SUPER LINE P SERIESTHREE PHASEINDUCTION MOTORPREMIUM EFFICIENCY IE3For the sake of the planet,motors have their own part to play

Global PlayerGLOBAL IMPACT OFMITSUBISHI ELECTRICMitsubishi Electric is involved in many areas including the followingWe bring together the best minds tocreate the best technologies. AtMitsubishi Electric, we understandthat technology is the driving force ofchange in our lives. By bringinggreater comfort to daily life,maximizing the efficiency ofbusinesses and keeping thingsrunning across society, we integratetechnology and innovation to bringchanges for the better.Energy and Electric SystemsA wide range of power and electrical products from generators to large-scaledisplays.Electronic DevicesA wide portfolio of cutting-edge semiconductor devices for systems andproducts.Home AppliancesDependable consumer products like air conditioners and home entertainmentsystems.Information and Communication SystemsCommercial and consumer-centric equipment, products and systems.Industrial Automation SystemsMaximizing productivity and efficiency with cutting-edge automationtechnology.1

ContentsOVERVIEW4Lineup51 SF-PR80M 225SFOOT TYPETOTALLY ENCLOSED FAN-COOLED TYPE, IP44 DEGREES OF PROTECTION(Indoor Motor)62 SF-PRO80M 225SFOOT TYPETOTALLY ENCLOSED FAN-COOLED TYPE, IP44 DEGREES OF PROTECTION(Outdoor Waterproof Motor)93 SF-PRP80M 225SFOOT TYPETOTALLY ENCLOSED FAN-COOLED TYPE, IP55 DEGREES OF PROTECTION(Outdoor Dust & Water jet proof Motor)114 SF-PRV / SF-PRF80M 225SVERTICAL / HORIZONTAL FLANGE TYPETOTALLY ENCLOSED FAN-COOLED TYPE, IP44 DEGREES OF PROTECTION( Vertical / Horizontal Flange Motor )135 SF-PRB80M 225SFOOT TYPE BRAKE MOTORTOTALLY ENCLOSED FAN-COOLED TYPE, IP44 DEGREES OF PROTECTION(Motor with Brake)15 SF-PRF (Horizontal flange type) frame number 225S is not available.2

Contributing to energy conservation withtechnology, while maintaining the ease of use of general-purpose motors.With proprietary steel frame technology, Mitsubishi Electric will continue to develop and sellHigh performance energy-saving motorSuper Line Premium SeriesSF-PR TypeCOREROTORRotor slot shape is adopted inorder to address startupcharacteristics while suppressingoperating resistance.Furthermore, the number of slotsis also optimized.FANThe shape of the cooling fanis developed for enhancedbalance between coolingperformance and mechanicalloss.3Low generation loss materials are usedfor the iron core, while the shape isCOILElectric wire resistance is suppressedwith increased cross-sectional areadue to improved wire space factor,and by reducing the crossover area.FRAMEThe frame is made of a steel plate that easily transfers

