Zucker Hall - Lighting FacilitiesLighting InformationThe lighting system is in two parts.Fixed Orchestral: Provides a full cover of the stage in open white.These lanterns are located in ceiling panel and cannot be refocused or removed.Production Lighting Rig:The Production Lighting Rig is available for use below the Fixed Orcchestral system.The Production Lighting Rig is not silent.Control System & Network:Three control positions1 at FOH1 at the control booth1 on stageEach position contains the following connectors:4 DMX male connectors1 DMX female connector2 etherCON RJ45 Connector1 220v 16amp Israeli socketLight Network:All ethernet line from control postions go to patch panel in main power room.Each box truss contains 1 ethernet line from patch panel in main power room.6 ethernet line from stage level go to patch panel in main power room.2 ethernet line from Dimmer room go to patch panel in main power room.DMX:All DMX line from control postions go to patch panel in main power room.Each box truss contains 2 dmx line from patch panel in main power room.6 DMX line from stage level go to patch panel in main power room.1 DMX line from Dimmer room go to patch panel in main power room.Quantity11312EquipmentgrandMA2 ultra-light4 way artnet to dmx2 way artnet to dmxManaged GigabitEthernet switch with10 - 10/100/1000MbpsEthercon portsDMX splittersCommentsMain power roomBOX Truss 1,2,3Main power roomMain power room

Zucker Hall - Lighting FacilitiesDimmers:Located in the dimmers room and controlled via DMXAll Dimmer lines ends with Israeli sockets12121282kw dimmers box truss 1.2kw dimmers box truss 2.2kw dimmers box truss 3.2kw dimmers on stage.Stage power:Single phase 16AMP Israeli outlet controlled from main power room.18 on Each box truss for total of 546 on stage floor6 on main power room for auxiliary lighting gearSingle phase 16AMP Israeli outlets go to guest patch panel (powerCON) in main power room.12 on Each box truss for total of 36Three Phase Power – Lighting:Located in main power room.One (1) - CEE 125A 400V 5PTwo (2) - CEE 63A 400V 5PTwo (2) - CEE 32A 400V 5PTwo (2) - CEE 16A 400V 5PProduction Lighting:12 ETC ColorSource Spot12 Rush par 2 rgbw zoom12 Martin MAC Aura XB8 Martin MAC Quantum Profile4 martin Rush MH 1 profile1 Martin JEM Compact Hazer Pro

Zucker Hall- Multimedia System specificationSound:system manufactured : L-ACOUSTICS FranceSpeaker system including:123DescriptionL-R main clusterL-R fly subsG.SUBS45FRONT FILLspeakers balcony6AMPLIFIERSAND PROCESSORSModelKiva2SB15mSB18X86X X86X 5XTLA8 ,LA4xQuantity164Notes8 on each side2 on each side43122 on each sideaccording to the speakermanufacturer'sThe main clusters include a motor system (forward / backward) depending on thestage depth required (4m / 6m)The system will work in 2 operating modes to select the user:L / R TO ALL .12. L / R SUB AUX(If you select preset with "AUX" (additional input) all other array speakers will be fed from L / R inputs)A drawing with position of the speakers is attachedProjection:Rolling, Screen image dimensions: 550 cm, height 350 cmProjector: SONY, 6000 ANSI 1920/1080 resolutionCRESTRON DM routing system (controlled by the control system)CCTV:PTZ camera - to 1 monitors in green roomHearing aid system:X SENNHEISER IR PROJECTORS4Control system:AMXA central controller that controls all the systems (sound, projection, sound, etc)

Fixed touch screen 15 "at the operating position Stage equipment list: (will be provided by appointment only)12345678911121314DescriptionMicrophone standDynamic microphone for singingDynamic microphone formusical instrumentsDynamic microphone formusical instrumentsDrum MicrophoneMicrophone condenserDirect connection boxMonitor "12Monitor "15Wireless setWireless setDigital MixerDigital mixer - 48/24 stage boxQuantity1684ModelK&M S210/9BSM58SM574Audix I5168621111Audix D6AKG C451BSS103L-ACOUSTICS X12QSC KW152qlxd wl184qlxd sm58AVID S6-24AVID

12 Rush par 2 rgbw zoom 12 Martin MAC Aura XB 8 Martin MAC Quantum Profile 4 martin Rush MH 1 profile 1 Martin JEM Compact Hazer Pro Zucker Hall - Lighting Facilities. Line-A Line-B Line-C Line-D Line-E Line-F

Related Documents:

Irving Zucker Sculpture Garden This Sculpture Garden at the Art Gallery of Hamilton is named after a Hamilton-born businessman and philanthropist, Irving Zucker (1920-2002). Zucker grew up in the north end of Hamilton, and during World War II he joined the RCAF as a trained bomber and participated in the gunnery crew.

Dec 06, 2016 · COMMERCIAL LIGHTING 01-13 14-29 industrial lighting hazardous area lighting cleanroom lighting INDUSTRIAL LIGHTING street lighting area lighting induction lighting landscape lighting CITYSCAPE LIGHTING 30-51 ballast light sources HID lamps spares price list A

06.11.2017 4 Name der Präsentation Zucker in Lebensmitteln Zucker KH kcal Konfitüre, 20 g (50% Zucker) 12 13,2 53 Honig, 20 g 15 16 61 Fruchtjoghurt, 3,8% Fett,100 g 13,5 14,5 100 200 ml Orangensaft 17 18 85 Obstkuchen, Biskuitteig, 100 g 27 40 191 Obstkuchen, Mürbeteig, 100 g 18 31 238 Kugel Schokoladeneis, 56 g 15 18 150 Trinkjoghurt, Vanille, 100 g 12,9 13 80 Name der Präsentation

LIGHTING ( DEFINED ) OPEN AREA (ANTI-PANIC) LIGHTING ( UNDEFINED ) HIGH RISK TASK LIGHTING Emergency lighting standards tree. Escape route lighting. 1.Escape Route Lighting The emergency lighting on a route forming part of the means of escape from a point in a building to final exit. 2.Open Area (Anti-panic) Lighting The part of emergency .

Small Lighting controls 20 80/22 21 Small Lighting-only 20 80/22 18 Large Lighting controls 10 80/31 10 Large Lighting-only 10 80/31 7 2013-2014 Small Lighting controls 40 80/16 42 Small Lighting-only 20 80/22 21 Large Lighting controls 30 80/18 33 Large Lighting-only 10 80/31 10 Total 160 80/15 162

2 15 ' 1 2 15 ' 2 15 ' notes: mainline 1 typ. lighting limits interchange 215' lighting limits interchange lighting limits interchange lighting limits interchange lighting limits interchange 3. 2. 1. interchange lighting limits n.t.s. reports indicates. of what that the lighting justification the mainline will be illuminated regardless

Pathway Lighting Prescolite/Hubbell Siltron Sure-Lites/Eaton Lighting solutions LIGHTING, FLOURESCENT Alera Lighting/Hubbell Apogee Translite Bartco Lighting Columbia Lighting/Hubbell Coronet Lighting Day-Brite/Philips Finelite Focal Point Lighting H.E. Williams Holophane/Acuity

Am I my Brother’s Keeper? Sibling Spillover E ects: The Case of Developmental Disabilities and Externalizing Behavior Jason Fletcher, Nicole Hair, and Barbara Wolfe July 27, 2012 Abstract Using a sample of sibling pairs from the PSID-CDS, we examine the e ects of sibling health status on early educational outcomes. We nd that sibling developmental dis- ability and externalizing behavior are .