Variable Axial Piston PumpA10V Series - 52/53 Series 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) Sizes 10cm3/rev - 63cm3/rev (0.64in3/rev-3.8in3/rev) Control Options - Pressure, Pressure & Flow, and PowerSeries 52w w w. F l u i D y n e F P. c o mE m a i l : sales @ F l u i D y n e F P. c o m

Variable Displacement Pump A10V, Series 52/53Features:Axial piston pump A10V in swashplate design is used for hydrostatic transmission inopen loop circuits. Flow is proportional to drive speed and displacement. By adjusting theposition of the swashplate it is possible to smoothly vary the flow.VariablepistonPistonDFRControl 0V - 52/53- Flange/Threaded connections SAE-UNC or metric- 2 to 3 drain ports- High permissible speeds- Good suction characteristics- Low noise level- High power/weight ratio- Long service life- Short control times- Axial and radial loading of drive shaft possible- Wide range of controls- Through drive option for multi-circuit systemValveplate

Variable Displacement Pump A10V, Series 52/53Technical Data:1. Absolute Pressure at Port S (A)Psabs min.11 psi (0.8 bar)Psabs max.75 psi (5 bar)2. Output Operating Pressure RangePressure at port BNominal pressure PN.3600 psi (250 bar)Peak pressurePmax.4600 psi (315 bar)Minimum pressure Pmin. 145 psi (10 bar)3. Case Drain PressureMaximum pressure of leakage fluid (at ports L, L1 and L2) 7 psi (0.5 bar) higher than inputpressure at port S, but not higher than 30 psi (2 bar) absolute.4. Direction of Flow(S to B)5. Table of Values (theoretical values, without consideringSizemhandv: values rounded)1045606310.5 (0.61)45 (2.75)60 (3.66)63 (3.84)360026002600260018 (4.8)81.6 (21.6)108 (28.8)114 (30)DisplacementVg maxcm3/rev (in3/rev)Max. SpeedNnom maxrpmFlow @1800 rpmQvE 1800LPM (gpm)Max. FlowQv nom max L/min (gpm)37 (9.7)117 (31)156 (41)163 (43)Max. PowerPo maxkW (HP)35 (47)49 (65)65 (88)68 (90)Max. TorqueTmaxNm (lb-ft)42 (31)179 (132)238 (175.5)250 (48100)65500(48100)RNm/rad(lb-ft/rad) WNm/rad(lb-ft/rad) rad) 34400(25370)34400(25370)K /P 506)73900(54506)Mkg (lbs)8 (17)18(40)22 (48.5)22 (48.5)Rotary Stiffness,Drive ShaftWeight (without fluid)Note: Values shown are valid for an absolute pressure of 1 bar at suction port.

Variable Displacement Pump A10V, Series 52/53Technical Data:If the flow is reduced orif the inlet pressure isincreased the speed maybe increased accordingto the diagram.Speed vs. Inlet Pressure1.123(1.6)20(1.4)17.5 (1.2)14.5 (1.0)1.0130.90.70.80.91.0Inlet pressure p abs [psi (bar)]Speed n/n 0 max [rpm]1.2(0.9)11.5 (0.8)Displacement V g/V g max [in3 (cm 3 )]6. Determination of SizeFlowqv Torque T PowerFluidP Vg n ηv231Vg p24 π η mhqv p1714 η t[gpm][lb-ft][HP]MR20S (Q/TCNK12-2001)ISO 32ISO 46ISO 68(((qv T P Vg n ηvVg p20 π η mhqv p600 η t)))[L/min]1000[Nm][kW]V g Displacement per revolution in in3 (cm 3 ) p Differential pressure in psi (bar)n Speed in rpm (min –1 )η v Volumetric efficiencyη mh Mechanical-hydraulic efficiencyη t Total efficiency