IE Coderegulations for three-phase motorsIEC 60034-30 (efficiency classes of single-speed, three-phase,squirrel-cage induction motors) was enacted in October 2008as an international standard for motor efficiency. The efficiencydefined therein is classified into levels from IE1 to IE4, andthe larger this number is, the higher the efficiency will be.Global warming prevention countermeasures are gainingimpetus around the world (demand for CO2 reduction)Global Electricity Consumption in 2010Other 6%Electrical equipment 10%IT equipment, electrical appliances, etc.Electrothermal equipment(heaters) 19%Electric heating furnaces,electric boilers, etc.World total power generation21.4 trillion kWh (2010)Lighting19%Source: MOTOR SUMMIT 2012Key World Energy STATISTICS 2012Country (region)20092011 2010/12/19 2010/12/19IE3IE2SF-JR201320142015201620172018 Target start date 2015/4/1Top Runner (IE3)(Foot-mounted type, etc. conventional IE2 compliant products)(Flange type, etc.) 2016/9/1 (7.5 kW up) (New GB2) IE3 2017/9/1 (0.75 kW up)(New GB2) IE3IE2 2012/9/1(New GB3) IE2Korea 2011/6/16 2015/1/1 (7.5 kW up)IE2IE3 2017/1/1 (0.75 kW up)IE3 2015/10/1 (37 kW or more - less than 200 kW) IE3 2016/10/1 (200 kW or more - 375 kW or less) IE3 2018/10/1 (0.75 kW or more - less than 37 kW) IE3IE2Mexico 2011/1/1IE3 2013/1/1 on: Mandatory energy labelingVietnamstandardsSuper Line Series(Non-standard)2012 2011/7/1(GB2)EuropeSafety standardsSF-HRfor Top Runner systemChinaCountry and regionSuper Line Eco SeriesIE1 Standard Efficiency Enforced 2013/11/1IE2SF-PRIE2 High EfficiencyJapanUnitedStatesMM-EFSSuper Line Premium SeriesUnited States, Japan,China, Europe, KoreaIE3 Premium EfficiencyEfficiency class standards,an international standard for theglobal market, were established (in2008) to expand and promote theadoption of high-efficiency motors.2010Mitsubishi product seriesPremium high-efficiency IPM motorIE4 Super Premium Efficiency2% of total power generation canbe reduced by improving motorefficiency (about 5%)Motors46%Major regulatorycountriesIEC standard efficiency class (IE Code)The power consumed by motors is 46%of total global electricity generation. Power consumption of 9.8 trillion kWhIE1 original criteria 2016/1/1United StatesUL StandardsEISANEMA MG1-12-12ChinaCCC Marklabeling implementationregulationsGB18613-2012EuropeCE -1(2014)KoreaMexicoVietnam———grade indication systemKS C 4202NOM-016-ENER-2010No.51/2011/QD-TTgTCVN 7540-1:2013—Use for high level IE3 onlyIE3IE12010/12/19 on 2016/6/1 on 2016/9/1 on 2017/9/1 on 2015/1/1 on 2017/1/1 on 2015/10/1 on 2016/10/1 on 2018/10/1 on2011/1/1 on2016/1/1 on0.75 to 150 kW 0.75 to 373 kW 7.5 kW or more - 0.75 kW or more - 7.5 kW or more - 0.75 kW or more - 37 kW or more - 200 kW or more - 0.75 kW or more (1 to 200 HP) (1 to 500 HP) 375 kW or less 375 kW or less 375 kW or less 375 kW or less less than 200 kW 375 kW or less less than 37 kW0.746 to 373 kW0.75 to 150 kWNEMA Premium(IE3)Start timeTarget motorsOutputGrade GB2 (IE3)IE3 or IE2 Variable speed driveIE3Number ofpoles2-pole, 4-pole, 2-pole, 4-pole,6-pole6-pole, 8-pole2-pole, 4-pole, 6-pole2-pole, 4-pole, 6-pole2-pole, 4-pole, 6-pole, 8-pole2-pole, 4-pole, 6-pole2-pole, 4-pole, 6-poleVoltage230 V, 460 V600 V or less230/460 V1000 V or less1000 V or less600 V or less600 V or less1000 V or lessFrequency60 Hz50 Hz50 Hz, 50/60 Hz60 Hz60 Hz50 Hz, 60 HzRatingS1S1, S3 80% EDS1, S3 80% EDS1, S3 to S10S1S1Inverter drive dedicatedBuilt-insubmersible motorHigh slip motorInverter drive dedicatedBuilt-inMotor for specialenvironments—Geared motorInverter drive dedicatedBuilt-inMotor for special environmentsExceptionsBrake motorBuilt-in submersible motorMotor for specialenvironmentsInverter drive dedicatedBuilt-in4

