Wall Mounted Ceiling Cassette Ceiling Convertible Ducted .

2y ago
24 Views
2 Downloads
1.94 MB
17 Pages
Last View : 14d ago
Last Download : 3m ago
Upload by : Maxine Vice
Transcription

PCXF14Chilled WaterPRODUCT SYSTEMWall MountedCeiling CassetteCeiling ConvertibleDuctedFan Coil UnitProduct CatalogueProducts manufactured in an ISO certified facility.This document contains the most current product information as of this printing.@2014-1

Products OverviewContentskWCooling Capacity0FWW-LWall Mounted TypeFWF-C02Ceiling Cassette Type05* With Brushless DC /55 / 6 / 8 / 9 / 11 / 1312Ceiling Convertible Type16FWE-EFWC-C5 / 6 / 7 / 8 / 10 / 123 / 4 / 6 / 7 / 9 / 11 / 12 / 14 / 16Ceiling Concealed TypeFUD-B20Ducted Blower Type24Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly.All specifications are subjected to change by the manufacturer without prior notice.20 / 25 / 30 / 403540

Wall Mounted TypeComfortble Air Flow & Lower Sound LevelUser given more choice on preferable fan speed, quiet mode orautomatic setting. With the introduction of SCR indoor fan motor, astep-less change of fan speed results in smooth air flow andunnoticeable sound level change during fan speed change.Easy MaintenanceAir intake grill is easily detachable to be cleaned with water.Sleep function for Cool and Heat modeOnce activated, set temperature will be increased / decreasedgradually according to normal sleeping temperature patterns toensure a comfortable sleeping environment.FWW-LWireless Remote ControllerBRC52AWired Remote ControllerBRC51A (Option)Sleep Set On1/212HoursTemperature0-1 CHeating-2 ClingCooHeating mode*Stylish Flat-PanelIdeal blend of style and function. The front panel is designed for contemporary style withoutcompromising on function. Air intake area is designed to ensure smooth air flow profile forbetter sound quality and optimized volume.Indoor Quiet ModeMore quiet room environment. With up to five selectable fan speeds, users are given morechoices. By selecting Quiet mode, the sound pressure level isreduced down to an unobstrusive 24 dBA. To quickly cool down the room, Turbo model can be selected formaximum cooling power and highest airflow. 0.5 C0Sleep 1/2Set On 1 C 0.5 C12Cooling moders› NIM-Able› Sleep Function For Cool And Heat Mode› Auto Restart With Last-State-Memory› Valve & Valveless Control Options› Self Diagnosis Features› Compact & Easy To Use Wireless Remote ControllerHou› Comfortable Air Flow & Lower Sound Level› Stylish Flat-Panel› Indoor Quiet Mode› Turbo Mode› Uniform Air Distribution› Easy MaintenanceTemperature-3 CAuto Restart with Last-State-MemoryIn case of sudden power failure during operation, unit restartsautomatically & unit will operate based on previous setting whenpower is resumed.Power FailurePower ReturnsOperationStopRestart24dBA Is So Quiet You Can Even Hear WhispersE2 PROM20RustlingOf Leaves30Pendulum OfA Wall Clock24dBAforFWWM-L40Library50Normal Office(dB)Setting stored before power failure.SLLMHTurboCompact & Easy To Use Wireless Remote ControllerFanSpeedHighLowTurbo ModeTURBO function is available in COOL and HEAT modes only. Once itis activated, the air-conditioner will run into full power with indoor fanrunning at MAX speed for 20 minutes. This enables the settemperature to be achieved faster. If TURBO and SLEEP are activatedat the same time, the SLEEP mode timer will be reset, it will resumeafter TURBO function is cleared.Compact and user friendly wireless remote controller BRC52A offers: Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer SettingT roomWireless Remote ControllerBRC52AT setStart20min30minUniform Air Distribution2Wired Remote ControllerBRC51A (Option)Automated air swing ensures conditioned air distributed evenly.Self Diagnosis FeaturesThis feature helps to detect any faults or malfuctioning in the systemand provide user a warning by blinking of the LED lights.3