Variable Displacement Pump A10V, Series 52/53Technical Data:Operating Viscosity RangeVopt 16 mm2 /s 36 mm2 /s (80 to 170 SUS)For optimum efficiency and service life we recommend that the operating viscosity (atoperating temperature) be selected in the range:Vopt optimum operating viscosity 16mm2 /s 36 mm2 /sreferred to tank temperature (open loop circuit).Limits of Viscosity Range(The following values are valid for extreme operating conditions)Vmin 10 mm2/sfor short periods at max. leakage oil temperature of 800C (1760F)Vmax 1000 mm2/sTemperature Rangetmin -200C (-40F) ; tmax 800C (1760F)FiltrationInstallation NotesViscosity7400460030002000-4 32 68 104 140 176 212 F-40 16001000600400-20 0 20 40 100020050010030060200401008020601060 80 100 C16007400010VG 68VG46VG32VG22VGIn order to ensure reliableoperation of the axial pistonunit, the operating fluid mustbe maintained to a cleanlinessclass of at least: 16/19 to IS04406.This may be achieved with filterelements, cleanliness class of10µm.-40 SUS mm2/s425-40 -25 10 0 10 30 50 -40 -13 14 32 50 86 122 158 194 t min -40 F (-40 C)70 Temperature tFluid Temperature Range90 361701680mm2/s SUS542115 C240 Ft max 240 F (115 C)The pump housing must be filled with fluid during commissioning and remain full whenoperating. The concentricity between engine transmission shaft and pump shaft mustless than 0.05mm.

Variable Displacement Pump A10V, Series 52/53Technical Data:Technical dataDrive Power and FlowOperating material:ISO VG 46 DIN 51519, t 50 COperating material:Hydraulic fluid ISO VG 46 DIN 51519, t 50 CSize 10n 1500 rpmn 3600 rpmFlow q V107.552.5Size 45(L/min)(35)qV(25)pqV max(15 )(5)pqV min0(50)n 1500 rpm(100)1000n 2600 rpmpsi(20)1000(100)(150)2000200(250) (bar)(200)30003625 psiOperating pressure pSize 60/63n 1500 rpmn 2600 rpm(kW ) H P(80)100(70)gpm (L/min)(160)40(140)35(120)30(100)2520 (80)15(60)10(40)5(20)qv(60) 80Pqv max(50)(40)60(30) 40Pqv min0(50)01000(100)(150)2000(200)3000Operating pressure p(20)(10)20(250) (bar)3625 psi0Drive power P qv(50)(10)Drive power Pqv(20)Flow q vFlow q v60Pqv max (40)(30) 40Pqv min0(250) (bar)20003000 3625Operating presure p(50)qv15 (60)10 (40)0(200)(kW ) H P(60) 80gpm (L/min)(120)30(100)2520 (80)5(150)(kW) HP30(20) 25(15 ) 20(10 ) 1510(5)50Drive power P q Vgpm

Variable Displacement Pump A10V, Series 52/53Ordering rol DevicesPressure controlPressure remote controlPressure & Flow(X-T port open)(X-T port blocked)DRDRGDFR, DRF2)DFR1, DRS2)Power Control w/ pressure cut-offLA(X)D2)LA(X)DG2)LA(X)DS2)Power control w/ pressure cut-offPower w/remote pressurePower w/flow (X-T port blocked)XStart of controlLA5D - 10 to 35 bar (145-507 psi)LA6D - 36 to 70 bar (522-1015 psi)LA7D - 71 to 105 bar (1030-1523 psi)LA8D - 16 to 140 bar (1537-2031 psi)LA9D - 141 to 230 bar (2045-3336 psi)SeriesSeries10 45 60 63 5253Direction of RotationViewed from shaft endRLClockwiseCounter-clockwiseSealsPVBuna-N (NBR per DIN ISO 1629)FPM (Flurocarbon/Viton)Shaft End10456063Keyed3/4”1”1 1/4”1 1/4"Splined3/4"-11T1"-15T1 1/4"-14T1 1/4"-14T 1"-15T1 1/4"-14T1 1/4" -14T5/8"-9T7/8"-13T1"-15T1"-15TFull Splined -Reinforced "U" 7/8"-13T1"-15T1"-15TFull Splined SAE-B 7/8"-13T7/8"-13T18mm Full Splined -Reinforced "S"Splined "Low Torque"Metric KeyedKSRUWQP