LineupSF-PR (Indoor Motor)P6Contributing to energy conservation with advanced highFeatures(1) Compatible mounting dimensionsWith the exception of some models, the total length and shaft dimensions are the same(2) Combination with power distribution control equipmentSpecially designed for use with power distribution control equipment equivalent tothat of SF-JR.SF-PRO (Outdoor Waterproof Motor)P9Can be used safely outdoors, even under weatherconditions such as rain, wind, snow, etc.Features(1) Waterproof performance (IP44 Degrees of protection)Passed the water spray test for compliance with JIS C 4034-5, and can be securelyused outdoors.SF-PRP (Outdoor Dust & Water jet proof Motor) P11Operates normally under severe outdoor conditionsFeatures(1) Dust & Water jet proof performance (IP55 Degrees of protection)Passed the dust and the water spray test for compliance with JIS C 4034-5, so it canSF-PRV (Vertical Flange Motor)P13SF-PRF (Horizontal Flange Motor)Features(1) Compatible mounting dimensionsWith the exception of some models, the total length and shaft dimensions are the same(2) Combination with power distribution control equipmentSpecially designed for use with power distribution control equipment equivalent to thatof SF-JRV / SF-JRF.SF-PRB (Motor with Brake)P15Low noise, compact/lightweight motor with brakeFeatures(1) Energy saving / CO2 reduction(2) Guaranteed compatibility Mounting dimensions: Same mounting dimensions as SF-JRB. Same motor frame number and mounting dimensions as SF-PR. (3) Low noiseDue to the sound absorbing material used for the TB-A brake part, it features low noisewith less impact sound during brake release. (Operating noise 75 dB or below) Production Model ListModelTotally-enclosed Fancooled TypeModelTotally-enclosed Fancooled TypeModel NameSF-PR(O,P,V,F)SF-PRBModel NameSF-PR(O,P,V,F)SF-PRBFrame Number4 Poles4 PolesFrame Number4 Poles4 0LD37,4537,45132M7.57.5225S5555 The output listing in the above table is the production range. SF-PRF (Horizontal flange type) frame number 225S is not available.5

Premium Efficiency MotorsSF-PR 80M 225S FOOT TYPETOTALLY ENCLOSED FAN-COOLED TYPE, IP44 DEGREES OF PROTECTION (Indoor Motor)FeaturesAs the SF-PR type is compatible with conventional products(SF-JR, SF-HR), it is available not only for use as a newproduct, but also for conventional product replacement.Furthermore, inverter surge protection and reinforcedinsulation are implemented in all motor models. Compatibility Can be easily mounted on existing equipment as well as on newequipment.(1) Mounting dimensionsSame mounting dimensions as the standard efficiency motor.(Can fit into the existing space)(2) Power distribution control equipmentUses the same power distribution control equipment as standardefficiency motors.Note 1. When using Mitsubishi Electric Circuit Breaker NF400-SW at 55 kW, replace the breaker.(Be sure to change the rated current of the NF400-SW breaker from 300A to 350A)2. The existing thermal may be tripped if the unit is used for replacement in applicationswith a high load inertia moment. Contact the nearest sales office to handle this.Powersupply(2) Power distributioncontrol equipmentEnergy-saving Effects Power generation loss is reduced by 40-50% compared to(SF-HR), power generation loss is reduced by 20 to 30%,Enables further energy saving operation.* Some models are excluded.4P 380V 50Hz1009590Breaker85IE3 standardSF-PRSF-HRSF-JR807570Electromagneticswitch withthermal relay0.75 1.5 2.2 3.7 5.5 7.51115 18.5 22Output [kW]30374555(1) MountingdimensionsCharacteristics after Replacementciency.Slip (%)74 Poles644 PolesSF-PRSF-HR1.8SF-PRSF-HRSF-JR5Starting current ratio2.01.61.431.221.0100.75 1.5 2.2 3.7 5.5 7.51115 18.5 22Output [kW]3037* The smaller the slip, the faster the rotation speed. All above graph datas are based on Mitsubishi Electric Japan motors.45550.80.75 1.52.23 .75.57.51115 18.5 22Output [kW]30374555* The starting current ratio of SF-HR and SF-PR is shown when the starting current of theconventional model SF-JR is set to 1.0.6

Model NameSSymbol ConstructionSSuper LineSeriesF–PRSymbol Enclosure TypeFV O BSymbolSeriesSymbolMounting MethodSymbolClassificationPRPremium SeriesSteel FrameNoneFootNoneIndoor (IP44)VVertical FlangeOOutdoor Waterproof (IP44)FHorizontal FlangePOutdoor Dust &Water jet proof (IP55)Totally-enclosedFancooled TypeEnclosure Structure / Model NameTotally-enclosed Fancooled Type SF-PRVoltage/Frequency380 V 50 HzOperation RatingS1 (continuous)Power Transmission MethodDirect Coupling / Belt DrivenRotation DirectionCounterclockwise (CCW), viewed from shaft-end sideThermal Class120 (E): Frame Numbers 80M - 112M130 (B): Frame Numbers 132S - 180M155 (F): Frame Numbers 180LD - 225SAmbientConditionsTemperature-30 C to 40 CHumidity100% RH (no condensation)Altitude1000 m above sea level or belowAtmosphereNo corrosive/explosive gas, no steam or condensation, minimal dust.Coating ColorMunsell N7Applicable StandardsJIS C 4213, JEC-2137-2000SymbolWith/withoutBrakeNone Without BrakeBWith BrakeNote 1However, coating changes and so on are required for tropicalization: designate separately.2 This table does not include models with brakes.4outdoor type cannot be used.Refer to the Instruction Manual for motor handling.Characteristics Table380V50HzLoad CharacteristicsNumberOutput Frameof Poles[kW] Number[P]Current[A]4 Poles50% load[%]75% loadPowerFactor[%]Current[A][%]100% loadPowerFactor[%]EnergyCurrent urrentSpeed[A][min-1]Rated Maximum StartingTorque Torque 80355282168875 Characteristic calculation method is based on dynamometer method (actual measurement method). Characteristic values indicate representative values, not guaranteed values. Starting current tends to be larger than with SF-JR. Pay attention to the design of the distribution side. Rotation speed tends to be faster than with SF-JR. The motor output may increase, especially when using with a fan, pump, etc.7StartingCurrent[A]11.6