Ceiling Cassette Compact Type (600x600)Specification for Wall Mounted Type 50HZMODELNOMINAL COOLING CAPACITYNOMINAL SENSIBLE COOLING CAPACITYNOMINAL HEATING CAPACITY(ENTERING WATER TEMP. 50 0500250007330W3220352044006010NOMINAL TOTAL INPUT POWERW3132425772NOMINAL RUNNING CURRENTA0.200.200.210.300.34220-240 / 1 / 50V/Ph/HzPOWER SOURCEREFRIGERANT TYPECONTROLN/AAIR DISCHARGEOPERATIONLCD WIRELESS MICRO-COMPUTER REMOTE CONTROLCFMHIGHAIR 2.513.434.01litres/min7.007.689.5013.0015.18HEAD LOSS (COOLING)kPa34.024.031.030.036.0HEAD LOSS (HEATING) : 50 CkPa29.020.025.027.033.0MAX. WORKING PRESSUREkPaNOMINAL WATER FLOW RATEm/s0.680.740.970.831.01SOUND PRESSURE LEVEL (H/M/L/Q)dBA34 / 29 / 25 / 2435 / 30 / 25 / 2442 / 39 / 32 / 2942 / 38 / 34 / 3246 / 42 / 39 / 37UNIT DIMENSIONHXWXDmm288 X 800 X 206310 X 1065 X 224PACKING DIMENSIONHXWXDmm344 x 874 x 274386 X 1136 X 314kg9CONDENSATE DRAIN SIZEmmPIPE CONNECTIONmmINDOOR UNIT14DIRECTFAN 09201070LOWRPM760780955825970TYPEINDUCTIONINDEX OF PROTECTION (IP)IP20INSULATION GRADERATEDINPUT 1STARTING CURRENTA0.400.400.400.300.43MOTOR IALDIAMETER7.00mmMATERIALFINALUMINIUMFACE AREAm²0.180.18ROW0.182WATER VOLUMEAIR QUALITY FILTER› Branch Duct Connection› Sleep Function For Cool & Heat Mode› Auto Restart With Last-State-Memory› NIM-Able› Self Diagnosis Features› Choices Of Wired Or Withless Remote Controller12.70DRIVECOIL› Compact Design› Fresh Air Intake› Stylish & Slim Panel› Built In High Head Drain Oump & Water Flow Switch› 4 Way Air Discharge & Air Swing› Valve Or Valveless Control OptionsCROSS FLOW FANFANTUBEFWF-C19.05TYPEFAN MOTORWired Remote ControllerBRC51A1608SURFACE AIR VELOCITYUNIT WEIGHTlitre0.520.58TYPE0.58WASHABLE SARANET FILTERpc2COLOURWHITEQUANTITYCASING4Wireless Remote ControllerBRC52AAUTOMATIC LOUVER (UP & DOWN)MODEENTERING AIR TEMPERATURECOOLING27 C DB / 19 C WBENTERING WATER TEMPERATURE7 CLEAVING WATER TEMPERATURE12 CHEATING20 C DB50 C (2 Pipes System)70 C (4 Pipes System)45 C (2 Pipes System)60 C (4 Pipes System)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.5