Variable Displacement Pump A10V, Series 52/53C62N00S097Special Suffix 097Omit if none requiredMax volume stop adjust (std)Thru Drives10Non-Thru Drive (without thru drive)With Thru Drive to mount pump on back (side ports only) Mtg FlgHubTo Mount82- 2 (A)5/8"-9T (A)A10V18(U,W), 10(U) 82- 2 (A)3/4"-11T (AB)A10V18(S,R), 10(S) 101- 2 (B)7/8"-13T (B)A10V28(S,R), 45(U,W) 101- 2 (B)1"-15T (B-B)A10V45(S,R), 60/63C(U,W) 127- 2 (C)1 1/4"-14T (C)A10V71(S,R), 100(U,W) 127- 4 (C)1 1/4"-14T (C)A10V60/63D(S,R) Service Ports4-BoltFlange PortsStr. ThreadO-Ring Ports Rear Ports, UNC Thread Side Ports, Metric Thread Side Ports, UNC Thread Rear Ports, Threaded MetricRear Ports, Threaded UNCMounting FlangePilot Diameter (in/mm)SAE-ASAE 2-BoltISO 2-Bolt MetricSAE 4-Bolt Available Not available1045SAE-B63 60 10Rear Ports, Metric Thread454560 60SAE-BK01K52K68/K02K04K07K1563 N00K** (4.0"/101.6)SAE-BC80 mm100 mm A SAE-CDSAE-C(5.0"/127)(5.0"/127)Note:1) Series 52 units are delivered as standard with 60 cm3/rev. Higher values on request.2) Control DRF, DRS, and LA(X)D(): Available with size 18, and 63, only in 53 series.

Variable Displacement Pump A10V, Series 52/53Pressure Control “DR”:The pressure control serves to maintaina constant pressure in the hydraulic system,within the control range of the pump. The pumptherefore supplies only the amount of hydraulicfluid required by the actuators. Pressure maybe smoothly set at the pilot valve.L spmax(at n 1 1500 rpm; tfluid 120 F (50 C))BSL, L1,2Pressure portSuction portCase drain ports (L1,2 sealed)Hysteresis / pressure riseSetting range 1)Operating pressure p Bpsi (bar)3600 (250)290(avail. 53-design only)(20)Flow q v [gal (l/min)]Control DataHysteresis and repetitive accuracyp.max. 3 bar (44 psi)Max. Pressure IncreaseSize PBar (psi)106 (90)45606 (90) 8 (115)638 (115)Pilot oil consumption.max. approx. 3 L/min (0.8 gpm)

Variable Displacement Pump A10V, Series 52/53Pressure Control, Remote Control “DRG”:Not included in the delivery contentsFunction and design as for DR.A pressure relief valve may be externally piped toport X for remote control purposes. It is not, however,included with the DRG control.XThe differential pressure at the pilot valve is setas standard to 20 bar (290 psi) and this results in apilot flow of 1.5 L/min (0.40 gpm). If another settingis required (in the range of 10-22 bar) (145-319 psi),please state this in clear text.LL1BStatic characteristicStaticCharacteristic(at n 1 1500 rpm; tfluid 120 F (50 C))pmaxHysteresis / pressure riseSetting range 1)Operating pressure p Bpsi (bar)3600 (250)290(20)Flow q v [gpm (l/min)]Control DataHysteresis and repetitive accuracyL2 (avail. 53- design only)PortsBSL, L1,2XPressure portSuction portCase drain ports (L1,2 sealed)Pilot pressure portP. max. 3 bar (44 psi)Max. Pressure IncreaseSize10456063PBar (psi) 6 (90) 6 (90) 8 (115) 8 (115)Pilot oil consumption.max. approx. 4.5 L/min (1.19 gpm)S

