound pressure levelHeatingHigh/LowCoolingAmbientMin. Max.Operation rangeMin. requency/VoltagePower supplyContains fluorinated greenhouse gasesRXSmmdBAdBAdBAdBA CDB /45kg/TCO2EqHz/V49/4649/46-10 46-15 18R-410A/2,087.51.7/3.51 /50/220-2401.2/2.511.5/3.1Combination with Seasonal Smart ensures high quality, optimal comfort, flexible installation and highest efficiency valuesEfficiency dataCooling capacityHeating capacityPower inputFBQ RZQGNom.Nom.CoolingHeatingCoolingSeasonal efficiency(according to EN14825)Heating (Averageclimate)Nom.Nom.Energy labelPdesignSEERAnnual energy consumptionEnergy labelPdesignSCOPAnnual energy consumptionkWkWkWkWkWkWhkW71D 71L9V1100D 100L9V1125D 125L9V1140D 140L9V171D 71L8Y1100D 100L8Y1125D 125L8Y1140D 140LY16.87.501.981.91A 6.806.16386A 6.004.311,9493.433.92991C/C9.510.82.842.94A 9.505.87566A 11.304.783,3103.944.241,20612.013.53.133.52A 12.006.11687A 12,000-6.87.501.981.91A 6.806.16386A 6.004.311,9493.433.92991C/C9.510.82.842.94A 9.505.87566A 11.304.783,3103.944.241,20612.013.53.133.52A 12.006.11687A minal efficiencyAnnual energy consumptionkWhA/AEnergy labelCooling/HeatingEER/COP according to Eurovent 2012, for use outside EU only Nominal efficiency: cooling at 35 /27 nominal load, heating at 7 /20 nominal loadOutdoor unitDimensionsSound power ngNom.Sound pressure levelNight quiet modeLevel 1Min. Max.CoolingAmbientOperation rangeMin. Phase/Frequency/VoltagePower supplyContains fluorinated greenhouse gasesRZQG71L9V1mm 990x940x320dBA64dBA48dBA50dBA43 CDB CWBkg R-410A / 2.9 / x320666769505152525345-15 50-20 15.5R-410A / 4 / 2,087.58.41 5 50-20 15.5R-410A / 4 / 2,087.58.43N /50/380-415R-410A / 2.9 / 2,087.56.1140LY16952Combination with Seasonal Classic ensures good value for money for all types of light commercial applicationsEfficiency dataCooling capacityHeating capacityPower inputSeasonal efficiency(according to EN14825)FBQ RZQSGNom.Nom.CoolingHeatingCoolingNom.Nom.Energy labelPdesignSEERAnnual energy consumptionEnergy labelPdesignSCOPAnnual energy consumptionkWkWkWkWkWkWh71D 71L3V16.87.51.981.91A 6.805.84408100D 100L9V1125D 125L9V1140D 140L9V1100D 100L8Y1125D 125L8Y1140D 05A12.704.054,3903.233.631,858A 67Nominal efficiencyAnnual energy consumptionkWh9911,418C/CA/AEnergy labelCooling/HeatingEER/COP according to Eurovent 2012, for use outside EU only Nominal efficiency: cooling at 35 /27 nominal load, heating at 7 /20 nominal loadHeating (Averageclimate)Outdoor unitDimensionsSound power levelUnitCoolingCoolingSound pressure levelOperation rangeRefrigerantPower supplyHeightxWidthxDepthNom.Silent operationNom.Level 1Min. Max.AmbientMin. Max.AmbientHeatingNight quiet ltagekWRZQSGmmdBAdBAdBAdBAdBA CDB CWBkg/TCO2EqHz/V71L3V1770x900x32065494751-15.0 05354575849-15 46-15 15.5R-410A/2,087.52.9/6.11 54/8.4A9.505.57597A 354575849-15 46-15 15.5R-410A/2,087.52.9/6.13N 4/8.4Contains fluorinated greenhouse gases11

FDQ-CConcealed ceiling unit withhigh ESPESP up to 200, ideal for large sized spaces›› High external static pressure up to 200Pa facilitates using flexibleducts of varying lengths›› Automatic air flow adjustment function selects the mostappropriate fan curve to achieve the best comfort›› Reduced energy consumption thanks to specially developed DCfan motor›› Possibility to change ESP via wired remote control allowsoptimisation of the supply air volume›› Flexible installation as the air suction direction can be altered fromrear to bottom suction›› Standard built-in drain pump increases the flexibility andinstallation speed›› No optional adapter needed for DIII-connection, link your unit intothe wider building management systemIndoor unitCasingDimensionsAir filterSound power levelSound pressure levelControl atingHigh/LowInfrared remote controlWired remote controlFDQ125CBRC1E52A-B125CNot painted (galvanised)300x1,400x700White (10Y9/0.5)55x1,500x500Resin net with mold resistance6640/3340/33BRC4C65BRC1D52 / BRC1E52A/BmmmmdBAdBAdBACombination with Seasonal Smart ensures high quality, optimal comfort, flexible installation and highest efficiency valuesCombination with Seasonal Classic ensures good value for money for all types of light commercial applicationsEfficiency dataCooling capacityHeating capacityPower inputSeasonal efficiency(according to EN14825)Nom.Nom.CoolingHeatingCoolingHeating (Averageclimate)Nominal efficiencyFDQ RZQG/RZQSGkWkWkWkWNom.Nom.Energy labelPdesignSEERAnnual energy consumptionEnergy labelPdesignSCOPAnnual energy consumptionEERCOPAnnual energy consumptionEnergy labelCooling/HeatingkWkWhkWkWhkWhSeasonal Smart125C 125L9V1125C 125L8Y112.013.53.203.53A 12.005.81722.892723A 12.714.214,226.6034,2273.753.831,600A/ASeasonal Classic125C 125L9V1125C 902,728.2052,7283.213.511,870A/BEER/COP according to Eurovent 2012, for use outside EU only Nominal efficiency: cooling at 35 /27 nominal load, heating at 7 /20 nominal loadOutdoor unitDimensionsSound power levelUnitHeightxWidthxDepthCoolingCoolingNom.Sound pressure levelHeatingNom.Night quiet modeLevel 1CoolingAmbientMin. Max.Operation rangeMin. Max.HeatingAmbientType/GWPRefrigerantChargePower supplyPhase / Frequency / VoltageContains fluorinated greenhouse gases12RZQG/RZQSGmmdBAdBAdBAdBA CDB CWBkg/TCO2EqHz / V125L9V1125L8Y11,430x940x32067515345-15 50-20 15.5R-410A/2,087.54/8.41 / 50 / 220-2403N / 50 / 380-415125L9V1125L8Y1990x940x32070545849-15 46-15 15.5R-410A/2,087.52.9/6.11 / 50 / 220-2403N / 50 / 380-415