Compact DesignBranch Duct ConnectionCeiling Cassette C Series body dimension is only 570 mm x 570 mmwhich can easily fits into a 600 mm ceiling grid.Improves air flow distribution when there is an obstruction. It allowsfor air conditioning of two rooms simultaneously.Specification for Ceiling Cassette Compact Type 50HzNOMINAL COOLING CAPACITYBranch duct chamberDischarge ductNOMINAL SENSIBLE COOLING CAPACITY600mmWall600mmRoom 1570mmNOMINAL HEATING CAPACITY(ENTERING WATER TEMP. 50 C)Room 2570mmOnce activated, set temperature will be increased / decreasedgradually according to normal sleeping temperature patterns toensure a comfortable sleeping environment.0Sleep 1/2Set On-2 C-3 CDuct flange (With insulation material)The slim panel can be blended easily into decoration and interior design.The unit comes with a 700 mm built-in high head drain pump. Asafety float is incorporated int he drain pump to monitor its water level.OperationCONTROLN/AAIR DISCHARGE4 WAY AUTOMATIC LOUVER (UP & DOWN)OPERATIONLCD WIRELESS MICRO-COMPUTER REMOTE 220280USGPM2.033.433.577.6812.9813.51HEAD LOSS (COOLING)kPa19.326.928.8HEAD LOSS (HEATING) : 50 CkPa16.823.926.5MAX. WORKING PRESSUREkPam/s0.750.760.83SOUND PRESSURE LEVEL (H/M/L)dBA42 / 35 / 2945 / 38 / 3048 / 40 / 36UNIT DIMENSION - ( ) WITH PANELHXWXDmm250 X 570 X 570 (295 X 640 X 640)PACKING DIMENSION - ( ) PANELHXWXDmm316 X 630 X 630 (126 X 700 X 726)Choices Of Wired Or Wireless Remote ControllerIt comes with 4 way air discharge and air swing function to ensurebetter air distribution and circulation in the room.Compact and user friendly wireless BRC52A and wired BRC51Aremote controller offer : Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer SettingkgCONDENSATE DRAIN SIZEmmPIPE CONNECTIONmm6Wireless Remote ControllerBRC52AWired Remote ControllerBRC51A19.05DIRECTFAN 0610TYPEINDUCTIONINDEX OF PROTECTION (IP)IP20BINSULATION GRADERATEDINPUT POWERFAN .240.31STARTING CURRENTLOWA0.320.300.47MOTOR 0ALUMINIUMMATERIALFINm²FACE AREA0.240.251220.430.830.83ROWlitreWATER VOLUMEFILTER0.25WASHABLE SARANET FILTERTYPEQUANTITYCASINGThe design is flexible enough to allow for either valve or valvelesscontrol installation.17 319.05DRIVECOIL17 3TURBO FANFANAIR QUALITYValve Or Valveless Control Options15 3TYPESetting stored before power failure.4 Way Air Discharge & Air Swing1608SURFACE AIR VELOCITYRestartE PROM220-240 / 1 / 50litres/min2700mmV/Ph/HzUNIT WEIGHT (UNIT PANEL)Stop5280REFRIGERANT TYPE1Power Returns33701800079Auto Restart With Last-State-MemoryPower Failure2930160000.35This feature helps to detect any faults or malfuctioning in the systemand provide user a warning by blinking of the LED lights.Built In High Head Drain Pump & Water Flow Switch1910120000.28NOMINAL WATER FLOW RATEIn case of sudden power failure during operation, unit restarts automatically& unit will operate based on previous setting when power is resumed.WBtu/h0.28INDOOR UNITStylish & Slim Panel11500ASelf Diagnosis FeaturesIntake duct (Field supplied and installed)10000NOMINAL RUNNING CURRENTCooling modeHeating mode*650064 1 C24540Btu/h4690HoursHoHea410063ling-1 Cting24903520Coo 0.5 C15500WWAIR FLOW 0.5 CFWF05C14000W2ursTemperature Knock out hole is available at the unit. Installation & accessories need to be field supplied & installed. Keep the introduction of fresh air intake within 20% of the totalair flow. Also provide a chamber and use a booster fan.Sleep Set On1/21Temperature0Fresh Air IntakeFWF04C8500NOMINAL TOTAL INPUT POWERPOWER SOURCESleep Function For Cool And Heat ModeFWF02CBtu/hMODELMODEENTERING AIR TEMPERATURECOOLING27 C DB / 19 C WBENTERING WATER TEMPERATURE7 CLEAVING WATER TEMPERATURE12 Cpc1COLOURLIGHT GREYHEATING20 C DB50 C (2 Pipes System)70 C (4 Pipes System)45 C (2 Pipes System)60 C (4 Pipes System)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.7

Ceiling Cassette Type (900x900)Multi Comfort - 3 Air Swing Pattern ControlOptimum Air DischargeTo increase the comfort level of the air conditioned area of FWK-Eseries, the system had been built in with three different type of airflow pattern to suit different requirement.* The default setting is pattern 1. The air swing pattern can beselected via wireless remonote control.Combining 4 ways air discharge and large discharge area on eachside, Ceiling Cassette promote even air distribution. The additionalfeature of automatic air swing helps to distribute the conditioned airmore evenly to every corner of the room.Standard SettingLouver is set to swing at the maximum angle for gentle drafts.Wireless Remote ControllerBRC52AWired Remote ControllerBRC51A› Multi Comfort - 3 Air Swing Pattern Control› Fresh Air Intake› Optimum Air Discharge› Superior Sound Level› Branch Duct Connection› Low Height Design› Built In High Head Drain Pump & Water Flow Switch› Modern & Elegant Panel10 10 FWK-E65 › Low water Pressure Drop› Self Diagnosis Features› NIM-Able› Valve Or Valveless Control Options› Sleep Function For Cool & Heat Mode› Auto Restart With Last-State-Memory› Choices Of Wired Or Wireless Remote ControllerPattern 165 Superior Sound LevelDraft Prevention SettingWith the aid of Coanda effect, direct draft which may lead todiscomfort can be avoided.With the adapted technology from Daikin turbo fan, CeilingCassette series is able to achieve exceptional low noise.With up to 4 selected fan speeds, users are given more choices.By selecting the Quiet mode, the sound pressure level can be aslow as 23dBA.Longitudinal vorticesgenerated along serrationedges accelerate mixingturbulence which reducesvortex shedding noise.10 10 40 Pattern 240 Soil Prevention SettingEven distribution of cooling whilst ensuring ceiling to bekept spotless.30 Pattern 3Improves air flow distribution when there is an obstruction. It allowsfor air conditioning of two rooms simultaneously.Branch duct chamber30 Discharge duct65 Wall65 Branch Duct ConnectionFresh Air Intake Knock out hole is available at the unit. Installation & accessories need to be field supplied & installed. Keep the introduction of fresh air intake within 20% of the totalair flow. Also provide a chamber and use a booster fan.Duct flange (With insulation material)Room 1Room 2Low Height DesignUnit height as low as 265mm for installation convenience.265mm 350mmIntake duct (Field supplied and installed)89