Variable Displacement Pump A10V, Series 52/53X“DFR/DRF” X-T port open, “DFR1/DRS” X-T port blockedIn addition to the pressure control function,the pump flow may be varied by means of adifferential pressure at the actuator (e.g. anorifice).In model DFR1/DRS the X orifice is plugged.L L1BNot included in the delivery contentsPlugged in DRS (DFR1) valvePressure/Flow Control, Load Sensing:Static characteristicStaticCharacteristicFlow control at n 1 1500 rpm; tfluid 120 F (50 C))pmax290(20)L2 (avail. -53 design only)PortsBSL, L1, 2Flow q v [gpm (l/min)]XPressure portSuction portCase drain ports (L1,2 sealed)Pilot pressure portpmaxStatic characteristic at variable speedFlow q v [l/min]Flow control/differential pressure p:Adjustable between 14 and 22 bar (200-320 psi)(higher values on request). Standard setting: 21 bar(300 psi). If a different setting is required, please statein clear text.When port X is unloaded to tank, a zero strokepressure of p 21 bar (300 psi) (“stand by”) results.SSpeed n [rpm]Hysteresis / pressure riseHysteresis / pressure riseSetting range 1)Operating pressure p Bpsi (bar)3625 (250)Control DataFor pressure control technical data see DR Pressure control.Max. flow deviation (hysteresis and increase) measured at drive speed n 1450 rpmSizeΔQmaxL/min (gpm)101.5 (0.5)451.8 (0.48)60/632.5 (0.66)Pilot oil consumption DFR/DRF.max. approx. 3-4.5 L/min (0.8-1.19 gpm)Pilot oil consumption DFR1/DRS.max. approx. 3 L/min (0.8 gpm)

Variable Displacement Pump A10V, Series 52/53Pressure, Flow, and Power Control “LA(X)D.”:Pressure control equipped as DR(G), see page 11.Flow control equipped as DRF, DRS, see page 12.In order to achieve a constant drive torque with varying operating pressures, the cradle and withit the output flow from the axial piston pump is varied so that the product of the flow and pressureremains constant.Flow control is possible belowthe power control curve.Torque T [ lb-ft (Nm) ]4563Start of Controlpsi (bar)When ordering, the powersetting requirements mustbe given:(ie: 27 HP(20kW) @ 1500 rpm,and 3,045 psi (210 bar) maxsystem pressure).OrderCode145-510 (10-35)7.4-22.1 (10-30)11-32 (15-43)LA5520-1015 (36-70)22.2-43.5 (30.1-59)32-61 (43.1-83)LA61030-1520 (71-105)43.6-62 (59.5-84)61-88 (83.1-119)LA71535-2030 (106-140)62-83 (59.1-84)88-116 (119-157)LA82045-3335 (141-230)83-139 (112.1-189)116-195 (157.-264)LA9Circuit diagram (LAXD)Static curves and torque characteristicOperating pressure p BStatic Curves and Torque Characteristicps i (bar)4350 (300)Circuit diagram (LAXDG)with pressure cut-o2900 (200)LA92175 (150)LA81450 (100)LA7725(50)0(0)ly operatedX3620 (250)XNot includedin the deliverycontentsLA60100LA5 qVCircuit diagram (LAXDS)(see table above)Torque T [lb-ft (Nm)]LA9XXNot includedin the deliverycontentsLA8LA7LA6LA50Vv [%]LL1B100L2S

Variable Displacement Pump A10V, Series 52/53A10V10 Dimensions:DR - Hydraulic Pressure ControllerClockwise Rotationmax. 4.33 ( 110)(56)2.87 (73)0.43 (11)0.25 (6.4)2.20L0.D IA 0 . 4 32 .11 ( 5 3 . 5 ) ( ø 11)2 .2 0 ( 5 6 )45 FlangeISO3019-145 D IA 3 . 2 5 03 .2 4 8( ø 8 2 . 5 5 -00 .0 5 4 )35)(9YL14.19 (10 6.4)5.28 (134)0.94 (24)5.83 (14 8)7. 09 (18 0)View YClockwiseRotationView YCounter-ClockwiseRotationBSBS1.13 1.13(28.6) (28.6)1.13 1.13(28.6) (28.6)2.00 (51) 2.00 (51)2.00 (51) 2.00 (51)

Variable Displacement Pump A10V, Series 52/53A10V10 Dimensions:DRG / DFR / DFR1 - Hydraulic ControllerClockwise Rotationmax. 4.33 (110)1.57(40)5.75 (146)X3.74 (95)4.02(102)LL17.05 (179)Metric Mounting Flange and ShaftP - Parallel Keyed Shaft20.5mm diameterDIN 6885 A6x6x25 key116.4282 0.3025ø 8020.5ø22-0.10-0 .0 4 60.009ø18 - 0.004FlangeISO 3019-224CenteringR3 15 x 6.7DIN 33236X