FXMQ-P7/FXMQ-MA9Concealed ceiling unit withhigh ESPIdeal for large sized spacesFXMQ-P7: ESP up to ›› Automatic air flow adjustment function measures the air volumeand static pressure and adjusts it towards the nominal air flow,whatever the length of duct, making installation easier andguaranteeing comfort. Moreover, the ESP can be changed via thewired remote control to optimize the supply air volume›› High external static pressure up to Pa facilitates using flexibleducts of varying lengths›› Discretely concealed in the ceiling: only the suction and dischargegrilles are visible›› Reduced energy consumption thanks to specially developed DCfan motor›› Flexible installation, as the air suction direction can be alteredfrom rear to bottom suction›› Standard built-in drain pump increases increases flexibility andinstallation speedFXMQ50P7BRC1E52A/BBRC4C65FXMQ-MA9: ESP up to ›› High external static pressure up to Pa facilitates using flexibleducts of varying lengths›› Discretely concealed in the ceiling: only the suction and dischargegrilles are visible›› Large capacity unit: up to . kW heating capacityFully integrated solutions for medium to large commercial environmentsIndoor unitCooling capacityHeating capacityPower input - 50HzDimensionsRequired ceiling void n /Nom./LowFan-Air flow rate - 50HzHeatingHigh/Nom./LowFan-External static pressure - 50Hz High/Nom.Air filterTypeSound power levelCoolingHigh/Nom.CoolingHigh/Nom./LowSound pressure levelHeatingHigh/Nom./LowRefrigerantType / GWPLiquidODPiping connectionsGasODDrainPower supplyPhase/Frequency/VoltageCurrent - 50HzMaximum fuse amps (MFA)Infrared remote controlSimplified wired remot

integrated in narrow ceiling voids Concealed ceiling unit with medium ESP A * For FBQ50D RXS50L * NEW NEW NEW NEW NEW Easy to install and to set-up › Unique Automatic air flow adjustment function selects the most appropriate fan curve to achieve the best comfort. With these concealed ceiling

Related Documents:

4"- CTK4ZW Concealed Fixture Trim CONCEALED FIXTURE TRIM: 48" - CTK48ZW Concealed Fixture Trim 6" - CTK6ZW Concealed Fixture Trim 72" - CTK72ZW Concealed Fixture Trim 24" - CTK24ZW Concealed Fixture Trim 96" - CTK96ZW Concealed Fixture Trim 2.6.1 General The edge details on the Optima and Lyra Concealed product are

Daikin Ceiling Concealed Horizontal Fan Coil Unit. FWW-C/F/H FWW-DA FWW-AA FUW-A WIRIN INTALLATION 5 NRAL FWW-VC GENERAL FWW-VC Technical Specifications Ceiling Concealed Unit FWW-VC (AC) Standard Unit/2-pipe/3 Rows MODEL FWW200VC FWW300VC FWW400VC

Daikin Introduction Course Objectives Daikin introduction and history Daikin as the global leader recognized for energy efficiency, innovation, and high quality products and services Daikin and the environment Target Audience Recommended for anyone Duration 0.5 Hours Class

Ceiling Cassette Ceiling Convertible Fan Coil Unit Product Catalogue Ducted . Ceiling Convertible Type Ceiling Concealed Type Ducted Blower Type 20 24 Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. . The unit

Concealed ceiling type fancoil dimensions COOLING CAPACITY MODEL NAME A (mm) B (mm) C (mm) D (mm) E (mm) Concealed Ceiling Type Fan Coil 2 Piped 2 kw ARGT02T-L/R 697 499 235 475 158 3.5 kw ARGT03T-L/R 910 499 235 665 158 4.5 kw ARGT04T-L/R 910 499 235 965 158 5.4 kw ARGT05T-L/

CDX edge tile is a fully concealed system that provides an elegant, seamless ceiling. Rockfon SCD edge tile is a semi-concealed system that provides a more monolithic-looking ceiling than traditional reveal tiles, leaving a 1/4" reveal between tiles. Both systems provide 100% downward accessibility (unless penetrations exist). Rockfon

Montana State University . isaac.swensen@montana.edu . Abstract . Despite persistent debate on the role of concealed-carry legislation, decisions to legally carry concealed handguns are not well understood. Using detailed data on concealed-carry permit applications, we explore whether individuals apply for concealed-carry permits in response to .

API Recommended Practice 500, Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class 1, Division 1 and Division 2 API Recommended Practice 505, Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class 1, Zone 0, Zone 1 and Zone 2 ASSE Z359.1, The Fall Protection Code ASTM F2413, Standard Specification for .