Once activated, set temperature will be increased / decreasedgradually according to normal sleeping temperature patterns toensure a comfortable sleeping environment.NOMINAL COOLING CAPACITY2HoursTemperatureNOMINAL HEATING CAPACITY(ENTERING WATER TEMP. 50 038300455005200015240W821098501123013340NOMINAL TOTAL INPUT POWERW95126167186227NOMINAL RUNNING CURRENTA0.440.550.740.851.03220-240 / 1 / 50V/Ph/HzPOWER SOURCEREFRIGERANT TYPEting-2 CCONTROL-3 CHeating mode*AIR FLOWolingCoN/AAIR DISCHARGE4 WAY AUTOMATIC LOUVER (UP & DOWN)OPERATIONLCD WIRELESS MICRO-COMPUTER REMOTE 31.9436.29HEAD LOSS (COOLING)kPa2037224453HEAD LOSS (HEATING) : 50 CkPa1933193847MAX. WORKING PRESSUREkPaNOMINAL WATER FLOW RATETemperatureIt is designed with unique "round" side contour and new LED lightlocation. The rotateable intake grill promotes uniform installationas well.Sleep Set On1/21-1 CHeaModern & Elegant PanelMODELNOMINAL SENSIBLE COOLING CAPACITY0700mmSpecification for Ceiling Cassette Type 50Hz 0.5 C 0.5 C0Sleep 1/2Set On 1 C12Cooling modersThe unit comes with a 700mm built-in high head drain pump. Asafety float is incorporated int he drain pump to monitor itswater level.Sleep Function For Cool And Heat ModeHouBuilt In High Head Drain Pump &Water Flow SwitchSURFACE AIR VELOCITYm/s0.911.041.141.031.17SOUND PRESSURE LEVEL /43/3352/49/45/39UNIT DIMENSION - ( ) WITH PANEL H X W X Dmm265 X 820 X 820 (340 X 990 X 990)300 X 820 X 820 (375 X 990 X 990)HXWXDmm341 X 916 X 916 (125 X 1020 X 1020)376 X 916 X 916 (125 X 1020 X 1020)PACKING DIMENSION - ( ) PANELUNIT WEIGHT (UNIT PANEL)Auto Restart With Last-State-MemoryPower FailurePower ReturnsOperationStopRestartkgCONDENSATE DRAIN SIZEmmPIPE CONNECTIONmm26 426 4DIRECTFAN 0LOWRPM360400450510610INDUCTIONTYPEIP20INDEX OF PROTECTION (IP)BINSULATION 50.490.710.82LOWA0.360.390.390.570.69STARTING CURRENTA0.440.710.891.021.28MOTOR OUTPUTW304565801100.46RATEDINPUT POWERFAN MOTORRATEDRUNNINGCURRENTSetting stored before power failure.Low Water Pressure DropAlso commonly known as low head loss actually helps to increasethe system efficiency.Self Diagnosis FeaturesThis feature helps to detect any faults or malfuctioning in the systemand provide user a warning by blinking of the LED lights.Choices Of Wired Or Wireless Remote ControllerCompact and user friendly wireless BRC52A and wired BRC51Aremote controller offer : Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer SettingValve Or Valveless Control Options8MATERIALWireless Remote ControllerBRC52AWired Remote MINIUMm²FACE AREAROWWATER 35TYPEWASHABLE SARANET FILTERQUANTITYCASINGNIM-Able10TUBEAIR QUALITY FILTERThe design is flexible enough to allow for either valve or valvelesscontrol installation.Able to communicate with the versatile NIM networking controlmodule and offers the oppurtunity of one centralized control for asystem of multiple indoor units in a building.POLESCOIL32 419.05DRIVE232 4TURBO FANFANE PROM28 419.05TYPEINDOOR UNITIn case of sudden power failure during operation, unit restarts automatically& unit will operate based on previous setting when power is resumed.1600pc1COLOURLIGHT GREYMODEENTERING AIR TEMPERATURECOOLING27 C DB / 19 C WBENTERING WATER TEMPERATURE7 CLEAVING WATER TEMPERATURE12 CHEATING20 C DB50 C (2 Pipes System)70 C (4 Pipes System)45 C (2 Pipes System)60 C (4 Pipes System)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.11