Variable Displacement Pump A10V, Series 52/53A10V10 Dimensions:Drive Shafts and Port DimensionsK - Parallel Keyed Shaft3/4” diameter; 3/16” sq. keyISO 3019-1 19-1Centering 4)R 0.12x0.26DIN 3321.18 (3 0)) 0.0251/4-20UNC-2B0.188 (4.760.1870.833 0.050.827 21.1 -0.1-0.02 )1.13(28.6)(ø19.05DIA0.7500.7490.01(2.5)S - Splined Shaft3/4” diameter; 11T 16/32 DP1)SAE J7440.350.19(14)(5 )0.87(21)1.30 (33)0.31 (8)1.61(41)1.50 (3 8)U - Splined Shaft5/8” diameter; 9T 16/32 DP1)SAE J7440.94 (23. 8)4)CenteringR12 x 0.26DIN 3320.62(15.8)1.25 (3 1.8)PortCodePortsStandardSizeMax Tightening TorqueBSOutlet Port, Rear ThreadedInlet Port, Rear Threaded641-1/16-12 UNF-2B; 0.79"(20) deepISO 11926 1-1/16-12 UNF-2B; 0.79"(20) deep243 lb-ft (330 Nm)BSOutlet Port, Rear ThreadedInlet Port, Rear Threaded14ISO 11926 M27x2; 0.63" (16) deepDIN 3852 M27x2; 0.63" (16) deep243 lb-ft (330 Nm)L, L1Case Drain Ports (L1 plugged)XPilot Pressure Port64/14ISO 11926 9/16-18UNF-2B; 0.43" (11) deep59 lb-ft (80 Nm)64/14ISO 11926 7/16-20UNF-2B; 0.45 (11.5) deep29 lb-ft (40 Nm)

Variable Displacement Pump A10V, Series 52/53A10V45 Dimensions:DR - Hydraulic Pressure ControllerClockwise Rotation 2), -52 SeriesPort plate 61/113.90 (99 )0.47 (12 )1.18 (3 0)L1FlangeISO 3019-1(7DIA 4.000( Ø101.6 )8)L0.56 (14.3)3.03 (77)45 5.18 (131.5)X7.44 (18 9)max. 8.68 (220.5)2.70 (68.5)3.070.37 (9.5)0.25 (6.3)5.75 (146)6.77 (172 )View XSB1.50(3 8)1.50(3 8)1) Primary dimensions for pump apply for series -52 and -53 as seen above.2) Location of service ports S and B are turned 180 for counter-clockwise rotation.2.0(52 6.4)S1.4(35 1.7)D IA 0 .9 8(ø2 5 )2.75D IA 1.5 0 (69.9)ø3 8Port plate 6430 1.0(26 3 30 .2)1.50 1.50(3 8) (3 8)B

Variable Displacement Pump A10V, Series 52/53A10V45 Dimensions:DR - Hydraulic Pressure ControllerClockwise Rotation 2), -52 SeriesPort plate 62/12Detail ZL( Ø101.6 )DIA 4.000FlangeISO 3019-1max. 8.68 (220.5)5.93 (150.5)3.90 (9 9)0.47 (12)1.18 (3 0)L17.01 (178 )8.31 (2 11)SDIA 1.50 (ø38)69.90.37 (9.5)0.25 (6.3)2.06 (52.4)DIA 0.98 (Ø25)B1.41 (35.7)Y1.03(26.2)View YSB3.54 (9 0)3.54 (9 0)Z

Variable Displacement Pump A10V, Series 52/53A10V45 Dimensions:DRG / DFR / DFR1 1) 3) - Hydraulic ControllerRemote Pressure Control/ Pressure and FlowClockwise Rotation 2), -52 Seriesmax. 8.68 (220.5)5.93 (150.5)2.68 (68)5.18 (131.5)4.53 (115)L1LXSLA( )D(S/G) 1) 4) - Hydraulic ControllerPressure, Flow and Power ControlClockwise Rotation 2), -53 Series9.25 (235)5.75 (146)2.68 (68)L1S5.24 (133)4.57 (116.4)XXL21) Primary dimensions for pump apply for series -52 and -53 as seen on page 18.2) Location of service ports S and B are turned 180 for counter-clockwise rotation.3) DFR1; Pressure and flow control with blocked bleed down orifice4) Only for -53 series.L