Dimensional DrawingsSF-PR Indoor MotorFigure - 1Figure - 3Shaft End DimensionsLLBAKLRRADKLDBKAKAQWNMFigure - 2UGCXBFENEMMLSViewing the mountingfeet from aboveFigure - KDLFXJFViewing the mountingfeet from aboveAKDKTHIXEZEXBFKGKDZFGCKGHQK*MViewing the mountingfeet from aboveViewing the mountingfeet from above* Since the key groove is machined with end mill, there is no roundness at the groove bottom. Dimension TableFrame ThermalNumber er4 125215327418.5, 22292.530349.537, 5143Dimensions 1—11446—Dimensions 90110110Shaft EndRS14019j6168.5 5 48k6370.5 55m6425.5 60m6432 8)(593)ApproximateUnloaded Mass (kg)Load Side Anti-Load Side4 Z1006309ZZ6308ZZ1206311ZZ6310ZZ150, 1556312ZZ6311ZZ2456315ZZ6312ZZ290, 3156315ZZ6312ZZ370Bearing 12141618180* The vertical tolerance for the shaft center is 0.5 . Since outline drawings are shown by representative models, some appearances may slightly differ depending on the frame number. Make sure to inquire when requiring exact external dimensions, since the external dimensions may be partially modified due to the refinement process, etc. For frame number 180 LD, the terminal box is on top of the motor, not side-mounted. (Differ from 180M.)8

SF-PRO 80M 225S FOOT TYPETOTALLY ENCLOSED FAN-COOLED TYPE, IP44 DEGREES OF PROTECTION (Outdoor Waterproof Motor)FeaturesWaterproof performance (IP44 Degrees of protection)Complies with the water spray test prescribed by JIS C 4034-5.ConstructionThe main parts of the motor are the same as of SF-PR type,but in order to provide stable operation even under severe outdoorconditions, such as wind, rain and snow, etc. special considerationis given to the following.1. Shaft through partBoth the load side and the anti-load side are provided with a fringerthat rotates together with the shaft so as to prevent water leakinginside the motor. In addition, an end cover is mounted to the loadon the anti-load side. Note that the shaft through part does not have a waterproofstructure since the load side is incorporated into the mating machine.3. Mating partLiquid gasket is applied to the frame and bracket mating section toimprove the waterproof performance.Reapply the liquid gasket when disassembling and reassembling themotor.4. Installation methodWaterproof performance is provided in the installation directionshown in the dimensional drawings; inquire in the case of nonstandard installation.5. CoatingCoated with paint that is excellent in weather resistance, saltwaterresistance, and chemical resistance.2. Terminal boxTerminal boxes with frame numbers from 80 to 180 are made ofsteel plate, and those with number 200 or higher are made of castiron. To ensure waterproof structure, a gasket is provided betweenthe base and the cover. Terminal block connection method is usedfor frame numbers 80 to 132, and lead wire connection method isused for frame numbers 160 and higher. Also, since the externalcable entry port is parallel pipe threaded, conduits and watertightcable glands can be installed.piping so as to prevent the ingress of water, dust, etc. Terminal box detailed view Example of shaft through structure on outdoorwaterproof motor (foot-mounted type)Anti-Load SideFrame NumberLoad SideAdjusting WasherPreload Spring80 - 225FringerEnd coverBearingMotorInteriorFringerBearingPF ScrewMotorInteriorFrame Numbers 80 to 18080 to 132: Terminal block method160, 180: Lead wire method(9)Frame Number 200 or more(Lead wire method)