Energy SavingCompared to the traditional AC motor, DC motor offers theadvantages of lower power input , higher efficiency and hence moreenergy saving. Brushless DC motor has less internal resistance and better heatdissipation in the stator coils. As a result, it has higher operatingefficiencies since heat can more efficiently dissipate via thestationary motor housing. With the green building and development being so welcomednow, this Ceiling Casstte type with Brushless DC motor gives youanother excellent option to consider.Wireless Remote ControllerBRC52AWired Remote ControllerBRC51A› Branch Duct Connection› Low Height Design› Built In High Head Drain Pump & Water Flow Switch› Superior Sound Level› Fresh Air Intake› Low Water Pressure Drop› Sleep Function For Cool And Heat Mode› Choices Of Wired Or Withless Remote Controller15050600Brushless DC motor does not use carbon brushes or a mechanicalcommutator, thus, it is low maintenance and non-sparking.4 Pipe System Available*Modulating Fan Speed Control1000Low Maintenance & No Brush Sparking* FWKE-EH model200Power Input (W)› Comfortable› Energy Saving› Low Noise› Low Maintenance & No Brush Sparking› 4 Pipe System Available*› Modulating Fan Speed Control› Optimum Air Discharge› Multi Comfort - 3 Air Swing Pattern ControlDue to no brushes or a mechnical commutator,it has less shaft friction or inertia and henceless audible noise as low as 16 dBA.4 pipe system allows a distribution system that contains both hotwater supply with return lines and a chilled water supply withreturn lines.Power Consumption Comparison BetweenAC Motor & DC MotorFWKE-ELow Noise650700750800850900950100010501100Air Flow (CFM)AC MotorFan speed modulates steplessly based on room temperature toreduce the difference between room temperature and settemperature and hence provides maximum comfort and reducesenergy consumption.* Available in auto fan modeDC Brushless MotorEnergy Saving Maximum67%Recommended ApplicationsCeiling Cassette type fan coil with Brushless DC motor provides agreen and pleasant environment.Room Temperature v.s. CFMRoom TemperatureCeiling Cassette Type (900x900) With Brushless DC MotorCFMOfficeHome12Restaurant13