Variable Displacement Pump A10V, Series 52/53A10V45 Dimensions:Drive Shafts and Port DimensionsK - Parallel Keyed ShaftS - Splined Shaft1.50 (38.1)1.37 (34. 9)0.631.0" major dia.15T 16/32 DPSAE J744-25-4 (B-B)1.49 (38)0.250 (6.35)DIA .2)DIA 1.00(ø25.4 )1.0” diameter; 1/4” sq. keyISO 3019-1 25-10.63 (16)0.20 (5)1.18(3 0)(16 )1.81(45. 9)1.81 (46)1.0" major dia.15T 16/32 DPSAE J744-25-4 (B-B)U - Splined Shaft7/8" major dia.13T 16/32 DPSAE J744-22-4 9.5)0.63 (16 )0.63 (16)0.20 (5 )0.99(25.1)1.81 (45.9)Ports7/8" major dia.13T 16/32 DPSAE J744-22-4 (B)1.30 (33.1)0.63 (16 )0.20 (5 )W - Splined Shaft1/4-20UNC-2BR - Splined ShaftUsable0.98 (25)shaft length1.61 (41)1.61 (41)PortCodeStandard0.20 (5)SizeMax TighteningTorqueBSOutlet Port, SAE Flange (code 61)Inlet Port, SAE Flange61/62SAE J518;ISO 68BSOutlet Port, SAE Flange (code 61)Inlet Port, SAE Flange11/12SAE J5183); 1.0"; M10 x 1.5; 17 deepDIN 131-1/2"; M12 x 1.75; 20 deepBSOutlet Port; ThreadedInlet Port; Threaded64ISO 119261-5/16"-12UN-2B; 0.79 (20) deep1-7/8-12UN-2B; 0.79 (20) deep243 lb-ft (330 Nm)L, L1,L2 4)Case Drain Ports (L1 plugged)AllISO 119263/4-16UNF-2B116 lb-ft (160 Nm)XPilot Pressure PortAllISO 119267/16-20UNF-2B; 0.45 (11.5) deep1) Primary dimensions for pump apply for series -52 and -53 as seen above.1.0"; 3/8-16UNC-2B; 0.75 (19) deep1-1/2"; 1/2-13 UNC-2B; 0.87 (22) deep2) Location of service ports S and B are turned 180 for counter-clockwise rotation.3) Metric fixing thread is a deviation from standard.4) Only for -53 series.31 lb-ft (42 Nm)48 lb-ft (66 Nm)29 lb-ft (40 Nm)

Variable Displacement Pump A10V, Series 52/53A10V60/631) Dimensions:DR - Hydraulic Pressure ControllerMounting Flange C, Clockwise Rotation 2), -52 SeriesA10V (60/63)DR/52R-PSC61N00Port plate2) 61/11max. 8.68 (220.5)4.61 (117 )1.57(4.0)L1XL5.39 (137)45 78.5DIA 4.00(Ø101.6)FlangeISO 3019-10.56 (14.3)3.42 (87)0.37(9.5)2.99 (78)X5.75 (146)6.77 (172 )0.59 (15 )8.19 (208)SBView X2.06(52.4)3.06 (77.8)DIA 1.97(Ø50)Port plate2) 64BSSB1.67 )0.98 (Ø25)View X1.81(46)1) Primary dimensions for pump apply for series -52 and -53 as seen above.2) Location of service ports S and B are turned 180 for counter-clockwise rotation.1.81(46)1.03 (26.2)

Variable Displacement Pump A10V, Series 52/53A10V60/631) Dimensions:DR - Hydraulic Pressure ControllerMounting Flange C, Clockwise Rotation 2), -52 SeriesA10V (60/63)DR/52R-PSCxxN00Port plate2) 62/12X1.67(42.9)2.83 (72)1.11 (26.2)Smax. 8.68 (220.5)4.61 (117 )ZBBView YX1) Primary dimensions for pump apply for series -52 and -53 as seen above.2) Location of service ports S and B are turned 180 for counter-clockwise rotation.L(78.5)45 09Y4.51 (114 .5)5.75 (146)114.53.43 (87)3.07 (78)7.93 (201.5)9.43 (239.5)L15.41 (137.4)DIA 5.00(Ø127 )1.67(42.9)S2.83 (72)3DIA 1.97 (Ø50)3.06 (77.8)2.83 (72).140.59 (15 )A10V60/63- DMounting Flange2.06 (52.4)0.98 (Ø25)A10V (60/63)DR/52R-PSDxxN00FlangeISO 3019-12.83 (72)View Z7.93 (201.5)9.43 (239.5)1.57(40)BSMounting Flange D 1), Clockwise Rotation 2), -52 Series0.50(12 .7)ZY3.0.59 (15 )SDIA 4.00(Ø101.6 )DIA 1.97 (Ø50)3.06 (77.8)FlangeISO 3019-11.57(40)View Y5.83 (148)0.50(12 .7)max. 8.68 (220.5)4.61 (117 )