Dimensional 上側より見てQE軸端寸法図QKWQKDKANKLF XBGCLRA KPEEMNViewing the mountingfeet from aboveXJXBZFGCXJFZKKGGCKGHIKDKATTXViewing the mountingfeet from aboveFigure - 4EDBMXKLREZFEKGGCJFJXBNViewing the mountingfeet from aboveKFQKDZFRGCKGXBKAKDKDHGCMFigure - 2AADEKGNKAEKLWKDXBRHIFBZFKDALZKGLUAFKLRXShaft End DimensionsULXFigure - 3KGFigure - 1HKDSF-PRO Outdoor Waterproof MotorViewing the mountingfeet from above* Since the key groove is machined with end mill, there is no roundness at the groove bottom.Frame ThermalNumber 0LD200LD225S120(E)130(B)155(F)Output(kW)4 Number Dimension sions 1—11446—J——40404040505050586470Dimensions 90110110Shaft EndRS14019j6168.5 24j619328j620028j6239 38k6258 38k6323 42k6345 42k6351.5 48k6370.5 55m6425.5 60m6432 594105127127184145205KDPF 3/4PF 3/4PF 3/4PF 3/4PF 1PF 1PF 1 1/4PF 1 1/4PF 1 1/2PF 2PF 2PF 2 Unloaded Mass (kg)Anti-Load Side4 Poles6204ZZ136205ZZ20

IEC 60034-30 (ef ciency classes of single-speed, three-phase, squirrel-cage induction motors) was enacted in October 2008 as an international standard for motor ef ciency. The ef ciency de ned therein is classi ed into levels from IE1 to IE4, and the larger this number is, the higher the ef ciency will be. Super Line Premium Series IE3 SF-PR

Related Documents:

3.0 Dynamic Modeling of three phase squirrel cage Induction Motor for Speed Torque Analysis The dynamic modeling of three phase squirrel cage induction motor is done by using a simulink designed model for three phase induction motor fed by PWM inverter. Table IV: Parameters Description Table of three phase Squirrel Cage Induction Motor I L (Amp)

Although single phase induction motor is more simple in construction and is cheaper than a 3-phase induction motor of the same frame size, it is less efficient and it operates at lower power factor. 1.5 WORKING OF SINGLE-PHASE INDUCTION MOTOR: A single phase induction motor is inherently not self-staring can be shown easily.

8.2.1.1 Stator of Three Phase Induction Motor The stator of the three phase induction motor consists of three main parts :. i. Stator Frame It is the outer most part of the three phase induction motor. Its main function is to support the stator core and the field winding. It acts as a covering and it provide

speed control of induction motor obtain wide speed range of induction motor with smooth drive control, reduces torque ripples, noise and also reduces loss. So, that it will improve the efficiency of induction motor. Induction motor has wide speed range from 300 RPM to 1415 RPM or rated speed of particular induction motor. For the digital speed .

Phase Induction Motor In Fig.6. the time response of electromagnetic torque of three-phase induction motor is expressed. The electromagnetic torque of three-phase induction motor is firstly variable in 0 to 0.4 second. The rated torque is reached at 0.8 seconds. Global Journal of Researches in Engineering Volume XII Issue vvvv 3

Three-Phase Squirrel-Cage Induction Motor Drive 2.1 Introduction This chapter presents an overview of the principle of three-phase squirrel-cage induction motor drive. First, the model and the related equations of three-phase induction machine are described and presented in both abc and

3.1 3-phase AC Induction Motor Drives The AC induction motor is a workhorse with adjustable speed drive systems. The most popular type is the 3-phase, squirrel-cage AC induction motor. It is a maintenance-free, less noisy and efficient motor. The stator is supplied by a balanced 3-phase AC power source. The synchronous speed ns of the motor is .

Lesson 12a: Three Phase Induction Motors ET 332b Ac Motors, Generators and Power Systems Lesson 12a_et332b.pptx 1 Learning Objectives Lesson 12a_et332b.pptx 2 After this presentation you will be able to: Explain how a three-phase induction motor operates Compute the synchronous speed of an induction motor and the slip between motor rotor and stator