Specification for Ceiling Cassette Type 50HZ (4 Pipe System)Specification for Ceiling Cassette Type 50Hz (2 Pipe System)FWKE05EMODELQUIETNOMINAL COOLING CAPACITYNOMINAL SENSIBLE COOLING CAPACITYNOMINAL HEATING CAPACITY(ENTERING WATER TEMP. 50 C)NOMINAL RUNNING CURRENTPOWER SOURCEFWKE08EMEDIUM HIGHQUIETLOW8200119001590020100 1520019800247003000021000 26800 07850Btu/h580087001170015400 1100014500185002190014600 18900 08370554011300 152001980024200 1840023900304003820024100 31600 0.260.190.280.430.740.210.350.550.95220-240 / 1 / 234.06kPa510152479142015223041HEAD LOSS (HEATING) : 50 CkPa48132158121812202637MAX. WORKING PRESSUREkPaHEAD LOSS 570.710.83SOUND PRESSURE LEVELdBA162331373137424734414651UNIT DIMENSION - ( ) WITH PANEL H X W X Dmm265 X 820 X 820 (340 X 990 X 990)300 X 820 X 820 (375 X 990 X 990)PACKING DIMENSION - ( ) PANEL H X W X Dmm341 X 916 X 916 (125 X 1020 X 1020)kgCONDENSATE DRAIN SIZE26 4mmPIPE CONNECTIONRPMFAN SPEED200280360450350INDEX OF PROTECTION (IP)0.11COILAIRQUALITY0.430.7413550 983120NOMINAL RUNNING 550.958701060POWER SOURCE220-240 / 1 / 50V/Ph/HzN/A4 WAY AUTOMATIC LOUVER (UP & DOWN)AIR DISCHARGEOPERATIONLCD WIRELESS MICRO-COMPUTER REMOTE CONTROLAIR FLOWCFMEXTERNAL STATIC PRESSURE (H/M/L)220350470620420560720NOMINAL WATER FLOW RATE (HEATING)890510680N/APaNOMINAL WATER FLOW RATE EAD LOSS (COOLING)kPa591318610151912192432HEAD LOSS (HEATING) : 50 CkPa71017221318253221303952MAX. WORKING PRESSUREkPa16080.710.83414651376 X 916 X 916 (125 X 1020 X 1020)UNIT DIMENSION - ( ) WITH PANEL H X W X Dmm32 4PACKING DIMENSION - ( ) PANEL H X W X 300 X 820 X 820 (375 X 990 X 990)341 X 916 X 916 (125 X 1020 X 1020)376 X 916 X 916 (125 X 1020 X 1020)28 426 4kg19.05TURBO FANDIRECTFAN SPEEDRPM200280360450350INDEX OF PROTECTION (IP)FANMOTOR4005100.550.95IP20EAA1.52.22.2MOTOR OUTPUTW70701008880.110.130.190.260.19DIAMETERFACE re31.361.972.350.46WASHABLE SARANET 750ESTARTING CURRENTFIN630IP20RATED RUNNING CURRENTWATER VOLUMECASING660EROWLIGHY GREY550IP20INSULATION GRADEPOLESCOIL440BLDCTYPE0.9532 419.05DRIVETUBE0.39265 X 820 X 820 (340 X 990 X 990)TYPEFANCOLOUR12 C71706350AIRQUALITYLEAVING WATER TEMPERATURE606046200 534001217 C49003910050507.00WASHABLE SARANET FILTERENTERING WATER TEMPERATURE3890319007pcCOOLING27 C DB / 19 C WB5750382000.57ALUMINUMMODEENTERING AIR TEMPERATURE4850328003750COPPERNOTE:A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:FWKE05E MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNITFWKE08/11E MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE 1560128000.6870ROWWBtu/h37WWATER VOLUME0.2890000.55MOTOR OUTPUTm²775020700 24500312.2FACE 96000.64Amm61001660031STARTING AL4400131000.42RATED RUNNING CURRENTPOLES360010200mm660HIGH26400 00dBAIP200.1317100SOUND PRESSURE LEVELIP20INSULATION GRADE13300WBLDCTYPE15000123002800PIPE CONNECTION5509600760019.05440LOW MEDIUM68002000mmDIRECTQUIET5300CONDENSATE DRAIN SIZEDRIVEHIGHWUNIT WEIGHTTURBO FANLOW MEDIUMBtu/h19.05TYPEQUIETSURFACE AIR VELOCITY28 4mmHIGHW1608SURFACE AIR VELOCITYUNIT WEIGHTLOW MEDIUM(ENTERING WATER TEMP. 50 C)N/APaFWKE11EHFWKE08EHQUIETFAN INPUT POWERCONTROLUSGPMFANMOTORNOMINAL HEATING CAPACITYINDOOR UNITCFMNOMINAL WATER FLOW RATEFANNOMINAL SENSIBLE COOLING CAPACITYLCD WIRELESS MICRO-COMPUTER REMOTE CONTROLOPERATIONBtu/hNOMINAL COOLING CAPACITY4 WAY AUTOMATIC LOUVER (UP & DOWN)AIR DISCHARGEFWKE05EHMODELREFRIGERANT TYPEN/AEXTERNAL STATIC PRESSURE (H/M/L)INDOOR UNITLOW MEDIUM HIGH2400V/Ph/HzAIR FLOWpc1COLOURLIGHY GREYNOTE:A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:FWKE05EH MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNITFWKE08/11EH MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNITHEATING20 C DB50 C (2 Pipes System)70 C (4 Pipes System)45 C (2 Pipes System)60 C (4 Pipes System)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.14QUIETWREFRIGERANT TYPECONTROLFWKE11EMEDIUM HIGHBtu/hBtu/hFAN INPUT POWERLOWMODEENTERING AIR TEMPERATURECOOLING27 C DB / 19 C WBENTERING WATER TEMPERATURE7 CLEAVING WATER TEMPERATURE12 CHEATING20 C DB50 C (2 Pipes System)70 C (4 Pipes System)45 C (2 Pipes System)60 C (4 Pipes System)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.15