Variable Displacement Pump A10V, Series 52/53A10V60/631) Dimensions:DR - Hydraulic Pressure ControllerMounting Flange D, Clockwise Rotation 2), -53 SeriesA10V (60/63)DR/53R

Axial piston pump A10V in swashplate design is used for hydrostatic transmission in open loop circuits. Flow is proportional to drive speed and displacement. By adjusting the position of the swashplate it is possible to smoothly vary the flow. A10V - 52/53 Valve plate End cover Control valve Variable Piston DFR piston Cylinder block Swash plate .

Related Documents:

for your axial piston variable pump A10VO or A10VSO. Please request the installation drawing from your contact at Bosch Rexroth. Installation drawing Axial piston variable pump A10V(S)O, size 18 (A10VSO), size 28 to 140 (A10VO) Contains the permissible technical data. 92701 Data sheet Axial piston variable pump A10VSO, size 18 to 140

4 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com Features Axial piston pump A10V in swashplate design is used for hydrostatic transmissions in open loop circuits. Flow is proportional to drive speed and displacement. By adjusting the position of the swashplate it is possible to smoothly vary the flow.

Axial piston variable pump A10V(S)O Series 31 Technical data, standard unit 7 Technical data, standard unit Size NG 18 28 45 71 88 100 140 Displacement, geometric, per revolution V g max in3 1.10 1.71 2.75 4.33 5.37 6.10 8.54 (cm3) (18) (28) (45) (71) (88) (100) (140) Rotational speed maximum1) at V g max n nom rpm 3300 3000 2600 2200 2100 .

Axial piston unit 02 Swashplate design, variable, nominal pressure 280 bar, maximum pressure 350 bar l – – – – – A10VS – l l l l l A10V Operation mode 03 Pump, open circuit O Size (NG) 04 Geometric displacement, see table of values on pages 6 and 7 18 28 45 71 100 140 Control device 05 Two-point control, directly operated l l l l l l DG

Axial piston variable pump A7VO Data sheet Series 63 Sizes NG250 to 500 Nominal pressure 350 bar Peak pressure 400 bar Open circuit RE 92203/06.09 1/52 Replaces: 05.99 Features – Variable axial piston pump with tapered piston rotary group in bent axis design for hydrostatic drives in open circuits

3042f012 dpa pump 3042f022 dpa pump 3042f050 dpa pump 3042f052 dpa pump 3042f062 dpa pump 3042f080 dpa pump 3042f101 dpa pump 3042f102 dpa pump 12 volt 3042f110 dpa pump 3042f150 dpa pump 3042f152 dpa pump 3042f152-r dpa pump 3042f170 dpa pump 3042f171 dpa pump 3042f172 dpa pump 3042f210 dpa pump 3042f212 dpa pump 3042f213 dpa pump 3042f213-r .

7.4.9 Hydraulically connecting the axial piston unit 36 7.4.10 Electrically connecting the axial piston unit 41 7.5 Performing flushing cycle 42 8 Commissioning 43 8.1 Initial commissioning 43 8.1.1 Filling the axial piston unit 43 8.1.2 Testing the hydraulic fluid supply 44 8.1.3 Performing a functional test 45 8.2 Running-in phase 45

During the American Revolution both the American Continental Army and the British Army had spies to keep track of their enemy. You have been hired by the British to recruit a spy in the colonies. You must choose your spy from one of the colonists you have identified. When making your decisions use the following criteria: 1. The Spy cannot be someone who the Patriots mistrust. The spy should be .