Ceiling Convertible TypeCompact DesignCeiling and Floor Installating OptionUnit height as low as 212mm for installation at limited ceiling space.The unit is uniquely designed with possiblity to be installed under orsitting on the floor to suit any interior design requirements.1090mm630mm212mmFWE-EWireless Remote ControllerBRC52AWired Remote ControllerBRC51AFar Air Throw› Compact Design› Far Air Throw› Auto Air Swing› Service & Maintenance At Ease› Ceiling & Floor Installing Option› Versatile Installation› Room Temperature Sensing› Saranet Filter› Sleep Function For Cool And Heat Mode› Auto Restart With Last-State-Memory› Valve Or Valveless Control Options› Self Diagnosis Features› NIM-Able› Choices Of Wired Or Wireless Remote Controller*Wall bracket is supplied as optional item.Maximum air throw distance up to 16.5m.Auto Air SwingThe motorized louver enables the air flow to be evenly distributed.Versatile InstallationThe unit is designed to work with high pressure head drain pump(optional). Thus offering flexibility for installation on condensate drainpipe. The drain pump comes with a high head and is incorporatewith the float switch as safery protection.* Drain pump kit supplied as optional item700mmService & Maintenance at EaseThe washable fitler can be easily accessed by just pulling down theintake grill.During servicing or repairing, only the bottom panel needs to beremoved in order to access the parts like fan motor, blower, wiringconnection, control box, piping connection and so on.Room Temperature SensingAble to sense the room temperature in order to perform morecontrols for comfort.Saranet Air FilterThe anti fungus air filter removes air-particles from the air.1617

NOMINAL COOLING CAPACITY-1 CingNOMINAL TOTAL INPUT POWERNIM-AbleNOMINAL RUNNING CURRENTAble to communicate with the versatile NIM networking controlmodule and offers the oppurtunity of one centralized control for asystem of multiple indoor units in a building.CONTROLling 0.5 C12Cooling 13A0.460.490.52N/AAUTOMATIC LOUVER (UP & DOWN)OPERATIONLCD WIRELESS MICRO-COMPUTERREMOTE 490520USGPM3.434.494.67Litres/min131717.68HEAD LOSS (COOLING)kPa27.448.157.1HEAD LOSS (HEATING) : 50 ⁰CkPa24.242.150.2MAX. WORKING PRESSUREkPa1608SURFACE AIR VELOCITYm/s0.871.011.08SOUND PRESSURE LEVEL (H/M/L)dBA50 / 43 / 4153 / 51 / 4956 / 51 / 44UNIT DIMENSIONHXWXDmm212 X 1090 X 630PACKING DIMENSIONHXWXDmm297 X 1197 X 740UNIT WEIGHTkg27CONDENSATE DRAIN SIZEmm19.05PIPE CONNECTIONmm12.7TYPEBLOWERDRIVEIn case of sudden power failure during operation, unit restartsautomatically & unit will operate based on previous setting whenpower is resumed.Power FailureOperationFAN 1431200INDUCTIONINDEX OF PROTECTION (IP)IP 22INSULATION TARTING CURRENTA5.210.324MOTOR OUTPUTW506570FAN MOTORRestartRATED RUNNING CURRENT2E PROMPOLESTUBESetting stored before power failure.HIGHTYPERATED INPUT POWERPower ReturnsStopWired Remote ControllerBRC51A62DIRECTFANINDOOR UNITAuto Restart with Last-State-MemoryWireless Remote ATERIALFINALUMINUMFACE AREAm²0.27Litre1.11ROW3WATER VOLUMEAIR QUALITYCOMING SOON220-240 / 1 / 50AIR DISCHARGENOMINAL WATER FLOW RATEHours0Sleep 1/2Set On 1 C 0.5 CAIR FLOWCompact and user friendly wireless BRC52A and wired BRC51Aremote controller offer : Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer SettingCooFWE10E24800REFRIGERANT TYPEChoices Of Wired Or Wireless Remote Controller-3 CHeating mode*FWE08E21000V/Ph/HzPOWER SOURCE-2 CtHeaTemperatureNOMINAL HEATING CAPACITY(ENTERING WATER TEMP. 50 ⁰C)FWE07E20300N2NOMINAL SENSIBLE COOLING CAPACITYFWE06E15500OSleep Set On1/21HoursTemperatureThis feature helps to detect any faults or malfuctioning in the systemand provide user a warning by blinking of the LED lights.FWE05EBtu/hSOSelf Diagnosis Features0MODELGThe design is flexible enough to allow for either valve or valvelesscontrol installation.FILTERINOnce activated, set temperature will be increased / decreasedgradually according to normal sleeping temperature patterns toensure a comfortable sleeping environment.Specification for Ceiling Convertible Type 50HzMValve Or Valveless Control OptionsCOSleep Function For Cool And Heat ModeTYPEWASHABLE SARANET FILTERQUANTITYCASINGpc2COLOURWHITENOTE:A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPMODEENTERING AIR TEMPERATURE18COOLING27 C DB / 19 C WBENTERING WATER TEMPERATURE7 CLEAVING WATER TEMPERATURE12 CHEATING20 C DB50 C (2 Pipes System)70 C (4 Pipes System)45 C (2 Pipes System)60 C (4 Pipes System)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.19

Ceiling Concealed TypeExcellent Air Distributio

Ceiling Cassette Ceiling Convertible Fan Coil Unit Product Catalogue Ducted . Ceiling Convertible Type Ceiling Concealed Type Ducted Blower Type 20 24 Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. . The unit

Related Documents:

Midea V6 14.0 k 1 Indoor and Outdoor Unit Capacities 1.1 Indoor Units 1.1.1 Standard indoor units Table 1-1.1: Standard indoor unit abbreviation codes Abbreviation code Type Q2 Abbreviation code Type Q1 One-way Cassette T1 High Static Pressure Duct Two -way Cassette G Wall mounted Q4C Compact Four-way Cassette DL Ceiling & Floor

7. Place ceiling panel #8 into position and lock it to ceiling panel #7 first, then to the wall panels, leaving the wall-to-ceiling panel camlocks nearest the exposed ceiling panel seam on either side of ceiling panel #8 unlocked. Lock the two wall-to-ceiling panel camlocks left unlocked in step 4 to panel #7.

4-Way Ceiling Mounted Cassette Unit (2’ 2’) Notes: 1 Nominal cooling capacities are based on the following conditions: . Standard Accessories Installation and Operation manual, Paper pattern for installation, Drain hose, Clamp metal, Washer fixing plate, Sealing pads,

The Great Wall of China is beautiful.There is no one who can climb the great wall all the way because when they climb the great wall to high they will feel sick.File Size: 608KBPage Count: 25Explore further[PDF] The Great Wall of China Semantic Scholarwww.semanticscholar.orgGreat Wall of China - HISTORYwww.history.comGreat Wall of China: Length, History, Map, Why & When Built Itwww.chinahighlights.comGreat Wall Of China, History, Facts, Culture & More .sublimechina.comA History of the Great Wall of Chinawww.worldscientific.comRecommended to you based on what's popular Feedback

Wall Duct can be installed in non load-bearing applications surface mounted on the wall or flush mounted in the wall. It is typically installed on walls, above the ceiling, or surface mounted on the . wireway into a junction box Construction 14 Gauge A36 Galvanized steel

ARMSTRONG Armstrong Ceiling Tile OPTRA - Armstrong Ceiling Tiles Beaty Sky -Armstrong Ceiling Tiles Dune Square Lay-In and Tegular - Armstrong Ceiling Tiles P r o d u c t s & S e r v i c e s. AEROLITE . WOODWORKS Grille Wooden False Ceiling Wood Wool Acoustic Panel P r o d u c t s & S e r v i c e s. TEE GRID SYSTEM

4 Installing a Projector with the Ceiling Bracke t INSTALLING A PROJECTOR WITH THE CEILING BRACKET Overview Diagram of completed installation Ceiling Mount Device Installation Procedure Insert the U-PLATE into the CEILING ADAPTER, and tighten two M4 screws (from the bottom) into the screw holes. Then attach the top part to the ceiling.

Managing the risk of Coronavirus (COVID-19) in production making (Version 1) This document is intended as a highlevel framework to provide guidance and support for - the effective assessment and management of Coronavirus (COVID19) risk in TV production. - This should be read in conjunction with general guidance provided by the government about management of Coronavirus (COVID-19) risks in .